• Title/Summary/Keyword: Penetration control

Search Result 622, Processing Time 0.023 seconds

Performance of the Road Network with Market Penetration Rates and Traffic Volumes of Autonomous Vehicle using Traffic Simulation (시뮬레이션 기반 자율주행자동차 혼입률과 교통량 변화에 따른 도로 네트워크의 성능 분석)

  • Do, Myungsik;Jeong, Yumi
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.44 no.3
    • /
    • pp.349-360
    • /
    • 2024
  • The purpose of this study is to analyze the performance of the road network according to the penetration rate of autonomous vehicles (AV) of Level 4 or higher and the change in traffic volume. First, prior studies related to vehicle control variables of AV were reviewed, and future traffic demand in 2040, which is predicted to have a 50 % market share of AVs, was reflected in the simulation analysis. In addition, the change in traffic flow of continuous and intermittent flows was analyzed by increasing the AV market penetration rate and traffic volume of passenger cars, trucks, and buses by 25 % step by step from 0 to 100 %. As a result of the analysis, it was confirmed that the travel time increased as the traffic increased, and the pattern of decreasing the travel time due to the increase in the share of AVs, that is, the development of technology, can also be confirmed. Furthermore, it was also confirmed that the traffic speed showed a trend of increasing as the share of AVs increased. In this study, it was confirmed that the law of diminishing marginal rate of substitution (MRS) was satisfied by calculating the MRS according to the combination of traffic volume and speed while increasing the market penetration rate of AVs. Furthermore, it was confirmed that the convexity of the indifference curve was also satisfied in both intermittent and continuous traffic flow environments.

An Isolated Bidirectional Modular Multilevel DC/DC Converter for Power Electronic Transformer Applications

  • Wang, Zhaohui;Zhang, Junming;Sheng, Kuang
    • Journal of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.861-871
    • /
    • 2016
  • With high penetration of renewable energies, power electronic transformers (PETs) will be one of the most important infrastructures in the future power delivery and management system. In this study, an isolated bidirectional modular multilevel DC/DC converter is proposed for PET applications. A modular multilevel structure is adopted as switching valves to sustain medium voltages to achieve modular design and high reliability. Only one high-frequency transformer is used in the proposed converter, which significantly simplifies the circuit and galvanic insulation design. A dual-phase-shift modulation strategy is proposed to regulate the output power and achieve a simple voltage balancing control. A down-scaled (2 kW/20 kHz) prototype is constructed to demonstrate the proposed converter and verify the control strategy. The experimental results comply with the theoretical analysis well, with the highest power efficiency reaching 97.6%.

The Effects of Potato Puree and Bread Crumbs on Some Quality Characteristics of Low Fat Meatballs

  • Ergezer, Haluk;Akcan, Tolga;Serdaroglu, Meltem
    • Food Science of Animal Resources
    • /
    • v.34 no.5
    • /
    • pp.561-569
    • /
    • 2014
  • The purpose of this study was to determine the effects of using different amounts of potato puree (PP) (10 or 20%) and 10% bread crumbs (BC) as an extender and also control samples (C) with no added extender on chemical composition, energy values, cooking analyses, colour measurements, water holding capacity (WHC), penetration values, thiobarbituric acid value (TBA) and sensory analyses of meatballs. Meatball samples were cooked in a pre-heated $180^{\circ}C$ electric oven. Uncooked meatballs formulated with 20% PP had the highest moisture content. No significant differences were recorded for protein contents of uncooked samples. The highest cooking yield was found in samples extended with 10% BC. Increasing PP from 10% to 20% increased cooking yield of meatballs. 20% PP increased moisture and fat retention values and water holding capacity of meatballs. Meatballs with 10% BC had the lowest (the hardness in the texture) and meatballs with the 20% PP had the highest (the softness in the texture) penetration values. Formulating meatballs at a level of 20% resulted lower $L^*$ values. TBA values of control samples were higher than in PP added samples at the end of the storage period. Flavour scores for meatballs formulated with PP were higher than control and meatballs formulated with BC. Meatballs formulated with 10% PP had similar overall acceptability with meatballs added with 10% BC.

Hybrid Reference Function for Stable Stepwise Inertial Control of a Doubly-Fed Induction Generator

  • Yang, Dejian;Lee, Jinsik;Hur, Kyeon;Kang, Yong Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.1
    • /
    • pp.86-92
    • /
    • 2016
  • Upon detecting a frequency event in a power system, the stepwise inertial control (SIC) of a wind turbine generator (WTG) instantly increases the power output for a preset period so as to arrest the frequency drop. Afterwards, SIC rapidly reduces the WTG output to avert over-deceleration (OD). However, such a rapid output reduction may act as a power deficit in the power system, and thereby cause a second frequency dip. In this paper, a hybrid reference function for the stable SIC of a doubly-fed induction generator is proposed to prevent OD while improving the frequency nadir (FN). To achieve this objective, a reference function is separately defined prior to and after the FN. In order to improve the FN when an event is detected, the reference is instantly increased by a constant and then maintained until the FN. This constant is determined by considering the power margin and available kinetic energy. To prevent OD, the reference decays with the rotor speed after the FN. The performance of the proposed scheme was validated under various wind speed conditions and wind power penetration levels using an EMTP-RV simulator. The results clearly demonstrate that the scheme successfully prevents OD while improving the FN at different wind conditions and wind power penetration levels. Furthermore, the scheme is adaptive to the size of a frequency event.

