• Title/Summary/Keyword: Performance Evaluation of Facility

Search Result 329, Processing Time 0.034 seconds

Reliability Design Based on System Performance-Cost Trade-off for Manufacturing facility

  • Hwang, Heung-Suk;Hwang, Gyu-Wan
    • International Journal of Reliability and Applications
    • /
    • v.2 no.4
    • /
    • pp.269-280
    • /
    • 2001
  • The objective of this paper is to provide a model for effective implementation of costing RAM management in the design and procurement of production facility considering the system cost-performance trade-off. This research proposes a two-step approach of costing RAM design and test of system RAM for production facility. In Step 1, a static model is proposed to find an initial system configuration to meet the required performance based on system RAM and LCC and analyzes the trade-off relationships between various factors of RAM and LCC. In the second Step, we developed time and failure truncated models for system reliability test and analysis. For the computational purpose, we developed computer programs and have shown the sample results. By the sample test run, the proposed model has shown the possibilities to provide a good method to analyze system performance evaluation for both design and operational phase, This model can be applied to a wide variety of systems not only for costing RAM of the production facilities but also for the other kinds of equipment.

  • PDF

Axial Turbine Performance Evaluation in a Rotating Facility (회전 환경에서의 축류 터빈 성능평가)

  • Yoon, Yong-Sang;Song, Seung-Jin;Kim, Hong-Won;Cho, Sung-Hee
    • The KSFM Journal of Fluid Machinery
    • /
    • v.4 no.3 s.12
    • /
    • pp.46-52
    • /
    • 2001
  • This paper describes a turbine test program conducted at Seoul National University(SNU). To measure blades' aerodynamic performance, either linear(2-Dimensional) or annular(3-Dimensional) cascades are often used. However, neither cascade can consider effects such as those due to rotation or rotor-stator interaction. Therefore, a rotating test facility for axial turbines has been designed and built at SNU, and its description is given in this paper. The results from an axial turbine performance test are presented. At the design point, the measured efficiency agrees with the efficiency predicted by a meanline analysis. At off design points, however, the measured and predicted efficiencies diverge. The most likely cause is hypothesized to be the inaccuracy of correlations used in the meanline analysis at off design points.

  • PDF

A study on the improvement plan for precision safety diagnosis and seismic repair and reinforcement measures according to seismic performance evaluation (내진성능평가에 따른 정밀안전진단 및 내진 보수보강 조치의 개선방안 연구)

  • Kim, Jang-Ook
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.87-88
    • /
    • 2022
  • For an earthquake-safe urban environment, the Republic of Korea conducts seismic performance evaluation in accordance with laws and guidelines to assign safety ratings and implement necessary management measures such as repairs and reinforcements. In the seismic performance evaluation result, structures lacking in preparation for earthquakes are prioritized and classified into measures such as repair, reinforcement, or careful observation to respond to physical risks such as earthquakes. Such repair and reinforcement work is not a one-time thing, but it is necessary to further enhance the effect through continuous follow-up observation. In this study, the location of the vertical and horizontal displacement measuring part of the construction part is displayed so that the post-construction status of the reinforcement construction part can be visually checked by identifying the problems in the process of post-monitoring in 2022 for the maintenance and reinforcement work of local governments' public facilities carried out in 2021. We propose a plan to institutionalize the installation of, inspection tools, and crack gauges at certain locations in the construction department, and to have facility managers periodically inspect and manage them with a smartphone program or the 'Facility Autonomous Safety Inspection' app.

  • PDF

Design of Compressed Gas Supply System for Combustion Chamber Test Facility (연소기 연소시험설비 고압가스 공급시스템 설계)

  • Chung, Yonggahp;Cho, Namkyung;Han, Yeoungmin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.18 no.1
    • /
    • pp.85-90
    • /
    • 2014
  • To develop liquid propulsion engine, the development of combustion chamber must be preceded. For performance validation of the combustion chamber, the designed and manufactured combustion chamber should be tested in combustion chamber test facility (CCTF). The CCTF is the test facility to develop the combustor of rocket engine, which uses liquid oxygen as a oxidizer and kerosene as a fuel. Present paper introduces the detailed design results of compressed gas supply system of CCTF, which is planned to be installed at Naro Space Center.

Preliminary Design of Liquid Rocket Engine Test Facility (액체로켓엔진 연소시험설비 예비설계)

  • Kim, Seung-Han;Han, Yeoung-Min
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.885-891
    • /
    • 2011
  • This paper describes the results of preliminary design of rocket engine test facility for the performance evaluation of liquid rocket engine. Design specification and composition of rocket engine test facility are suggested based on the design requirements. The results of the preliminary design of rocket engine test facility will be used as base data for the detail design and construction of rocket engine ground test facility of KSLV-II 75tonf liquid rocket engine.

  • PDF

Development of Liquid Rocket Engine Test Facility (한국형발사체 엔진 지상 연소시험설비 개발)

  • Kim, Seung-Han;Chung, Yong-Gap;Han, Yeoung-Min
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2012.05a
    • /
    • pp.479-483
    • /
    • 2012
  • This paper describes the development status of rocket engine test facility for the performance evaluation of liquid rocket engine of KSLV-II 1st stage. Design specification and composition of rocket engine test facility are suggested based on the design requirements. The results of the basic design of rocket engine test facility will be used as base data for the detail design and construction of rocket engine ground test facility of KSLV-II 75tonf liquid rocket engine.

