• Title/Summary/Keyword: Performance Calculation

Search Result 2,385, Processing Time 0.027 seconds

Instantaneous Active/Reactive Power Compensation of Distribution Static Compensator using State Observer (배전용 정지형 보상기의 상태관측기를 이용한 순시 유효/무효전력 보상)

  • Kim, Hyeong-Su;Choi, Jong-Woo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.8
    • /
    • pp.1377-1382
    • /
    • 2008
  • DSTATCOM(distribution static compensator) is one of the custom power devices, and protects a distribution line from unbalanced and harmonic current caused by non-linear and unbalanced loads. Researches about DSTATCOM are mainly divided two parts, one is the calculation of compensation current and the other part is the current control. Conventional researches use a LPF(low pass filter) to eliminate ripple component at the calculation of compensation current. But this method has a problem that LPF's characteristics restrict the compensation performance of instantaneous active and reactive power. This paper proposes a calculation of compensation current using state observer that can be a counterproposal of conventional methods using LPF. Improved performance of instantaneous active and reactive power compensation was shown by experiments.

A Study on the Integrated System and Sensitivity Analysis for Line Capacity Calculation Model (선로용량 계산 모델의 통합과 통합 민감도 분석 체계에 관한 연구)

  • Kim, Mu-Ryong;Kim, Han-Sin;Lee, Chang-Ho;Kim, Bong-Seon;Kim, Dong-Hui;Hong, Sun-Heum
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2005.11a
    • /
    • pp.30-39
    • /
    • 2005
  • Line capacity calculation has been used to determine optimum efficiency and safe train service for train scheduling plan and investment priority order throughout detecting bottleneck section. Because of some problems of Yamagisi and UIC methods for line capacity calculation, developing of the method of line capacity calculation and evaluation for the Korea circumstance is important. This paper deals with the integrated system of TPS(Train Performance Simulator), PES(Parameter Evaluation Simulator), LCS (Line Capacity Simulator) and sensitivity analysis for line capacity calculation model.

  • PDF

Study on the Effect of the Impeller Diameter on the Performance of a Mixed-flow Pump (임펠러 외경 변경에 따른 사류펌프의 성능변화에 관한 연구)

  • Lee, Heon-Deok;Heo, Hyo-Weon;Suh, Yong-Kweon
    • The KSFM Journal of Fluid Machinery
    • /
    • v.15 no.4
    • /
    • pp.61-66
    • /
    • 2012
  • Nowadays, precise prediction of the pump performance becomes more important than ever before in high-value industries such as power plants and large ships. The power consumed in such pumps of large head and capacity definitely affects the efficiency of the entire system. In this study, we report the theoretical and CFD results used in prediction of the performance change caused by the reduction of impeller diameter. We have found that the theoretical calculation is somehow useful at least in estimating the very beginning condition for the CFD main calculation.

Estimation Model-based Verification and Validation of Fossil Power Plant Performance Measurement Data (추정모델에 의한 화력발전 플랜트 계측데이터의 검증 및 유효화)

  • 김성근;윤문철;최영석
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.2
    • /
    • pp.114-120
    • /
    • 2000
  • Fossil power plant availability is significantly affected by gradual degradations of equipment as operation of the plant continues. It is quite important to determine whether or not to replace some equipment and when to replace the equipment. Performance calculation and analysis can provide the information. Robustness in the performance calculation can be increased by using verification & validation of measured input data. We suggest new algorithm in which estimation relation for validated measurement can be obtained using correlation between measurements. Input estimation model is obtained using design data and acceptance measurement data of domestic 16 fossil power plant. The model consists of finding mostly correlated state variable in plant state and mapping relation based on the model and current state of power plant.

  • PDF

Performance Evaluation and Numerical Calculation of Flows through a Vaned Diffuser for Centrifugal Compressor (원심압축기용 베인 디퓨저 내부유동의 수치해석 및 성능평가)

  • Choi, Yun-Ho;Kang, Shin-Hyoung;Lee, Jang-Chun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.10
    • /
    • pp.1296-1309
    • /
    • 1999
  • A three dimensional compressible Navier-Stokes code is developed to analyze flowfields and performance of a vaned diffuser in a centrifugal compressor. It employs scalar implicit approximate factorization, finite volume formulation, second order upwind differencing and a two-equation $q-{\omega}$ turbulence model based on the integration to the wall. Pressure recovery and loss coefficients of a vaned diffuser are evaluated using a developed computer code. The simulated three dimensional flows show how through flow structure affects pressure recovery performance and loss coefficients of a vane for design and off-design inlet flow angles. Development of complex three dimensional flow over the inlet region and leading edge are very influential to the overall flow and performance.

