• Title/Summary/Keyword: Performance Control

Search Result 25,332, Processing Time 0.052 seconds

Speed characteristic comparison of PI controller and SLMC in SRM drives (SRM 드라이브에서 PI 제어기와 SLMC의 속도 특성 비교)

  • Kim Jin-young;Choi Jae-dong;Ahn Jae-Hwang;Oh Seung-Up;Ju Hyung-Jun;Seung Se-jin
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.34-37
    • /
    • 2001
  • In this paper the comparison of conventional PI control and nonlinear sliding mode control is presented for Switched Reluctance Motor(SRM). SRM drives require a nonlinear controller for high dynamic Performance but the high nonlinearity makes a poor performance in conventional PI control. However SRMs with sliding mode control achieve a robust performance for speed control. In this paper nonlinear sliding mode controller is suggested for high performance speed. State equation and modeling are proposed. And we present the speed comparison of PI control and SLMC.

  • PDF

Performance Improvement of BLDC Motor Speed Control Using Hybrid PWM Method (하이브리드 PWM 방식을 이용한 브러시리스 직류 전동기의 속도 제어 성능 향상)

  • Lee, Dong-Hoon;Kim, Il-Hwan;Nam, Bu-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2004.05a
    • /
    • pp.19-21
    • /
    • 2004
  • This paper considers pulse width modulation (PWM) methods which are used in 3-phase brushless DC motor controller. Due to many disadvantages of bipolar PWM method, unipolar PWM method is mostly used in industrial field. In constant speed control application, the unipolar PWM method shows a good performance of speed control. But in the wide range of speed control application, it shows a poor performance especially when deceleration is needed. So we propose hybrid PWM method that utilizes two PWM methods according to the sign of speed controller output. The simulation and experimental result shows that the proposed method improves a speed control performance of the brushless DC motor which is applied to industrial sewing machines.

  • PDF

Performance Comparison of Different Solar Array Simulator Control by Ellipse Approximation (태양광패널 모사장치의 제어방식에 따른 소신호 특성 비교 분석)

  • Wellawatta, Thusitha;Seo, Young-Tae;Choi, Sung-Jin
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.1
    • /
    • pp.16-24
    • /
    • 2021
  • Solar array simulator (SAS) is essential equipment in testing and evaluating the power processing performance of a power conditioning system. However, the nonlinearity in the current(I)-voltage(V) characteristic makes the control loop design of SAS a challenging task. Conventionally, only the inner loop is usually considered in the control design approach. However, this study proves that the reference generation loop also interacts with the inner loop and plays a key role in the overall performance of the SAS. In this paper, the performance of voltage-mode control and impedance control, which are two of the most popular architectures for the SAS system, are reviewed and compared by multi-loop analysis.

Implementation of Ethernet-Based High-Speed Data Communication for Multi-core DSP (멀티 코어 DSP를 위한 이더넷 기반 고속 데이터 통신 구현)

  • Nguyen, Dung Huy;Choi, Joon-Young
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.17 no.3
    • /
    • pp.185-190
    • /
    • 2022
  • We propose a high speed data communication method for motor drive systems with fast control cycle in order to collect state variables of motor control without degrading control performance. Ethernet is chosen for communication device, and multi-core DSP architecture is exploited for communication processing load distribution. The communication program including network protocol stack and motor control program are assigned to two separate cores, and data between two cores are exchanged using interrupt-based inter-process communication mechanism, which enables to achieve a high-speed communication performance without degrading the motor control performance. The performance of developed communication method is demonstrated by real experiments using TCP, UDP and Raw Socket protocols in an experimental setup consisting of TI's TMS320F28388D motor control card and MS Windows PC.

Emergency Medical Technology Students' Awareness and Performance of Standard Precautions in Hospital Infection Control (응급구조과 학생의 병원감염 표준주의에 대한 인지도와 수행도)

  • Choi, Sung-Soo;Yun, Seong-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.5
    • /
    • pp.2262-2270
    • /
    • 2013
  • This study was to provide the basic data to raise the efficient practices that can reduce the Infection Prevention and Exposure by understanding the awareness, Performance degree of the Administrative Standard Guideline of Nosocomial Infection Control for Emergency Medical Technician students who are exposed to hospital infections while conducting clinical practice. After the study, the performance degree was lower than the awareness of the Performance degree of the Administrative Standard Guideline of Nosocomial Infection Control. And awareness and performance degree are have significant positive correlation, significant differences statistically(r=0.325, p=0.000). In the future, to improve the Performance degree of Nosocomial Infection Control for Emergency Medical Technician students, the continuing education programs and the curriculums should be performed in the practice agencies.

Seismic Performance Assessment of High-Rise Building installed with Multiple Active Tuned Mass Dampers (다중 능동형 동조질량감쇠기가 설치된 고층빌딩의 내진성능 평가)

  • Park, Kwan-Soon;Ok, Seung-Yong
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.6
    • /
    • pp.89-97
    • /
    • 2017
  • The tuned mass damper (TMD) system was first proposed as an efficient vibration control method for high-rise buildings, and multiple TMD (MTMD) system was then proposed for the purpose of improving the robust performance. Thereafter, the active TMD (ATMD) is proposed to improve the vibration control performance over the TMD and MTMD systems. However, this system may experience an system-instability problem in case of the actuator malfunction. In order to overcome such limitations of actuator malfunction causing the instability of the structural system, in this study, we investigate the feasibility of the multiple ATMD (MATMD) system that facilitates both advantages of the MTMD and ATMD. Numerical example demonstrates that, when the proposed system is designed to have the same capacity as the ATMD, it shows a similar control performance to the ATMD, but also has very good adaptive control performance against the emergency situations such as actuator failures.

