• Title/Summary/Keyword: Performance Reference Model

Search Result 1,069, Processing Time 0.027 seconds

A Study on Development of Achievement Standards and Assessment Standards of Vocational Inquiry Section for 2005 College Scholastic Ability Test - Focus on Food and Nutrition Subject in the Field of Home Economics Order - (2005 수능 직업탐구영역의 과목별 성취기준과 평가기준 개발 - 식품과 영양 과목을 중심으로 -)

  • Na Hyeon-Ju;Min Kyung-Hee;Lee Hwa-young;Pyo Jum-sun;Ha Mi-ok;Jang Myung-Hee
    • Journal of Korean Home Economics Education Association
    • /
    • v.17 no.2
    • /
    • pp.197-219
    • /
    • 2005
  • This study attempted, in accordance with the National Educational Curriculum, to develop achievement assessment standards for a course within the field of home economics which has been widely adopted by Korean vocational high schools, namely, the food and nutrition subject. Focus was also placed on strengthening the management of the curriculum for this food and nutrition course, as well as on establishing proper assessment standards by developing model assessment tools which can be used to assess the subject. The results of this study can be summarized as follows : First, based on an analysis of the related literature and materials. the desired notion of the achievement and assessment standards was established, and their significance ascertained the achievement and assessment standards for the food and nutrition course were set and the type of model assessment tool which should be developed, as well as the method in which it should be applied. was established Second. by analyzing the curriculums and the contents of the textbooks used in the food and nutrition subject, the researcher was able to compile the 70 factors which could to be used to develop the achievement and assessments standards, and then classify these into 6 main categories and 32 sub-categories. Based on the characteristics of these factors and learners' academic performance levels the number of factors was expanded to 89 in order to establish the achievement standards. In turn, these achievement standards were used, in accordance with the learners' achievement and teaming activity levels, to develop three different levels of assessment standards. namely, upper, middle, and lower ones. Third. a model assessment tool was developed which could be used by individual school units as a reference in terms of achievement and assessment standards, and that could be modified to meet each school's circumstances. In order to create the model assessment tool a 100-question questionnaire was formulated that contained various types of questions, such as essay, report, theoretical and practical, portfolio, as well as multiple choice-type questions. Lastly, the researcher introduced measures to effectively use the achievement and assessment standards developed for the food and nutrition course, as well as the model assessment tool in school units.

  • PDF

Evaluation of HbA1c Levels Via the Latex Immunoturbidimetric Method by Using Chemistry Autoanalyzer (자동화학분석기에서의 라텍스 면역비탁법의 Autolab HbA1c 평가)

  • Jo, Yongjun;Lee, So-young;Park, Hae-il;Kim, YeongSic;Lee, Jehoon;Kim, Yonggoo;Han, Kyungja
    • Laboratory Medicine Online
    • /
    • v.2 no.1
    • /
    • pp.10-14
    • /
    • 2012
  • Background: Measurement of HbA1c levels is widely used to diagnose diabetes mellitus and to evaluate and monitor plasma-glucose concentrations over 6-8 weeks. In this study, we evaluated the diagnostic performance of the newly developed latex immunoturbidimetric method by using Autolab HbA1c. Methods: We analyzed and compared the diagnostic performance of Autolab HbA1c with that of Toshiba 200FR between April 2009 and July 2009. According to guidelines (EP5-A2, EP6-P, EP9-A2) of the clinical and laboratory standards institute (CLSI), we compared linearity, precision and correlation of Autolab HbA1c with those of G7 (Tosoh Corp., Kyoto, Japan) by using high-performance liquid chromatography (HPLC) method. Results: Data obtained using Autolab HbA1c showed good linearity in mixtures of samples with low (3.1%) and high (15.1%) levels of HbA1c (r2=0.9997). In the analysis of within-run precision of the samples with HbA1c levels of 5.1% and 12.1%, the SDs were 0.04 and 0.06 and covariances of these samples were 0.8% and 0.5%, respectively. In the Deming regression model, the regression equation was as follows: Autolab HbA1c=1.0859×Tosoh HPLC-0.6957. Conclusions: In this study, Autolab HbA1c method showed better performance characteristics than Tosoh G7 did. In reference review, there was no interference of variant hemoglobin. The data acquisition time of Autolab HbA1c was lower than that of Tosoh G7. The advantages of Autolab HbA1c are that it can be used as an autoanlyzer in routine chemical analysis, it does not require pre-analytical treatment, and the samples are automatically treated with distilled water for hemolysis.

