• Title/Summary/Keyword: Performance Standard

Search Result 6,990, Processing Time 0.043 seconds

Kinematic Characteristics Based on Proficiency In Geoduepyeopchagi in Taekwondo Poomsae Koryo

  • So, Jae Moo;Kang, Sung-Sun;Hong, AhReum;Jung, Jong Min;Kim, Jai Jeong
    • Korean Journal of Applied Biomechanics
    • /
    • v.26 no.4
    • /
    • pp.343-351
    • /
    • 2016
  • Objective: The purpose of this study was to help improve game performance and provide preliminary data to enhance the efficiency of the kick and stability of the support foot by comparing the kinematic characteristics of the repeated side kick (geodeupyeopchagi) in poomsaeKoryo between expert and non-expert groups. Method: The subjects were divided into 2 groups according to proficiency in Taekwondo, an expert group and a non-expert group (n = 7 in each group), to observe the repeated side-kick technique. Four video cameras were set at a speed of 60 frames/sec and exposure time of 1/500 sec to measure the kinematic factors of the 2 groups. The Kwon3D XPprogramas used to collect and analyze three-dimensional spatial coordinates. Ground reaction force data were obtained through a force plate with a 1.200-Hz frequency. An independent samplesttest was performed, and statistical significance was defined as .05. The SPSS 18.0 software was used to calculate the mean and standard deviation of the kinematic factors and to identify the difference between the experts and non-experts. Results: The angular displacement of the hip joint in both the expert and non-expert groups showed statistical significance on E1 and E4 of the left support foot and E5 of the right foot (p<.05). The angle displacement of the knee joint in both groups showed statistical significance on E4 of the left support foot, and E1 and E2 of the right foot (p<.05). The angular velocity of the lower leg in both groups showed no statistical significance on the left support foot but showed statistical significance on E2 and E6 of the right foot (p<.05). The angular velocity of the foot in both groups showed no statistical significance on the left support foot but showed statistical significance on E2 of the right foot (p<.05). The vertical ground reaction force in both groups showed statistical significance on E2 (p<.05). The center of pressure in all directions in both groups showed statistical significance (p<.5). Conclusion: While performing the repeated side kick (geodeupyeopchagi), the experts maintainedconsistency and stability of the angle of the support leg while the kick foot moved high and fast. On the other hand, the angle of the support foot of non-experts appeared inconsistent, and the kick foot was raised, relying on the support leg, resulting in unstable and inaccurate movement.

A Study on Recognition and Expectation on School Nurse's Work at the Primary, Secondary School Students and Their Teachers in Suwon (양호교사(養護敎師) 업무(業務)에 대(對)한 인지(認知) 및 기대(期待) 조사연구(調査硏究))

  • Park, Youug Nam
    • Journal of the Korean Society of School Health
    • /
    • v.4 no.1
    • /
    • pp.100-115
    • /
    • 1991
  • The purpose of this study is to provide the necessary data for the effective performance of school nurse's work by comparing with the recognition and expectation on school nurse's work by the students and their teachers in school settings. The sample of this study was consisted of the 441 students and 535 teachers in Suwon. The data were collected by means of a structured questionnaire from 24th, Sept, to 29th, Sept. 1990. The collected data were analyzed utilizing SAS/PC program for percentage, frequency, mean, standard deviation and chisquare test. The major findings of this study were as follows: 1. The result of analysis in recognition on school nurse's work. There is no statistically significant difference 'depending on teachers' school level, sex, age and career with school nurse(P>0.05). The students show significant difference on their school level and sex(P>0.05). Also, in the areas of school nurse's work, school clinic management has the highest recognition and school environment management has the lowest recognition. 2. The result of analysis in expectation on school nurse's work. There is statistically significant difference depending on teachers' and students' school level: the order of expectation is elementary, middle, and high school(P<0.05). In the result of comparison with students' and teachers' expectation in the same school level, there is significant difference only in elementary school(P<0.05). However, there is no statistically significant difference depending on teachers' sex, age, career with school nurse and students' sex(P>0.05). Also, in the areas of school nurse's work, school clinic management has the highest expectation and school environment management has the lowest expectation. Synthesizing the result of the study, we can have the conclusion like following. First, students' recognition on school nurse's work is lower than teachers' because most of school nurse's work is performed through their homeroom teachers or other teachers. That can be the limitation for students to recognize school nurse's work. So, there must be a chance of regular meeting between school nurse and students to perform school nurse's work effectively. For this. we must change our educational system and make school nurse charge regular lesson. Second, in each area of school nurse's work, both students' and teachers' recognition and expectation about the area of school environment management has much lower score than the other areas. This indirectly shows the school nurse don't do the work of the area actively. So, school nurses must make an effort to do the work of the area actively. And we must enforce the education of this area in education for new school nurses or re-education for school nurses.

