• Title/Summary/Keyword: Penetration control

Search Result 621, Processing Time 0.025 seconds

A Study on control of weld pool and torch position in GMA welding of steel pipe by using sensing systems (파이프의 가스메탈아크 용접에 있어 센서 시스템을 이용한 용융지 제어 및 용접선 추적에 관한 연구)

  • 배강열;이지형;정수원
    • Journal of Welding and Joining
    • /
    • v.16 no.5
    • /
    • pp.119-133
    • /
    • 1998
  • To implement full automation in pipe welding, it si most important to develop special sensors and their related systems which act like human operator when detecting irregular groove conditions. In this study, an automatic pipe Gas Metal Arc Welding (GMAW) system was proposed to full control pipe welding procedure with intelligent sensor systems. A five-axes manipulator was proposed for welding torch to automatically access to exact welding position when pipe size and welding angle were given. Pool status and torch position were measured by using a weld-pool image monitoring and processing technique in root-pass welding for weld seam tracking and weld pool control. To overcome the intensive arc light, pool image was captured at the instance of short circuit of welding power loop. Captured image was processed to determine weld pool shape. For weld seam tracking, the relative distance of a torch position from the pool center was calculated in the extracted pool shape to move torch just onto the groove center. To control penetration of root pas, gap was calculated in the extracted pool image, and then weld conditions were controlled for obtaining appropriate penetration. welding speed was determined with a fuzzy logic, and welding current and voltage were determined from a data base to correspond to the gap. For automatic fill-pass welding, the function of human operator of real time weld seam control can be substituted by a sensor system. In this study, an arc sensor system was proposed based on a fuzzy control logic. Using the proposed automatic system, root-pass welding of pipe which had gap variation was assured to be appropriately controlled in welding conditions and in torch position by showing sound welding result and good seam tracking capability. Fill-pass welding by the proposed system also showed very successful result by tracking along the offset welding line without any control of human operator.

  • PDF

Contact control of a probing manipulator contacting with plastically deformable objects (소성변형가능한 물체와 접촉하는 프로브 매니퓰레이터의 접촉제어)

  • 심재홍;조형석;김성권
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.221-224
    • /
    • 1996
  • Since impact phenomenon is highly nonlinear, the analysis and control of the contact motion has been a challenging subject. Various researches have been carried out mostly for the contact of a rigid robotic manipulator with a stiff and elastic environment. This paper is motivated by a new contact task: the in-circuit test of a printed circuit board. In this process, high speed contact occurs between a rigid probing manipulator and a plastically deformable work environment. A new dynamic model of the impact controlled probing task has been proposed, considering contact with the plastically deformable object. Approaching velocity conditions to avoid an excess of the allowable penetration depth and control the generated impact force properly are derived from the proposed model. The results of the simulation studies are made for various probing conditions and show the validity of the proposed model.

  • PDF

Assessment of Fertilizing Capacity of Human Spermatozoa Using Cryopreserved Hamster Oocytes (냉동보존된 햄스터 난자를 이용한 인간정자의 생식력 평가)

  • Pang, Myung-Geol;Chung, Ku-Min;Kim, Seok-Hyun;Shin, Chang-Jae;Kim, Jung-Gu;Moon, Shin-Yong;Lee, Jin-Yong;Chang, Yoon-Seok
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.19 no.2
    • /
    • pp.153-162
    • /
    • 1992
  • To solve the logistical problems of the sperm penetration assay (SPA) to provide just a sufficient number of hamster ova exactly when they are needed, a new method to cryopreserve the ova has been devised (1-step dehydration and 2-step thawing). After freezing & thawing of zona-intact (ZI) and zona-free (ZF) hamster ova according to this new method, the frozen-thawed ova were compared with fresh, control ova (FO) in terms of the degree of sperm penetration in SPA using semen samples from fertile donors, subfertile, and infertile male. Each sperm sample was capacitated for 42 hours inTEST-Yolk Buffer before insemination in SPA. In fertile doner, both the penetration rate and penetration index were lower in SPA using frozen ova (ZI; 92.4%, 6.2, ZF; 63.7%, 3.9) than those of SPA using fresh ova (99.3%, 8.4). There was a significant correlation between the penetration index of SPA using FO and ZI (p<0.001), and between those of SPA using FO and ZF and ova (p<0.001). In subfertile patient, both the penetration rate and penetration index were lowered in frozen ova (ZI; 62.3%, 1.3, ZF; 21.8%, 0.4) than those of fresh ova (74.8%, 1.8). There were significant correlation between the penetration rate and penetration index in ZI ova (p<0.05 and p<0.001, respectively). In infertile patient, both the penetration rate and penetration index were ZI; 3.1%, 0.0, ZF;0.0%, 0.0, respectively. There were significant correlation between the penetration rate and penetration index in ZI ova (p<0.05).

