• Title/Summary/Keyword: Performance Evaluations

Search Result 881, Processing Time 0.029 seconds

A Study on Development of a Plugging Margin Evaluation Method Taking Into Account the Fouling of Shell-and-Tube Heat Exchangers

  • Hwang, Kyeong-Mo;Jin, Tae-Eun;Kim, Kyung-Hoon
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.11
    • /
    • pp.1934-1941
    • /
    • 2006
  • As the operating time of heat exchangers progresses, fouling caused by water-borne deposits and the number of plugged tubes increase and thermal performance decreases. Both fouling and tube plugging are known to interfere with normal flow characteristics and to reduce thermal efficiencies of heat exchangers. The heat exchangers of Korean nuclear power plants have been analyzed in terms of heat transfer rate and overall heat transfer coefficient as a means of heat exchanger management. Except for fouling resulting from the operation of heat exchangers, all the tubes of heat exchangers have been replaced when the number of plugged tubes exceeded the plugging criteria based on design performance sheet. This paper describes a plugging margin evaluation method taking into account the fouling of shell-and-tube heat exchangers. The method can evaluate thermal performance, estimate future fouling variation, and consider current fouling level in the calculation of plugging margin. To identify the effectiveness of the developed method, fouling and plugging margin evaluations were performed at a component cooling heat exchanger in a Korean nuclear power plant.

A Study on the Development of Fouling and Plugging Margin Evaluation Methods for Shell-and-Tube Heat Exchangers (다관원통형 열교환기의 파울링 및 관막음 여유 평가법)

  • Hwang, Kyeong-Mo;Jin, Tae-Eun
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.55-60
    • /
    • 2003
  • As operating time of heat exchangers progresses, fouling generated by water-borne deposits increases and thermal performance decreases. The fouling is known to interfere with normal flow characteristics and reduce thermal efficiencies of heat exchangers. The heat exchangers of nuclear power plants have been analyzed in terms of the heat flux and heat transfer coefficient at test conditions based on the ASME OM-S/G-Part 2 as a means of heat exchanger management. It is hard to estimate the heat performance trend and to establish the future management plan. This paper describes the fouling evaluation method which can evaluate the thermal performance for heat exchangers and estimate the future fouling variations and the plugging margin evaluation method which can reflect the current fouling level developed in this study. To develop the fouling and plugging margin evaluation methods for heat exchangers, fouling factor was introduced based on the ASME O&M codes and TEMA standards. For the purpose of verifying the two evaluation methods, the fouling and plugging margin evaluations were performed for a component cooling heat exchanger in a nuclear power plant.

  • PDF

Mobile Web Service Architecture Using Context-store

  • Oh, Sang-Yoon;Aktas, Mehmet;Fox, Geoffrey C.
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.4 no.5
    • /
    • pp.836-858
    • /
    • 2010
  • Web Services allow a user to integrate applications from different platforms and languages. Since mobile applications often run on heterogeneous platforms and conditions, Web Service becomes a popular solution for integrating with server applications. However, because of its verbosity, XML based SOAP messaging gives the possible overhead to the less powerful mobile devices. Based on the mobile client's behavior that it usually exchanges messages with Web Service continuously in a session, we design the Handheld Flexible Representation architecture. Our proposed architecture consists of three main components: optimizing message representation by using a data format language (Simple_DFDL), streaming communication channel to reduce latency and the Context-store to store context information of a session as well as redundant parts of the messages. In this paper, we focus on the Context-store and describe the architecture with the Context-store for improving the performance of mobile Web Service messaging. We verify our approach by conducting various evaluations and investigate the performance and scalability of the proposed architecture. The empirical results show that we save 40% of transit time between a client and a service by reducing the message size. In contrast to solutions for a single problem such as the compression or binarization, our architecture addresses the problem at a system level. Thus, by using the Context-store, we expect reliable recovery from the fault condition and enhancing interoperability as well as improving the messaging performance.