  • PDF

A Study of wear and Matching of Diesel Engine Exhaust Valve and Seat Insert Depending on Valve Materials (디젤엔진 배기밸브와 시트 인서트의 밸브 재질에 따른 마모 및 매칭성 연구)

  • Kim, Yang-Soo;Chun, Keyoung-Jin;Hong, Jae-Soo;Chung, Dong-Teak
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.6
    • /
    • pp.108-115
    • /
    • 2008
  • The wear on engine valve and seat insert is one of the most important factors affecting engine performance. The engine valve and seat insert must be able to withstand the severe environment that is created by: high temperature exhaust gases generated while the engine is running, rapid movement of the valve spring, high pressure generated in the explosive process. In order to study such problems, a simulator has been developed to generate and control high temperatures and various speeds during motion. The wear simulator is considered to be a valid simulation of the engine valve and seat insert wear process with various speeds during engine activity. This work focused on the test of various degrees of wear on four different exhaust valve materials such as HRV40, HRV40-FNV (face nitrided valve), STL #32, STL #6,. Throughout all tests performed in this study, the outer surface temperature of the seat insert was controlled at $350^{\circ}C$, the cycle number was $4.0{\times}10^6$, the test load was 6860 N, the fuel was LPG the test speed was 20 Hz (2400 RPM) and the seat insert material was HVS1-2. The mean (standard deviation) maximum roughness of the exhaust valve and seat insert was $25.44\;(3.16)\;{\mu}m$ and $27.53\;(3.60)\;{\mu}m$ at the HRV40, $21.58\;(2.38)\;{\mu}m$ and $25.94\;(3.07)\;{\mu}m$ at the HRV40-FNV, $36.73\;(8.98)\;{\mu}m$ and $61.38\;(7.84)\;{\mu}m$ at the STL #32, $73.64\;(23.80)\;{\mu}m$ and $60.80\;(13.49)\;{\mu}m$ at the STL #6, respectively. It was discovered that the maximum roughness of exhaust valve was lower as the high temperature hardness of the valve material was higher under the same test conditions such as temperature, test speed, cycle number, test load and seat insert material. The set of the HRV40-FNV exhaust valve and the HVS1-2 seat insert showed the best wear resistance.

Infill-system Development for Long-Life Housing with Durability & Flexibility: Focused on the Constructing and Evaluating Application of Mock-up House (내구성 및 가변성을 갖는 장수명 공동주택의 가변요소 시스템 개발 : 실험주택 건립 및 적용성 평가를 중심으로)

