• 제목/요약/키워드: Performance Design

검색결과 28,655건 처리시간 0.053초

Performance-based seismic analysis and design of code-exceeding tall buildings in Mainland China

  • Jiang, Huanjun;Lu, Xilin;Zhu, Jiejiang
    • Structural Engineering and Mechanics
    • /
    • 제43권4호
    • /
    • pp.545-560
    • /
    • 2012
  • Design codes provide the minimum requirements for the design of code-compliant structures to ensure the safety of the life and property. As for code-exceeding buildings, the requirements for design are not sufficient and the approval of such structures is vague. In mainland China in recent years, a large number of code-exceeding tall buildings, whether their heights exceed the limit for the respective structure type or the extent of irregularity is violated, have been constructed. Performance-based seismic design (PBSD) approach has been highly recommended and become necessary to demonstrate the performance of code-exceeding tall buildings at least equivalent to code intent of safety. This paper proposes the general methodologies of performance-based seismic analysis and design of code-exceeding tall buildings in Mainland China. The PBSD approach proposed here includes selection of performance objectives, determination of design philosophy, establishment of design criteria for structural components and systems consistent with the desirable and transparent performance objectives, and seismic performance analysis and evaluation through extensive numerical analysis or further experimental study if necessary. The seismic analysis and design of 101-story Shanghai World Financial Center Tower is introduced as a typical engineering example where the PBSD approach is followed. The example demonstrates that the PBSD approach is an appropriate way to control efficiently the seismic damage on the structure and ensure the predictable and safe performance.

사고 영향 분석을 이용한 성능위주의 내화설계 (Performance Based Design of Passive Fire Protection Using Consequence Analysis)

  • 한동훈;이종호
    • 한국안전학회지
    • /
    • 제19권1호
    • /
    • pp.102-107
    • /
    • 2004
  • Performance based design is a recent evolutionary step in the process of designing fire protection systems. In essence, it is a logical design process resulting in a solution that achieves a specified performance. Sometimes the prescriptive solutions presented in various codes and standards are too expensive or inflexible. Often the solutions do not and enables optimization of a solution for cost and function. In this study, performance based design was carried out to determine the extent of passive fire protection for oil terminal facilities. The results of performance based design were compared with those of prescriptive code based design. Performance based design is not always more economic than prescriptive code based design but provides more reliable and effective design that is fit for the purpose.

반도체공장 Clean Room에 대한 화재요인 분석 및 성능위주 화재안전설계 (Fire Hazard Analysis and Performance Based Fire safety Design for the Clean Room in Semiconductor Factory)

  • 한수진;강경식
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2006년도 추계공동학술대회
    • /
    • pp.325-336
    • /
    • 2006
  • This research analyzes clean room major fire prevention standard of clean Room (FM, IRI, and NFPA Code), the structure of Performance-Based Fire Safety Design (PBD) applied the korean fire industry situation. Performance-Based Fire Safety can operate effectively the performance of fire protection equipment & building design, so the fitness of fire safety system can be embodied by operating this. moreover, cost to be consume fire safety of real building can reduce and Performance-Based Fire Safety is considered to important technique in fire protection field. A fire in a clean room may cause a serious loss by spreading smoke particles. We will be investigated by using a computational fluid dynamics, for loss prevention by smoke spreading from one fire area to another for clean room and compared the Performance-Based Fire Safety Design with the prescriptive code design. The methodology of fire safety performance-based fire safety design and guarantee of many kinds design skill of fire system and developing design procedure will be very serious one in order to improve efficiency of domestic system. Therefore, This research will be contributing to secure safety of clean room and to set up the performance-based fire safety design in Korea by regulation for the performance-based fire safety design effectively.

