• Title/Summary/Keyword: Performance Standard

Search Result 6,942, Processing Time 0.029 seconds

Performance Evaluation of DRM+ System in Laboratory Trials

  • Baek, Myung-Sun;Park, Sora;Lee, Yonghoon;Kim, Geon;Lim, Bo-Mi;Song, Yun-Jeong;Im, Chae-Hun;Lee, Yong-Tae
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.295-296
    • /
    • 2011
  • The DRM+ is the newest digital radio standard for in-band environment. Although various state of the art technologies are adopted, the performance evaluation information is not sufficient. It is hard that many countries and stations considering the DRM+ as their digital radio standard check the performance of DRM+. To evaluate the performance of the DRM+ system, this paper depicts the laboratory trial results of DRM+ standard. In the laboratory trial, the rack type DRM+ test bed is built. To reflect the practical broadcasting environment, various tests are executed. Many countries and stations can efficiently use these test results, which are considering converting their analog radio broadcasting to digital broadcasting.

  • PDF

Implementation and Performance Analysis of a Digital IF Transceiver for an SDR-based Reconfigurable Base Station

  • Yu, Bong-Guk;Ra, Sung-Woong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.9A
    • /
    • pp.900-908
    • /
    • 2008
  • This paper presents the implementation and performance test of a Digital IF transceiver for a SDR-based mobile communication base station. The transceiver is reconfigurable to HSDPA and to three profiles, 7 MHz, 3.5 MHz, and 1.75 MHz, each incorporating the IEEE 802.16d WiMAX standard. The transceiver can be reconfigured to other standard profiles through software downloaded onto identical hardware platforms. Experimental results show that the transceiver can be reconfigured to other systems and the performance of the transceiver satisfies the recommended performance criteria of each standard.

Emergency Medical Technology Students' Awareness and Performance of Standard Precautions in Hospital Infection Control (응급구조과 학생의 병원감염 표준주의에 대한 인지도와 수행도)

  • Choi, Sung-Soo;Yun, Seong-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.5
    • /
    • pp.2262-2270
    • /
    • 2013
  • This study was to provide the basic data to raise the efficient practices that can reduce the Infection Prevention and Exposure by understanding the awareness, Performance degree of the Administrative Standard Guideline of Nosocomial Infection Control for Emergency Medical Technician students who are exposed to hospital infections while conducting clinical practice. After the study, the performance degree was lower than the awareness of the Performance degree of the Administrative Standard Guideline of Nosocomial Infection Control. And awareness and performance degree are have significant positive correlation, significant differences statistically(r=0.325, p=0.000). In the future, to improve the Performance degree of Nosocomial Infection Control for Emergency Medical Technician students, the continuing education programs and the curriculums should be performed in the practice agencies.

Research on Health Performance Evaluation of Existing Buildings using WELL Building Standard - for Green Remodeling applied Buildings - (웰 빌딩 스탠다드를 활용한 기존 건축물의 건강성능평가 연구 - 그린리모델링 적용 건축물을 대상으로 -)

  • Lee, Du Hwan;Kim, Young Il;Kim, Jae Moon
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.36 no.2
    • /
    • pp.165-173
    • /
    • 2020
  • The purpose of this research is to evaluate the health performance of existing buildings which completed green remodeling using the WELL Building Standard developed by Delos in the USA. The features and the level of improvement in health were examined and the results were as follows. As a result of comprehensive evaluation of the health performance of the target building, the health performance after green remodeling improvement was improved by 17.3% compared to before green remodeling. As a result of applying the alternatives for improving health performance, improvements were 22.9% by Alternative 1, 28.8% by Alternative 2, and 28.7% by Alternative 3. If the improvement ratio with respect to the construction cost were compared, Alternative 1 was the best followed by Alternative 2. Finally, the cost effectiveness of improving health performance against construction cost were best in the order of self-closing door installation, airtight seal, and pest inspections.