Acoustic parameter delta of an aspirated voice in stroke patients (뇌졸중 환자 대상 흡인 음성의 음향변수 변동)

  • Kang, Young Ae;Jee, Sung Ju;Koo, Bon Seok;Jo, Cheolwoo
    • Phonetics and Speech Sciences
    • /
    • v.9 no.3
    • /
    • pp.85-91
    • /
    • 2017
  • The present study aimed to investigate the changes of acoustic parameters of the aspirated voice in stroke patients. The eighty-eight subjects diagnosed with cerebro-vascular accident were divided into 32 penetration/aspiration (P/A) and 56 Non-P/A groups according to the videofluroscopic swallowing study (VFSS) results, and 26 control subjects participated. All subjects preformed VFSS and vowel /a/ was recorded three times pre- and post VFSS. Since the variation in the acoustic parameters within a single phonation has been observed, we proposed a delta formula for the acoustic parameters which can reflect the temporal changes of the each parameter in an utterance. We measured from the voice data eight acoustic parameters: fundamental frequency (F0), standard deviation of F0 (F0_SD), Jitter, relative average perturbation (RAP), Shimmer, amplitude perturbation quotient (APQ), harmonic to noise ration (HNR), noise to harmonic ratio (NHR). Then we found parameters which show the meaningful biggest temporal change in an utterance using the suggested delta parameter. Among them, the deltas of shimmer and APQ were significantly different pre- and post VFSS. These deltas of the P/A and the control group were increased after VFSS, while those of the Non-P/A group was descended. The variation patterns of the P/A and the control group were similar but the change width of the P/A group was larger. The large variations in an aspirated phonation of the P/A group are thought to be caused by irregular changes in air resistance due to residual food on the vocal cords.

A Study on the Quality Control Method for Geotechnical Information Using AI (AI를 이용한 지반정보 품질관리 방안에 관한 연구)

  • Park, Ka-Hyun;Kim, Jongkwan;Lee, Seokhyung;Kim, Min-Ki;Lee, Kyung-Ryoon;Han, Jin-Tae
    • Journal of the Korean Geotechnical Society
    • /
    • v.38 no.11
    • /
    • pp.87-95
    • /
    • 2022
  • The geotechnical information constructed in the National Geotechnical Information DB System has been extensively used in design, construction, underground safety management, and disaster assessment. However, it is necessary to refine the geotechnical information because it has nearly 300,000 established cases containing a lot of missing or incorrect information. This research proposes a method for automatic quality control of geotechnical information using a fully connected neural network. Significantly, the anomalies in geotechnical information were detected using a database combining the standard penetration test results and strata information of Seoul. Consequently, the misclassification rate for the verification data is confirmed as 5.4%. Overall, the studied algorithm is expected to detect outliers of geotechnical information effectively.

Improvement in Active Power Control Methods for a Wind Farm Based on Modified Wind Turbine Control in Danish Grid Codes

  • Sim, JunBo;Song, Il-Keun;Lee, Yongseung;Lee, Hak-Ju;Choi, Yun-Hyuk
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.4
    • /
    • pp.1438-1449
    • /
    • 2018
  • The importance of power system stability has been emphasized with an increase of wind energy penetration in the power system. Accordingly, the guarantee on various control capabilities, including active and reactive power control of wind farms, was regarded as the most important aspect for the connection to the grid. To control the wind farm active power, the wind farm controller was introduced. The wind farm controller decides the power set points for each wind turbine generating unit and each wind turbine generating unit controls its power according to the set points from the wind farm controller. Therefore, co-relationship between wind farm controller and wind turbine controllers are significantly important. This paper proposes some control methods of wind farm active power control based on modified wind turbine control for power system stability and structures to connect wind turbine controllers to wind farm controller. Besides, this paper contributes to development of control algorithm considering not only electrical components but also mechanical components. The proposed contributions were verified by full simulation including power electronics and turbulent wind speed. The scenario refers to the active power control regulations of the Eltra and Elkraft system in Denmark.

