• Title/Summary/Keyword: Performance Standard

Search Result 6,864, Processing Time 0.034 seconds

The Case Study on The Introduction and Practical Application of the Budget Management System -On the Performance Measurement of Standard Work Unit- (예산관리제도의 도입과 실제적 운용에 관한 사례연구 -표준적인 작업의 성과측정을 중심으로-)

  • 윤용운
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.2 no.2
    • /
    • pp.39-51
    • /
    • 1979
  • In introducing and applying the budget management system, the question of how to establish management structure(skelton) representing budget management responsible unit is significantly related to the degree of accuracy and analysis on the performance measurement of standard work unit. We have the following rational process of establishing performance measurement of budget management System ; 1) Standardization of work method 2) Establishment of management structure 3) Institution of budget management system. Especially, this system is based on a premise of efficiency of objectives management, it is assumed that performance measurement in the standard work unit must be enforced according to the basis and categories of performance evaluation based on the evaluating work unit. Therefore, most of all, the following three detail questions(subjects) are to be determined in order to rationalize these above principles to a maximum possible extent of performance measurement system. First, we established respective performance standard unit with respect to such detailed work unit, performance standard unit of which were accurately applicable directly from using the budget ana objectives account data and their supplementary data of the work measurement techniques. Second, by using the above mentioned question, over all evaluation and suggestion are made based on the study of the recording for each work unit development, budget management and production nit (volume of production) Third, the measurement of performance of budget management system is based on the principle of standard work unit, compared with the standard basis and actual work unit by period and activities unit and calculated percentage effectiveness according to the above procedure. and so evaluated the efficiency of performance measurement on the budget management system.

  • PDF

Factors Affecting Nurses' Performance of Standard Precautions for Infection in Public Medical Institutions: Focusing on Knowledge and Safety Environment (공공의료기관 간호사의 감염 표준주의지침 수행도 영향요인 : 지식, 안전환경 중심으로)

  • Lee, Ji-in;Kim, Jong Kyung
    • The Journal of the Korea Contents Association
    • /
    • v.21 no.7
    • /
    • pp.238-247
    • /
    • 2021
  • This study is a descriptive research to investigate the, safety environment, and performance of nurses working in public medical institutions on standard precautions for infection, and to identify factors affecting the performance of standard precautions for infection. As for the research method, data were collected through a questionnaire on 192 nurses from two public medical institutions in S city and N city, and the results were analyzed using the SPSS WIN 22.0 statistical program. From the research results, there was a significant difference in the knowledge of standard precautions according to work experience, and there was a significant difference in the safety environment of standard precautions according to the position. The average level of knowledge of standard precautions was 21.98/25 points, the average safety environment was 5.68/7 points, and the average performance was 40.28/60 points. There was a significant positive correlation between the safety environment of standard precautions and the performance of standard precautions (r=.21, p<0.01). The affecting factor on the performance of standard precautions was found to be the safety environment of standard precautions(𝛽=.22, p=.003). Therefore, to improve the performance of standard precautions for nurses' infection control in public medical institutions, Different and persistent infection management educational programs that consider the Historical situation and monitoring are required other than providing financial support and supportive safety environment.

A Study on the Development and of Establishment Performance Evaluation Criteria of Working Truck Mounted Attenuator (작업차량 장착용 충격흡수장치(TMA) 성능평가기준 수립 및 개발 연구)

  • Joo, Jae-Woong;Jang, Dae-Young;Park, Je-Jin
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.6
    • /
    • pp.185-191
    • /
    • 2012
  • Rear collisions to expressway work trucks result many casualties these days. But, currently, no special measure are being taken except deploying sign trucks behind the working trucks. In the U.S and Europe, trucks with TMA(Truck Mounted Attenuator) are being deployed behind the working truck, which is regarded as the standard method for work area safety, thereby reducing the fatality rates and property damage tremendously. Also, standard for the performance of TMA are established and TMA can be used in the field only when it satisfies the standard. In Korea, neither the standard for nor any guide to the TMA exists. In the situation some manufacturer developed TMA without proper performance evaluation and marketed limited number of TMAs in the field. In the study, NCHRP350, which is the performance standard of expressway safety features of U.S. and materials related to the TMA standard in Europe have been reviewed to establish the Korean performance criteria. Based on the review, and incorporating existing Korean standard for crash cushions, domestic standard for TMA has been proposed and applied in developing Korean TMA and crash tested it to verify the performance. The original design developed was crash tested and modified. The newly proposed design was studied using impact simulation program several times. Modifications were made after each simulation and prototype was built and crash tested as per the newly established TMA performance criteria.