Improvements for Atmospheric Motion Vectors Algorithm Using First Guess by Optical Flow Method (옵티컬 플로우 방법으로 계산된 초기 바람 추정치에 따른 대기운동벡터 알고리즘 개선 연구)

  • Oh, Yurim;Park, Hyungmin;Kim, Jae Hwan;Kim, Somyoung
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.5_1
    • /
    • pp.763-774
    • /
    • 2020
  • Wind data forecasted from the numerical weather prediction (NWP) model is generally used as the first-guess of the target tracking process to obtain the atmospheric motion vectors(AMVs) because it increases tracking accuracy and reduce computational time. However, there is a contradiction that the NWP model used as the first-guess is used again as the reference in the AMVs verification process. To overcome this problem, model-independent first guesses are required. In this study, we propose the AMVs derivation from Lucas and Kanade optical flow method and then using it as the first guess. To retrieve AMVs, Himawari-8/AHI geostationary satellite level-1B data were used at 00, 06, 12, and 18 UTC from August 19 to September 5, 2015. To evaluate the impact of applying the optical flow method on the AMV derivation, cross-validation has been conducted in three ways as follows. (1) Without the first-guess, (2) NWP (KMA/UM) forecasted wind as the first-guess, and (3) Optical flow method based wind as the first-guess. As the results of verification using ECMWF ERA-Interim reanalysis data, the highest precision (RMSVD: 5.296-5.804 ms-1) was obtained using optical flow based winds as the first-guess. In addition, the computation speed for AMVs derivation was the slowest without the first-guess test, but the other two had similar performance. Thus, applying the optical flow method in the target tracking process of AMVs algorithm, this study showed that the optical flow method is very effective as a first guess for model-independent AMVs derivation.

Analysis of Optimal Resolution and Number of GCP Chips for Precision Sensor Modeling Efficiency in Satellite Images (농림위성영상 정밀센서모델링 효율성 재고를 위한 최적의 해상도 및 지상기준점 칩 개수 분석)

  • Choi, Hyeon-Gyeong;Kim, Taejung
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.6_1
    • /
    • pp.1445-1462
    • /
    • 2022
  • Compact Advanced Satellite 500-4 (CAS500-4), which is scheduled to be launched in 2025, is a mid-resolution satellite with a 5 m resolution developed for wide-area agriculture and forest observation. To utilize satellite images, it is important to establish a precision sensor model and establish accurate geometric information. Previous research reported that a precision sensor model could be automatically established through the process of matching ground control point (GCP) chips and satellite images. Therefore, to improve the geometric accuracy of satellite images, it is necessary to improve the GCP chip matching performance. This paper proposes an improved GCP chip matching scheme for improved precision sensor modeling of mid-resolution satellite images. When using high-resolution GCP chips for matching against mid-resolution satellite images, there are two major issues: handling the resolution difference between GCP chips and satellite images and finding the optimal quantity of GCP chips. To solve these issues, this study compared and analyzed chip matching performances according to various satellite image upsampling factors and various number of chips. RapidEye images with a resolution of 5m were used as mid-resolution satellite images. GCP chips were prepared from aerial orthographic images with a resolution of 0.25 m and satellite orthogonal images with a resolution of 0.5 m. Accuracy analysis was performed using manually extracted reference points. Experiment results show that upsampling factor of two and three significantly improved sensor model accuracy. They also show that the accuracy was maintained with reduced number of GCP chips of around 100. The results of the study confirmed the possibility of applying high-resolution GCP chips for automated precision sensor modeling of mid-resolution satellite images with improved accuracy. It is expected that the results of this study can be used to establish a precise sensor model for CAS500-4.

A Study on the Retrieval of River Turbidity Based on KOMPSAT-3/3A Images (KOMPSAT-3/3A 영상 기반 하천의 탁도 산출 연구)

  • Kim, Dahui;Won, You Jun;Han, Sangmyung;Han, Hyangsun
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.6_1
    • /
    • pp.1285-1300
    • /
    • 2022
  • Turbidity, the measure of the cloudiness of water, is used as an important index for water quality management. The turbidity can vary greatly in small river systems, which affects water quality in national rivers. Therefore, the generation of high-resolution spatial information on turbidity is very important. In this study, a turbidity retrieval model using the Korea Multi-Purpose Satellite-3 and -3A (KOMPSAT-3/3A) images was developed for high-resolution turbidity mapping of Han River system based on eXtreme Gradient Boosting (XGBoost) algorithm. To this end, the top of atmosphere (TOA) spectral reflectance was calculated from a total of 24 KOMPSAT-3/3A images and 150 Landsat-8 images. The Landsat-8 TOA spectral reflectance was cross-calibrated to the KOMPSAT-3/3A bands. The turbidity measured by the National Water Quality Monitoring Network was used as a reference dataset, and as input variables, the TOA spectral reflectance at the locations of in situ turbidity measurement, the spectral indices (the normalized difference vegetation index, normalized difference water index, and normalized difference turbidity index), and the Moderate Resolution Imaging Spectroradiometer (MODIS)-derived atmospheric products(the atmospheric optical thickness, water vapor, and ozone) were used. Furthermore, by analyzing the KOMPSAT-3/3A TOA spectral reflectance of different turbidities, a new spectral index, new normalized difference turbidity index (nNDTI), was proposed, and it was added as an input variable to the turbidity retrieval model. The XGBoost model showed excellent performance for the retrieval of turbidity with a root mean square error (RMSE) of 2.70 NTU and a normalized RMSE (NRMSE) of 14.70% compared to in situ turbidity, in which the nNDTI proposed in this study was used as the most important variable. The developed turbidity retrieval model was applied to the KOMPSAT-3/3A images to map high-resolution river turbidity, and it was possible to analyze the spatiotemporal variations of turbidity. Through this study, we could confirm that the KOMPSAT-3/3A images are very useful for retrieving high-resolution and accurate spatial information on the river turbidity.