  • PDF

A Study on Non-contact Penetration and Rebound Measurement Device for Quality Control in Driven Piles (말뚝 시공관리를 위한 비접촉식 관입량 측정장치 활용에 관한 연구)

  • Seo, Seunghwan;Kim, Juhyong;Choi, Changho;Chung, Moonkyung
    • Journal of the Korean Geotechnical Society
    • /
    • v.38 no.11
    • /
    • pp.97-106
    • /
    • 2022
  • The domestic auger-drilled pile method generally manages the driving penetration (set) value with the final stage of construction. The penetration value has been estimated by manual measurement for a long time. The automation technology is yet to be applied due to workability and high-cost limitations, despite safety issues and lack of reliability in measured results. In this study, a non-contact pile penetration measurement device was developed. Further, the field performance was verified by comparing the measurements with a conventional automation device. In addition, the on-site field quality control method was analyzed using the penetration measuring device. The field experiments confirmed that more reliable bearing capacity estimation could calculate the dynamic damping coefficient and the modified Hiley formula with the developed device. Furthermore, it can be used for pile construction management from the bearing capacity viewpoint, even for piles not subjected to dynamic load tests. 

Study for Enhanced Skin Penetration of Cosmetics by Plasma-Sono Stimuli (플라즈마-초음파 자극에 의한 화장품의 피부 침투 증진 연구)

  • Yoonho Hwang;Hyeyoun Cho;Yujin Park;Hwijin Jang;Sanghyo Park;Jaehong Key
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.4
    • /
    • pp.275-283
    • /
    • 2023
  • The demand for skincare has increased due to the end of the COVID-19 pandemic, leading to a focus on skincare devices and technologies designed to improve the delivery of cosmetics. Among these technologies, skincare medical devices that utilize plasma therapy (Plasma) and sonophoresis (Sono) are commonly used in dermatology clinics. However, there is still a lack of quantitative analysis for transdermal absorption effects of Plasma and Sono skincare medical devices. In this study, we quantified enhanced transdermal absorption effects of Plasma and Sono devices through in-silico and ex-vivo studies. The Sono treatment demonstrated an increased transdermal absorption effect, showing a 10~13% difference in penetration compared to the control group in the in-silico experiment, and 159% and 184% increase in the ex-vivo experiment. The Plasma treatment revealed increased transdermal absorption effects, with a 1.0~2.5% penetration difference in the in-silico experiment, and a 124% increase in the ex-vivo experiment compared to the control group. We also observed a synergistic effect from the combined treatment of Plasma and Sono, as indicated by the highest increases of 197% and 242% in penetration. Furthermore, we have determined the optimal device settings and treatment conditions for Plasma-Sono skincare medical devices. Notably, higher on/off durations (Intensity levels) and longer Sono treatments resulted in greater transdermal absorption effects.

THE EFFECT OF POST-SPACE PREPARATION TIME ON THE APICAL SEAL OF ENDODONTICALLY TREATED TEETH (Post-Space형성시기가 치근단폐쇄에 미치는 영향에 관한 실험적 연구)

  • Moon, Eul-Won;Lee, In-Sook;Choi, Gi-Woon
    • Restorative Dentistry and Endodontics
    • /
    • v.13 no.1
    • /
    • pp.151-158
    • /
    • 1988
  • The purpose of this study was to evaluate the effect of canal filling methods and post-space preparation time on the apical seal of endodontically treated teeth. Seventy-six single-rooted human teeth were divided into 6 groups and each tooth was obturated and prepared post-space according to the purpose of this study. After all specimens were immersed in Indian ink, decalcified and cleared, the degree of dye penetration into the root canals observed by magnifying glass (X20) and measured by caliper. The results were as follows: 1. In the thermatic condensation, no significant difference in ink penetration occured when the post-spaces were created immediately after obturation or when they were made a week later. 2. In the lateral condensation, no significant difference in ink penetration existed between teeth whose post-space were prepared immediately or delayed. 3. In comparison of experimental groups and control groups, no significant difference showed when the groups were obturated with McSpadden compactor but when the teeth were laterally condensed, the experimental groups showed less ink penetration than controls. 4. Thermatic condensed teeth with McSpadden compactor were less ink penetration thn laterally condensed teeth.

  • PDF

The Effects of the GAIM Process Variables on the Penetration-Length Variations in a Unary Branch Type Runner Mold (편측분기형 러너 금형에서 가스사출 성형변수가 성형품의 중공부 길이 변화에 미치는 영향)

  • Han Seong Ryul;Park Tae Won;Jeong Yeong Deug
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.1
    • /
    • pp.137-142
    • /
    • 2005
  • Gas-Assisted Injection Molding(GAIM) is an innovative technology for producing plastic parts and has been received extensive attention in the plastic manufacturing industries. But, due to gas-polymer interacting during the gas injection phase, the process has significantly different characteristics from conventional injection molding and, therefore, the control of the process requires much technical knowledge in processing and materials. The experiment was performed about variations of gas-penetration length that is affected by filling imbalance resulting from the structure of runner. The Taguchi method was used for the design of experiment. The most effective factors for the gas-penetration length were the shot size and mold temperature. The most effective factors for the difference of the gas-penetration length were the melt temperature and shot size. This study also discussed the filling imbalance phenomenon in a unary branch runner type mold that has geometrically balanced runner.

