• Title/Summary/Keyword: Performance Evaluation of Facility

Search Result 331, Processing Time 0.033 seconds

An intelligent consultant for mataerial handling equipment selection and evaluation (물자취급장비 선정과 평가를 위한 지능화된 자문시스템)

  • 박양병
    • Korean Management Science Review
    • /
    • v.12 no.1
    • /
    • pp.35-50
    • /
    • 1995
  • The material handling equipment selection, that is a key task in the material handling system design, is a complex, difficult task, and requires a massive technical knowledge and systematic analysis. It is also invaluable to justify the selected equipment model by the performance evaluation before its actual implementation. This paper presents an intelligent knowledge-based expert system called "IMESE" created by author, for the selection and evaluation of material handling equipment model suitable for movement and storage of materials in a manufacturing facility. The IMESE was constructed by using the tools of VP-Expert expert system shell, DBASEIII plus, FORTRAN 77, and SLAMII simulation language. The whole process of IMESE is executed under VP-Expert expert system environment.vironment.

  • PDF

Case Study for Energy Conservation Measures of Hospital Buildings Using the Analysis of Energy Consumption Structure (의료시설 에너지절약 운영방법 도출을 위한 사례분석을 통한 에너지 영향요소 분석)

  • Lee, Sangmoon;Cho, Jinkyun
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.2
    • /
    • pp.57-69
    • /
    • 2019
  • Because the hospital building operates 24 hours a day, 365 days a year for treatment and restoration of patients, it has a different pattern of energy use than that of ordinary buildings. Hospitals contribute to energy consumption and have a negative environmental impact. This study aims to find how meaningful energy performance, reflecting good energy management and ECMs, can be operated for hospital buildings, a category encompassing complex buildings with different systems and large differences between them. In this study, we proposed the energy diagnosis & evaluation method and energy management process to verify energy saving through operation data based on system & facility characteristics, operation pattern and energy consumption characteristics of hospital building. Energy consumption structures were surveyed throughout 4 reference hospital in Seoul, Korea. Findings confirm that different hospital departments have hugely different energy-demand profiles. Energy efficiency and energy saving potentials are presented. The energy performance analysis can be applied to a wide range of problems in energy-system operation.

Development of Evaluation Factors for Breakwater Rehabilitation (방파제 성능개선을 위한 평가항목 개발)

  • Park, Su-Yeul;Yun, Won-Gun;Kang, Go-Une;Kim, Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.4
    • /
    • pp.67-74
    • /
    • 2021
  • Domestically, technical condition evaluation for breakwaters has been conducted through safety checks and safety diagnosis. If necessary, maintenance for the facility is conducted. However, in recent years, the need for infrastructure management has been increasing from a life-cycle-cost perspective. For these reasons, the "Sustainable Infrastructure Management Basic Act" was enacted. Previously, only the technical part of the breakwaters was evaluated. However, based on the act, comprehensive management of breakwaters will be possible through performance improvement by adding economic and political evaluations. In this study, evaluation factors and evaluation methods were developed for a breakwater rehabilitation project. The purpose of this study is to present a development direction, items, and methods for the evaluation of breakwater performance improvement to be applied in future practice. This study reviews the concept of maintenance and performance improvement, the literature related to performance improvement, and the project type for the common standard of performance improvement. Evaluation items and evaluation methods for breakwater rehabilitation are suggested to be reviewed by experts. The methodology suggested in this study could be used for preventive maintenance and to reduce accidents.

