• Title/Summary/Keyword: Performance Standard

Search Result 6,942, Processing Time 0.04 seconds

A Study on the Standard and Classification of Impact Sound Insulation Performance for Apartment House(II) (바닥 衝擊音 遮音性能基準 및 等級化에 관한 硏究(Ⅱ))

  • Kim, Sun-Woo;Son, Chul-Bong;Song, Yong-Sik;Jang, Gil-Soo;Lee, Tae-Kang;Kook, Chan;Kim, Jae-Soo;Han, Myung-Ho
    • The Journal of the Acoustical Society of Korea
    • /
    • v.9 no.4
    • /
    • pp.5-17
    • /
    • 1990
  • This study aims to establish the appropriate class and standards of sound insulation performance, which are suitable for domestic conditions. For, these purpose, field surveys were conducted, correlationship between subjective response and impact sound insulation performance and then, the applicability of ISO and JIS evaluation method was reviewed. As a result, the JISs method is more advisable than the ISO to evaluate Impact sound insulation performance of domestic apartment house and it is desirable to use both light and heavy weight source (tapping machine, tire) as standard impact sources. And, whether including 63Hz bandwidth or not, the difference was recognized very small in calculating impact sound insulation index of JIS A 1419.

  • PDF

A Study on the Characteristics of Sound Insulation between Rooms in Apartment Houses (공동주택의 실간차음성능 특성에 관한 연구)

  • Lee, Sang-Woo;Jeong, Dae-Up;Kim, Heung-Sik;Kim, Ha-Geun
    • The Journal of the Acoustical Society of Korea
    • /
    • v.11 no.2
    • /
    • pp.50-58
    • /
    • 1992
  • To improve the quality of dwelling environment of domestic apartment house, it is required to establish the sound insulation standard and the performance evaluation method which is suitable to the domestic residential conditions. In this study, the properties of internal noisy sources of a single unit in apartment houses and the sound insulation performance of party walls are investigated and analyzed, as a primary step to the establishment of sound insulation standard. Based on these data, the differences in sound insulation index of each plane type are investigated along with their causes. Also, the factor which affect and decide the insulation performance are analyzed in an effort to improve the performance of party wall structures.

  • PDF

Effects of Trim on Resistance Performance of a Ship (선박의 트림 자세가 저항 성능에 미치는 영향)

  • Park, Dong Woo;Lee, Sang Bong;Chung, Sung Seob;Seo, Heung Won;Kwon, Jae-Woong
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.50 no.2
    • /
    • pp.88-94
    • /
    • 2013
  • The primary objective of the current work is to obviously analyze regarding effects of trim conditions of a ship on resistance performance using model test and CFD. Model tests at a towing tank are conducted to investigate resistance for trim conditions at the given same displacement. Measured resistance shows small but distinct differences according to trim conditions. However, these differences are difficult to be clarified by measured physical quantities and wave pattern analysis from model tests. CFD is employed for the assessment of resistance performance according to trim conditions. The flow computation is conducted considering free surface and dynamic trim using a commercial CFD code (STAR-CCM+). The initiative of the present work is to systematically demonstrate pressure resistance acting on each region of divided finite zones of ship surface along the length and draught direction of surface when pressure distribution on the ship is interpreted. Also, a standard to assess the pressure resistance applied on the divided regions of a ship is established.

An Experimental Study on the Evaluation of Fire-Resist Performance of High-Strength Concrete Filled steel Tube Column at Fire (화재가열을 받은 고강도 콘크리트를 충전한 CFT 기둥의 내화성능 평가에 관한 실험적 연구)

  • Lee, Hyoung-Jun;Lee, Tae-Gyu;Kim, Young-Sun;Han, Hee-Chul;Kim, Gyu-Yong;Kim, Moo-Han
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2008.05a
    • /
    • pp.193-197
    • /
    • 2008
  • Recently, it increases in use of CFT(Concrete filled steel tube, below CFT) that is an excellent internal force and deformation capacity because material and method are required to be diversification and High-Performance according to increase the super-high structure. And it is proposed to use high-strength Concrete Filled steel Tube Column. But it is difficult quantitative evaluation about fire-resist performance of CFT because steel tube bind concrete. Also, the case of high strength CFT is feared that spalling occur inside. Therefore, this study made CFT specimen that determine the factor(which is strength of concrete) and then CFT column was exposed to heating controlled as closely as possible the ISO-834 standard fire curve. Also, it tried to analyze internal temperature through nonlinear transient heat flow analysis.

