• Title/Summary/Keyword: Performance Control

Search Result 25,332, Processing Time 0.061 seconds

Test on the Security and Performance on the Basis of the Access Control Policy Implemented by Secure OS (안전한 운영체제 접근제어 정책에 대한 보안성 및 성능 시험)

  • Kim, Jeong-Nyeo;Sohn, Sung-Won;Lee, Chelo-Hoon
    • The KIPS Transactions:PartD
    • /
    • v.10D no.5
    • /
    • pp.773-780
    • /
    • 2003
  • SecuROS(Secure & Reliable Operating System) prevents and blocks possible system cracking by implementing additional security functions in FreeBSD 4.3 operating system (OS) kernel, including access control, user authentication, audit trail, encryption file system and trusted channel. This paper describes access control technique, which is one of core technologies of SecuROS, introduces the implementations of DAC, MAC and RBAC, all of which are corresponding access control policies, and show security and results of performance measurement on the basis of application of access control policies. Finally, security and performance between conventional OS environment and environment adopting access control policy is described.

ExperimPerformance Evaluation of Modified Sliding Mode Control Algorithm for Nonlinear Structures (비선형 구조물에 대한 수정 슬라이딩모드 제어알고리즘 성능 평가)

  • Lee, Sang-Hyun
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.20 no.2
    • /
    • pp.147-155
    • /
    • 2007
  • In this study, the performance of the modified sliding mode control proposed in the previous study is evaluated for seismic response control of nonlinear hysteretic structures. Modified sliding mode control(MSMC) utilizes the target derivative of Lyapunov function in order to calculate control force, and its performance was evaluated only lot linear structures in the previous study. However, considering that most structures subject to strong earthquake show nonlinear hysteretic behivior, the results from the previous study have limitations in practical application. The results from numerical analyses of single degree of freedom systems and base isolated system, which were described using Bouc-Wen model, indicate that the proposed MSMC algorithm shows better control performance than the existing sliding mode controller.

Performance Evaluation of Decentralized Control Algorithm of a Full-scale 5-story Structure Installed with Semi-active MR Damper Excited by Seismic Load (준능동 MR감쇠기가 설치된 실물크기 구조물의 분산제어 알고리즘 성능평가)

  • Youn, Kyung-Jo;Park, Eun-Churn;Lee, Heon-Jae;Moon, Seok-Jun;Min, Kyung-Won;Jung, Hyung-Jo;Lee, Sang-Hyun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.2
    • /
    • pp.255-262
    • /
    • 2008
  • In this study, seismic response control performance of decentralized response-dependent MR damper which generates the control force using only the response of damper-installed floor, was experimentally investigated through the tests of a full-scale structure installed with large MR dampers. The performance of the decentralized control algorithm was compared to those of the centralized ones such as Lyapunov, modulated homogeneous friction, and clipped-optimal control. Hybrid mass damper were controlled to induce seismic response of the full-scale structure under El Centro earthquake. Experimental results indicated that the proposed decentralized MR damper provided superior or equivalent performance to centralized one in spite of using damper-installed floor response for calculating input voltage to MR damper.

A Study on the Geothermal Heat Pump System Performance Analysis according to Water Flow Rate Control of the Geothermal Water Circulation Pump (지열순환펌프 유량변화에 따른 지열히트펌프시스템의 에너지 성능 평가)

  • Jung, Young-Ju;Jo, Jae-Hun;Kim, Yong-Shik;Cho, Young-Hum
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.6
    • /
    • pp.103-109
    • /
    • 2014
  • It is important to control the amount of supply water flow rate at all kinds of HVAC systems in order to maintain IAQ and energy efficiency. The most of buildings installed geothermal heat pumps is using fixed water flow rate in spite of the excellent performance of geothermal heat pumps. Especially when the air-conditioning load is low, the flow rate control may be possible to save energy to operate. However, it is effective to apply the variable flow control system in order to reduce energy consumption. Therefore, the purpose of this study, change a water flow rate and improve the whole performance of the geothermal heat pump. Geothermal heat pump system is modeled after the selection of the applied building, by setting the flow rate control to be analyzed through a simulation of performance evaluation. Building energy saving according to the flow rate of the ground circulating water analyze quantitatively and to investigate the importance of the flow control.

A High-Performance Speed Sensorless Control System for Induction Motor with Direct Torque Control (직접 토크제어에 의한 속도검출기 없는 유도전동기의 고성능 제어시스템)

  • Kim, Min-Huei;Kim, Nam-Hun;Baik, Won-Sik
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.51 no.1
    • /
    • pp.18-27
    • /
    • 2002
  • This paper presents an implementation of digital high-performance speed sensorless control system of an induction motor drives with Direct Torque Control(DTC). The system consists of closed loop stator flux and torque observer, speed and torque estimators, two hysteresis controllers, an optimal switching look-up table, IGBT voltage source inverter, and TMS320C31 DSP controller board. The stator flux observer is based on the combined current and voltage model with stator flux feedback adaptive control for wide speed range. The speed estimator is using the model reference adaptive system(MRAS) with rotor flux linkages for speed turning signal estimation. In order to prove the suggested speed sensorless control algorithm, and to obtain a high-dynamic robust adaptive performance, we have some simulations and actual experiments at low(20rpm) and high(1000rpm) speed areas. The developed speed sensorless system are shown a good speed control response characteristic, and high performance features using 2.2[kW] general purposed induction motor.