Performance Evaluations of the Interpolation Methods Under the various illumination intensities and its Application to the Adaptive Interpolation for Image Sensors (이미지센서를 위한 조도에 따른 보간 기법의 성능 평가와 이를 이용한 가변적 보간 기법)

  • Kim, Byung-Su;Paik, Doo-Won
    • Journal of Internet Computing and Services
    • /
    • v.9 no.1
    • /
    • pp.171-177
    • /
    • 2008
  • In this paper we compared the performance of interpolation algorithms for Bayer patterned image sensors under the various illumination intensities. As the interpolation algorithms, we used bilinear color interpolation and adaptive fuzzy color interpolation and our experimentation shows that performance of interpolation algorithms depend on the lighting conditions; in low intensity of illumination, bilinear color interpolation with median filter performs best, in high intensity of illumination, adaptive fuzzy color interpolation performs best, and in between bilinear color interpolation performs best. This study suggested an interpolation scheme which applies different interpolation algorithm according to the intensity of the input image, resuting in the better image quality.

  • PDF

The Development of Two-Person Janggi Board Game Using Backpropagation Neural Network and Reinforcement Learning (역전파 신경회로망과 강화학습을 이용한 2인용 장기보드게임 개발)

  • Park, In-Kue;Jung, Kwang-Ho
    • Journal of Korea Game Society
    • /
    • v.1 no.1
    • /
    • pp.61-67
    • /
    • 2001
  • This paper describes a program which learns good strategies for two-poison, deterministic, zero-sum board games of perfect information. The program learns by simply playing the game against either a human or computer opponent. The results of the program's teaming of a lot of games are reported. The program consists of search kernel and a move generator module. Only the move generator is modified to reflect the rules of the game to be played. The kernel uses a temporal difference procedure combined with a backpropagation neural network to team good evaluation functions for the game being played. Central to the performance of the program is the search procedure. This is a the capture tree search used in most successful janggi playing programs. It is based on the idea of using search to correct errors in evaluations of positions. This procedure is described, analyzed, tested, and implemented in the game-teaming program. Both the test results and the performance of the program confirm the results of the analysis which indicate that search improves game playing performance for sufficiently accurate evaluation functions.

  • PDF

An Experimental Investigation of Thermodynamic Performance of R-22 Alternative Blends

  • Kim, Chang-Nyeon;Park, Young-Moo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.6
    • /
    • pp.36-44
    • /
    • 1998
  • R-410a and R-407c which have the best potential among R-22 alternatives were tested as drop-in refrigerants against a set of R-22 baseline tests. The performance evaluations were carried out in a psychometric calorimeter test facility using the residential spilt type air conditioner under the ARI rating conditions. Except the lubricant and hand-operated expansion valve, the other parts of the air conditioner were the same with the commercial system. Performance characteristics were measured; compressor power, capacity, VCR, mass flow rate and COP. The tests showed that R-407c can be directly charged into the current refrigeration system because its vapor pressure and other thermochemical properties are similar to those of R-22. However, it is required to change the volume flow rate of compressor in order to achieve the volumetric capacity of R-22. This results from its relatively small VCR and capacity. Meanwhile, R-410a has vapor pressure values too high to be substituted for the current system and this resulted relatively low COP of R-410a compared to that of R-22.

  • PDF

Nutrition Teachers' Perception of the Importance and Performance Frequency of Their Roles in the Indicators and Items on a Teacher Evaluation (교원능력개발평가 영양교사 평가지표와 문항의 중요도 및 수행도에 대한 영양교사들의 인식)

  • Choi, Hee-Jun;Park, Ji-Hye
    • Journal of the Korean Dietetic Association
    • /
    • v.16 no.2
    • /
    • pp.146-159
    • /
    • 2010
  • This study was conducted to determine the appropriateness of the indicators and items on teacher evaluations for professional development and to provide insight for their improvement. To accomplish this, the perception of the importance and performance frequency of 318 nutrition teachers regarding their roles inherent in the indicators and items were evaluated through a survey questionnaire based on a five-point Likert scale. The quantitative data were analyzed using descriptive statistics and a paired t-test. In addition, the reflective analysis and constant comparison method were employed to analyze the responses to the open-ended questions asking problems in the indicators and items. The results revealed that the mean scores for the importance and performance frequency of most indicators and items were over four points, which implies that most indicators and items are appropriate for evaluating the job tasks of nutrition teachers. However, it was suggested that a few items be revised or removed for their improvement and appropriateness. This study concluded that nutrition teachers should have more chances to provide nutrition education for students to enable them to perform as teachers and not simply dietitians.