  • PDF

Developing a Performance Appraisal Tool for Neonatal Intensive Care Unit Registered Nurses (신생아중환자실 간호사 업무수행 평가도구 개발)

  • Park, Kwang-Ok;Lee, Yoon-Young
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.17 no.2
    • /
    • pp.267-276
    • /
    • 2011
  • Purpose: This study was done to develop a performance appraisal tool (PAT) for neonatal intensive care unit (NICU) registered nurses (RNs). Methods: The PAT was developed in three steps: 1) a standard of NICU nursing was established; 2) a draft was made; and 3) the PAT was ratified and its reliability and validity were tested. Results: The standard of practice of NICU nursing was predominantly based on role description and responsibilities for nurses. We identified 4 domains of nursing: professional practice, education, research, and leadership. The validity score for each item ranged from 3.93 to 3.27. The PAT consisted of 76 indicators, 49 reflecting components of professional practice, 5 related to responsibility for education, 3 representing research, and 19 relating to leadership. Cronbach's ${\alpha}$ averaged 0.99 for the 76 items. Conclusions: The PAT for NICU RNs that we created was found to be reliable and valid. This PAT would be very useful in evaluating nursing performance and facilitate the professional growth of nurses.

A Study on the Seismic Protection Performance of Press Fittings for Light Gauge Stainless Steel Pipes (일반배관용 스테인리스강관에 대한 프레스식 관이음쇠의 내진성능에 관한 연구)

  • Baek, Yeal-Sun;Nam, Jun-Seok
    • Fire Science and Engineering
    • /
    • v.31 no.4
    • /
    • pp.65-70
    • /
    • 2017
  • The seismic performance of press fittings is studied, which is one of the weldless joints of stainless steel pipe used in the water piping of recent fire protection system. The piping of this study was constructed based on the piping connection reference of NFPA 13. The permissible displacement of the piping was set as the allowed amount which is given in the Building Structure Standard, and the measurements were repeated 10 times. The Von-mises stress of the piping was 2.48 and 1.25 times of the allowed amount of stress, which was less than the standard, noted three times on the NPPs Allowable Stress for Level D service loading. Therefore, the press fittings shows enough seismic performance.

Contribution of thermal-hydraulic validation tests to the standard design approval of SMART

  • Park, Hyun-Sik;Kwon, Tae-Soon;Moon, Sang-Ki;Cho, Seok;Euh, Dong-Jin;Yi, Sung-Jae
    • Nuclear Engineering and Technology
    • /
    • v.49 no.7
    • /
    • pp.1537-1546
    • /
    • 2017
  • Many thermal-hydraulic tests have been conducted at the Korea Atomic Energy Research Institute for verification of the SMART (System-integrated Modular Advanced ReacTor) design, the standard design approval of which was issued by the Korean regulatory body. In this paper, the contributions of these tests to the standard design approval of SMART are discussed. First, an integral effect test facility named VISTA-ITL (Experimental Verification by Integral Simulation of Transients and Accidents-Integral Test Loop) has been utilized to assess the TASS/SMR-S (Transient and Set-point Simulation/Small and Medium) safety analysis code and confirm its conservatism, to support standard design approval, and to construct a database for the SMART design optimization. In addition, many separate effect tests have been performed. The reactor internal flow test has been conducted using the SCOP (SMART COre flow distribution and Pressure drop test) facility to evaluate the reactor internal flow and pressure distributions. An ECC (Emergency Core Coolant) performance test has been carried out using the SWAT (SMART ECC Water Asymmetric Two-phase choking test) facility to evaluate the safety injection performance and to validate the thermal-hydraulic model used in the safety analysis code. The Freon CHF (Critical Heat Flux) test has been performed using the FTHEL (Freon Thermal Hydraulic Experimental Loop) facility to construct a database from the $5{\times}5$ rod bundle Freon CHF tests and to evaluate the DNBR (Departure from Nucleate Boiling Ratio) model in the safety analysis and core design codes. These test results were used for standard design approval of SMART to verify its design bases, design tools, and analysis methodology.