Development Test of Alcohol Burner for Turbopump Real-propellant Test Facility (터보펌프 실매질 시험설비를 위한 알코올버너 개발시험)

  • Kim, Jin-Sun;Han, Yeoung-Min;Ko, Youngsung
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.18 no.5
    • /
    • pp.79-86
    • /
    • 2014
  • A turbopump real-propellant test facility(TPTF) is to verify the performance of a turbopump unit(TPU) based on liquid oxygen and kerosene. One of the most important sub-facilities is a hot-gas generation system which makes the driving force of the TPU with an alcohol burner. The alcohol burner generates the required flow rates and temperature at the facility using high pressure air and ethanol. In the study, the verification tests of the alcohol burner which was manufactured entirely with domestic technology were performed and fabrication technique and operation skill for the burner could be obtained ahead of the construction of the facility. Two burners will be operated simultaneously for the real-propellant test of 75tf class turbopump and satisfy the power requirement from the turbine of the TPU.

Development and Application of Performance Indicators to Estimate the Service Activities Relating with Water and Wastewater Works: Focus on Water Works Parts (상하수도 서비스 평가지표 개발 및 적용: 상수도 분야를 중심으로)

  • Choi, Tae-yong;Yoon, Yeo Cheon;Lee, Lan Jung;Kim, Duck-Jin;Jo, Jae Hong;Koo, Ja-yong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.3
    • /
    • pp.411-429
    • /
    • 2006
  • To improve Service quality for water and wastewater works, most water and wastewater utility effort to develop not only facility construction but also operation optimization. The operation is optimized by accurate estimation for ongoing situation. And from the accurate estimation, utility operator gain a information about their service quality and problems, So we developed a evaluation tool (Performance Indicators: PI) for service activity of water and wastewater works. The PI was developed in many countries and some international organizations (World Bank, IWA etc.) for service benchmarking. And ISO (international organization for standardization) just has been making a service standard for water and wastewater system (So called ISO/C224). This proceeding for making a service standard is ongoing now and will be launched in 2007. In our study, PI was composed of 6 parts (A human resource, facility management, operation, service quality, finance and environment). To evaluate water utilities, performance indicators for water was consisted of 100 items. Each 2 water utilities were estimated by this performance indicator. From the study, we just know that the performance indicator was a very useful tool to estimate utility service quality. And from the result, it is possible to know the strong and weak point of estimated utilities.

A Study on the Improvement Direction of RFID Using Satisfaction-Importance Matrix in Construction Fields (만족도-중요도 매트릭스를 이용한 건설현장에서의 RFID 개선 방향에 관한 연구)

  • Jang, Se-Woong;Yu, Hoe-Chan;Kim, Jae-Jun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.9 no.2
    • /
    • pp.47-54
    • /
    • 2009
  • Integrated construction site management using RFID(Radio Frequency Identification) and facility maintenance introducing USN (Ubiquitous Sensor Network) have been widely used in the mega construction project sites. But, the validation on performance of RFID systems after introducing those has not been carried out. Given that the use of RFID systems have been increased, the construction industry as well as other industries needs the evaluation of the RFID system. By regarding the necessities for evaluation, a research to the satisfaction and importance evaluation of RFID system from the end-users' view point for site management was conducted. Satisfaction-importance matrix of satisfaction standards and importance standards was created (organised) according to the analysis result of a survey, proposed improvement methods and analysis about the items presented by each region like areas of sustainable maintenance, maintenance, progressive improvement and priority improvement. The result would contribute to enhance the utilization of system and its performance.

Design and Performance Evaluation of an Assemble-To-Order System (주문- 조립시스템의 설계 및 성능평가)

  • 박찬우;이효성
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.27 no.4
    • /
    • pp.41-65
    • /
    • 2002
  • We study a multi-component production/inventory system in which individual components are made to meet various demand types. We assume that the demands arrive according to a Poisson process, but there is a fixed probability that a demand requests a particular kit of different components. Each component is produced by a flow line with several stations in which the processing times of each station follow a two-stage Coxian distribution. The production of each component is operated by an independent base-stock policy with blocking. We assume that the time needed to assemble final products follows a general distribution and the capacity of an assembling facility is sufficiently large. The objective of this study is to obtain key performance measures such as the distribution of the number of each orders for each final product and the mean time of fulfilling a customer order. The basic principle of the proposed approximation method is to decompose the original system into a set of subsystems, each subsystem being associated with a flow line. Each subsystem is analyzed in isolation using a Marie's method. An iterative procedure is then used to determine the unknown parameters of each subsystem. Numerical results show that the accuracy of the approximation method is acceptable.