A STUDY ON THE MICROLEAKAGE OF ROOT CANAL SEALERS (각종 근관충전용 시멘트의 미세누출에 관한 연구)

  • Cho, Ji-Sun;Hwang, Ho-Keel;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.21 no.1
    • /
    • pp.202-217
    • /
    • 1996
  • The purpose of this study was to compare the degree of microleakage of Glass-Ionomer root canal sealer possessed several enviable properties with that of the other sealers and to evaluate clinical performance. One hundred twenty single-rooted teeth were used in this experiment. The teeth were cleaned mechanically and immersed for 24 hours in 5.25% sodium hypochlorite and clinical crowns then were removed. After the root canals were instrumented using a step-back technique. one hundred twenty single-rooted teeth were divided into five groups of 24 in each. Group 1 : Tubli-Seal(Kerr Co., MI, U.S.A/ZOE-based), lateral condensation Group 2 : Sealapex(Kerr/Sybron, Romulus, MI/ $Ca(OH)_2$-based), lateral condensation Group 3 : AH 26(De Trey Co., Zurich Switzerland/Resin-based), lateral condensation Group 4 : Ketac-Endo(ESPE GMBH & CO. KG Seefeld:oberbay. Germany/ Glass Ionomer Cement-based), lateral condensation Control group : no sealer. lateral condensation And then. the root canals were obturated by lateral condensation technique with gutta-percha and experimental sealers. The control group were obturated without sealer. The teeth were placed in a vacuum chamber for 15 minutes and immersed 2% methylene blue under vacuum for 15 minutes. The teeth were passively stained for 1 week and 2 weeks and were cleared and evaluated for linear dye leakage using Tool maker's microscope(${\times}200$). The results were as follows: 1. There were statistically significant differences in the degree of dye penetration between the control group and experimental groups(p<0.05). 2. In the experimental groups, Sealapex($1.2871{\pm}0.9180mm$) exhibited the lowest mean value of dye penetration, followed by Ketac-Endo($1.4432{\pm}0.8082mm$), AH 26($1.5030{\pm}0.7752mm$) and Tubli-Seal($1.6458{\pm}1.0292mm$)(p>0.05). 3. There were statistically significant differences in the variation of microleakage between 1 week and 2weeks in Tubli-Seal and Seal apex groups (p<0.05). 4. The degree of dye penetration of all groups were increased as the time elapsed and AH 26 showed the lowest variation(+0.11) and Tubli-Seal(+ 1.03) showed the highest variation (p<0.001).

  • PDF

Effect of lining application techniques on microleakage in class II composite restorations (다양한 방식으로 적용한 이장재가 2급와동 복합레진 수복의 미세누출에 미치는 영향)

  • Hwang, Byung-Moon;Kim, Joo-Hyung;Park, Ji-Man;Millstein, Philip;Park, Eun-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.2
    • /
    • pp.145-151
    • /
    • 2014
  • Purpose: The purpose of this study was to investigate the microleakage in class II cavity resin restorations used with resin-modified glass ionomer (RMGI) lining material depending on two different applying methods; classical delivery method using a dental explorer and a specially designed rotating bur. Materials and Methods: A total thirty-six extracted teeth were prepared with a class II proximal box, and randomly divided into three groups: 1) control group with no lining added and the proximal box restored (Group I), 2) the second group used RMGI as a lining material which was spread with an explorer (Group II), 3) the third group used a specially designed rotating bur to thin out RMGI (Group III). All teeth were restored with the same manner using incrementally placed resin composite. All 36 teeth were prepared and sectioned for the dye penetration test, and observed with a stereomicroscope for scoring the dye penetration. Results: When RMGI liners were used, both groups using an explorer and the special bur with the liner had significantly less microleakage than the control group with no liner (P < 0.05). The 50% of the group with RMGI liner using the bur showed no microleakage under a dye penetration test whereas all the teeth in control group showed microleakage of different degrees. However, there was no statistically significant difference between Group II and Group III. Conclusion: RMGI is an effective lining material to decrease microleakage in class II composite resin restorations regardless of applying methods.

Automated Blind Control Strategy to Minimize Occupant's Distractions (재실자 방해 최소화를 위한 자동 블라인드 제어 방안)

  • Koo, So-Young;Yeo, Myoung-Souk;Seong, Yoon-Bok;Kim, Kwang-Woo
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.2
    • /
    • pp.84-92
    • /
    • 2013
  • Blinds are a common type of shading device and are increasingly operated automatically to overcome the limitations of manual operation. Automated blinds need to be controlled to maximize benefits of daylight in the point of occupant comfort and energy consumption. However, the previous control methods could cause occupant's distractions by the undesirable control time interval and amount of blind movement. A few researches suggested the control concept for minimizing occupant's distractions by automatic blind control, but they did not provide optimal control algorithm to be useful in practice. In this paper, we propose an optimal control algorithm for automated blinds that can maximize not only visual comfort but also sunlight penetration into buildings based on occupants' preferences on blind movement and sunlight. The proposed control algorithm can prevent solar glare on workplane and minimize occupant's distractions to maximize occupants' visual comfort.