• Title/Summary/Keyword: Percutaneous needle biopsy

Search Result 104, Processing Time 0.019 seconds

Robotized Percutaneous Biopsy (로봇을 이용한 경피 생체 검사)

  • Son, Jaebum;Kim, Kwang Gi
    • Journal of Biomedical Engineering Research
    • /
    • v.33 no.3
    • /
    • pp.105-113
    • /
    • 2012
  • Biopsy is a type of histopathological examinations, in which a physician samples cells or tissues from a patient's suspicious lesion. Such a lesion frequently resides deep inside human body, and then a percutaneous biopsy is therefore performed using a thick needle with the assistance of medical imaging such as computed tomography(CT) and magnetic resonance imaging(MRI). Recently modern robotic technology is being introduced to percutaneous biopsy in order to reduce any possible human error and hazard on physicians caused by medical imaging. After medical imaging locates the exact location of lesion, an optimization algorithm plans the path for a biopsy needle. Subsequently, a robot system moves the biopsy needle to the lesion in accurate and safe way with the control of a practitioner or automatically. In this article, we try to look into the state-of-art of percutaneous biopsy using such robotic technology. We classified percutaneous biopsy robots by mechanical characteristics and by imaging technology. Then, advantage and disadvantage of each class type are described as well as the basic description, and a few representative designs for each type are introduced. Current research issues of robotized percutaneous biopsy are subjectively selected for the readers' convenience. We emphasize the basic technology of actuator and sensors compatible with imaging technology to conclude this review.

Chest Wall Implantation of Lung Cancer After Percutaneous Fine Needle Biopsy -A Case Report (경피적 폐생검술에 의한 폐암의 흉벽 전이 -1례 보고-)

  • 심성보;이성호
    • Journal of Chest Surgery
    • /
    • v.30 no.4
    • /
    • pp.445-448
    • /
    • 1997
  • Percutaneous transthoracic fine needle biopsy has been widely used In the diagnosis of pulmonary lesions especially lung cancer. Onc of the rarest complication's is that malignant cells are implanted within the needle tract and developed a chest wall mass subsequently. Wc expcrlenccd a case of chest wall implantatio of lung cancer after percutaneous transthoracic floe needle biopsy. A 65-ycar old man had undergone bilobectomy (right upper lobe and right middle lobe)for squamous cell (·4rcinoma (TINOMO) of the lung. 60 days after percutaneous biopsy (48 days after operation), a tiny nodule (1 mm sized) was notcd at the right anterior chcst wall where the diagnostic fine needle biopsy had been performed before operation. This tiny mass was rapidly growing to 1.5 cm sized mass for 20 days. We carried out wide excision of chest wall mass and skin grafting, and confirmed squamous cell carcinoma histopathologically as same as the lung cancer.

  • PDF

The Usefulness of Fine Needle Aspiration Cytology of Bone Lesions (골 병변에서 세침흡인 세포검사의 유용성)

  • Kim, Bohng-Hee;Gong, Gyung-Yub
    • The Korean Journal of Cytopathology
    • /
    • v.13 no.2
    • /
    • pp.51-59
    • /
    • 2002
  • To determine the usefulness on fine needle aspiration cytology(FNAC) of bone lesions and the complementary role of FNAC and percutaneous needle biopsy, 75 cases of FNAC taken from bone lesions were analyzed. Correlations with histopathology were possible in 47 cases, including 14 cases of simultaneous core biopsy and 33 cases of subsequent open biopsy due to inadequate aspirates. Among 75 cases, 4 cases were benign tumors and tumor-like lesion, 11 cases were malignant primary bone tumors, 17 cases were metastatic tumors, and 43 cases were nonneoplastic bone lesions. The aspirates were adequate in 35 cases(46.7%), in all of which the discrimination between benignancy and malignancy was possible. The main reason for Inadequate aspirates was due to hypocellularity. In the cases of aspiration and core biopsy simultaneously done, the diagnostic accuracy of aspiration, core biopsy, and both were 57%(8/14), 78.6%(11/14), and 92.9%(13/14), respectively. We conclude that a final diagnosis based on cytology is possible with the adequate aspirates and the clinical and radiological findings. Also we confirm the complementary role between FNAC and core biopsy in bone lesions.

Chest Wall Implantation of Lung Cancer after Percutaneous Fine Needle Aspiration - Report of one case - (경피적 폐생검술후 흉벽에 전이된 폐암;1례 보고)

  • 원태희
    • Journal of Chest Surgery
    • /
    • v.25 no.7
    • /
    • pp.707-710
    • /
    • 1992
  • Percutaneous needle aspiration has been widely used in the diagnosis of pulmonary lesions, because it is a fairly simple procedure with good diagnostic accuracy and low complication rate. Among its complications, the spread of malignant cells along the needle tract is rare but serious one. We report a case of chest wall implantation of lung cancer after the percutaneous fine needle aspiration biopsy. A 57-year-old man had undergone a right upper lobectomy for squamous cell carcinoma [T2N0M0] of the lung, 3 months after the operation, a growing mass, located far from the previous thoracotomy incision, developed on the right anterior chest wall where the diagnostic thin needle biopsy had been performed before the lobectomy. A wide excision of the chest wall mass was performed, and permanent histology showed squamous cell carcinoma as noted before.

