• Title/Summary/Keyword: Performance Demonstration

Search Result 400, Processing Time 0.028 seconds

Development of Ultrasonic Testing System for Piping Welds (배관 용접부 초음파검사 시스템 개발)

  • Choi, Sung-Nam;Kim, Hyung-Nam;Yoo, Hyun-Ju;Cho, Hyun-Jun;Hwang, Won-Gul
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.4
    • /
    • pp.331-338
    • /
    • 2008
  • Ultrasonic testing for welds is widely used to ensure the integrity of facilities in NPPs. Automated ultrasonic testing(AUT) is more consistent than the manual ultrasonic testing(MUT). It can scan welded parts, examines the scanned images, and saves the results as data files. AUT in NPPs is making use of commercial systems, and there has been some difficulties in calibration of the system. An AUT system is developed. It comprises of pulser/receiver, scanner and a control program(SonicWizard). The performance demonstration for piping welds in NPPs and the piping wall thickness measurement on site were conducted to verify this system. The test results of the ultrasonic testing system developed is satisfactory and effective.

Effect Analysis for Frequency Recovery of 524 MW Energy Storage System for Frequency Regulation by Simulator

  • Lim, Geon-Pyo;Choi, Yo-Han;Park, Chan-Wook;Kim, Soo-Yeol;Chang, Byung-Hoon;Labios, Remund
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.2
    • /
    • pp.227-232
    • /
    • 2016
  • To test the effectiveness of using an energy storage system for frequency regulation, the Energy New Business Laboratory at KEPCO Research Institute installed a 4 MW energy storage system (ESS) demonstration facility at the Jocheon Substation on Jeju Island. And after the successful completion of demonstration operations, a total of 52 MW ESS for frequency regulation was installed in Seo-Anseong (28 MW, governor-free control) and in Shin-Yongin (24 MW, automatic generation control). The control system used in these two sites was based on the control system developed for the 4 MW ESS demonstration facility. KEPCO recently finished the construction of 184 MW ESS for frequency regulation in 8 locations, (e.g. Shin-Gimjae substation, Shin-Gaeryong substation, etc.) and they are currently being tested for automatic operation. KEPCO plans to construct additional ESS facilities (up to a total of about 500 MW for frequency regulation by 2017), thus, various operational tests would first have to be conducted. The high-speed characteristic of ESS can negatively impact the power system in case the 500 MW ESS is not properly operated. At this stage we need to verify how effectively the 500 MW ESS can regulate frequency. In this paper, the effect of using ESS for frequency regulation on the power system of Korea was studied. Simulations were conducted to determine the effect of using a 524 MW ESS for frequency regulation. Models of the power grid and the ESS were developed to verify the performance of the operation system and its control system. When a high capacity power plant is tripped, a 24 MW ESS supplies power automatically and 4 units of 125MW ESS supply power manually. This study only focuses on transient state analysis. It was verified that 500 MW ESS can regulate system frequency faster and more effectively than conventional power plants. Also, it was verified that time-delayed high speed operations of multiple ESS facilities do not negatively impact power system operations. It is recommended that further testing be conducted for a fleet of multiple ESSs with different capacities distributed over multiple substations (e.g. 16, 24, 28, and 48 MW ESS distributed across 20 substations) because each ESS measures frequency individually. The operation of one ESS facility will differ from the other ESSs within the fleet, and may negatively impact the performance of the others. The following are also recommended: (a) studies wherein all ESSs should be operated in automatic mode; (b) studies on the improvement of individual ESS control; and (c) studies on the reapportionment of all ESS energies within the fleet.

Development Status of Technology Demonstration Model for Staged Combustion Cycle Engine (다단연소사이클 엔진 기술검증시제 개발 현황)

  • Kim, Chaehyoung;Lee, Jungho;Woo, Seongphil;So, Younseok;Yi, SeungJae;Lee, Kwang-Jin;Cho, Namkyung;Han, Yeoungmin;Kim, Jin-han
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.23 no.4
    • /
    • pp.104-111
    • /
    • 2019
  • Staged combustion cycle engines exhibit higher combustion performance compared with open cycle engines with a gas generator. An advanced research of the staged combustion cycle engine is going on for the next program following the KSLV-II program. Various experiments have been carried out for the technology demonstration model, TDM0A and TDM0B. The experiments on the combustion performance are aimed to understand the engine start condition and combustion characteristics. They also aim to develop the oxidizer-rich pre-burner and the combustor of the staged combustion cycle engine. The engine-shaped model, TDM1A is fabricated based on the experimental data. The combustion experiment of the TDM1A shows that the combustion pressure of the combustor is approximately 91 bar and the turbine rotation is approximately 28,00 rpm. The result is stable and satisfies the development requirements. The present paper reports on the development process and characteristics of engine models from TDM0A to TDM1A.