The Study of Optimal Performance Improvement Method for Aircraft of Various Variants within the Same Type (다양한 형상의 동일 기종 항공기에 대한 성능개량 최적 구현 방안 연구)

  • Kim, Youngil;Ahn, Seungbeom;Choi, Myeongseok
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.25 no.3
    • /
    • pp.311-320
    • /
    • 2022
  • In this paper, we studied the optimal method of improving performance for aircraft having various variants within the same type. The study defined configuration of an entire fleet of aircraft being subject to a performance improvement program. And selected the most complicated aircraft configuration among them as a Standard Aircraft for modification by according to the proposed Aircraft Selection Process for developing an optimal Aircraft Performance Improvement Process. Based on the selected the Standard Aircraft, drew a system integration design result and carried out Evaluation Test and obtained Airworthiness Certification. Created the database with the design data of the Standard Aircraft, Evaluation Test, and Airworthiness Certification results, and applied it to variants of aircraft to complete the performance improvement program with optimized schedules and costs. By applying the proposed method to IFF performance improvement program, drew optimal system integration design and completed the program with minimized schedule.

Influences of Medical-related Infection Prevention Knowledge and Infection Control Confidence on Standard Precautions Performance of Nursing students (간호대학생의 의료 관련 감염예방 지식과 감염관리 자신감이 표준주의 실행도에 미치는 영향)

  • Su-Jin Kim;Hyun-Jin Jeong;Su-Ol Kim
    • Journal of the Korean Applied Science and Technology
    • /
    • v.39 no.6
    • /
    • pp.812-823
    • /
    • 2022
  • The purpose of this study is a descriptive study to confirm the relationship between medical infection prevention knowledge, infection control confidence, and standard practice of nursing students and to understand the effect on performance for standard precautions. Data collection was conducted on 160 nursing students located in G Metropolitan City from October 4 to October 12, 2018. As a result of the study, the performance for standard precautions has a positive correlation with 'infection prevention knowledge' (r=.27, p<.001) and infection control confidence (r=.52, p<.001), and infection prevention knowledge was found to have a significant correlation with infection control confidence (r=.27, p=012). Factors affecting the performance for standard precaution of nursing students were in order of infection control confidence (𝛽=.45, p<.001), no skin contact experience (𝛽=.18, p<.004), infection prevention education (𝛽=-2.65, p<.009), infection prevention knowledge (𝛽=.15, p<.019). and the explanatory power of the model was 35%. Based on the results of this study, it is necessary to develop and implement a standard precautions program that can increase infection prevention knowledge and infection management confidence in order to increase the performance for standard precautions of nursing students.

Verification of Effectiveness of the Standard Floor Impact Source by Comparing with Living Impact Sources (실생활 충격소음을 통한 표준 바닥충격원의 실효성 검증)

  • Park, Hyeon Ku;Kim, Kyeong Mo;Kim, Sun-Woo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.12
    • /
    • pp.1117-1126
    • /
    • 2013
  • The standard impact sources, standardized to rate the sound insulation performance of floor structure, should simulate well the real floor impact sources, which is very important to grade the floor structure then to establish counter plan to improve the performance of floor. Recently the tire, the standard heavyweight impact source, has been discussed that the impact force is too big to represent the real impact force. And researches have been carried on the applicability as a substitute or a supplementary. In addition, tapping machine, the standard lightweight impact source, is also questionable if it is representative of real lightweight impact source. This study aims to examine the similarity of standard impact sources with living impact sources, comparing the physical characteristics such as impact force, frequency contents and sound level. The result showed that the physical characteristics of standard impact sounds were somewhat different with that of living impact sounds, and the standard sources couldn't be verified from this result. Later subjective evaluation should be followed to compare how the physical differences make relationship with the subjective differences.

