Development and Simulation Verification of Operation System for Mobile ESS Test Equipment (ESS 이동형 시험장비용 운영시스템의 개발과 모의검증)

  • Shin, Je-Seok;Han, Hyun-Gyu;Kim, Jin-Tae;Lee, Seung-Min;Park, Chan-Wook;Lim, Geon-Pyo
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.67 no.3
    • /
    • pp.168-174
    • /
    • 2018
  • The performance test for 376MW ESS for frequency regulation currently operating in 13 substations is conducted based on the test procedure in the first and second steps. In the first step, components of ESS is moved to the certification authority where the test equipment is located in order to be proceeded with the test. In the second step, the performance test is conducted manually for the ESS equipments installed on site using the movable measurement equipment, and thus it can only be performed on some limited test items and requires a lot of time and manpower. Therefore, mobile test equipment for ESS(MOTES) is being developed that can perform automatically more test items for ESS in the field using the MOTES, and reduce manpower and time. To do this, an algorithm and a prototype of the operating system(MOS) are also being developed that can control MOTES automatically. In this paper, a development of the MOS prototype is introduced and then a simulation is performed to verify the prototype and its algorithm before the field demonstration.

Performance Analysis and Evaluation of 3kW Grid-Connected PV Systems (3kW급 계통연계형 태양광발전시스템의 성능특성 평가분석)

  • So, Jung-Hun;Jung, Young-Seok;Yu, Gwon-Jong;Choi, Ju-Yeop;Choy, Ick
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.8
    • /
    • pp.509-516
    • /
    • 2004
  • The concerns of distributed generations including photovoltaic(PV) system have been increased around the world since PV system is becoming widespread as a clean and gentle energy source for earth. In the future high density grid-connected PV systems will be interconnected with distribution network. As a result, the stability and long-term reliability of PV systems have become more important issues in this area. Grid-connected PV systems have been installed and monitored at field demonstration test center(FDTC) and also data acquisition system(DAS) has been constructed for measuring and analyzing performance of PV system to observe the overall effect of environmental conditions on their operation characteristics. The performance of PV system has been evaluated and analyzed for component perspective (PV array and power conditioning system) and global perspective (system efficiency, capacity factor, and electrical power energy) by field test and loss factors of PV system.

Plan of Test-line Construction for Performance Evaluation of the KRTCS (무선통신기반 열차제어시스템 성능평가 시험선 구축 방안)

  • Yun, Hak-Sun;Kim, Dae-Won;Jang, Sa-Sul;Choi, Jin-Sig
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1041-1048
    • /
    • 2011
  • For "Standardization and Performance Evaluation of the Korea Radio Train Control System(KRTCS) for Urban railway" being driven as a national R&D project, this paper presents the requirements for the performance evaluation of the construction of the demonstration line for the driverless train control system based on radio train control for the urban railways system, which will be installed along the 11.7 km section between the Illo Station, Muan-gun, and Daebul Station(Daebul Line) in Yeongam-gun, Jeollanam-do.

  • PDF

Development, Demonstration and Validation of the Deep Space Orbit Determination Software Using Lunar Prospector Tracking Data

  • Lee, Eunji;Kim, Youngkwang;Kim, Minsik;Park, Sang-Young
    • Journal of Astronomy and Space Sciences
    • /
    • v.34 no.3
    • /
    • pp.213-223
    • /
    • 2017
  • The deep space orbit determination software (DSODS) is a part of a flight dynamic subsystem (FDS) for the Korean Pathfinder Lunar Orbiter (KPLO), a lunar exploration mission expected to launch after 2018. The DSODS consists of several sub modules, of which the orbit determination (OD) module employs a weighted least squares algorithm for estimating the parameters related to the motion and the tracking system of the spacecraft, and subroutines for performance improvement and detailed analysis of the orbit solution. In this research, DSODS is demonstrated and validated at lunar orbit at an altitude of 100 km using actual Lunar Prospector tracking data. A set of a priori states are generated, and the robustness of DSODS to the a priori error is confirmed by the NASA planetary data system (PDS) orbit solutions. Furthermore, the accuracy of the orbit solutions is determined by solution comparison and overlap analysis as about tens of meters. Through these analyses, the ability of the DSODS to provide proper orbit solutions for the KPLO are proved.

