Browse > Article
http://dx.doi.org/10.14346/JKOSOS.2017.32.6.89

Seismic Performance Assessment of High-Rise Building installed with Multiple Active Tuned Mass Dampers  

Park, Kwan-Soon (Department of Architectural Engineering, Dongguk University)
Ok, Seung-Yong (Department of Civil, Safety and Environmental Engineering, Hankyong National University)
Publication Information
Journal of the Korean Society of Safety / v.32, no.6, 2017 , pp. 89-97 More about this Journal
Abstract
The tuned mass damper (TMD) system was first proposed as an efficient vibration control method for high-rise buildings, and multiple TMD (MTMD) system was then proposed for the purpose of improving the robust performance. Thereafter, the active TMD (ATMD) is proposed to improve the vibration control performance over the TMD and MTMD systems. However, this system may experience an system-instability problem in case of the actuator malfunction. In order to overcome such limitations of actuator malfunction causing the instability of the structural system, in this study, we investigate the feasibility of the multiple ATMD (MATMD) system that facilitates both advantages of the MTMD and ATMD. Numerical example demonstrates that, when the proposed system is designed to have the same capacity as the ATMD, it shows a similar control performance to the ATMD, but also has very good adaptive control performance against the emergency situations such as actuator failures.
Keywords
multiple active tuned mass damper; high-rise building; adaptive control performance; actuator failure; seismic performance;
Citations & Related Records
Times Cited By KSCI : 5  (Citation Analysis)
연도 인용수 순위
1 B. F. Spencer Jr. and M. K. Sain, "Controlling Buildings: A New Frontier in Feedback", IEEE Control Systems Magazine on Emerging Technology, Vol. 17, No. 6, pp. 19-35, 1997.
2 A. Kareem, T. Kijewski and Y. Tamura, "Mitigation of Motions of Tall Buildings with Specific Examples of Recent Applications", Wind and Structures, Vol. 2, No. 3, pp. 201-251, 1999.   DOI
3 S. Ankireddi and H. T. Y. Yang, "Simple ATMD Control Methodology for Tall Buildings Subject to Wind Loads", Journal of Structural Engineering, Vol. 122, No. 1, pp. 83-91, 1996.   DOI
4 Q. S. Li, L. H. Zhi, A. Y. Tuan, C. S. Kao, S. C. Su & C. F. Wu, "Dynamic Behavior of Taipei 101 Tower: Field Measurement and Numerical Analysis", Journal of Structural Engineering, Vol. 137, No. 1, pp. 143-155, 2010.
5 R. Villaverde, "Reduction in Seismic Response with Heavily-damped Vibration Absorbers", Earthquake Engineering and Structural Dynamics, Vol. 13, pp. 33-42, 1958.
6 A. Nishitani and Y. Inoue, "Overview of the Application of Active/Semiactive Control to Building Structures in Japan", Earthquake Engineering and Structural Dynamics, Vol. 30, No. 11, pp. 1565-1574, 2001.   DOI
7 S.Y. Ok and S. M. Kim, "New Vibration Control Approach of Adjacent Twin Structures using Connecting Tuned Mass Damper", Journal of the Korean Society of Safety, Vol. 32, No. 3, pp. 92-97, 2017.
8 J. P. Den Hartog, "Mechanical Vibrations", 4th ed., McGraw Hill, Inc., New York, 1956.
9 F. Sadek, B. Mohraz, A. W. Taylor and R. M. Chung, "A Method of Estimating the Parameters of Tuned Mass Dampers for Seismic Applications", Earthquake Engineering and Structural Dynamics, Vol. 26, pp. 617-635, 1997.   DOI
10 M. Abe and Y. Fujino, "Dynamic Characterization of Multiple Tuned Mass Dampers and Some Design Formulas", Earthquake Engineering and Structural Dynamics, Vol. 23, No. 8, pp. 813-835, 1994.   DOI
11 K. S. Park, H. M. Koh, W. Park and S. Y. Ok, "Optimal Design of Multiple Tuned Mass Damper Considering Model Uncertainty of Structural System", Journal of Korean Society of Civil Engineers, Vol. 22, No. 3-A, pp. 533-543, 2002.
12 N. Yan, C. M. Wang and T. Balendra, "Optimal Damper Characteristics of ATMD for Buildings under Wind Loads", Journal of Structural Engineering, Vol. 125, No. 12, pp. 1376-1383, 1999.   DOI
13 K. S. Park and S. Y. Ok, "Seismic Response Enhancement through Stiffness Connection of Two Adjacent Buildings Equipped with ATMD", Journal of The Korean Society of Safety, Vol. 32, No. 5, pp. 47-53, 2017.   DOI
14 K. S. Park and S. Y. Ok, "Optimal Design of Hybrid Control System through Inter-building Connection", Journal of The Korean Society of Safety, Vol. 32, No. 5, pp. 47-53, 2017.
15 M. S. Kim, S. Y. Ok and K. S. Park, "Seismic Response Control of Adjacent Structures by Semi-active Fuzzy Control of Magneto-rheological Damper", Journal of the Earthquake Engineering Society of Korea, Vol. 13, No. 3, pp. 39-50, 2009.   DOI
16 A. K. Chopra, "Dynamics of Structures-theory and Applications to Earthquake Engineering", Prentice-Hall, Inc., Upper Saddle River, NJ, 1995.
17 F. L. Lewis, "Applied Optimal Control and Estimation", Prentice Hall PTR, 1992.
18 K. S. Park, H. M. Koh, S. Y. Ok and C. W. Seo, "Fuzzy Supervisory Control of Earthquake-excited Cable-stayed Bridges", Engineering Structures, Vol. 27, pp. 1086-1100, 2005.   DOI