  • Cheong, So-Yi;Park, Joon-Young;Chun, Young-Soo
    • Land and Housing Review
    • /
    • v.2 no.4
    • /
    • pp.397-406
    • /
    • 2011
  • This research aims to develop various infill-systems for practically applying to long-life housing with 100-year durability and flexibility as a strategy for realizing sustainable residential environment. Especially, the developed infill-systems & technologies were concentrated to the mock-up house applied with the standard model of long-life housing, and their in-situ applicability by a phase, experts' consultation, and questionnaire survey were also evaluated. This research was executed to divide by 3 phases. In the First phase infill-systems for a housing unit of $84m^2$ exclusive use area as well as a support of whole structure and infill-systems including dry wall, and windows were constructed, and their in-situ applicability were evaluated. In the Second phase vertical integration of upper and lower housing units of $50m^2$ and $40m^2$ exclusive use area was investigated the first in domestic for 3 housing units of $50m^2$ exclusive use area. In addition, various infill-systems including the horizontal expansion of $50m^2$ and $10m^2$ exclusive use areas were also constructed and evaluated on their in-situ applicability. In the third phase diverse performance tests and field investigation for in-situ verifying of dry Ondol, developed this research, were executed to improve their practicability. Inner dry walls were taken apart, moved and re-constructed for verifying their practicability to investigate 3R-Reduce, Reuse and Recycle-realization too.

The Peak Systolic Pressure-End Systolic Volume Index Relation in Patients with Coronary Artery Disease Using Radionuclide Gated Blood Pool Scintigraphy (관상동맥질환에서 심장풀스캔을 이용한 최고수축기혈압-수측기말용적곡선의 분석)

  • Kim, Byung-Tae;Koong, Sung-Soo;Bom, Hee-Seung;Chung, June-Key;Park, Young-Bae;Lee, Myung-Chul;Lee, Young-Woo;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.21 no.2
    • /
    • pp.175-182
    • /
    • 1987
  • For measurement of ventricular performance, ejection fraction (EF) has gained wide acceptance. But EF is influenced not only by changes in muscle function but also by changes in cardiac loading conditions. In case of valvular heart disease which is variable in loading conditions, EF cannot be reliable as an index of myocardial contractility. The end systolic pressure (ESP)-end systolic volume (ESV) relation, howver, is known to represent myocardial contractility, independent of changes in loading conditions. Similar results can be obtained by using peak-systolic pressure (PSP) instead of ESP. To evaluate the utility of the peak systolic pressure-end systolic volume index (PSP-ESVI) relation as an index of myocardial function, we measured $PSP&ESVI$ in 19 partents with coronary artery disease before $(PSP_1\;&\;ESVI_1)$ and after $(PSP_2\;&\;ESVI_2)$ sublingual administration of nitroglycerin. PSP was measured with standard mercury sphygmomanometer during gated blood pool scintigraphic study. ESVI was measured by count derived method after attenuation correction. $PSP_2\;&\;ESVI_2$ measurement was started when the fall of PSP was greater than 5 mmHg after 7-14 minutes post-administration of nitroglycerin. Mean values $({\pm}S.D.)$ of $PSP_1\;&\;ESVI_1$ was $124.9({\pm}20.7)mmHg\;&\;59.4({\pm}39.9)ml/M^2$. Mean values $({\pm}S.D)$ of $PSP_2\;&\;ESVI_2$, was $113.2({\pm}19.9)mmHg\;&\;37.5({\pm}26.1)ml/M^2$. There was a significant difference between mean values of $PSP_1\;&\;PSP_2$, (p<0.01), and mean values of $ESVI_1\;&\;ESVI_2$, (p<0.01). $PSP_1-PSP_2/ESV_1-ESVI_2,\;PSP_1/ESVI_1$ and EF were in the range of 0.14-5.19 mmHg/ml/$M^2$, 0.67-7.68 mmHg/ml/$M^2$ and 10.8%-74.5% respectively. $PSP_1-PSP_2/ESVI_1-ESVI_2$, and EF showed exponential correlation (r=0.85, P<0.01). The correlation coefficient between $PSP_1/ESVI_1$ and EF was 0.73(p<0.01). With the above results, we suggest that $PSP_1-PSP_2/ESVI_1-ESVI_2$, and $PSP_1/ESVI_1$, can be used as an index of myocardial function.

