• 제목/요약/키워드: Penetration Analysis

검색결과 1,386건 처리시간 0.028초

Evaluation on Sensitivity and Approximate Modeling of Fire-Resistance Performance for A60 Class Deck Penetration Piece Using Heat-Transfer Analysis and Fire Test

  • Park, Woo Chang;Song, Chang Yong
    • 한국해양공학회지
    • /
    • 제35권2호
    • /
    • pp.141-149
    • /
    • 2021
  • The A60 class deck penetration piece is a fire-resistance apparatus installed on the deck compartment to protect lives and to prevent flame diffusion in the case of a fire accident in a ship or offshore plant. In this study, the sensitivity of the fire-resistance performance and approximation characteristics for the A60 class penetration piece was evaluated by conducting a transient heat-transfer analysis and fire test. The transient heat-transfer analysis was conducted to evaluate the fire-resistance design of the A60 class deck penetration piece, and the analysis results were verified via the fire test. The penetration-piece length, diameter, material type, and insulation density were used as the design factors (DFs), and the output responses were the weight, temperature, cost, and productivity. The quantitative effects of each DF on the output responses were evaluated using the design-of-experiments method. Additionally, an optimum design case was identified to minimize the weight of the A60 class deck penetration piece while satisfying the allowable limits of the output responses. According to the design-of-experiments results, various approximate models, e.g., a Kriging model, the response surface method, and a radial basis function-based neural network (RBFN), were generated. The design-of-experiments results were verified by the approximation results. It was concluded that among the approximate models, the RBFN was able to explore the design space of the A60 class deck penetration piece with the highest accuracy.

J-적분을 이용한 후판 부분용입 다층용접재의 파괴 해석 (Fracture Analysis of Thick Plate for Partial Penetration Multi-pass Weldment Using J-integral)

  • 김석;송정일
    • 대한기계학회논문집A
    • /
    • 제26권2호
    • /
    • pp.300-307
    • /
    • 2002
  • Partial penetration welding joint is defined as groove welds welded from one side, without steel backing or groove welds welded from both sides but without back gouging. So it has an unwelded portion at the root of the weld. Study of partial penetration weldment fracture behavior includes residual stress analysis and fracture analysis. The J-integral loses its path independency in residual stress field. Therefore, it is necessary to introduce a new J-integral, J, which is defined including the effect of plastic deformation and thermal strain. In this study, theoretical formulation and program were developed for the evaluation of J-integral for the crack tip located in the weldment. Evaluations of fracture behavior were performed for partial penetration multi-pass weldment of 25.4mm thick plate by J-integral. From a point of fracture in partial penetration multi-pass welding, it seemed to be better to control root face smaller than 6.35mm.

레이저 심 용입 용저에서 3차원 열유동 해석에 관한 연구 (A Study on the Three-Dimensional Heat Flow Analysis in the Laser Welding for Deep Penetration)

  • 이규태;김재웅
    • Journal of Welding and Joining
    • /
    • 제18권3호
    • /
    • pp.76-82
    • /
    • 2000
  • In this study, three-dimensional heat flow in laser beam welding for deep penetration was analyzed by using F.E.M common code, and then the results were compared with the experimental data. The models for analysis are full penetration welds and are made at three different laser powers (6, 9.9, 4.5 kW) with two different welding speeds (5.8mm/s, 5mm/s). The characteristics of thermal absorption by the workpiece during deep penetration laser welding can be represented by a combination of line heat source through the workpiece and distributed heat source at the top surface due to the plasma plume above the top surface. This gives an insight into the way in which the beam interacts with the material being welded. The analyses performed with the combined heat source models show comparatively good agreement between the experimental and calculated melt temperature isotherm, i.e, the fusion zone boundary. The results are used to explain the "nail head" appearance of fusion zone, which is quite common in laser beam welds.eam welds.

  • PDF

FEM해석을 통한 콘크리트내 수분침투 및 확산 예측 (Prediction of Water Penetration and Diffusion in Concrete Through FEM Analysis)

  • 유조형;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2010년도 춘계 학술논문 발표대회 1부
    • /
    • pp.87-88
    • /
    • 2010
  • A permeability of concrete is a very important factors evaluating durability. So, we are carrying out a lot of relational data bases and experiment regarding a permeability. In order to evaluate a permeability of concrete, we are proceeding study on the water penetration and diffusion in concrete by water pressure. Because a way to evaluate a permeability of concrete has a limit. We will present a good method of evaluating durability of concrete using the water penetration depth of concrete by water pressure. To carry this out, we executed experiment with penetration depth of concrete by water pressure and verified it though FEM analysis.

  • PDF

외력을 고려한 양면 T-용접이음부의 음력해석 (Stress Analysis of Double T-Welded Joints Considering External Forces)

  • 김성환;방한서;방희선;송관형
    • Journal of Welding and Joining
    • /
    • 제19권2호
    • /
    • pp.215-220
    • /
    • 2001
  • In the T-joint welding, the complete penetration joint which is obtained by groove welding with edge preparation is generally required thor the safety and reliability of structures but this way have the some defects such as increase of working time, consumed welding electrode quantity and large welding deformation. If there is no probrem, in the strength, T-joint welding without edge preparation will be profitably understood in the economical and welding deformation side. In this paper, we performed the finite element analysis to understand the characteristics of welding residual stresses on two models, complete penetration joint have the edge preparation and incomplete penetration joint without edge preparation, respectively. Especially, we observed the relation between welding residual stress distributed on the notch of gap in the root and external force in the incomplete penetration joint without edge preparation.