A Review of the Influence of Sulfate and Sulfide on the Deep Geological Disposal of High-level Radioactive Waste (고준위방사성폐기물 심층처분에 미치는 황산염과 황화물의 영향에 대한 고찰)

  • Jin-Seok Kim;Seung Yeop Lee;Sang-Ho Lee;Jang-Soon Kwon
    • Economic and Environmental Geology
    • /
    • v.56 no.4
    • /
    • pp.421-433
    • /
    • 2023
  • The final disposal of spent nuclear fuel(SNF) from nuclear power plants takes place in a deep geological repository. The metal canister encasing the SNF is made of cast iron and copper, and is engineered to effectively isolate radioactive isotopes for a long period of time. The SNF is further shielded by a multi-barrier disposal system comprising both engineering and natural barriers. The deep disposal environment gradually changes to an anaerobic reducing environment. In this environment, sulfide is one of the most probable substances to induce corrosion of copper canister. Stress-corrosion cracking(SCC) triggered by sulfide can carry substantial implications for the integrity of the copper canister, potentially posing a significant threat to the long-term safety of the deep disposal repository. Sulfate can exist in various forms within the deep disposal environment or be introduced from the geosphere. Sulfate has the potential to be transformed into sulfide by sulfate-reducing bacteria(SRB), and this converted sulfide can contribute to the corrosion of the copper canister. Bentonite, which is considered as a potential material for buffering and backfilling, contains oxidized sulfate minerals such as gypsum(CaSO4). If there is sufficient space for microorganisms to thrive in the deep disposal environment and if electron donors such as organic carbon are adequately supplied, sulfate can be converted to sulfide through microbial activity. However, the majority of the sulfides generated in the deep disposal system or introduced from the geosphere will be intercepted by the buffer, with only a small amount reaching the metal canister. Pyrite, one of the potential sulfide minerals present in the deep disposal environment, can generate sulfates during the dissolution process, thereby contributing to the corrosion of the copper canister. However, the quantity of oxidation byproducts from pyrite is anticipated to be minimal due to its extremely low solubility. Moreover, the migration of these oxidized byproducts to the metal canister will be restricted by the low hydraulic conductivity of saturated bentonite. We have comprehensively analyzed and summarized key research cases related to the presence of sulfates, reduction processes, and the formation and behavior characteristics of sulfides and pyrite in the deep disposal environment. Our objective was to gain an understanding of the impact of sulfates and sulfides on the long-term safety of high-level radioactive waste disposal repository.

Balanced Performance Measurement System for Strategic Learning (전략적 학습의 촉진을 위한.균형 성과측정시스템의 개발)

  • Min, Jae H;Lee, Young-Chan;Ha, Chang-Hoon
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.27 no.3
    • /
    • pp.93-114
    • /
    • 2002
  • This paper suggests a dynamic balanced scorecard (DBSC) model employing the concept of system dynamics (SD), which could overcome the limitations inherent in the conventional balanced scorecard (BSC) and facilitate strategic learning process in organizations. The BSC has been a successful framework for measuring an organization's performance in various Perspectives through translating an organization's vision and strategy into an interrelated set of key performance indicators and specific actions. The BSC, while having significant strengths over traditional performance measurement methods, however, has its own limitations, due to its static nature, such as overlooking two-way causation between performance Indicators and neglecting the impact of delayed feedback flowing from the adoption of new strategies or policy changes. To overcome these limitations, we employs SD, a methodology for understanding complex systems where dynamic feedback among the interrelated system components significantly impact on the system outcomes. The SD simulation model in the form of DBSC we suggest in this paper would serve as a useful strategic learning tool for facilitating an organization's communication process through various scenario analyses as well as predicting the dynamic behavior pattern of their key performance measures over a future time frame. For the demonstration purpose, we apply the DBSC model to Korea Coal Corporation (KoCoal ) BSC case.

Study on Development of Performance Evaluation Guidelines for Leak Test Smart Gas Meter (누출점검용 스마트가스미터의 성능시험 가이드라인 개발 연구)

  • Kim, Minjun;Oh, Jeong Seok
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.5
    • /
    • pp.8-14
    • /
    • 2019
  • Although the rate of city gas supply in South Korea has grown significantly, the fields related to gas meters have not yet escaped from the initial method of service (e.g. measurement, safety checks, billing, etc). As smart gas meters are actively developed and researched, the introduction of smart gas meters requires rational performance evaluation methods and standards to verify reliability and safety. The purpose of this paper is to make a prototype of the performance evaluation to test the performance of the smart gas meter and to derive the performance evaluation method by conducting the demonstration operation so that the smart gas meter can be smoothly distributed in South Korea.