Development of Performance Evaluation Metrics of Concurrency Control in Object-Oriented Database Systems

  • Jun, Woochun;Hong, Suk-Ki
    • Journal of Internet Computing and Services
    • /
    • v.19 no.5
    • /
    • pp.107-113
    • /
    • 2018
  • Object-oriented databases (OODBs) canbe used for many non-traditional database application areas such as computer-aided design, etc. Usually those application areas require advanced modeling power for expressing complicated relationships among data sets. OODBs have more distinguished features than the traditional relational database systems. One of the distinguished characteristics of OODBs is class hierarchy (also called inheritance hierarchy). A class hierarchy in an OODB means that a class can hand down the definitions of the class to the subclass of the class. In other words, a class is allowed to inherit the definitions of the class from the superclass. In this paper, we present performance evaluation metrics for class hierarchy in OODBs from a concurrency control perspective. The proposed performance metrics are developed to determine which concurrency control scheme in OODBs can be used for a given class hierarchy. In this study, in order to develop performance metrics, we use class hierarchy structure (both of single inheritance and multiple inheritance), and data access frequency for each class. The proposed performance metrics will be also used to compare performance evaluation for various concurrency control techniques.

Air Intake Door Control for the High Air Conditioning Performance (인테이크 도어 제어를 이용한 고성능 냉난방 시스템)

  • Park, Dongkyou;Kim, Yongchul
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.22 no.2
    • /
    • pp.17-22
    • /
    • 2014
  • Recently, the quick heating performance is an important issue in the car because engine power becomes so high. So car makers have been adapted the additional heating devices as like PTC(Positive Temperature Coefficient) heater. And the quick cooling performance is also important issue because its result is used in the IQS(Initial Quality Study). In this paper, control of the HVAC(Heating, Ventilation and Air Conditioning) intake door has been studied for the quick heating and cooling performance. Heating performance is improved $4.0^{\circ}C$ at $-20^{\circ}C$ ambient temperature after 20 minutes. And cooling performance is improved $1.5^{\circ}C$ at $35^{\circ}C$ ambient temperature after 10 minutes. In addition, intake door control system brings on the cost reduction because the flab door can be eliminated. This intake door control system has been adapted to the new developing cars.

Emergency Nurses' Perception and Performance of Tuberculosis Infection Control Measures (응급실 간호사의 결핵감염관리에 대한 인식과 수행)

  • Kim, Soo-Jung;Kang, Ji-Yeon
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.17 no.3
    • /
    • pp.351-361
    • /
    • 2010
  • Purpose: The purpose of this study was to investigate the perception and performance of tuberculosis infection control measures among emergency department nurses. Methods: A structured questionnaire was administered to a convenience sample of 227 emergency department nurses from 20 hospitals in B City. Results: The mean perception score was 4.52 out of a possible 5, and the mean performance score was 3.31 out of a possible 5. There were big differences between the perception and performance score on the items regarding wearing a gown or mask, while there were small differences on the items regarding dealing with patients' articles or medication. Conclusion: Emergency nurses showed high perception and low performance score on the items related to facilities and regulation such as visitation restriction or patient isolation. There was a positive correlation between perception and performance score. Conclusion: For emergency nurses, perception is higher than performance of tuberculosis infection control measures. The findings indicate the importance of providing continuing education for emergency nurse professionals seeking to update and increase their knowledge and to develop evidence-based nursing protocols on tuberculosis infection control in emergency department.

A Study on the Individual Room Control of Radiant Floor Heating System in Apartment Buildings (공동주택에서 바닥복사 난방시스템의 실별 제어에 관한 연구)

  • 김오봉;이미경;김광우;여명석
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.5
    • /
    • pp.421-429
    • /
    • 2004
  • In Korea, the radiant heating system has been widely used as a residential heating method, which has been modernized to use hot water running into the tubes embedded in the floor structure. According to the recent improvement of living standard of residential buildings, the requirement of the thermal comfort and energy saving in heating system has been raised. Until now, the radiant floor heating system has been controlled by room thermostat installed in the living room, but for better thermal comfort, an individual room control method is adopted as an alternative. Therefore, it is necessary to evaluate the control performance between the current control method and the individual room control method. In this study, the control performance between the two systems is evaluated through the field experiment. And the control performances of room air temperature and energy performances are analyzed through the simulation using TRNSYS. Firstly, the simulations are performed in the various outdoor conditions and the flow rates and the simulation results are analyzed for the control performances. Also, to evaluate the energy performance, the simulations are performed under the operating conditions in which the set-point of the room air temperature is fixed or changed according to the schedule of occupancy, and the simulation results are analyzed between the two methods.