• Title/Summary/Keyword: Performance Experiment and Evaluation

Search Result 1,145, Processing Time 0.033 seconds

Performance Evaluation of Low Power Communication Techniques Coverage for Internet of Things (IoT를 위한 저전력 통신 기술의 성능 평가)

  • Yoon, JeongHyeon;Kim, Seungku
    • Journal of Korea Multimedia Society
    • /
    • v.24 no.9
    • /
    • pp.1211-1223
    • /
    • 2021
  • Internet of Things(IoT) services have increased the demand for connectivity among electronics devices. As a result, various types of novel wireless communication technologies have been standardized and developed. In this paper, we evaluate the performance of low power wireless communication technologies such as Bluetooth, IEEE 802.15.4, DASH 7, IEEE 802.15.4g, LoRa, and SigFox in various environments. This is the first experiment evaluating various low power wireless communication technologies in real testbed. We expect that the evaluation results will be useful data to other researchers in applying the IoT technology in the future.

Prediction of Human Performance Time to Find Objects on Multi-display Monitors using ACT-R Cognitive Architecture

  • Oh, Hyungseok;Myung, Rohae;Kim, Sang-Hyeob;Jang, Eun-Hye;Park, Byoung-Jun
    • Journal of the Ergonomics Society of Korea
    • /
    • v.32 no.2
    • /
    • pp.159-165
    • /
    • 2013
  • Objective: The aim of this study was to predict human performance time in finding objects on multi-display monitors using ACT-R cognitive architecture. Background: Display monitors are one of the representative interfaces for interaction between people and the system. Nowadays, the use of multi-display monitors is increasing so that it is necessary to research about the interaction between users and the system on multi-display monitors. Method: A cognitive model using ACT-R cognitive architecture was developed for the model-based evaluation on multi-display monitors. To develop the cognitive model, first, an experiment was performed to extract the latency about the where system of ACT-R. Then, a menu selection experiment was performed to develop a human performance model to find objects on multi-display monitors. The validation of the cognitive model was also carried out between the developed ACT-R model and empirical data. Results: As a result, no significant difference on performance time was found between the model and empirical data. Conclusion: The ACT-R cognitive architecture could be extended to model human behavior in the search of objects on multi-display monitors.. Application: This model can help predicting performance time for the model-based usability evaluation in the area of multi-display work environments.

A basic study for the development of Integrated Seakeeping Performance Evaluation System on board the ship (선박탑재용 종합내항성능 평가시스템 개발을 위한 기초적 연구)

  • 조익순;이충로;김순갑
    • Journal of the Korean Institute of Navigation
    • /
    • v.24 no.3
    • /
    • pp.103-111
    • /
    • 2000
  • From a ship's safe operation point of view, it is very important to estimate the navigational safety in a seaway. The seakeeping performance can be defined as the ability of a ship to go to sea, and to accomplish its missions successfully and safely even in adverse environmental conditions. There are several factors presently adopted for evaluating seakeeping performance. But a hardware of the system considering all these factors has not been developed since some of them can not be measured by sensors. In this paper, a synthetic method of evaluating navigational safety is developed by measuring the vertical and lateral acceleration. An experiment by using real measuring carried out on board the T/S 'HANNARA' The equipment was measured every 4 hours for more than 30 minutes the acceleration by accelerometer, analyzed its acceleration values and calculated navigational dangerousness. As the results of this on board experiment, the system is carried conviction to be useful as evaluating seakeeping performance.

  • PDF

The effect of recognition of rubrics on the learning effect of coding education (루브릭의 인지여부가 코딩교육의 학습효과에 미치는 영향)

  • Lee, Aeri;Kim, Changhee
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.13 no.4
    • /
    • pp.201-211
    • /
    • 2017
  • This study provided a rubric prior to the performance of a task in a coding class and aimed to verify its effect. As for the research contents, this study redesigned the rubric developed in the preceding studies for the purpose of this study, presented that to the students and conducted a verification of its effects on the computer efficacy and academic achievement of the students who participated in the experiment, conducting a class. For this purpose, with 41 students in an experimental group, to which the rubric was presented to conduct the class and 39 students in a control group to which the rubric was not presented to conduct the class, this study conducted a six-week class and conducted a survey on their self-efficacy in the computer and a test to measure their academic achievement before and after the experiment. As a result, there were more positive effects on both computer efficacy and academic achievement in the group to which a rubric was presented and in which a rubric evaluation was conducted than in the control group. Through the result of this study, it was noted that the evaluation method presenting more specific and more detailed standards for performance and the level of the standards would have positive impacts on the learners' learning.

Analysis of Underground RC Structures considering Elastoplastic Interface Element (탄소성 경계면 요소를 고려한 철근콘크리트 지하 구조물의 해석)

  • 남상혁;송하원;변근주
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.471-476
    • /
    • 2001
  • Even though structural performance evaluation techniques for reinforced concrete structures have been improved, there are still many problems in the evaluation of structural performance for underground structures which interacts with surrounding soils. Since experimental evaluation of underground RC structures considering the interaction with the surrounding soil medium is quite difficult to be simulated, the evaluation for underground RC structures using an analytical method can be applied very usefully, For underground structures interacted with surrounding soils, it is important to consider path-dependent RC constitutive model, soil constitutive model, and interface model between structure and soil, simultaneously. In this paper, an elastoplastic interface model which consider thickness was proposed and importance of interface model is discussed. The effects of stiffness of structures to entire underground RC system are investigated through numerical experiment for underground RC structure for different reinforcement ratios and thickness of interfaces.