Research of Performance for the Propulsion System of Maglev Vehicle (도시형 자기부상열차 추진특성에 관한 성능연구)

  • Kim, Bong-Seup;Koh, Joon-Kyun;Park, Do-Young;Kang, Byung-Gwan
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.2342-2347
    • /
    • 2011
  • This paper introduces the performance test of the prototype vehicle, which will be in operation for Urban Maglev Program. While common trains with steel wheels use rotary induction motors for propulsion, maglev trains gain thrust force from linear induction motors maintaining the constant airgap with levitation electromagnets. Therefore, not only the behavior of the linear induction motor should be well understood, but also the way of propulsion that minimizes its effect on the levitation system should be took into account. Performance test procedures of maglev trains are proposed and carried out, and the characteristics of acceleration and deceleration are verified to agree with the design criteria. Tests are mainly performed on the linear section of the test line, and the driving characteristics on the section with a 6‰ incline are examined additionally. As a result, the performance of the prototype vehicle in the reverse operation can satisfy the requirement about the acceleration and deceleration, 4.0$m/s^2$. And, the design modifications of the commercial vehicle and the performance specifications required on the demonstration line are investigated.

  • PDF

Development of Evaluation Methodology on the Performance of BTL Sewer Rehabilitation Projects (하수관거정비 BTL사업의 효과분석 및 방안 수립 연구)

  • Song, Ho-Myeon;Cho, Jeong-Il;Ahn, Choong-Hee
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.6
    • /
    • pp.743-751
    • /
    • 2010
  • It requires an interim performance assessment for BTL business of the sewerage rehabilitation which continues from 2005 till now. Means, It is necessary to make an interim performance assessment and an analysis of an business effect of the sewerage rehabilitation BTL projects which still continues, and we presented an improvement method of the new sewerage rehabilitation project in future. This paper has conducted an analysis of the business effect for 3 local government BTL projects which are completed and under operation as of now in Jincheon-Gun, Cheongju-Si and Gangjin-Gun. As a method of business effect analysis, we conducted a business effect of the 3 places using the index set which we previously set for the business effect analysis. The index set in this research was sectionalized to an improvement effect of operating wastewater treatment plant, an benefit effect of the direct cost, an benefit effect of the indirect cost and an environment friendly effect. We, in this paper, conducted an business effect analysis for 3 sewerage rehabilitation BTL projects which are completed or under operation recently as a demonstration, however we judge that an business effect analysis shall be conducted in a stage that a significant time for operation has passed since the completion of the construction in order to induce an actual business effect of the sewerage rehabilitation BTL project.

Monitoring and Analysis of 3kW Grid-Connected PV System for Performance Evaluation

  • So Jung-Hun;Jung Young-Seok;Yu Gwon-Jong;Choi Ju-Yeop;Choi Jae-Ho
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.5B no.1
    • /
    • pp.57-62
    • /
    • 2005
  • Grid-connected photovoltaic (PV) systems were installed and monitored at the field demonstration test center (FDTC) in Korea in October 2002. Before long-term field testing of installed PV systems, the performances of PV components were evaluated and compared through short-term performance tests of each of the PV system components such as power conditioning system and PV module under standard test conditions. A data acquisition system has been constructed for measuring and analyzing the performance of PV systems to observe the overall effect of environmental conditions on their operation characteristics. Performances of PV systems have been evaluated and analyzed not only for component perspective (PV array, power conditioning unit) but also for global perspective (system efficiency, capacity factor, electrical power energy) by review of the field test and loss factors of the systems. These results indicate that it is highly imperative to develop an optimum design technology of grid connected PV systems. The objective of this paper is not only to evaluate and analyze the performance of domestic PV systems application through long-term field testing at FDTC but also to develop evaluation, analysis and optimum technology for long-term stability and reliability of grid-connected PV systems in Korea.

A Study on Performance Analysis of 3kW Grid-Connected PV Systems (3kW급 계통연계형 태양광발전시스템의 성능특성 비교분석에 관한 연구)

  • So, Jung-Hun;Choi, Ju-Yeop;Yu, Gwon-Jong;Jung, Young-Seok;Choi, Jae-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.24 no.2
    • /
    • pp.9-15
    • /
    • 2004
  • 3kW grid connected PV(photovoltaic) systems have been constructed for evaluating and analyzing performance of PV system at FDTC(field demonstration test center) in Korea, PV systems installed in FDTC have been operating and monitored since November 2002. As climatic and irradiation conditions have been varied through long-term field test, data acquisition system has been constructed for measuring performance of PV system to observe the overall effect of environmental conditions on their operation characteristics. The performance of PV systems has been evaluated and analyzed for component perspective(PV array and power conditioning system) and global perspective(system efficiency, capacity factor, and electrical power energy) by field test. By the results, it is very important to develop optimal design technology of grid connected PV system.