Factors Influencing Nursing Students' Performance of Standard Precaution for Healthcare-Associated Infection Control (간호대학생의 의료관련감염관리를 위한 표준주의 수행도에 미치는 영향요인)

  • Yoon, Eun-Joo;Park, Young-Mi
    • Journal of Convergence for Information Technology
    • /
    • v.8 no.5
    • /
    • pp.19-27
    • /
    • 2018
  • The goal of this study was to survey the degree of nursing students' knowledge of standard precaution, intention about performance, attitude toward performance, safety climate, performance of standard precaution and to identify factors influencing performance. A cross-sectional survey was implemented with samples of 296 nursing students. We collected the data from June 15 to 30, 2018 and analyzed by SPSS 21.0 program. There were significant correlation between intention about performance, attitude toward performance, safety climate and performance. The factors that affecting performance of standard precaution among nursing students are intention about performance and safety climate, which explained 20% of the variances. Therefore, It needs to develop an infection management education program and to prepare an safe nursing practice environments in hospitals for nursing students to improve their implementation of standard precautions for preventing clinical infection.

A Study on Floor Slip Resistance Standard and Test Method for BF Certification (BF인증을 위한 바닥 마감재 미끄럼 성능기준 및 측정방법에 대한 연구)

  • Shin, Dong-Hong;Seong, Ki-Chang;Park, Kwang-Jae
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.25 no.3
    • /
    • pp.75-83
    • /
    • 2019
  • Purpose: There are no clear criteria for slip performance in the BF certification process, so the evaluator relies on subjective judgments depending on the field situation. Physical criteria for determining the slip performance of various floor finishes are not clear. C.S.R., the only criterion currently being used to check slip performance, may raise questions about its coverage, feasibility and reliability. Method: For an analysis of domestic standards and status, KS L 1001, KS M 3510, and KS F 2375. External standards are analyzed for ADA Standard, ANSI Standard, and BS EN Standard. Analyze the test methods and evaluation criteria of O-Y-PSM, BPT, and the dynamic slip resistance test used in these criteria. It also presents an improvement plan for the rational presentation of standards. Results: To date, various kinds of test methods and measuring devices of the slip resistance coefficient have been developed, but there are not many ways to trust useful results related to user safety. Reliability and thoroughly verified test methods and criteria should be used to assess the slip performance of the floor. In order to improve the standard for the evaluation of slip performance in Korea, the existing standard should first be raised to the same level as the overseas standard, and the application of the discriminatory standard should be applied considering the characteristics and usage patterns of each space. Implication: Currently, Korean standards propose various test methods, but the proper use of test methods, scope and assessment criteria are not established, so improvement of the comprehensive standard is necessary.

A Study on the Performance Measuring Methods and Standard for the Technical Package in Zero Energy Building (제로에너지빌딩의 기술 패키지 구성을 위한 성능 기준 및 성능 측정 방법에 관한 연구)

  • Sung, Uk-Joo;Rim, Min-Yeop;Kim, Seok-Hyun;Cho, Soo
    • Journal of Korean Institute of Architectural Sustainable Environment and Building Systems
    • /
    • v.12 no.6
    • /
    • pp.543-556
    • /
    • 2018
  • Zero energy building was attended for energy consumption minimization by the energy saving technology about building heating and cooling energy consumption and the renewable energy production facility. So the government has supported the zero energy building supply for decreasing green gas emissions. The study about inventory of zero energy building has many proceeding. That inventory need the information of material and equipment. So information of material and equipment about zero energy building must be included for the zero energy building realization. Actually the database of zero energy building inventory construction through the inventory established studies has difficult because the database need many information. In this study, author proposed the test methods and performance reference for upload at inventory. It was constructed to material - module - package. Also the author analyzed the construction of the technical package for zero energy building. The author separated performance category to the energy performance for energy analysis and other performance for confirmed the durability, stability and etc. This performance category proposed the table. The test methods of material and equipment in the passive package and active package proposed to the international standard and korea standard basically korea standard. Also the performance reference was proposed to korea legal standard and various standard by this study results. And the authors proposed the table of performance value, test methods, performance reference. By result of this study, the test methods and performance reference will be used the basic data for inventory of zero energy building.

