• Title/Summary/Keyword: Penetration control

Search Result 626, Processing Time 0.024 seconds

A Study on Early Evaluation Method of Durability of PC Concrete According to the Accelerated Curing Conditions (촉진양생조건에 따른 PC콘크리트의 내구성 조기 평가기법 연구)

  • 김관호;박광수;신수균;이준구;장문기
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.169-174
    • /
    • 2002
  • We can consider that the study on early evaluation of compressive strength and durability of concrete is useful to raise safety of quality control of concrete. In this paper, was proposed to method early to predict strength and durability of concrete with parameter, such as Water/cement(W/C) ratio and steam curing conditions. Through analyzing the relationship between the compressive strength and the amount of chloride penetration into concrete specimens, a new formula early estimating durability of the concrete structure was suggested.

  • PDF

Status and issues of CAD/CAM technology in Korea (국내 CAD/CAM 현황과 문제점)

  • 이종원;김태수
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1986.10a
    • /
    • pp.437-442
    • /
    • 1986
  • Survey has been made to evaluate technological level and to identify research issues in CAD/CAM area. It is found out that major users of the CAD/CAM system are in mechanical and electronics as well as garment industries. Their experience shows that the impact of the CAD/CAM introduction is not yet noticeable in drafting man power and cost reduction. It is identified that the low penetration rate of CAD/CAM technology in industry is due to the lack of locally developed CAD/CAM softwares.

  • PDF

Improvement and Analysis of Chemical Inclination of Municipal Waste Landfill (도시폐기물 매립지반의 개량과 화학적 성향분석)

  • 김영욱;김인규
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1994.03a
    • /
    • pp.83-88
    • /
    • 1994
  • The DDC(dynamic deep compection) was carried out the main method of ground improvement for construction of municipal high way. The project area is composed of the municipal waste dumped, demolished building debris, coal ash and industrial waste made between 1983 and 1989. From the result of fileld measurement, it was found that waste landfill was compressed considerably (15 ~ 20% of full depth), and the strength was increased satisfactorily(20 ~ 120% of original N-value, 55 ~ 230% of original dynamic cone penetration resistance). And the chemical inclination of the municipal waste landfill was analyzed for expection and control of settlement.

  • PDF

Defending Against Today's Advanced Persistent Threats (최신 APT 해킹공격에 대한 방어)

  • Marpaung, Jonathan A.P.;Lee, HoonJae
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2012.11a
    • /
    • pp.954-957
    • /
    • 2012
  • Recent high profile attacks have brought the attention of governments, corporations, and the general public towards the dangers posed by Advanced Persistent Threats. This paper provides an analysis of the attack vectors employed by these actors by studying several recent attacks. We present recommendations on how to best defend against these threats by better classification of critical information infrastructure and assets, people protection, penetration tests, access control, security monitoring, and patch management.

Effects of Ferrous Sulfate and Ascorbic Acid on In Vitro Fertility and Sperm Lipid Peroxidation in the Pig (돼지의 체외수정능력과 정자의 Lipid Peroxidation에 있어서 Ascorbic Acid와 Ferrous Sulfate의 영향)

  • Park, C. K.;J. Y. Ann;Kim, I. C.;Lee, J. H.;B. K. Yang;Kim, C. I.;H. T. Cheong
    • Korean Journal of Animal Reproduction
    • /
    • v.25 no.4
    • /
    • pp.317-325
    • /
    • 2001
  • This study investigated the effect of ferrous sulfate (Fe$^{2+}$) and/or ascorbic acid (Asc) on fertilizing ability in vitro of frozen-thawed boar spermatozoa. Using chlortetracycline (CTC) fluorescence, the spermatozoa was treated in preincubation medium with control, Fe$^{2+}$(1 mM), Asc (0.5 mM) and Fe$^{2+}$Asc to assessed for acrosome reaction, and the oocyte penetration test to determine whether the Fe$^{2+}$ and/or Asc can promote the penetration ability in vitro. When frozen-thawed spermatozoa was washed with preincubation medium, there were significantly (P < 0.05) more acrosome-reacted in medium with Fe$^{2+}$Asc (38%) than control (27%). The penetration rates were also significantly (P < 0.05) higher in medium with Fe$^{2+}$Asc (76%) than control (55%). Next, the lipid peroxidation of sperm was evaluated on the basis of malondialdehyde production following same treatments. The addition of Fe$^{2+}$Asc to sperm suspension increases the formation of malondialdehyde. However, there were not significantly different under the all conditions. The sperm suspension were also treated with control, Fe$^{2+}$, Asc and Fe$^{2+}$/Asc and assayed for sulfhydry1(-SH) group content. In the Fe$^{2+}$/Asc group, sperm-SH group were higher than another groups. In spermatozoa treated with Fe$^{2+}$ and/or Asc, however, no changes in sperm -SH-groups were detected when compared to controls. In another experiment, the activity of sperm binding to zona pellucida was evaluated through binding to salt-stored porcine oocytes. In control and Asc treatment groups, sperm binding to zona pellucida were significantly (P < 0.05) higher than in medium with Fe$^{2+}$. On the other hand, there is not a significant increase in binding to zona pellucida with spermatozoa treated by Fe$^{2+}$/Asc. In summary, the present study suggests that Fe$^{2+}$/Asc causes an enhancement in fertilizing ability that is associated with penetration rate increased without change of spermatozoa binding capacity to homologous zona pellucida.o homologous zona pellucida.