  • PDF

A Study on the Evaluation Method of the Building Safety Performance and the during Building Fires with Computer Prediction of Occupants′ Egress Behavior Simulation (컴퓨터시뮬레이션에 의한 피난행태예측 및 안전성능평가 방법에 관한 연구(I))

  • 최원령;이경회
    • Fire Science and Engineering
    • /
    • v.3 no.1
    • /
    • pp.19-28
    • /
    • 1989
  • It has been recognized that the escape facility planning is very important for effective evacuation of accupants on fire event. The ultimate goal of the escape facility planning is to evacuate occupants rapidly from building fires to the safe areas. In fire event, occupants usually gather, utilize and finally act upon information about state transient of building fire system, which is consisted of components of fire, building and accupant during the ralatively short period of the fire event. That is, occupants' egress behavior is largely dependent upon building fire system. Therefore, comprehensive study for the relationship between building fire system and occupants' egress behavior is needed. This study aims to suggest the pre -occupancy evaluation method of the life safety performance for the architectural design based on prediction of occupants' egress behavior during building fires with computer simulation.

  • PDF

Uncertainty Analysis and Improvement of an Altitude TestFacility for Small Jet Engines

  • Jun, Yong-Min;Yang, In-Young;Kim, Chun-Taek;Yang, Soo-Seok;Lee, Dae-Sung
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.5 no.1
    • /
    • pp.46-56
    • /
    • 2004
  • The verification and improvement of the measurement uncertainty have beenperformed in the altitude test facility for small gas turbine engines, which was built atthe Korea Aerospace Research Institute (KARI) in October 1999. This test is performedwith a single spool turbojet engine at several flight conditions. This paper discussesthe evaluation and validation process for the measurement uncertainty improvements usedin the altitude test facility. The evaluation process, defined as tests before the facilitymodification, shows that the major contnbutors to the measurement uncertainty are theflow meter discharge coefficient, the inlet static and total pressures, the cell pressureand the fuel flow rate. The measurement uncertainty is focused on the primary parametersof the engine performance such as airflow rate, thrust and specific fuel consumption (SFC).The validation process, defined as tests after the facility modification, shows that themeasurement uncertainty, in seal level condition, is tmproved to the acceptable level throughthe facility modification. In altitude test conditions, the measurement uncertainties arenot improved as much as the uncertainty in sea level condition.

Case Study on the Implementation of Facility AI Platform for Small and Medium Enterprises of Korean Root Industry (뿌리업종 중견중소기업의 설비 AI 플랫폼 구축에 관한 사례연구)

  • Lee, Byong Koo;Moon, Tae Soo
    • The Journal of Information Systems
    • /
    • v.32 no.3
    • /
    • pp.205-224
    • /
    • 2023
  • Purpose This study investigates the impact of organizational characteristics on organizational performance through case studies of smart factory implementation in the context of Korean small and medium Enterprises (SMEs). To achieve this goal, this study adopts the smart factory index of KOSMO (Korea Smart Manufacturing Office) established by Korean Ministry of SMEs and Startups. We visited 3 firms implemented smart factory projects. This study presents the results of field study in detail with evaluation criteria on how organizational competences like AI technology adoption and facility automation can be exploited to positively influence organizational performance through smart factory implementation. Design/methodology/approach There are not so many results of empirical studies related to smart factories in Korea. This is because organizational support and user involvement are required for facility AI platform service beyond factory automation after the start of the 4th Industrial Revolution. Korean government's KOSMO (Korean Smart Manufacturing Office) has developed and proposed a level measurement index for smart factory implementation. This study conducts case studies based on the level measurement method proposed by KOSMO in the process of conducting case studies of three companies belonging to the root and mechanic industries in Korea. Findings The findings indicate that organizational competences, such as facility AI platform adoption and user involvement, are antecedents to influence smart factory implementation, while smart factory implementation has significant relationship with organizational performance. This study provides a better understanding of the connection between organizational competences and organizational performance through smart factory case studies. This study suggests that SMEs should focus on enhancing their organizational competences for improving organizational performance through implementing smart factory projects.

The Practical Simplified Equation for Settlement Evaluation of Counter Facility in Soft Ground Centering on Rubble Mound (연약지반에 설치된 항만 외곽시설의 안전점검을 위한 침하 평가 간편식 제안 - 사석경사제 중심으로)

  • Kim, Yong-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.6
    • /
    • pp.317-324
    • /
    • 2020
  • In this study, a simplified equation for settlement evaluation suitable for the special conditions of a counter facility is suggested. Recently, counter facilities, especially breakwaters, are constructed on soft ground in distant seas as new-port development projects. A counter facility that resists the external forces by self-weight settles easily when constructed on soft ground. Settlement in a counter facility and breakwater is not an important factor for maintenance than a land facility. On the other hand, the current settlement evaluation criteria are excessive for conducting a safety inspection. A settlement evaluation from a safety inspection followed by "Detailed Guidelines for a safety inspection on a counter facility" is used. A simplified equation was proposed to calculate the maximum settlement by applying the allowable residual settlement or settlement stability evaluation results. The suitability of the simplified equation was assessed compared to the assessed rating from the settlement survey results. The proposed simplified equation showed that the settlement evaluation rating had been upgraded. The proposed simplified equation is expected to be used to evaluate the practical structural stability and functional performance.