Development of Hydrogen Recirculation Blower for Fuel Cell Vehicle by Flow Analysis (유동해석에 의한 연료전지용 수소 재순환 블로워 개발)

  • Shim, Chang-Yeul;Hong, Chang-Oug;Kim, Young-Soo
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.684-689
    • /
    • 2005
  • Parametric calculation were conducted to estimate performance of variable geometry of hydrogen recirculation blower for fuel cell vehicle. The pressure rise and efficiency are effected by change of the geometric parameter of impeller and casing, and stripper clearance under various mass flow. Hydrodynamic performance were evaluated, and also the inner flow fields were investigated by CFD. Calculated results show good coincidence with experimental test results of total pressure performance. Performance of model designed by parametric calculations satisfied experimental data of verification model.

  • PDF

Performance of Carbon Dioxide System for Freezing and Refrigeration (이산화탄소를 이용한 냉동·냉장 시스템의 성능연구)

  • Kim, Yoonsup;Yun, Rin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.2
    • /
    • pp.81-86
    • /
    • 2015
  • Performance of freezing and refrigeration systems in supermarket, which utilized $CO_2$ as a refrigerant, was investigated by using the Pack Calculation II. The configuration of simulated systems was basic parallel refrigeration system, cascade system, and two-stage system. The $CO_2$ cascade system showed higher COP than basic parallel R404A system by 13% for MT and 62% for LT, respectively. Among the $CO_2$ cascade systems, R717(MT)-$CO_2$(LT) showed the highest performance. Open-type intercooler method showed higher performance than liquid injection for the two-stage $CO_2$ systems.

Performance Analysis of a Dolphin-tail Rudder

  • Min K. S.;Chung K. N.;Kim Y. L
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.137-139
    • /
    • 2003
  • As a part of numerical and experimental research works for the prediction and improvement of ship's maneuvering performance, a study on the performance analysis of two different rudders has been carried out. While the planform shape and the aspect ratio of the rudders have been fixed, section shape has been changed. Conventional type of HMRI NP section and special type of dolphin-tail section have been employed. Performances of the rudders have been investigated by using CFD and compared with experimental data obtained in a wind tunnel. A commercial CFD program has been used to solve the RANS equations. Two-equation k-ro model has been applied to close the governing equations. Block-structured grids are used in the numerical calculation. Based upon the calculation results, the rudder with dolphin-tail section has shown a possibility of significantly improving rudder performance if utilized as the section of ship rudders.

  • PDF

Performance Evaluations of a Residential Small Multi-Refrigeration System Considering the Adiabatic Characteristics (단열 특성을 고려한 가정용 소형 멀티 냉동시스템의 성능에 관한 연구)

  • Lee, Moo-Yeon;Lee, Dong-Yeon;Joo, Young-Ju;Kim, Sang-Uk;Kim, Yong-Chan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.10
    • /
    • pp.868-875
    • /
    • 2007
  • In this paper, performance characteristics of a domestic kim-chi refrigerator are predicted by using the theoretical calculation and experimental method. The objective of this study is to find out the best design points of the refrigeration system and to calculate an adiabatic characteristic with variation to outdoor temperatures. The best design points such as refrigerant charge amount and capillary length were experimentally investigated. And the theoretical calculation is conducted as a function of calculation parameters and outdoor temperatures. According to this study results, the best design points of a refrigeration system with 2 rooms are 95 g of a refrigerant charge amount and 3500 / 3500 mm of capillary lengths and the best design points of a refrigeration system with 3 rooms are 100 g of a refrigerant charge amount and 3000/3000/6000mm of capillary lengths. And the power consumptions of both systems are 13.57 and 18.2 kWh/month. The worst part of heat loss is a front side of a domestic kim-chi refrigerator body.

Reward Design of Reinforcement Learning for Development of Smart Control Algorithm (스마트 제어알고리즘 개발을 위한 강화학습 리워드 설계)

  • Kim, Hyun-Su;Yoon, Ki-Yong
    • Journal of Korean Association for Spatial Structures
    • /
    • v.22 no.2
    • /
    • pp.39-46
    • /
    • 2022
  • Recently, machine learning is widely used to solve optimization problems in various engineering fields. In this study, machine learning is applied to development of a control algorithm for a smart control device for reduction of seismic responses. For this purpose, Deep Q-network (DQN) out of reinforcement learning algorithms was employed to develop control algorithm. A single degree of freedom (SDOF) structure with a smart tuned mass damper (TMD) was used as an example structure. A smart TMD system was composed of MR (magnetorheological) damper instead of passive damper. Reward design of reinforcement learning mainly affects the control performance of the smart TMD. Various hyper-parameters were investigated to optimize the control performance of DQN-based control algorithm. Usually, decrease of the time step for numerical simulation is desirable to increase the accuracy of simulation results. However, the numerical simulation results presented that decrease of the time step for reward calculation might decrease the control performance of DQN-based control algorithm. Therefore, a proper time step for reward calculation should be selected in a DQN training process.