  • PDF

Chest Wall Implantation of Lung Cancer after Percutaneous Transthoracic Fine Needle Biopsy -A report of one case- (경피적 폐생검술에 의해 흉벽에 전이된 폐암 -1례 보고-)

  • U, Geon-Hwa;Kim, Dong-Won;Gwak, Yeong-Tae;Lee, Sin-Yeong
    • Journal of Chest Surgery
    • /
    • v.29 no.4
    • /
    • pp.458-460
    • /
    • 1996
  • Percutaneous transthoracic fine needle biopsy is a popular technique in the diagnosis ot'pulmonary and pleural diseases and its complication rate is very low. One of the rarest but potential complications is that of implantation of malignant cells along the needle tract and subsequent development of a chest wall mass . We experienced a case of chest wall implantation of lung cancer after percutaneous transthoracic fine needle biopsy. The patient was a 59 year old female who had undergone right upper lobectomy for squamous cell carcinoma of the lung (T,N,Mo). 6 months after operation, a loculated mass was palpated at the right posterior .chest wall where the percutaneous transthoracic fine needle biopsy had been performed before operation. We carried out wide excision of this mass and confirmed squamous cell carcinoma histopathologically.

  • PDF

The Role of Percutaneous Pleural Needle Biopsy in the Diagnosis of Lymphocyte Dominant Pleural Effusion (림프구 우위성 삼출성 늑막액의 진단에 있어서의 경피적 늑막 침 생검의 역할)

  • Yim, Jae-Joon;Kim, Woo-Jin;Yoo, Chul-Gyu;Kim, Young-Whan;Han, Sung-Koo;Shim, Young-Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.4
    • /
    • pp.899-906
    • /
    • 1997
  • Background : The percutaneous pleural needle biopsy have been regarded as cornerstone in the diagnosis of lymphocyte dominant pleural effusions of which acid fast bacilli smear and cytologic exam was negative. However, the complications of percutaneous pleural needle biopsy is not rare and its diagnostic efficacy is not always satisfactory. Recently, pleural fluid adenosine deaminase (ADA) and carcinoembryonic antigen (CEA) are widely accepted as markers of tuberculous pleurisy and malignant pleural effusion respectively. We designed this study to re-evaluate the role of percutaneous pleural needle biopsy in the diagnosis of lymphocyte dominant exudative pleural effusions whose AFB smear, cytologic exam was negative. Method : Retrospective analysis of 73 cases of percutaneous pleural needle biopsy in case of lymphocyte dominant exudative pleural effusions whose AFB smear and cytoloic exam was negative from Jan 1994 to Feb 1996 was done. Result : In 35 cases, specific diagnosis was obtained(all cases were tuberculous pleurisy), and in 30 cases specific diagnosis was not obtained in spite of getting adequate pleural tissues, and in the other 8 cases, percutaneous pleural biopsy failed to get pleural tissues. In 9 cases, complications were combined including pneuomothorax and hemothorax. All 49 cases of pleural effusions whose ADA value was higher than 40IU/L and satisfying other categories were finally diagnosed as tuberculous pleurisy, however, the pleural biopsy confirmed only 28 cases as tuberculous pleurisy. In 6 cases of pleural effusions of which CEA value is higher than 10ng/ml, the pleural biopsy made specific diagnosis in no case. Final diagnosis of above 6 cases consisted of 4 malignant effusions, 1 malignancy associated effusion and 1 tuberculous pleurisy. Conclusion : In the diagnosis of 73 cases of lymphocyte dominant pleural effusions of which acid fast bacilli smear and cytologic exam was negative, percutaneous pleural biopsy diagnosed only in 35 cases. In the diagnosis of tuberculous pleurisy, the positive predictive value of higher ADA than 40 IU/L in lymphocyte dominant pleural effusion with negative AFB smear and negative cytologic exam was 100%. And the diagnostic efficacy of pleural biopsy was 57%. In cases of effusions with high CEA than 10ng/ml 83% and 0% respectively. Finally, we concluded that percutaneous pleural needle biopsy in the diagnosis of AFB smear negative and cytologic exam negative lymphocyte dominant exudative pleural effusion was not obligatory. especially in effusions with high ADA and low CEA value.