Influence of Standard Precaution Knowledge, Performance on Nursing Professionalism in Nursing Students (간호대학생의 표준주의 지식과 수행도가 간호전문직관에 미치는 영향)

  • Yang, Jin-Ju
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.4
    • /
    • pp.503-510
    • /
    • 2021
  • Purpose: This study was attempted to identify knowledge, performance of standard precautions, and nursing professionalism and to investigate the influence on nursing professionalism in nursing students experienced clinical practice. Methods: The subjects are 205 nursing students in six university nursing departments in two regions. The data were collected from September 7th to September 17th, 2021 using the online survey. Results: The total score for knowledge of standard precautions was 24.69. The average for performance of standard precautions was 3.70 on a scale of 4 and nursing professionalism was an average of 4.12 on a scale of 5. Factors affecting nursing professionalism included gender(β=-.21, p=.002), knowledge of standard precautions(β=.13, p=.044), and performance of standard precautions(β=.27, p=<.001). The explanatory power of the model was 13.1%. Conclusions: Results of this study suggest that it is necessary to develop and apply an clinical educational program that can promote knowledge and performance of standard precautions to enhance the positive nursing professionalism of nursing students.

A Study on the Performance Standards for a Natural Type Landscaping Rocks by Utilizing GFRC(Glass Fiber Reinforced Concrete) (유리섬유강화콘크리트를 이용한 자연형 경관석의 성능기준 연구)

  • Yoon, Bok-Mo;Koo, Bon-Hak
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.5
    • /
    • pp.33-42
    • /
    • 2012
  • This study aims to establish the performance standard for natural type landscape stone GFRC. The required performance such as material performance, structural safety performance, durability performance, and landscape performance were selected through an examination of domestic and overseas performance related references and examples, and through the questionnaires obtained from 40 experts, and the verified items and performance standards were proposed. Among the required performances, the material performance(glass fiber content, air-dried gravity), structural safety performance(flexural strength, compressive strength), durability performance(crack, corrosion resistance), and landscape performance(texture, efflorescence) were selected through the questionnaires obtained from the experts. In the case of material performance and structural safety performance with the corresponding standards that existed, final performance evaluation standard was proposed by conducting a test and comparing it with the existing standard sample, and in the case of durability performance and landscape performance on which standard does not existed, they were verified by measuring directly through field examination of formative landscape items such as artificial waterfall etc. In this study, performance standard for the material on natural type landscaping rocks GFRC and items which can be evaluated after construction such as material performance, structural safety performance, durability performance, landscape performance, and so forth were proposed, however, follow up study for pro-environmental and ecological performance standard which were recently gaining force would be required through a continuous monitoring for the construction samples afterwards.

A Numerical Analysis on the Pressure Field Around KTX Train Using the Standard Framework of CFD Analysis for Railway System (철도시스템 전산유체해석 표준 프레임웍을 이용한 KTX 차량 주변 압력장에 대한 수치해석)

  • Nam, Sung-Won;Cha, Chang-Hwan;Kwon, Hyeok-Bin
    • Journal of the Korean Society for Railway
    • /
    • v.9 no.5 s.36
    • /
    • pp.511-516
    • /
    • 2006
  • A standard framework of CFD(Computational Fluid dynamics) analysis for railway system has been developed to evaluate the overall aerodynamic performance of railway system and has been adopted to numerical simulation of the pressure field around KTX train. The framework is composed of standard aerodynamic model and standard aerodynamic performance to customize the general CFD solution process reflecting the characteristics of railway system such as various operation mode and performance factors. The results show that the standard framework of CFD analysis for railway system can provide objectivity and consistency to the CFD analysis for railway system and the pressure field around KTX train has been successively solved.

The experimental study on the Evaluation of fire-proof performance and bond characteristics for development of 3hours Fire-Proof paint (3시간 내화도료의 개발을 위한 내화성능 및 부착특성 평가에 관한 실험적 연구)

  • Kim, Soo-Young;Kim, sung-kil;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.11a
    • /
    • pp.63-64
    • /
    • 2012
  • Recently, Fire-proof performance of buildings becomes important to ensure safety. As a result, fire-proof paint is required for 3 hours. However, Experiments are only performed by standard KS F 2271 for estimation of fire-proof paint. Because there is no domestic estimation standard for performance of fire-proof paint as well. So estimation standard of fire-proof paint is needed to guarantee their performance for establishing quality system and to assure same performance for safety of people in the building from unpredicted fire accident. Owing to these reasons, we studied comparative estimation for quality performance of two kinds of fire-proof paint and bond performance.

  • PDF