Effects of an Educational Method using the OSCE Module Development Activities for Nursing Students on the Clinical Competence of Medication (간호학생의 구조화된 객관적 임상수행펑가 (OSCE) 모듈 개발 활동이 투약간호술에 미치는 효과)

  • Kim, Hyun-Sook;Eom, Mi Ran
    • Perspectives in Nursing Science
    • /
    • v.9 no.2
    • /
    • pp.136-145
    • /
    • 2012
  • Purpose: The purpose of this study was to verify the educational effectiveness of the Objective structured clinical examination (OSCE) module development activities on nursing students in the areas of performance skill, knowledge, self-directed learning readiness, and problem solving ability for medication skill. Methods: This study was a nonequivalent control group non-synchronized post-test design. The subjects (N=47), who agreed to participate in this study, were assigned to either the experimental (n=24) or control group (n=23). The experimental group was trained with OSCE module development activities for four days. The control group was trained with a traditional demonstration and practice class for the same amount of time as the experimental group. Medication performance skill and knowledge tests and surveys were done to measure self-directed learning readiness, and learning satisfaction after the experimental treatments. Results: The experimental group which participated in the OSCE module development activities showed significantly higher performance skill, self-directed learning readiness, and problem solving ability for skin test and insulin medication than that of the control group of traditional education. Conclusion: It is recommended to use the OSCE module development activities for nursing students in nursing education-learning in order to improve nursing skills.

  • PDF

KOREN based Domestic and International Verification Test of Mass Abyss Storage (대용량 Abyss Storage의 KOREN 네트워크 기반 국내 및 해외 실증 테스트)

  • Cha, ByungRae;Cha, YoonSeok;Choi, MyeongSoo;Park, Sun;Kim, JongWon
    • Smart Media Journal
    • /
    • v.6 no.1
    • /
    • pp.9-15
    • /
    • 2017
  • The trends in ICT are concentrated in IoT, Bigdata, and Cloud Computing. These mega-trends do not operate independently, and mass storage technology is essential as large computing technology is needed in the background to support them. In order to evaluate the performance of high-capacity storage based on open source Ceph, we carry out the demonstration test of Abyss Storage with domestic and overseas sites using educational network KOREN. In addition, storage media and network bonding are tested to evaluate the performance of the storage itself. Although there is a substantial difference in aspect of the physical speed among storage medias, there is no significant performance difference in the storage media test performed. As a solution to this problem, we could get performance improvement through network acceleration. In addition, we conducted actual performance test of Abyss Storage internal and external network by connecting domestic and overseas sites using KOREN network.

Demonstration of Voltage Control of DC Distribution System Using Real-time DC Network Analysis Applications (실시간 DC 계통해석 응용프로그램을 이용한 DC 배전망 전압제어 실증 연구)

  • Kim, Hong-joo;Cho, Young-pyo;Cho, Jin-tae;Kim, Ju-yong
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.5 no.4
    • /
    • pp.275-286
    • /
    • 2019
  • This paper presents real-time Direct Current (DC) network analysis applications for operation of DC distribution system or DC microgrid. These applications are installed on central Energy Management System (EMS) and provide solutions of DC network operation. To analysis DC distribution network, this paper proposes composition and sequence of applications. Algorithm of applications is presented in this paper. Demonstration tests are performed on DC distribution site in Gochang Power Testing Center of Korea Electric Power Corporation (KEPCO). To verify the performance, developed DC applications installed on EMS. Scenarios for demonstration test of voltage control are presented. Finally, measured data, application output data and simulation data (by PSCAD/EMTDC) are compared and analyze accuracy of applications.