  • PDF

Influences of Histamine on Permeability across Blood-brain Barrier (혈액-뇌장벽 투과성에 대한 히스타민의 영향)

  • Kim, Kee-Jin;Shin, Dong-Hoon
    • The Korean Journal of Physiology
    • /
    • v.2 no.2
    • /
    • pp.33-43
    • /
    • 1968
  • Histamine, 0.5 mg as histamine base in 4 ml of normal saline solution, was injected into rabbits anesthetized with nembutal and the mean blood pressure was kept in the range of $52{\sim}80\;mmHg$ for over one hour by supplemental additions. Following the injection of the test substances, 300 mg of urea and 200 mg of antipyrine intravenously, serial blood samples were obtained from the femoral artery and the internal jugular vein at $0.5{\sim}3$ minutes interval. The decreasing patterns in the concentrations of arterial and venous blood plasma samples were compared with each other. The ratio of the concentration of brain tissue to that of the final arterial plasma was also studied. By these measures the degrees of penetration of the test substances in the brain in the control and in the histamine treated rabbits were observed. The concentrations of antipyrine and urea in the arterial blood plasma were decreasing exponentially with respect to the time elapsed. The venous concentrations were anticipated to increase initially and to cross the arterial concentration curve in the point of equlibrium between the plasma and the tissue. On the contrary to the expectation venous concentration also revealed the decreasing tendency similar to that of arterial plasma. The similarity between these two curves, arterial and venous, would be atributable to the fact that the cerebral blood flow rate was large enough and the rising phase in the venous concentration curve was instantly over before serial blood samples were taken. Inspite of some similarity in the decreasing tedency in both concentration curves there were appreciable discrepancies between the arterial and venous plasma which would reflect the situation far from the equlibria among several compartments in the brain. Changes in plasma potassium levels caused by the injection of histamine or bleeding were observed, too. Using 8 rabbits as the control and 12 rabbits for the histamine treated group following results were obtained: 1. Both of the concentration curves, arterial and venous, declined rapidly at_first and slowly later on and approached same equilibrium concentration with the passage of time after a single injection. The time at which attained the same concentration was $2.0{\pm}0.54\;min.$ in the control and $4.3{\pm}1.92\;min.$ in the histamine treated group with respect to antipyrine. On the other hand in the case of urea they were $2.4{\pm}0.59\;min.$ in the control and $4.4{\pm}1.31\;min.$ in the histamine group, respectively. In the histamine treated group enlarged spaces for distribution of test substances were postulated. 2. The concentration of antipyrine in the brain tissue water revealed no significant differences between the control and experimental groups, showing $212{\pm}40.2\;mg/l$ in the control and $206{\pm}64.1\;mg/l$ in the histamine treated group. On the other hand urea revealed higher value in the histamine treated group than in the control, showing an enhanced penetration of urea into the tissue after injection of histamine. Urea concentration in the brain water was $32.3{\pm}3.36\;mg%$ in the control and $39.2{\pm}4.25\;mg%$ in the histamine treated group. 3. The distribution ratio of antipyrine in the brain tissue was very close to unity in the histamine treated animals as well as in the control. 4. The average of the distribution ratio of urea in the control animals was 0.77 and it showed the presence of blood-brain barrier with regard to urea. However in the histamine treated animals the distribution ratios climbed up to 0.86 and they were closer to unity than in the control animals. Out of 12 cases 5 were greater than 0.9 and 8 exceeded 0.85. It appeared that histamine enhanced the penetration of urea through the barrier. 5. Histamine injection and or hemorrhage caused an elevation of the concentration of potassium in plasma. In the event that histamine and hemorrhage were applied together the elevation of potassium exceed the elevation seen at the histamine alone. There was no evidence that the leakage of potassium from the brain tissue was dominant in comparison with the general leakage from the whole body.