Design of FPGA Camera Module with AVB based Multi-viewer for Bus-safety (AVB 기반의 버스안전용 멀티뷰어의 FPGA 카메라모듈 설계)

  • Kim, Dong-jin;Shin, Wan-soo;Park, Jong-bae;Kang, Min-goo
    • Journal of Internet Computing and Services
    • /
    • v.17 no.4
    • /
    • pp.11-17
    • /
    • 2016
  • In this paper, we proposed a multi-viewer system with multiple HD cameras based AVB(Audio Video Bridge) ethernet cable using IP networking, and FPGA(Xilinx Zynq 702) for bus safety systems. This AVB (IEEE802.1BA) system can be designed for the low latency based on FPGA, and transmit real-time with HD video and audio signals in a vehicle network. The proposed multi-viewer platform can multiplex H.264 video signals from 4 wide-angle HD cameras with existed ethernet 1Gbps. and 2-wire 100Mbps cables. The design of Zynq 702 based low latency to H.264 AVC CODEC was proposed for the minimization of time-delay in the HD video transmission of car area network, too. And the performance of PSNR(Peak Signal-to-noise-ratio) was analyzed with the reference model JM for encoding and decoding results in H.264 AVC CODEC. These PSNR values can be confirmed according the theoretical and HW result from the signal of H.264 AVC CODEC based on Zynq 702 the multi-viewer with multiple cameras. As a result, proposed AVB multi-viewer platform with multiple cameras can be used for the surveillance of audio and video around a bus for the safety due to the low latency of H.264 AVC CODEC design.

Performance of a Bayesian Design Compared to Some Optimal Designs for Linear Calibration (선형 캘리브레이션에서 베이지안 실험계획과 기존의 최적실험계획과의 효과비교)

  • 김성철
    • The Korean Journal of Applied Statistics
    • /
    • v.10 no.1
    • /
    • pp.69-84
    • /
    • 1997
  • We consider a linear calibration problem, $y_i = $$\alpha + \beta (x_i - x_0) + \epsilon_i$, $i=1, 2, {\cdot}{\cdot},n$ $y_f = \alpha + \beta (x_f - x_0) + \epsilon, $ where we observe $(x_i, y_i)$'s for the controlled calibration experiments and later we make inference about $x_f$ from a new observation $y_f$. The objective of the calibration design problem is to find the optimal design $x = (x_i, \cdots, x_n$ that gives the best estimates for $x_f$. We compare Kim(1989)'s Bayesian design which minimizes the expected value of the posterior variance of $x_f$ and some optimal designs from literature. Kim suggested the Bayesian optimal design based on the analysis of the characteristics of the expected loss function and numerical must be equal to the prior mean and that the sum of squares be as large as possible. The designs to be compared are (1) Buonaccorsi(1986)'s AV optimal design that minimizes the average asymptotic variance of the classical estimators, (2) D-optimal and A-optimal design for the linear regression model that optimize some functions of $M(x) = \sum x_i x_i'$, and (3) Hunter & Lamboy (1981)'s reference design from their paper. In order to compare the designs which are optimal in some sense, we consider two criteria. First, we compare them by the expected posterior variance criterion and secondly, we perform the Monte Carlo simulation to obtain the HPD intervals and compare the lengths of them. If the prior mean of $x_f$ is at the center of the finite design interval, then the Bayesian, AV optimal, D-optimal and A-optimal designs are indentical and they are equally weighted end-point design. However if the prior mean is not at the center, then they are not expected to be identical.In this case, we demonstrate that the almost Bayesian-optimal design was slightly better than the approximate AV optimal design. We also investigate the effects of the prior variance of the parameters and solution for the case when the number of experiments is odd.