  • PDF

반도체공장 Clean Room에 대한 화재요인 분석 및 성능위주 화재안전설계(1) (Fire Hazard Analysis and Performance Based Fire safety Design for the Clean Room in Semiconductor factory(1))

  • 한수진;강경식
    • 대한안전경영과학회지
    • /
    • 제8권5호
    • /
    • pp.211-229
    • /
    • 2006
  • This research analyzes clean room major fire prevention standard of clean Room(FM, IRI, and NFPA Code), the structure of Performance-Based Fire Safety Design(PBD) applied the korean fire industry situation. Performance-Based Fire Safety can operate effectively the performance of fire protection equipment & building design, so the fitness of fire safety system can be embodied by operating this. moreover, cost to be consume fire safety of real building can reduce and Performance-Based Fire Safety is considered to important technique in fire protection field. A fire in a clean room may cause a serious loss by spreading smoke particles. We will be investigated by using a computational fluid dynamics, for loss prevention by smoke spreading from one fire area to another for clean room and compared the Performance-Based Fire Safety Design with the prescriptive code design. The methodology of fire safety performance-based fire safety design and guarantee of many kinds design skill of fire system and developing design procedure will be very serious one in order to improve efficiency of domestic system. Therefore, This research will be contributing to secure safety of clean room and to set up the performance-based fire safety design in Korea by regulation for the performance-based fire safety design effectively.

대향류형 냉각탑의 탈설계 성능해석 (Off-Design Performance Analysis of a Counterflow-Type Cooling Tower)

  • 신지영;손영석;한동원
    • 설비공학논문집
    • /
    • 제14권3호
    • /
    • pp.191-198
    • /
    • 2002
  • Cooling tower design procedure was set up using conventional Merkel theory, The design data could be different depending on the characteristic curve that the engineer chose. It reveals that the consistent and reasonable criteria are required based on the exact information of the cooling tower Performance. In this study, an off-design performance analysis program for a counterflow-type cooling tower was developed and verified by comparing with experimental data. Also, the off-design performance with various operating conditions was analyzed.

Overview of Performance-Based Seismic Design of Building Structures in China

  • Li, Guo-Qiang;Xu, Yan-Bin;Sun, Fei-Fei
    • 국제초고층학회논문집
    • /
    • 제1권3호
    • /
    • pp.169-179
    • /
    • 2012
  • The development history, the current situation and the future of the performance-based seismic design of building structures in China are presented in this paper. Firstly, the evolution of performance-based seismic design of building structures specified in the Chinese codes for seismic design of buildings of the edition 1974, 1978, 1989, 2001 and 2010 are introduced and compared. Secondly, in two parts, this paper details the provisions of performance-based seismic design in different Chinese codes. The first part is about the "Code for Seismic Design of Buildings" (GB50011) (edition 1989, 2001 and 2010) and "Technical Specification for Concrete Structures of Tall Building", which presents the concepts and methods of performance-based seismic design adopted in Chinese codes; The second part is about "Management Provisions for Seismic Design of Outof-codes High-rise Building Structures" and "Guidelines for Seismic Design of Out-of-codes High-rise Building Structures", which concludes the performance-based seismic design requirements for high-rise building structures over the relevant codes in China. Finally, according to those mentioned above, this paper pointed out the imperfections of current performance-based seismic design in China and proposed the possible direction for further improvement.

설계스펙트럼의 개정에 따른 철근콘크리트 보통모멘트골조의 내진성능수준 평가 (Performance-Based Evaluation of Seismic Design Proposals for RC Ordinary Moment Frames by Spectrum Revision)

  • 심정은;최인섭;김준희
    • 한국지진공학회논문집
    • /
    • 제26권5호
    • /
    • pp.211-217
    • /
    • 2022
  • New buildings have been designed using different seismic design standards that have been revised. However, the seismic performance of existing buildings is evaluated through the same performance evaluation guidelines. Existing buildings may not satisfy the performance targets suggested in the current guidelines, but there are practical limitations to discriminating the existing buildings with poor seismic performance through a full investigation. In this regard, to classify buildings with poor seismic performance according to the applied standard, this study aimed to evaluate performance-based investigation of the seismic design proposals of buildings with different design standards. The target buildings were set as RC ordinary moment frames for office occupancy. Changes in seismic design criteria by period were analyzed, and the design spectrum changes of reinforced concrete ordinary moment resisting frames were compared to analyze the seismic load acting on the building during design. The seismic design plan was derived through structural analysis of the target model, compared the member force and cross-sectional performance, and a preliminary evaluation of the seismic performance was performed to analyze the performance level through DCR. As a result of the seismic performance analysis through the derived design, the reinforced concrete ordinary moment frame design based on AIK 2000 has an insufficient seismic performance level, so buildings built before 2005 are likely to need seismic reinforcement.