A Study on the Evaluation of School Health Policy Performance Process of Korea -Focused on the Secondary School in Pusan City- (한국의 학교보건정책집행과정평가 연구 -부산직할시를 중심으로-)

  • 권혁동
    • Health Policy and Management
    • /
    • v.5 no.1
    • /
    • pp.59-79
    • /
    • 1995
  • This study intended to grasp the results of performance of school health policy and to provide information for the future policy performance in Korea. As the objects of the study we chose the secondary school(142 middle schools, 111 high schools) in Pusan, 1993. The contents of the study were about school health service and school health education. For the study we collected datum and took statistics through the existing theses, books, various statistics, and interviews with the persons concerned. Therefore the method of the study was basically emperical and demonstrative. The results of the study can be presented as follows : 1. the results of performance of health service proved to be 5.40% for vaccination against hepatitis B, 5.26% for typhoid fever, 6.65% for EH fever, and 9.84% for influenza in middle schools, In high schools' 5.76% for vaccination against hepatitis B, 0.03% for typhoid fever, 0.25 for EH fever, and 0.86% for influenza. 2. The results of policy performance of health education were found out 64.08% in middle schools, and 17.12% in high schools. 3. The factors which affected the results of performance of health service turned out 1) the improper standard of policy performace that applicants should pay their own expenses. 2) the lack of performer's will to carry out the policy owing to the improper standard. 3) the shortage of interorganizational enforcement activities and communications which influence the will of performance. 4. The affecting factors to the will of performance of health education proved to be 1) the improper standard that nurse-teachers can teach students in the classroom in case of need. 2) the lack of nurse-teachers due to the above inappropriate standard. 3) the lack of enforcement activities of supervising organs which employ and direct nurse-teachers. 4) the lack of activities of organs which should communicate one another and allot nurse-teachers of public schools without fail.

  • PDF

Strength Index in Seismic Performance Evaluation Method of Existing Reinforced Concrete Buildings (기존 철근콘크리트 건물 내진진단법의 강도지표)

  • 이원호
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2000.10a
    • /
    • pp.278-287
    • /
    • 2000
  • In Korea, countermeasures against earthquake disasters such as the seismic performance evaluation and/or retrofit scheme of buildings have not been fully performed since Korea had not been experienced many destructive earthquakes in the past. However, due to more than four hundred earthquakes with slight/medium intensity occurred in the off-coastal and inland of Korea during the past 20 years, and due to the great earthquakes occurred recently in neighboring countries, such as the 1995 Hyogoken-Nambu Earthquake with more than 6,500 fatalities in Japan and the 1999 Ji-Ji Earthquake with more than 2,500 fatalities in Taiwan, the importance of the future earthquake preparedness measures in Korea is highly recognized. The main objective of this paper is to provide the basic data for development of a methodology for the future earthquake preparedness in Korea by investigating the concept and applicabilities of the Japanese Standard for Evaluation of Seismic Performance of Existing RC Buildings developed in Japan among the methodologies of all over the world. In this paper, a seismic performance evaluation method of the existing reinforced concrete buildings is proposed based on experimental data of columns and walls carried out in Korea by referring the Japanese Standard, especially focusing on the Strength Index(C) among the indices in the seismic capacity index(IS) equations. Also, the seismic capacities of two existing reinforced concrete buildings in Korea are evaluated based on the proposed methodology and the Japanese Standard, and the correlations between the seismic capacities by the proposed methodology and the Japanese Standard are discussed.

  • PDF

Analysis on the Performance Evaluation Trends of Heat Pumps and the Test Standards of a Geothermal Heat Pump in Korea (히트펌프 성능 평가 동향과 국내 지열원 히트펌프 성능 평가 규격 및 제도 분석)

  • Kang, Shin-Hyung;Choi, Jong Min
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.13 no.4
    • /
    • pp.31-38
    • /
    • 2017
  • The heating and cooling air conditioning field has been increasing the problems of energy consumption and global warming in the world. A geothermal heat pump has been known as one of the highest efficient heating and cooling system. In this study, the analysis about the test standards of the geothermal heat pump of the Republic of Korea was executed. From the research, the following results were given. It is needed to address the domestic test standard for direct heat exchange geothermal heat pump. Water to air multi geothermal heat pump test standard was only developed in Korea. The test standard to calculate a seasonal energy efficiency ratio for cooling period and heat seasonal performance factor for heating period should be newly developed to estimate actual annual energy consumption and $CO_2$ emission.