  • PDF

Multiscale Modeling and Simulation of Direct Methanol Fuel Cell (직접메탄올 연료전지의 Multiscale 모델링 및 전산모사)

  • Kim, Min-Su;Lee, Young-Hee;Kim, Jung-Hwan;Kim, Hong-Sung;Lim, Tae-Hoon;Moon, Il
    • Membrane Journal
    • /
    • v.20 no.1
    • /
    • pp.29-39
    • /
    • 2010
  • This study focuses on the modeling of DMFC to predict the characteristics and to improve its performance. This modeling requires deep understanding of the design and operating parameters that influence on the cell potential. Furthermore, the knowledge with reference to electrochemistry, transport phenomena and fluid dynamics should be employed for the duration of mathematical description of the given process. Considering the fact that MEA is the nucleus of DMFC, special attention was made to the development of mathematical model of MEA. Multiscale modeling is comprised of process modeling as well as a computational fluid dynamics (CFD) modeling. The CFD packages and process simulation tools are used in simulating the steady-state process. The process simulation tool calculates theelectrochemical kinetics as well as the change of fractions, and at the same time, CFD calculates various balance equations. The integrated simulation with multiscal modeling explains experimental observations of transparent DMFC.

Sugar composition and glycemic indices of frequently consumed fruits in Korea (우리나라 다빈도 섭취 과일의 당 함량 및 혈당지수에 관한 연구)

  • Ryu, Ji-Hyun;Yim, Jung-Eun;Suk, Wan-Hee;Lee, Han-Song-Yi;Ahn, Hye-Jin;Kim, Young-Seol;Park, Cheon-Seok;Choue, Ryo-Won
    • Journal of Nutrition and Health
    • /
    • v.45 no.2
    • /
    • pp.192-200
    • /
    • 2012
  • Fruits are generally recommended for a balanced meal, as they are good sources of vitamins, minerals, and fiber, which may improve blood glucose control. However, fruits have simple sugars with a wide glycemic index (GI) range. The purpose of this study was to analyze the sugar content and composition and to determine the glycemic indices of the most frequently consumed fruits in Korea, including apple, tangerine, pear, water melon, persimmon, grape, oriental melon, and peach. The sugar content and composition of the fruits were analyzed by high performance anion-exchange chromatography (Dinonex model DX-600). The GI of the fruits was measured in 13 healthy subjects (seven females and six males) after permission was received from the University Hospital institutional review board (KHU-IRB 1114-06). The subjects consumed 50 g of glucose as a reference and carbohydrate portions of eight fruits. Blood samples were collected at 0, 30, 60, 90, and 120 min after consuming the fruits. The GI values for the fruits were calculated by expressing the increase in the area under the blood glucose response curve for each subject. As a result, the total sugar contents of 100 g fruits were: grape (13.9 g), apple (12.3 g), persimmon (11.9 g), oriental melon (11.2 g), watermelon (9.3 g), tangerine (8.9 g), peach (8.6 g), and pear (8.3 g). The GI values of the fruits were as follows: GI value of peach ($56.5{\pm}14.17$), watermelon ($53.5{\pm}18.07$), oriental melon ($51.2{\pm}18.14$), tangerine ($50.4{\pm}15.16$), grape ($48.1{\pm}14.05$), persimmon ($42.9{\pm}18.92$), pear ($35.7{\pm}14.38$), and apple ($33.5{\pm}11.92$). These findings will help individuals choose fruit for controlling blood sugar.

Estimated Soft Information based Most Probable Classification Scheme for Sorting Metal Scraps with Laser-induced Breakdown Spectroscopy (레이저유도 플라즈마 분광법을 이용한 폐금속 분류를 위한 추정 연성정보 기반의 최빈 분류 기술)

  • Kim, Eden;Jang, Hyemin;Shin, Sungho;Jeong, Sungho;Hwang, Euiseok
    • Resources Recycling
    • /
    • v.27 no.1
    • /
    • pp.84-91
    • /
    • 2018
  • In this study, a novel soft information based most probable classification scheme is proposed for sorting recyclable metal alloys with laser induced breakdown spectroscopy (LIBS). Regression analysis with LIBS captured spectrums for estimating concentrations of common elements can be efficient for classifying unknown arbitrary metal alloys, even when that particular alloy is not included for training. Therefore, partial least square regression (PLSR) is employed in the proposed scheme, where spectrums of the certified reference materials (CRMs) are used for training. With the PLSR model, the concentrations of the test spectrum are estimated independently and are compared to those of CRMs for finding out the most probable class. Then, joint soft information can be obtained by assuming multi-variate normal (MVN) distribution, which enables to account the probability measure or a prior information and improves classification performance. For evaluating the proposed schemes, MVN soft information is evaluated based on PLSR of LIBS captured spectrums of 9 metal CRMs, and tested for classifying unknown metal alloys. Furthermore, the likelihood is evaluated with the radar chart to effectively visualize and search the most probable class among the candidates. By the leave-one-out cross validation tests, the proposed scheme is not only showing improved classification accuracies but also helpful for adaptive post-processing to correct the mis-classifications.