  • PDF

Development of Disposable Immunosensors for Rapid Determination of Sildenafil and Vardenafil in Functional Foods

  • Vijayaraj, Kathiresan;Lee, Jun Hyuck;Kim, Hyung Sik;Chang, Seung-Cheol
    • Journal of Food Hygiene and Safety
    • /
    • v.32 no.2
    • /
    • pp.83-88
    • /
    • 2017
  • We introduced disposable amperometric immunosensors for the detection of Sildenafil and Vardenafil (SDF/VDF) based on screen printed carbon electrodes. The developed immunosensors were used as a non-competitive sandwich-type enzyme immunoassay with a horseradish peroxidase label. The sensors were constructed on screen printed carbon electrodes by the simple electrochemical deposition of a reduced graphene oxide and chitosan (ErGO-CS) composite. To evaluate the sensing chemistry and optimize the sensor characteristics, a series of electrochemical experiments were carried out including electrochemical impedance spectroscopy, cyclic voltammetry and amperometry. The sensors showed a linear response to SDF/VDF concentrations in a range from 100 pg/mL to 300 ng/mL. The lower detection limit was calculated to be 55 pg/mL, the sensitivity was calculated to be $1.02{\mu}Ang/mL/cm^2$, and the sensor performance exhibited good reproducibility with a relative standard deviation (RSD) of 7.1%. The proposed sensing chemistry strategy and the sensor format can be used as a simple, cost-effective, and feasible method for the in-field analysis of SDF/VDF in functional or health supplement food samples.

Comparison of Methods for Detection of Escherichia coli O157:H7 in Ground Beef and Radish Sprouts

  • Lee, Jae-Hoon;Hyeon, Ji-Yeon;Heo, Seok;Hwang, In-Gyun;Kwak, Hyo-Sun;Choi, In-Soo;Park, Chan-Kyu;Seo, Kun-Ho
    • Food Science of Animal Resources
    • /
    • v.30 no.2
    • /
    • pp.179-184
    • /
    • 2010
  • Escherichia coli O157:H7 is a food-borne pathogen that causes bloody diarrhea, hemorrhagic colitis, and hemolytic uremic syndrome (HUS). We compared three selective media and evaluated the performance of immunomagnetic separation (IMS) for the detection of low levels of E. coli O157:H7 in ground beef and radish sprouts with different levels of background flora. Bulk food samples (500 g for each trial) were artificially inoculated with nalidixic acid-resistant E. coli O157:H7 at the lowest dose that would generate 20 partial-positive samples of 25 g each. All samples were homogenized in mTSB (225 mL) and incubated overnight at $37^{\circ}C$. IMS was performed using the enriched mTSB samples (1 mL) along with conventional spreads plated onto three different selective media: Sorbitol MacConkey agar (SMAC), Sorbitol MacConkey agar with cefixime and tellulite (CT-SMAC), and Sorbitol MacConkey agar with nalidixic acid (NAL-SMAC) as the gold standard. Two suspicious colonies from each medium were selected and confirmed usinga serological test after transfer to tryptic soy broth with yeast extract (TSAYE). CT-SMAC was better than SMAC for detecting E. coli O157:H7 in all food types. Although there was no statistical difference in the number of positive samples when using IMS vs. non-IMS techniques, more positive samples were detected when IMS was used in both ground beef and radish sprouts. It appears that the improvement was more significant in radish sprouts, which had a higher level of background flora than ground beef. The results also suggest that the combination of CT-SMAC and IMS is sufficient to recover low levels of E. coli O157:H7 in high background flora food samples.