Performance of High Temperature Filter System for Radioactive Waste Vitrification Plant (방사성폐기물 유리화 플랜트 고온여과시스템의 성능 특성)

  • Seung-Chul, Park;Tae-Won, Hwang;Sang-Woon, Shin;Jong-Hyun, Ha;Hey-Suk, Kim;So-Jin, Park
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.2 no.3
    • /
    • pp.201-209
    • /
    • 2004
  • Important operation parameters and performance of a high temperature ceramic candle filter system were evaluated through a series of demonstration tests at a pilot-scale vitrification plant. At the initial period of each test, due to the growth of dust cake on the surface of ceramic candles, the pressure drop across the filter media increased sharply. After that it became stable to a certain range and varied continuously proportion to the face velocity of off-gas. On the contrary, at the initial period of each test, the permeability of filter element decreased rapidly and then it became stable. Back flushing of the filter system was effective under the back flushing air pressure range of 3∼5 bar. Based on the dust concentrations measured by iso-kinetic dust sampling at the inlet and outlet point of HTF, the dust collection efficiency of HTF evaluated. The result met the designed performance value of 99.9%. During the demonstration tests including a hundred hour long test, no specific failure or problem affecting the performance of HTF system were observed.

  • PDF

Evaluation of thermal-hydro-mechanical behavior of bentonite buffer under heating-hydration condition at disposal hole (처분공 가열-수화 조건에서 벤토나이트 완충재의 열-수리-역학적 거동 특성 평가)

  • Yohan Cha;Changsoo Lee;Jin-Seop Kim;Minhyeong Lee
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.25 no.2
    • /
    • pp.175-186
    • /
    • 2023
  • The buffer materials in disposal hole are exposed to the decay heat from spent nuclear fuels and groundwater inflow through adjacent rockmass. Since understanding of thermal-hydro-mechanical-chemical (T-H-M-C) interaction in buffer material is crucial for predicting their long-term performance and safety of disposal repository, it is necessary to investigate the heating-hydration characteristics and consequent T-H-M-C behavior of the buffer materials under disposal conditions considering geochemical factors. In response, the Korea Atomic Energy Research Institute developed a laboratory-scale 'Lab.THMC' experiment system, which characterizes the T-H-M behavior of buffer materials under different geochemical conditions by analyzing heating-hydration process and stress changes. This technical report introduces the detail design of the Lab.THMC system, summarizes preliminary experimental results, and outlines future research plans.

Study on Moye's Method for Analysis of Constant-Head Tests Conducted in Crystalline Rock (결정질 암반에서 Moye 방법을 이용한 정압시험의 해석에 대한 고찰)

  • Kyung-Woo Park;Byeong-Hak Park;Sung-Hoon Ji;Kang-Kun Lee
    • The Journal of Engineering Geology
    • /
    • v.33 no.4
    • /
    • pp.519-530
    • /
    • 2023
  • Moye's analytical solution was examined as a method for constant-head tests under steady-state conditions, and results were compared with transient-state analyses in in situ hydraulic tests. The sensitivity of hydraulic conductivities calculated using Moye's method increased with the length of the test section, which should be as large as possible under test conditions. Particularly in low-permeability media with less than 10-8 m/sec of hydraulic conductivity, hydraulic conductivity is lower than that under transient-state conditions and can be recalculated by adjusting the boundary between radial and spherical flow assumed in Moye's equation. Constant-head tests performed in the research borehole at the KAERI Underground Research Tunnel (KURT) indicated that transmissivities derived from the constant-head withdrawal test under transient-state conditions in low-permeability media were higher than those derived from steady-state tests, likely because the groundwater flow boundary was smaller than the "half of the test-section length"assumed by Moye's equation. When interpreting constant-head test results for crystalline rock, the hydrogeological properties of the medium may be better understood by considering assumed conditions accompanying analysis of the steady-state condition and comparing them with results for the transient-state analysis, rather than simply assuming properties based on steady-state analyses.