• Title/Summary/Keyword: Penetration efficiency

Search Result 323, Processing Time 0.028 seconds

A Study on Forecast of Penetration Amount of High-Efficiency Appliance Using Diffusion Models (확산 모형을 이용한 고효율기기의 보급량 예측에 관한 연구)

  • Park, Jong-Jin;So, Chol-Ho;Kim, Jin-O
    • Journal of Energy Engineering
    • /
    • v.17 no.1
    • /
    • pp.31-37
    • /
    • 2008
  • At present, the target amount of demand-side management and investment cost of EE (Energy Efficiency) program, which consists of high-efficiency appliances, has been estimated simply by the diffusion function based on the real historical data in the past or last year. In the internal and external condition, the penetration amount of each appliance has been estimated by Bass diffusion model which is expressed by time and three coefficients. And enough acquisition of real historical data is necessary for reasonable estimation of coefficients. In energy efficiency, to estimate the target amount of demand-side management, the penetration amount of each appliance should be primarily forecasted by Bass diffusion model in Korea. On going programs, however, lightings, inverters, vending machine and motors have a insufficient real historical data which is a essential condition to forecast the penetration amount using a Bass diffusion model due to the short period of program progress. In other words, the forecast of penetration amount may not be exact, so that it is necessary for the method of forecast to apply improvement of method. In this paper, the penetration amount of high-efficiency appliances is forecasted by Bass, virtual Bass, Logistic and Lawrence & Lawton diffusion models to analyze the diffusion progress. And also, by statistic standards, each penetration is compared with historical data for model suitability by characteristic of each appliance. Based on the these result, in the forecast of penetration amount by diffusion model, the reason for error occurrence caused by simple application of diffusion model and preferences of each diffusion model far a characteristic of data are analyzed.

Evaluation of NOx Removal Efficiency of Photocatalytic Concrete for Road Structure (도로구조물 적용을 위한 광촉매 콘크리트의 질소산화물(NOx) 제거효율 평가)

  • Kim, Young Kyu;Hong, Seong Jae;Lee, Kyung Bae;Lee, Seung Woo
    • International Journal of Highway Engineering
    • /
    • v.16 no.5
    • /
    • pp.49-58
    • /
    • 2014
  • PURPOSES : In areas of high traffic volume, such as expressway across large cities, the amount of nitrogen oxides (NOx) emitted into the atmosphere as air pollution can be significant since NOx gases are the major cause of smog and acid rain. Recently, the importance of NOx removal has arisen in the world. Titanium dioxide ($TiO_2$), that is one of photocatalytic reaction material, is very efficient for removing NOx. The NOx removing mechanism of $TiO_2$ is the reaction of solar photocatalysis. Therefore, $TiO_2$ in road structure concrete need to be contacted with ultraviolet rays (UV) to be activated. In general, $TiO_2$ concretes are produced by replacement of $TiO_2$ as a part of concrete binder. However, considerable portion of $TiO_2$ in concrete cannot contact with the pollutant in the air and UV. Therefore, $TiO_2$ penetration method using the surface penetration agents is attempted as an alternative in order to locate $TiO_2$ to the surface of concrete structure. METHODS : This study aimed to evaluate the NOx removal efficiency of photocatalytic concrete due to various $TiO_2$ application method such as mix with $TiO_2$, surface spray($TiO_2$ penetration method) on hardened concrete and fresh concrete using surface penetration agents. The NOx removal efficiency of $TiO_2$ concrete was confirmed by NOx Analyzing System based on the specification of ISO 22197-1. RESULTS : The NOx removal efficiency of mix with $TiO_2$ increased from 11 to 25% with increasing of replacement ratio from 3 to 7%. In case of surface spray on hardened concrete, the NOx removal efficiency was about 50% due to application amount of $TiO_2$ with surface penetration agents as 300, 500 and 700g/m2. The NOx removal efficiency of surface spray on fresh concrete due to all experimental conditions, on the other hand, which was very low within 10%. CONCLUSIONS : It was known that the $TiO_2$ penetration method as surface spray on hardened concrete was a good alternative in order to remove the NOx gases for concrete road structures.

The Eeffect of Arc Length and Shield Gas on Penetration Aspect Ratio in A-TIG Welding (A-TIG 용접에서 용입 형상비에 미치는 아크길이와 실드가스의 영향)

  • Park, In-Ki;Ham, Hyo-Sik;Cho, Sang-Myung
    • Journal of Welding and Joining
    • /
    • v.26 no.6
    • /
    • pp.42-47
    • /
    • 2008
  • TIG welding enables to produce high quality weldment. However it has some problems such as shallow penetration and large distortion due to low penetration aspect ratio after welding. In order to overcome those problems, there are many ongoing studies on A-TIG welding, which use active flux. In this study, the effect of arc length and shield gas on penetration aspect ratio with melt-run welding on STS 304 6t, on which active flux was spreaded, was investigated. Arc length was changed from 1mm to 3mm, and aspect ratio became higher as arc length was decreased in this range. 100% Ar gas, Ar-$H_2$ mixed gas, Ar-He mixed gas, and 100% He gas were used as shield gas in this study. When Ar-$H_2$ mixed gas, Ar-He mixed gas, and 100% He gas were applied, penetration and melting efficiency were both increased as compared with 100% Ar gas. Aspect ratio was the highest with Ar-2.5% $H_2$ mixed gas.