  • PDF

A Study of Fire Extinguishment Characteristic for the Real Scale Deap-Seated Fire (실규모 심부화재 소화특성에 관한 연구)

  • Kim, Nam-Kyun;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.29 no.2
    • /
    • pp.13-19
    • /
    • 2015
  • Real scale fire tests was carried out for extinguishing performance evaluation of the wetting agent. The experiment was conducted in accordance with a Class A fire extinguishing test methods specified in the 'Type Approval of the Manual System Fire Extinguisher and Technical Standards of Test'. In addition, the subjects of this experiment were the wood flour and rice husk. Fire-fighting water, the three kinds of wetting agents used in the country and this study was used, was undertaken to determine a clear discrimination of the water and wetting agent. In the experimental results, it was confirmed that the internal temperature is maintained long time in the case of water. The internal temperature were rapidly lowered in the experiment of wetting agents. Therefore, the discrimination of extinguishing ability was confirmed by the temperature distribution in accordance with time. Based on the results of this experiment, this study is expected to be used as a underlying material on presenting a method of optimized performance evaluation of wetting extinguishing agent.

A Study on Shear and Flexural Performance Evaluation of Circularly Corrugated Plate (원형 파형강판의 전단 및 휨 성능평가에 관한 연구 -전단 및 휨강도 설계식 제안-)

  • Moon, Seong Hwan;Oh, Sang Hoon
    • Journal of Korean Society of Steel Construction
    • /
    • v.27 no.5
    • /
    • pp.455-470
    • /
    • 2015
  • This research suggest method to calculate more accurate shearing and bending force on corrugated steel plate that it is produced domestically. This research analyze limitation of former formula on domestic design standard and existing research. In addition The strength calculation formula on corrugated steel plate was proposed according to result of the experiment and FEM analysis. In this study, the result that compare experiment with analysis using the proposed shear buckling coefficient and limit width to thickness ratio indicate similar behavior. As the result of the research, It is judged that the structural member design and performance evaluation of the corrugated steel plate was conveniently applied.

Shaking Table Test for Seismic Performance Evaluation of Non-Seismic Designed Wall-Type Apartment (내진설계 되지 않은 공동주택의 진동대 실험에 의한 내진성능 평가)

  • Chung, Lan;Lee, Joung-Woo;Park, Tae-Won
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.6 s.96
    • /
    • pp.721-728
    • /
    • 2006
  • Earthquakes are reported thai building structures have been colossal damaged, but before 1988 designed structures which were not applicate seismic design code have no seismic performance. Especially, for the apartment structures were indicated that it have no resist wall element of earthquake before 1988 designed structures. We have to evaluate for seismic performance this structures, therefore it will be retrofitted for seismic index sufficient structures. We performed seismic performance evaluation for model structures by MIDAS which is general structure analysis software. In this study, it was performed shaking table test to evaluate model structure which is reinforcement concrete and 5 floors for seismic performance index. We made specimens by similar's law and tested shaking table test. In the shaking table test it is not performed prototype model test because of space and equipment condition. So we had made scale-down model for 1/5 by similar's law. That's why it needs for the evaluation of performance. However, it is not possible to do an experiment of prototype owing to the shortage of space and the limit of an experimental instrument in the shaking table test. Then, modeling and reducing the part of prototype do the experiment. In this experiment a shaking table test is done and seismic performance of model structures is evaluated by using similitude laws for scale down specimen. As a result it is proved that non-seismic design structures need to retrofit since seismic performance shows life safe grade in 0.12g of an earthquake.

The Performance Evaluation of Red Clay Binder with Polymer Aqueous Solution (고분자수용액을 첨가한 황토 결합재의 성능 평가)

  • Kim, Jin-Sung;Kim, Ho-Jin;Choi, Hyeong-Gil
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.11a
    • /
    • pp.141-142
    • /
    • 2020
  • In this study, the performance evaluation was performed by adding a polymer aqueous solution as a new additive of the red clay binder for use in the rammed earth construction method. The evaluation items were compressive strength and microstructure analysis. As a result of the experiment, the performance of the red clay binder was improved by efficiently bonding the silica particles by the polymerized polymer.

  • PDF

Optimal Windows Transmittance by Energy Performance Analysis and Subjective Evaluation in office building (에너지성능분석 및 감성평가에 의한 오피스 창호의 적정 투과율 선정)

  • Kim, Byoung-Soo;Kim, Jung-Shin;Yim, Oh-Yon
    • Journal of the Korean Solar Energy Society
    • /
    • v.24 no.3
    • /
    • pp.73-83
    • /
    • 2004
  • The purpose of this study is to select the optimal transmittance rate of windows in office buildings through subjective evaluation and energy performance analysis(computer simulation program ; DOE 2.1E). The results are as follows ; 1) In the subjective evaluation experiment, minimum transmittance of the glass is GE 30% and LT 70%, but the optimal transmittance rate is concluded in $40%\sim60%$. 2) As a result of the energy performance analysis, it is desirable for the building of consumptive with mainly air-conditioning to make transmittance as 40-60%. 3) Comparing foreign study on minimum and optimal transmittance rate is $25%\sim38%$, the minimum transmittance of this study is almost the same. But for the optimal transmittance rate, 20% more is needed for KOREAN.