  • PDF

Analysis of the Result and Merit of Computed Tomography Guided Percutaneous Needle Aspiration Biopsy of Focal Lung Lesion (CT 유도하 국소적 폐질환의 경피적 흡입생검의 장점과 결과 분석)

  • Chang, You-Song;Cho, Kil-Ho;Byun, Woo-Mock;Hwang, Mi-Soo;Park, Bok-Hwan
    • Journal of Yeungnam Medical Science
    • /
    • v.10 no.1
    • /
    • pp.127-134
    • /
    • 1993
  • Percutaneous needle biopsy of pulmonary lesion with use of fluoroscopic guidance is well established as a diagnostic tool but limited by the small size and inaccessibility of certain lesions. However, percutaneous needle biopsy has been used increasingly in relation to advance and the safty of smaller biopsy needle and new imaging modalities such as ultrasound and CT. CT, because of its characteristics of high resolution, allows tissue sampling with considerable safety from area that heretofore could not be visualized under fluoroscopy. The authors summarized 44 pulmonary lesions that underwent CT-guided transthoracic biopsy with fine-needle over a 14 month period and analyzed the sensitivity of PTNB. CT-guided PTNB was done with 20 gauge or 22 gauge Westcott biopoy needle(Manan medical products, USA). A diagnosis was made in 27 of 44 cases(61%) including malignany in 19 of 24 cases and benignancy in 8 of 20 cases. The pulmonary mass lesions were located at the peripheral zone of the lung field in 33 cases and at the central zone in 11 cases. Complications were observed in 2 cases which were pneumothorax and hemoptysis each but specific therapy was not required. The sensitivity of PTNB by one session was 61%(27/44). The sensitivity of malignancy was 79%(19/24) and benignancy was 40%(8/20). These results suggest the usefulness of PTNB using fine needles be increased in earlier diagnosis and improved staging of pulmonary nodular lesions without significant complications.

  • PDF

Characteristics of Needle Insertion Performance of Automated Biopsy Device for Robotic Needle Insertion Type Intervention: Insertion Depth and Accuracy (로봇 자동화 바늘삽입형 중재시술을 위한 자동화 생검장치의 바늘삽입 특성: 바늘삽입 깊이 및 삽입정확도)

  • Moon, Youngjin;Choi, Jaesoon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.7
    • /
    • pp.565-570
    • /
    • 2016
  • This paper presents the characteristics related to needle insertion of a robotic device for the automated biopsy procedure. The automated biopsy device, a main component of the robotic needle insertion type intervention system, allows performance of the full biopsy procedure, except for anesthesia, without direct handling of a radiologist or a tele-operated control. In this study, the needle length parameters corresponding to various insertion depths and precision for needle insertion of the automated biopsy device, are discussed. There were two combinations of needle length parameters for appropriate needle insertion and motion capture-based measurement was performed; 0.156 mm error for the 90 mm length commanded insertion displacement was measured. The pre-defined goal is a maximum 1 mm error and thus our measured error is within the acceptable range. In the repeatability check, it was also shown that the device can implement a highly accurate insertion.

A Case of Pulmonary Cryptococcosis in an Immunocompetent Male Patient Diagnosed by a Percutaneous Supraclavicular Lymph Node Biopsy

  • Sung, Ji Hee;Kim, Do Hoon;Oh, Mi-Jung;Lee, Kyoung Ju;Bae, Young A;Kwon, Kye Won;Lee, Seung Min;Kang, Ho Joon;Choi, Jinyoung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.78 no.3
    • /
    • pp.276-280
    • /
    • 2015
  • Cryptococcal pneumonia usually occurs in immunocompromised patients with malignancy, acquired immune deficiency syndrome, organ transplantations, immunosuppressive chemotherapies, catheter insertion, or dialysis. It can be diagnosed by gaining tissues in lung parenchyma or detecting antigen in blood or bronchoalveolar lavage fluid. Here we report an immunocompetent 32-year-old male patient with diabetes mellitus diagnosed with cryptococcal pneumonia after a ultrasound-guided percutaneous supraclavicular lymph node core needle biopsy. We treated him with fluconazole at 400 mg/day for 9 months according to the guideline. This is the first case that cryptococcal pneumonia was diagnosed from a percutaneous lymph node biopsy in South Korea.

Hematoma-Filled Pneumatocele after CT-Guided Percutaneous Transthoracic Needle Lung Biopsy: Two Case Reports (컴퓨터단층촬영 유도 경피적 바늘 생검 이후에 발생한 혈종으로 채워진 기종: 두 건의 증례 보고)

  • Se Ri Kang
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.1
    • /
    • pp.311-317
    • /
    • 2023
  • CT-guided percutaneous transthoracic needle biopsy (PTNB) plays a key role in the diagnosis of pulmonary abnormalities. Although the procedure is considered safe and effective, there exists a potential for complications, such as pneumothorax, hemorrhage, hemoptysis, air embolism, and tumor seeding. However, pneumatoceles after CT-guided PTNB have been rarely reported. Herein, we report two cases of pneumatoceles that developed immediately after PTNB for primary lung cancer. A pneumatocele filled with hematoma should be considered in cases with a newly developed nodule along the needle tract during short-term follow-up CT after PTNB.