Evaluation of the Impact of Fuel Economy by Each of Driving Modes for Medium-Size Low-Floor Bus (중형저상버스의 개별주행모드에 따른 연료소비율 평가)

  • Jung, Jae-wook;Ro, Yun-sik;Ahn, Byong-kyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.9
    • /
    • pp.133-140
    • /
    • 2016
  • The Ministry of Land, Infrastructure and Transport has introduced low-floor buses, which are convenient for passengers getting on and off the bus and for the handicapped. The standard bus model is 11 m long and uses compressed natural gas (CNG). However, this model has drawbacks in narrow rural road conditions such as those in farming and fishing villages and mountainous areas, as well as difficulty in refueling since CNG facilities are not readily available. In this study, running resistance values were obtained by coasting performance tests on actual roads using a Tata Daewoo LF-40 model with three different weight conditions: curb vehicle weight (CVW), half vehicle weight (HVW), and gross vehicle weight (GVW).The test methods include WHVC, NIER-06, and constant-speed driving at 60 km/h. These tests were used to measure the fuel economy of vehicles other than the target vehicles to obtain the combined fuel economy. The energy efficiency was highest in the case of CVW. In the WHVC mode, the fuel consumption rates of HVW and GVW were typically 3.5% and 12% higher than that of CVW, respectively. In constant-speed driving, the fuel efficiency of HVW was higher than that of CVW. Further research is required to analyze the exhaust gas data.

Corrosion Analysis of Ni alloy according to the type of molten metal (용융아연도금욕에 적용되는 용탕에 따른 Ni합금의 부식성 분석)

  • Baek, Min-Sook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.6
    • /
    • pp.459-463
    • /
    • 2017
  • Hot dip galvanizing in the steel plant is one of the most widely used methods for preventing the corrosion of steel materials including structures, steel sheets, and materials for industrial facilities. While hot dip galvanizing has the advantage of stability and economic feasibility, it has difficulty in repairing equipment and maintaining the facilities due to high-temperature oxidation caused by Zn Fume where molten zinc used in the open spaces. Currently, SM45C (carbon steel plate for mechanical structure, KS standard) is used for the equipment. If a part of the equipment is resistant to high temperature and Zn fume, it is expected to improve equipment life and performance. In this study, the manufactured Ni alloy was tested for its corrosion resistance against Zn fume when it was used in the hot dip galvanizing equipment in the steel plant. Two kinds of materials currently used in the equipment, new Ni alloy and Inconel(typical corrosion-resistant Ni alloy), were selected as the reference groups. Two kinds of molten metal were used to confirm the corrosion of each alloy according to the molten metal. Zn fume was generated by bubbling Ar gas from molten Zn in a furnace($500{\sim}700^{\circ}C$) and the samples were analyzed after 30 days. After 30 days, the specimens were taken out, the oxide layer on the surface was confirmed with an optical microscope and SEM, and the corrosion was confirmed using a potentiodynamic polarization test. Corrosion depends on the type of molten metal.

A Study on Standardization of Test Method for Water Vapour Permeability of Textiles Fabrics (군용 피복류의 투습도 시험방법 표준화 연구)

  • Lee, Min-Hee;Hong, Seong-Don;Chung, Il-Han
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.10
    • /
    • pp.27-33
    • /
    • 2016
  • Military textiles with breathable waterproof materials are expanding as form of winter clothes. Waterproof moisture-permeable clothes are very important for soldiers to survive in cold weather operations because they prevent loss of body heat from the penetration of water into the human body. Korea military uses the water resistance and moisture permeability to test the performance of waterproof moisture-permeable materials. Moisture permeability is measured according to the amount of evaporated water vapor passing through a fabric under specified temperature and humidity by using acetic acid potassium presented in KS K 0594. However, the test procedure for measuring the moisture permeability in the standard is presented only briefly and the preparation procedures for the test in accredited testing institutions are applied differently, leading to significant deviation of the results. This paper compares the procedures of testing institutions and examines the factors that affect moisture permeability. Finally, we propose a procedure to reduce the deviation of results and apply the proposed procedure in testing institutions. Our analysis results with one-way ANOVA under significant level (0.05) confirm that the deviation of results is reduced.