Fast Fourier Transform Analysis of Welding Penetration Depth Using 2 kW CW Nd:YAG Laser Welding Machine

  • Kim, Do-Hyung;Chung, Chin-Man;Baik, Sung-Hoon;Kim, Koung-Suk;Kim, Jin-Tae
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.4
    • /
    • pp.372-376
    • /
    • 2008
  • We report experimental results on the correlations between welding penetration depth and the frequencies of the radiation from the welding pool. Various welding samples such as SUS304, brass, SUS316, etc. have been investigated with 2 kW CW Nd:YAG laser welding machine. The radiation signals from the plume generated by the interactions between the welding sample and laser with respect to the defocusing length was measured with fiber system collecting the plume signal. Analysis of the frequencies by using fast Fourier transform (FFT) shows that the penetration depth is deep as plume signal frequencies are low, shallow penetration depth for high frequencies. Frequencies up to 250 Hz for obtained signals can be analyzed with the discrete FFT. This is the useful method fur closed loop control of the laser power with respect to the welding penetration depth and is used for real time inspection of the welding quality.

A SCANNING ELECTRON MICROSCOPIC EVALUATION OF THE ROOT CANAL FILLING WITH ULTRASONIC ENDODONTIC INSTRUMENT (초음파 근관기구를 이용한 근관충전법의 근관폐쇄능에 관한 주사 전자현미경적 연구)

  • Choi, La-Young;Lee, In-Sook
    • Restorative Dentistry and Endodontics
    • /
    • v.15 no.2
    • /
    • pp.104-114
    • /
    • 1990
  • The purpose of this study was to evaluate the adaptation of root canal filling material to the dentinal wall of root canal and to compare the sealing ability of the root canal filling materials using ultrasonic endodontic instrument with injection-molded thermoplasticized gutta-percha filling method and lateral condensation method. Fifty fresh human single root exlracted for orthodontic treatment, were randomly selected, and instrumented by step-back technique. And then, the teeth were divided into 5 groups according to each root canal filling methods. In the experimental group 1 and group 2, the root canals were filled with gutta perdia cases using ultrasonic instrument with and without sealer. In the experimental group 3 and 4, using jection-moldeed thermoplasticized gutta-percha method by obtul$^{(R)}$ canals were filled with and without sealer. In the control group, the canals were filled with sealer by lateral candensation. And then, 5 teeth of each group were immersed in black Indian ink, decalcified and cleared. The depth of dye penetration into the root canal were evaluated with stereoscope (Reichert Ltd., USA). Among the 5 teeth remaining in each group, the single longituding grooves were made on the labial and lingual root surfaces and then immersed in the liquid nitrogen to fracture the teeth spontaneously without any distortions of gutta-percha. Each specimens were examined with X-650 Scanning Electron Microscope(Hitachi ltd, Japan) to show the adaptation to the canal wall, void, homogenicity of filling material and location of gutta-percha or sealer in the dentinal tubules of the root canal. The observations were as follows : 1. The experimental group 1 showed smaller mean dye penetration than control group, and showed the penetraton of sealer in the dentinal tubules of apical third of the root canal. 2. The experimental group 2 and group 4 showed the penetration of gutta-percha in the dentinal tubules of root canals. 3. The experimental group 1 and group 3 showed less mean dye penetration than the experimental group 2 and group 4. 4. The experimental group 1 and group 2 showed better adaptation of filling materials than control group.

  • PDF

Microorganism penetration in dentinal tubules of instrumented and retreated root canal walls. In vitro SEM study

  • Al-Nazhan, Saad;Al-Sulaiman, Alaa;Al-Rasheed, Fellwa;Alnajjar, Fatimah;Al-Abdulwahab, Bander;Al-Badah, Abdulhakeem
    • Restorative Dentistry and Endodontics
    • /
    • v.39 no.4
    • /
    • pp.258-264
    • /
    • 2014
  • Objectives: This in vitro study aimed to investigate the ability of Candida albicans (C. albicans) and Enterococcus faecalis (E. faecalis) to penetrate dentinal tubules of instrumented and retreated root canal surface of split human teeth. Materials and Methods: Sixty intact extracted human single-rooted teeth were divided into 4 groups, negative control, positive control without canal instrumentation, instrumented, and retreated. Root canals in the instrumented group were enlarged with endodontic instruments, while root canals in the retreated group were enlarged, filled, and then removed the canal filling materials. The teeth were split longitudinally after canal preparation in 3 groups except the negative control group. The teeth were inoculated with both microorganisms separately and in combination. Teeth specimens were examined by scanning electron microscopy (SEM), and the depth of penetration into the dentinal tubules was assessed using the SMILE view software (JEOL Ltd). Results: Penetration of C. albicans and E. faecalis into the dentinal tubules was observed in all 3 groups, although penetration was partially restricted by dentin debris of tubules in the instrumented group and remnants of canal filling materials in the retreated group. In all 3 groups, E. faecalis penetrated deeper into the dentinal tubules by way of cell division than C. albicans which built colonies and penetrated by means of hyphae. Conclusions: Microorganisms can easily penetrate dentinal tubules of root canals with different appearance based on the microorganism size and status of dentinal tubules.