A study on the Quality Assessment Method on Railway Video Transmission System (철도영상전송시스템의 화질평가방안에 관한 연구)

  • Chang Seok-Gahk;Cho Bong-Kwan
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.1247-1252
    • /
    • 2004
  • A objective quality assessment for the evaluation performance of a video transmission system as a basic step for construction of digital video transmission system between the spots and headquarter. Due to a limit of an analog video transmission system and the developments of various digital media and digital video standards, the need of introduce of a digital system are increased gradual1y, At this points. previously performance evaluations are performed and the quality assessment is the most important thing. We can be divided quality assessment method by the subjective quality assessment and objective quality assessment. The subjective quality assessment method has some problems which are required high cost and much time to evaluate the quality, And because existing objective quality assessment method such that PSNR are based on an analog form, the correlation with subjective data is very low. Therefore we design a new objective quality assessment method using Gabor wavelet transform reflecting HVS(Human Visual System), Designed objective quality assessment method is superior to other objective method such that PSNR or EPSNR In this paper, we proposed objective quality assessment using Gabor wavelet can be used for performance evaluation and verification of video transmission system.

  • PDF

Two-Level Tries: A General Acceleration Structure for Parallel Routing Table Accesses

  • Mingche, Lai;Lei, Gao
    • Journal of Communications and Networks
    • /
    • v.13 no.4
    • /
    • pp.408-417
    • /
    • 2011
  • The stringent performance requirement for the high efficiency of routing protocols on the Internet can be satisfied by exploiting the threaded border gateway protocol (TBGP) on multi-cores, but the state-of-the-art TBGP performance is restricted by a mass of contentions when racing to access the routing table. To this end, the highly-efficient parallel access approach appears to be a promising solution to achieve ultra-high route processing speed. This study proposes a general routing table structure consisting of two-level tries for fast parallel access, and it presents a heuristic-based divide-and-recombine algorithm to solve a mass of contentions, thereby accelerating the parallel route updates of multi-threading and boosting the TBGP performance. As a projected TBGP, this study also modifies the table operations such as insert and lookup, and validates their correctness according to the behaviors of the traditional routing table. Our evaluations on a dual quad-core Xeon server show that the parallel access contentions decrease sharply by 92.5% versus the traditional routing table, and the maximal update time of a thread is reduced by 56.8 % on average with little overhead. The convergence time of update messages are improved by 49.7%.

Performance Evaluation of a Two-Stage Compression Heat Pump System for District Heating (지역난방용 2단 압축 히트펌프 시스템 성능평가)

  • Park, Cha-Sik;Cha, Dong-An;Kwon, Oh-Kyung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.7
    • /
    • pp.585-590
    • /
    • 2012
  • The objective of this study is to investigate the performance of a two-stage compression heat pump system for district heating. The experimental setup of heat pump consists of compressor, condenser, evaporator, expansion device, intercooler, flash tank, oil separator and accumulator. The experimental evaluations on the two-stage compression cycle were carried out under various operating conditions which were heat source temperature, the degree of compressor inlet superheat, and intermediate pressure. The temperature ranges of unutilized energy as the heat source were used in the test conditions. As the heat source temperature increased from $10^{\circ}C$ to $30^{\circ}C$, the COP and heating capacity of the heat pump system increased by 22.6% and 45.8%, respectively. The performance of the two-stage heat pump system increased by 5.2% with the variation of the intermediate pressure in the same heat source temperature conditions.