Test Facility of Battery Simulator for Dynamic Characteristics and Safety Evaluation in Lithium-ion Battery (리튬이온 배터리 동특성 및 안전성 평가를 위한 배터리 시뮬레이터 시험설비)

  • Sungin Jeong;Yongho Yoon
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.24 no.2
    • /
    • pp.133-138
    • /
    • 2024
  • Lithium-ion batteries are used in many fields due to their high energy density, fast charging conditions, and long cycle life. However, overcharging, over-discharging, physical damage, and use of lithium-ion batteries at high temperatures can reduce battery life and cause damage to people due to fire or explosion due to damage to the protection circuit. In order to reduce the risk of these batteries and improve battery performance, the characteristics of the charging and discharging process must be analyzed and understood. Therefore, in this paper, we analyze the charging and discharging characteristics of lithium-ion batteries using a battery charger and discharger and simulator to reduce the risk of loss of life due to overcharge and overdischarge, as well as casualties from fire and explosion due to damage to the protection circuit.

Performance evaluation of telecommunication protocols using stochastic petri nets reward model (Stochastic Petri Nets Reward Model을 이용한 통신 프로토콜의 성능평가)

  • 로철우;장직현
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.32A no.4
    • /
    • pp.1-14
    • /
    • 1995
  • A new stochastic Petri nets model, called Stochastic Petri Nets Reward Model(SPNRM) is used for modeling and evaluating the performance of telecommunication protocols. We have developed a SPNRM of the TDX-10 Internal protocol, which has a packet data exchange facility between DCEs, Especially a timer and retransmission handling model is presented for error control of the data transmission phase. The stochastic Petri nets package(SPNP), a software package for SPNRM used in this paper, has been used to generate numerical results by analytical-numerical method rather than simulation. From the steady state solution of the net, it is possible to calculate automatically the performance measure of the protocol medeled with both end-to-end and link-by-link method, which are the mean response times and the throughputs.

  • PDF

Hydraulic and hydrologic performance evaluation of low impact development technology

  • Yano, Kimberly Ann;Geronimo, Franz Kevin;Reyes, Nash Jett;Choe, Hye-Seon;Jeon, Min-Su;Kim, Lee-Hyeong
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.325-325
    • /
    • 2020
  • Low impact development (LID) is a widely used technology that aims to reduce the peak flow volume and amount of pollutants in stormwater runoff while introducing physicochemical, biological or a combination of both mechanisms in order to improve water quality. This research aimed to determine the effect of hydrologic factors in removing the pollutants on stormwater runoff by an LID facility. Monitored storm events from 2010-2018 were analysed to evaluate the hydraulic and hydrological performance of a small constructed wetland (SCW). Standard methods for the examination water and wastewater were employed to assess the water quality of the collected samples (APHA et al, 1992). Primary hydrologic data were obtained from the Korea Meteorological Administration. The recorded average rainfall intensity and antecedent dry days (ADD) of SCW were 5.26 mm/hr and 7 days respectively. During the highest rainfall event (27 mm/hr), the removal efficiency of SCW for all the pollutants was ranging from 67% to 91%. While on the lowest rainfall event (0.7 mm/hr), the removal efficiency was ranging from -36% to 62%. Rainfall intensity has a significant effect to the removal efficiencies of each facility due to its dilution factor. In addition to that, there was no significant correlation of ADD to the mean concentrations of pollutants. Generally, stormwater runoff contains significant amount of pollutants that can cause harmful effects to the environment if not treated. Also, the component of this LID facility such as pre-treatment zone, media filters and vegetation contributed to the effectivity of the LID facilities in reducing the amounts of pollutants present in stormwater runof.

  • PDF