  • PDF

Strategy based PSO for Dynamic Control of UPFC to Enhance Power System Security

  • Mahdad, Belkacem;Bouktir, T.;Srairi, K.
    • Journal of Electrical Engineering and Technology
    • /
    • v.4 no.3
    • /
    • pp.315-322
    • /
    • 2009
  • Penetration and installation of a new dynamic technology known as Flexible AC Transmission Systems (FACTS) in a practical and dynamic network requires and force expert engineer to develop robust and flexible strategy for planning and control. Unified Power Flow Controller (UPFC) is one of the recent and effective FACTS devices designed for multi control operation to enhance the power system security. This paper presents a dynamic strategy based on Particle Swarm Optimization (PSO) for optimal parameters setting of UPFC to enhance the system loadability. Firstly, we perform a multi power flow analysis with load incrementation to construct a global database to determine the initial efficient bounds associated to active power and reactive power target vector. Secondly a PSO technique applied to search the new parameters setting of the UPFC within the initial new active power and reactive power target bounds. The proposed approach is implemented with Matlab program and verified with IEEE 30-Bus test network. The results show that the proposed approach can converge to the near optimum solution with accuracy, and confirm that flexible multi-control of this device coordinated with efficient location enhance the system security of power system by eliminating the overloaded lines and the bus voltage violation.

Hybrid Control and Protection Scheme for Inverter Dominated Microgrids

  • Xu, Xiaotong;Wen, Huiqing;Jiang, Lin;Hu, Yihua
    • Journal of Power Electronics
    • /
    • v.17 no.3
    • /
    • pp.744-755
    • /
    • 2017
  • With the high penetration of various sustainable energy sources, the control and protection of Microgrids has become a challenging problem considering the inherent current limitation feature of inverter-based Distributed Generators (DGs) and the bidirectional power flow in Microgrids. In this paper, a hybrid control and protection scheme is proposed, which combines the traditional inverse-time overcurrent protection with the biased differential protection for different feeders with different kinds of loads. It naturally accommodates various control strategies such as P-Q control and V-f control. The parameter settings of the protection scheme are analyzed and calculated through a fast Fourier transform algorithm, and the stability of the control strategy is discussed by building a small signal model in MATLAB. Different operation modes such as the grid-connected mode, the islanding mode, and the transitions between these two modes are ensured. A Microgrid model is established in PSCAD and the analysis results show that a Microgrid system can be effectively protected against different faults such as the single phase to ground and the three phase faults in both the grid-connected and islanded operation modes.

A Study on Numerical Modeling of Dynamic CPT using Particle Flow Code (입자결합모델을 이용한 동적콘관입시험(DCPT)의 수치해석 모델링에 관한 연구)

  • You, Kwang Ho;Lee, Chang Su;Choi, Jun Seong
    • International Journal of Highway Engineering
    • /
    • v.16 no.2
    • /
    • pp.43-52
    • /
    • 2014
  • PURPOSES : To solve problems in current compaction control DCPT(Dynamic Cone Penetrometer Test), highly correlated with various testing methods, simple, and economic is being applied. However, it、s hard to utilize DCPT results due to the few numerical analyses for DCPT have been performed and the lack of data accumulation. Therefore, this study tried to verify the validation of numerical modeling for DCPT by comparing and analyzing the results of numerical analyses with field tests. METHODS: The ground elastic modulus and PR(Penetration Rate) value were estimated by using PFC(Particle Flow Code) 3D program based on the discrete element method. Those values were compared and analyzed with the result of field tests. Also, back analysis was conducted to describe ground elastic modulus of field tests. RESULTS : Relative errors of PR value between the numerical analyses and field tests were calculated to be comparatively low. Also, the relationship between elastic modulus and PR value turned out to be similar. CONCLUSIONS : Numerical modeling of DCPT is considered to be suitable for describing field tests by carrying out numerical analysis using PFC 3D program.

An Investigation of the Spray Characteristics according to Injection Conditions for a Gasoline Direct Injector (직분식 가솔린 인젝터의 분사 조건에 따른 분무 특성 분석)

  • 이기형;이창식;이창희;류재덕;배재일
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.5
    • /
    • pp.89-95
    • /
    • 2001
  • Recently GDI(Gasoline Direct Injection) engine is spotlighted to achieve higher thermal efficiency under partial loads and better performance at full loads. To realize this system, it is essential to make both stratified combustion and homogeneous combustion. When compared to PFI(Port Fuel Injection) engine, GDI engine needs more complicated control and optimal design with injection system. In addition, spray pattern must be optimized according to injection timing because ambient pressure in combustion chamber is also varied. Thus spray structure should be analyzed in details to meet various conditions. In this experimental study, two types of visualization system were developed to simulate compression stroke and intake stroke, respectively. With an increase of the ambient pressure, the penetration length tends to decrease due to rising resistance caused by the drag force of the ambient air. Spray characteristics impinged on the piston has a significant effect on mixture stratification around the spark plug. These results provide the information on macroscopic spray structure and design factors far developing GDI injector.

  • PDF