직접변위기반 설계법에 의한 SRC 합성기둥의 내진성능평가 (Seismic Performance Evaluation of SRC Composite Column using Direct Displacement Based Design Method)

  • 정인규;박순응;김동혁
    • 한국공간구조학회논문집
    • /
    • 제12권3호
    • /
    • pp.63-70
    • /
    • 2012
  • 본 연구에서는 변위기반 성능설계 개념에 의해 기존 철근콘크리트 기둥과 콘크리트에 강재를 매입한 SRC 합성기둥에 대하여 최대 설계지진 가속도에 대한 내진성능개선의 성능설계을 비교하였다. SRC 합성기둥은 구조물의 강도를 증가시킬 뿐 아니라 연성도를 증가시키는 효과가 있다. SRC 합성기둥의 단면은 H형 강재와 원형의 중공 강관을 매입한 형태로 구성되어 있다. SRC 합성기둥에 대한 P-M상관도와 단면 공칭휨모멘트를 분석하고 이를 바탕으로 SRC 합성기둥에 대한 설계 변위 추정을 위해 변위기반 내진 설계 알고리즘을 제시하였다. 성능기반설계에 의한 성능개선설계를 위하여 목표성능변위 및 설계지진가속도 조건에 대해 직접변위 기반 설계방법 및 변위계수법에 의한 내진성능개선 설계 방법을 제시하였다. SRC 합성기둥은 기존 RC 기둥과 비교하여 성능개선 설계 결과 변위 연성비 및 변위성능에서 크게 개선된 성능설계 결과를 나타내었다.

Comparison of Database Models for Developing a Pavement Performance Analysis System

  • Choi Jae-ho
    • 한국건설관리학회논문집
    • /
    • 제5권4호
    • /
    • pp.79-86
    • /
    • 2004
  • One of the most difficult tasks in pavement management information systems is establishing the links between performance measures of a structure and the design and construction inputs. In-situ pavement performance can be considered a response variable to many project input variables, such as design, construction, and traffic loading effects. If we are to fully understand the component of pavement performance and specify the inputs through design and construction specifications to achieve that performance we must develop quantitative relationship between input and response variables through a scientific, fully integrated Pavement Performance Analysis System (PPAS). Hence, the objective of this study is to design a database model required for developing an effective database template that will allow analysis of pavement performance measures based on design and construction information linked by location. In order to select the most appropriate database model, a conceptual database model (Entity Relationship Model) and dimensional model, which is believed to be the most effective modeling technique for data warehouse project, are designed and compared. It is believed that other state highway agencies could adopt the proposed design strategy for implementing a PPAS at the discretion of the state highway agencies.

압축기 설계조건이 가스터빈 엔진의 탈설계점 성능에 미치는 영향 (The Effects of Compressor Design Conditions on the Off-Design Performance of a Gas Turbine Engine)

  • 강동진;정평석;안상규
    • 대한기계학회논문집
    • /
    • 제18권9호
    • /
    • pp.2413-2422
    • /
    • 1994
  • The effects of compressor design conditions on the off-design performance of a single-shaft gas turbine engine have been studied. Three different geometric design conditions are considered and three different values for the specific mass flow rate at the inlet to the compressor are assumed. For each of nine compressor design, the off-design performance of the gas turbine engine is predicted using the method previously proposed by present authors. Results show that the predicted off-design performances are quite different from each other even though they have the same performance at design point: it means that compressor design conditions should be determined in consideration of the off-design performance of the engine. The specific mass flow rate at the inlet to the compressor is also shown that it might be optimized with respect to the net power of the engine.