Improvement of Fluid Penetration Efficiency in Soil Using Plasma Blasting (플라즈마 발파를 이용한 토양 내 유체의 침투 효율 개선)

  • Baek, In-Joon;Jang, Hyun-Shic;Song, Jae-Yong;Lee, Geun-Chun;Jang, Bo-An
    • The Journal of Engineering Geology
    • /
    • v.31 no.3
    • /
    • pp.433-445
    • /
    • 2021
  • Plasma blasting by high voltage arc discharge were performed in laboratory-scale soil samples to investigate the fluid penetration efficiency. A plasma blasting device with a large-capacity capacitor and columnar soil samples with a diameter of 80 cm and a height of 60 cm were prepared. Columnar soil samples consist of seven A-samples mixed with sand and silt by ratio of 7:3 and three B-samples by ratio of 9:1. When fluid was injected into A-sample by pressure without plasma blasting, fluid penetrated into soil only near around the borehole, and penetration area ratio was less than 5%. Fluid was injected by plasma blasting with three different discharge energies of 1 kJ, 4 kJ and 9 kJ. When plasma blasting was performed once in the A-samples, penetration area ratios of the fluid were 16-25%. Penetration area ratios were 30-48% when blastings were executed five times consecutively. The largest penetration area by plasma blasting was 9.6 times larger than that by fluid injection by pressure. This indicates that the higher discharge energy of plasma blasting and the more numbers of blasting are, the larger are fluid penetration areas. When five consecutive plasma blasting were carried out in B-sample, fluid penetration area ratios were 33-59%. Penetration areas into B-samples were 1.1-1.4 times larger than those in A-samples when test conditions were the same, indicating that the higher permeability of soil is, the larger is fluid penetration area. The fluid penetration radius was calculated to figure out fluid penetration volume. When the fluid was injected by pressure, the penetration radius was 9 cm. Whereas, the penetration radius was 27-30 cm when blasting were performed 5 times with energy of 9 kJ. The radius increased up to 333% by plasma blasting. All these results indicate that cleaning agent penetrates further and remediation efficiency of contaminated soil will be improved if plasma blasting technology is applied to in situ cleaning of contaminated soil with low permeability.

TBM disc cutter ring type adaptability and rock-breaking efficiency: Numerical modeling and case study

  • Xiaokang Shao;Yusheng Jiang;Zongyuan Zhu;Zhiyong Yang;Zhenyong Wang;Jinguo Cheng;Quanwei Liu
    • Geomechanics and Engineering
    • /
    • v.34 no.1
    • /
    • pp.103-113
    • /
    • 2023
  • This study focused on understanding the relationship between the design of a tunnel boring machine disc cutter ring and its rock-breaking efficiency, as well as the applicable conditions of different cutter ring types. The discrete element method was used to establish a numerical model of the rock-breaking process using disc cutters with different ring types to reveal the development of rock damage cracks and variation in cutter penetration load. The calculation results indicate that a sharp-edged (V-shaped) disc cutter penetrates a rock mass to a given depth with the lowest load, resulting in more intermediate cracks and few lateral cracks, which leads to difficulty in crack combination. Furthermore, the poor wear resistance of a conventional V-shaped cutter can lead to an exponential increase in the penetration load after cutter ring wear. In contrast, constant-cross-section (CCS) disc cutters have the highest quantity of crack extensions after penetrating rock, but also require the highest penetration loads. An arch-edged (U-shaped) disc cutter is more moderate than the aforementioned types with sufficient intermediate and lateral crack propagation after cutting into rock under a suitable penetration load. Additionally, we found that the cutter ring wedge angle and edge width heavily influence cutter rock-breaking efficiency and that a disc cutter with a 16 to 22 mm edge width and 20° to 30° wedge angle exhibits high performance. Compared to V-shaped and U-shaped cutters, the CCS cutter is more suitable for soft or medium-strength rocks, where the penetration load is relatively small. Additionally, two typical case studies were selected to verify that replacing a CCS cutter with a U-shaped or optimized V-shaped disc cutter can increase cutting efficiency when encountering hard rocks.

Spray and Combustion Characteristics of a Dump-type Ramjet Combustor

  • Lee, Choong-Won;Moon, Su-Yeon;Sohn, Chang-Hyun;Youn, Hyun-Jin
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.12
    • /
    • pp.2019-2026
    • /
    • 2003
  • Spray and combustion characteristics of a dump-type ram-combustor equipped with a V-gutter flame holder were experimentally investigated. Spray penetrations with a change in airstream velocity, air stream temperature, and dynamic pressure ratio were measured to clarify the spray characteristics of a liquid jet injected into the subsonic vitiated airstream, which maintains a highly uniform velocity and temperature. An empirical equation was modified from Inamura's equation to compensate for experimental conditions. In the case of insufficient penetration, the flame in the ram-combustor was unstable, and vice versus in the case of sufficient penetration. When the flame holder was not equipped, the temperature at the center of the ram-combustor had a tendency to decrease due to the low penetration and insufficient mixing. Therefore, the temperature distribution was slanted to the low wall of the ram-combustor. These trends gradually disappeared as the length of the combustor became longer and the flame holder was equipped. Combustion efficiency increased when the length of the combustor was long and the flame holder was equipped. Especially, the effect of the flame holder was more dominant than that of the combustor length in light of combustion efficiency.