Dynamic Stall Control with Droop Leading Edge and Gurney Flap (앞전 Droop과 Gurney 플랩을 이용한 동적 실속 제어)

  • Lee, Bo-Sung;Yee, Kwan-Jung;Joo, Wan-Don;Lee, Dong-Ho
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.32 no.5
    • /
    • pp.10-17
    • /
    • 2004
  • To achieve the advanced forward flight performance of helicopter, the passive control methods for enhancement of the dynamic stall characteristics of rotor blades are studied. To enhance the dynamic stall characteristics of the rotor blades, it is essential to improve the lift performance and the pitching moment performance simultaneously with the control of the separation on the rotor blades. For this point of view, both the fixed droop leading edge and the Gurney flap which are simply realized are used for control of the dynamic stall in severe dynamic stall conditions. From this study, the combination of both passive control methods showed dramatic enhancement of lift and pitching moment performance in dynamic stall than previous research results.

OPTIMIZATION OF THE PARAMETERS OF FEEDWATER CONTROL SYSTEM FOR OPR1000 NUCLEAR POWER PLANTS

  • Kim, Ung-Soo;Song, In-Ho;Sohn, Jong-Joo;Kim, Eun-Kee
    • Nuclear Engineering and Technology
    • /
    • v.42 no.4
    • /
    • pp.460-467
    • /
    • 2010
  • In this study, the parameters of the feedwater control system (FWCS) of the OPR1000 type nuclear power plant (NPP) are optimized by response surface methodology (RSM) in order to acquire better level control performance from the FWCS. The objective of the optimization is to minimize the steam generator (SG) water level deviation from the reference level during transients. The objective functions for this optimization are relationships between the SG level deviation and the parameters of the FWCS. However, in this case of FWCS parameter optimization, the objective functions are not available in the form of analytic equations and the responses (the SG level at plant transients) to inputs (FWCS parameters) can be evaluated by computer simulations only. Classical optimization methods cannot be used because the objective function value cannot be calculated directely. Therefore, the simulation optimization methodology is used and the RSM is adopted as the simulation optimization algorithm. Objective functions are evaluated with several typical transients in NPPs using a system simulation computer code that has been utilized for the system performance analysis of actual NPPs. The results show that the optimized parameters have better SG level control performance. The degree of the SG level deviation from the reference level during transients is minimized and consequently the control performance of the FWCS is remarkably improved.

Design of digital nuclear power small reactor once-through steam generator control system

  • Qian, Hong;Zou, Mingyao
    • Nuclear Engineering and Technology
    • /
    • v.54 no.7
    • /
    • pp.2435-2443
    • /
    • 2022
  • The once-through steam generator used in the small modular reactor needs to consider the stability of the outlet steam pressure and steam superheat of the secondary circuit to achieve better operating efficiency. For this reason, this paper designs a controllable operation scheme for the steam pressure and superheat of the small reactor once-through steam generator. On this basis, designs a variable universe fuzzy controller, first, design the fuzzy control rules to make the controller adjust the PI controller parameters according to the change of the error; secondly, use the domain adjustment factor to further subdivide the input and output domain of the fuzzy controller according to the change of the error, to improve the system control performance. The simulation results show that the operation scheme proposed in this paper have better system performance than the original scheme of the small reactor system, and controller proposed in this paper have better control performance than traditional PI controller and fuzzy PI controller, what's more, the designed control system also showed better anti-disturbance performance in lifting experiment between 100% and 80% working conditions. Finally, the experimental platform formed by connecting the digital small reactor with Matlab/Simulink through OPC(OLE for Process Control) communication technology also verified the feasibility of the proposed scheme.

Infection Control Analysis Research in Angiography Room (혈관조영검사실 감염관리 분석 연구)

  • Kim, Kyung-Wan;Im, In-Chul
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.2
    • /
    • pp.77-85
    • /
    • 2022
  • The purpose of this study was to investigate the status of infection control of angiography room workers through a survey, and to find out their awareness and performance. A survey was conducted from January 3 to February 28, 2022 on 126 workers working in angiography room of 10 hospitals at or above general hospital level located in Busan City. The questionnaire consists of 10 general characteristics of the subject and 56 items in total, divided into 4 main items of infection control in an angiography room: infection control system in a medical institution, personal hygiene, angiography room environment, and angiography room equipment. was measured on a Likert 5-point scale. Data analysis was performed statistically using SPSS for WindowTM release 25.0. t-test and one-way ANOVA were used to analyze the awareness and performance of each domain according to general characteristics, and Pearson correlation analysis was performed for the relationship between variables. As a result, the awareness level was higher than the performance level in all areas, indicating that the performance level was lower than the awareness level. In addition, awareness and performance showed a positive correlation, suggesting that the degree of awareness of workers is an important variable in infection control that has a significant effect on performance. Therefore, for effective and systematic infection control, workers in angiography room must improve the performance of infection control. In order to do that, infection control education is needed, and it is judged that infection control guidelines for angiography room should be systematized in the future.

A Comparison of the performance of mean, median, and precedence control charts for nonnormal data

  • Kim, Jung-Hee;Lee, Sung-Im;Park, Heon-Jin;Lee, Jae-Cheol;Jang, Young-Chul
    • Proceedings of the Korean Statistical Society Conference
    • /
    • 2005.05a
    • /
    • pp.197-201
    • /
    • 2005
  • In this article, we will compare the performance of the mean control chart, the median control chart, the transformed mean control chart, the transformed median control chart, and the precedence control chart by simulation study. For control charts with transformed data, Yeo-Johnson transformation is used. Under the in-control condition, ARL's in all control charts coincide with the designed ARL in the normal distribution, but in the other distributions, only the precedence control chart provides the in-control ARL as designed. Under the out-of-control condition, the mean control chart is preferred in the normal distribution and the median control chart is preferred in the heavy-tailed distribution and the precedence control chart outperforms in the short-tailed distribution.

  • PDF