Development of Standard for Evaluating Performance of Cementitious Scagliola using Statistical Research on Generation Amount of Waste Stone and Waste Stone Powder (우리나라 폐석재, 폐석분 발생량 통계 조사 및 이를 활용한 시멘트계 인조대리석 내·외장재 개발에 따른 성능검증 시험 표준안 개발)

  • Park, Wan-Goo;Kim, Su-Ryon;Heo, Neung-Hoe;An, Ki-Won;Oh, Sang-Keun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.8 no.1
    • /
    • pp.41-48
    • /
    • 2013
  • Waste Stone and Waste Stone Powder are recycling some cyclic aggregate only. And the greater part of Waste Stone and Waste Stone Powder are reclaining or neglecting. To solve this problem, the government is proceeding development of cementitious scagliola using waste stone and waste stone powder. However, quality standard for cementitious scagliola using waste stone and waste stone powder has not been established. So cementitious scagliola using waste stone and waste stone powder has problem of quality assurance. Therefore in this study, developed standard for Evaluating Performance of cementitious scagliola using waste stone and waste stone powder through survey of international standard.

  • PDF

SCTS Conformance Test for OMA DS Standard for an Embedded Data Synchronization Gateway (임베디드 자료동기화 게이트웨이를 위한 OMA DS 표준 SCTS 적합성 테스트)

  • Pak, Ju Geon;Park, Kee Hyun
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.5 no.4
    • /
    • pp.217-224
    • /
    • 2010
  • Nowadays, people perform their tasks anywhere anytime using their mobile devices. For this reason, data synchronization (DS) between mobile devices and a central server has become one of the most essential technologies in mobile environments. Currently, several mobile DS protocols are proposed and used. However, the existing DS protocols cannot guarantee interoperability between them. To solve the problem, an embedded DS gateway has been developed in our previous study. The gateway runs on a Windows Mobile-based emulator. It converts data on a mobile device into common data specified by OMA DS standard protocol and vice versa. The embedded gateway has been built to support the OMA DS standard protocol. In order to verify that the embedded gateway conforms to the OMA DS standard protocol, two kinds of OMA conformance tests have to be conducted - interoperability test with an OMA DS-based server and conformance test with SCTS (SyncML Conformance Test Suit). In this paper, some parts of the gateway previously built are modified and the modified gateway is installed on a Windows Mobile-based smart phone. And the interoperability test and the conformance test with the SCTS are conducted. The results of the tests show that the embedded DS gateway operates properly on the Windows Mobile-based smart phone and that the gateway passes the tests, verifying its conformity to the OMA DS standard protocol. In addition, DS performance tests show that DS delay times between a real smart phone and a DS server increase gently as the number of DS data increases. In other words, the embedded DS gateway built in this paper can be used for a real smart phone at a reasonable performance cost.

Development of an Portable Urine Glucose Monitoring System (휴대용 뇨당 측정 시스템의 개발)

  • 박호동;이경중;윤형로
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.5
    • /
    • pp.397-403
    • /
    • 2002
  • Urine glucose monitoring system is a self-monitoring system that display the glucose level by non-invasive measurement method. In this paper, We developed a noninvasive urine glucose monitoring system that improved defects of urine glucose measurement with a colorimeter method and invasive blood glucose measurement method. This system consist of bio-chemical sensor for urine glucose measurements, signal detecting part, digital and signal analysis part, display part and power supplying part. The developed bio-chemical sensor for the measurement of urine glucose has good reproducibility, convenience of handing and can be mass-produced with cheap price. To evaluate the performance of the developed system, We performed the evaluation of confidence about the detection of glucose level by a comparison between a standard instrument in measuring glucose level and the developed system using standard glucose solutions mixed with urine. Standard error was 2.85282 from the evaluation of confidence based on regression analysis. Also, In analysis of S.D(standard deviation) and C.V(coefficient of validation) that are important parameters to evaluate system using bio-chemical sensor, S.D was 10% which falls under clinically valid value, 15%, and C.V was under 5%. Consequently from the above results, compared to blood glucose measurement, the system performance is satisfactory.