Prediction of collection performance for a granular bed filter filled with various shapes of packing material (다양한 형상의 충전물로 채워진 충전층 집진기의 집진성능 예측)

  • Jae-Hyun Park;Myong-Hwa Lee
    • Particle and aerosol research
    • /
    • v.19 no.4
    • /
    • pp.145-154
    • /
    • 2023
  • Granular bed filters are widely used to remove particulate matter in flue gas and are filled with various shapes of packing material. The packing material plays an important role in determining the overall collection performance, such as pressure drop and collection efficiency. The pressure drop of a granular bed filter has been calculated using the Ergun equation, while the collection efficiency has been predicted using the log-penetration equation based on the single sphere theory. However, a prediction equation of collection efficiency for a granular bed filter filled with non-spherical packing materials has not been suggested yet. Therefore, in this study, three different shapes of packing materials (sphere, cylinder, and irregular) were prepared to propose a prediction equation. The pressure drop and collection efficiency in a granular bed filter filled with each shape of packing material were measured experimentally and compared with theoretically predicted values. We found that experimentally measured pressure drops matched well with values theoretically predicted using the Ergun equation considering the shape factor. However, experimental collection efficiencies were higher than theoretical ones predicted by the log-penetration equation using the single sphere theory. We modified the log-penetration equation by employing a shape factor and found a good relationship between experimental and theoretical collection efficiencies.

A Study on the Penetration Depth Measurement Methods of Inorganic Waterproofing Agent for Concrete (콘크리트용 무기계 방수제의 침투깊이 측정방법에 관한 연구)

  • Choi, Yun-Wang;Oh, Sung-Rok;Park, Man-Seok;Kim, Kyung-Hwan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.3
    • /
    • pp.116-124
    • /
    • 2014
  • Penetration depth of inorganic waterproofing agent is difficult to assess quantitatively because inorganic waterproofing agent for concrete is not an internal waterproof membrane. However, evaluation of penetration depth of inorganic waterproofing agent is one of the most important evaluation index to secure efficiency in a consistent penetration. Therefore, this paper was proposed penetration depth measurement method of inorganic waterproofing agent for concrete and the penetration depth of the conventional inorganic waterproofing agent have been evaluated through the proposed penetration depth measurement method. As a result of test, the measured penetration depth throught the proposed penetration depth measurement method of inorganic waterproofing agent showed that more than 90% reliability.

Estimation of Rebate Level for Energy Efficiency Programs Using Optimization Technique (최적화 기법을 이용한 에너지 효율 프로그램의 지원금 수준 산정)

  • Park, Jong-Jin;So, Chol-Ho;Kim, Jin-O
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.3
    • /
    • pp.369-374
    • /
    • 2008
  • This paper presents the evaluation procedures and the estimation method for the estimation of optimal rebate level for EE(Energy Efficiency) programs. The penetration amount of each appliance is estimated by applying price function to preferred diffusion model resulted from model compatibility test. To estimate the optimal rebate level, two objective functions which express the maximum energy saving and operation benefit are introduced and by multi-objective function which can simultaneously consider two objective functions the optimal rebate level of each appliance is estimated. And then, using the decided rebate level and each penetration amount, the priority order for reasonable investment of each high-efficiency appliance is estimated compared to the results of conventional method. Finally, using a benefit/cost analysis based on California standard practice manual, the economic analysis is implemented for the four perspectives such as participant, ratepayer impact measure, program administrator cost and total resource cost.

Heat Source Modeling of Laser Keyhole Welding: Part 1-Bead Welding (레이저 키홀 용접의 열원 모델링: Part 1-비드 용접)

  • Lee Jae-Young;Lee Won-Beom;Yoo Choong-Don
    • Journal of Welding and Joining
    • /
    • v.23 no.1
    • /
    • pp.48-54
    • /
    • 2005
  • Laser keyhole welding is investigated using a three-dimensional Gaussian heat source, and the heat source parameters such as the keyhole depth, welding efficiency and power density distribution factor are determined in a systematic way. For partial penetration, the keyhole depth is same as the penetration and is predicted using the experimental data. The welding efficiency is calculated using the ray-tracing method and the power density distribution factor is determined from the bead shape. Full penetration is classified into the transition, normal and excessive modes depending on the degree of keyhole opening. Thermal analysis of the bead-on-plate welds is conducted using the Gaussian heat source, and the calculated weld geometries show reasonably good agreements with the experimental results.