  • PDF

Increasing Salesperson Performance through Relational Penetration Capability: The Implementation of Insurance Service Company Distribution

  • AQMALA, Diana;ARDYAN, Elia;PUTRA, Febrianur Ibnu Fitroh Sukono
    • 유통과학연구
    • /
    • 제19권5호
    • /
    • pp.35-48
    • /
    • 2021
  • Purpose: This research aims to analyze the influence of relational penetration capability on salesperson performance and the influence of customer orientation, customer knowledge accessibility, and salesperson-customer relationship quality on the relational penetration capability of the insurance service industry in Central Java. Research design, data, and methodology: This explanatory research involved 211 respondents. Path analysis was used to analyze the primary data obtained. Results: The customer orientation positively influences relational penetration capability and customer knowledge accessibility which can improve salesperson performance. The salesperson-customer relationship quality shows a positive impact on the salesperson's relational penetration capability, salesperson performance, and relational penetration capability which will lead to an improved salesperson-customer relationship. Higher knowledge levels of customer necessity have important implications for a salesperson's capability of finding potential customers and of fulfilling customers' requirements through careful analysis of necessity. Conclusions: The salespeople should be capable of building and maintaining a good relationship with their customers as an indication that salespeople of Insurance Service Company Distribution in Central Java have good performance.

Optimization of GMAW Process Parameters to Improve the Length of Penetration in EN 10025 S 235 Grade

  • Deshpande, M.U.;Kshirsagar, J.M.;Dharmadhikari, Dr. H.M.
    • Journal of Welding and Joining
    • /
    • 제35권1호
    • /
    • pp.74-78
    • /
    • 2017
  • In auto ancillary fabrication industry, GMAW is a very useful & important welding process and EN10025 S 235 Grade is common material used for manufacturing of two wheeler chassis. This research gives the detail influence of welding process parameters such as welding current, welding voltage, wire speed on the penetration in EN10025 S 235 Grade mild steel material. The experimentation of this research has been carried out by using three factors, three level Taguchi DOE method. To analyze & optimize the welding parameters & characteristics, analysis of variance, L9 orthogonal array & signal to noise ratio are used. Length of Penetration in addition to the depth of penetration is major concern in fillet welded joints, as the penetration decides the strength of the welded joint. After analysis of penetration in all 9 welded samples, optimize parameters readings verified & found probability value within 0.05.From this research it is come to know that welding current & welding voltage is major parameters which affects the penetration in welded joints.

침투자의 노즈 형상에 따른 콘크리트 침투성능 변화에 관한 수치적 연구 (Numerical Study on Variation of Penetration Performance into Concrete by Penetrator Nose Shape)

  • 주용원
    • 한국시뮬레이션학회논문지
    • /
    • 제27권3호
    • /
    • pp.109-116
    • /
    • 2018
  • 견고표적을 무력화하기 위해서는 높은 침투/관통성능을 가진 침투탄의 개발이 필수적이다. 침투탄의 설계를 위해, 본 논문에서는 노즈 형상 인자들이 침투자의 콘크리트 침투/관통성능에 미치는 영향을 분석하였다. 전산해석은 상용 전산해석 프로그램인 AUTODYN-2D를 사용하여 수행하였다. Forrestal의 시험결과를 사용하여 전산해석의 신뢰성을 검증하였으며, 침투자의 노즈 형상보다는 노즈 길이가 침투/관통성능에 더 큰 영향을 미치는 것을 확인하였다. 또한, 침투자의 노즈 길이가 일정할 경우, 노즈 팁 직경을 특정값까지 증가시켜 침투/관통성능을 향상시킬 수 있음을 확인하였다.

원자력발전소 관통부 충전구조의 내화성능평가에 관한 연구 (A Study on Assessment of Penetration Seals Performance of Nuclear Power Plants)

  • 조홍석;박준현;손봉세;임정순
    • 한국화재소방학회논문지
    • /
    • 제18권4호
    • /
    • pp.93-102
    • /
    • 2004
  • 원자력발전소에서 방화벽 관통부 내화충전구조는 화재가 발생장소 이외의 구역으로 전파되는 것을 차단하여 타구역에 설치된 안전에 중요한 기기를 보호하는 중요한 구성요소이다. 그러나 국내 장기 가동중 원전의 경우 관통부 충전구조의 내화성능을 입증하는 인증시험서가 구비되어 있지 않아 별도의 내화성능평가가 이루어져야 하고, 성능평가 결과가 적정 내화등급을 만족하지 못하는 관통부에 대해서는 관통물질의 재배치 둥의 구조변경이 이루어져야 한다 본 연구는 분석적인 방법에 의한 관통부 충전구조의 내화성능 평가기법을 정립하고. 분석적인 방법을 적용하여 실제 발전소에 설치된 관통부 충전구조의 내화등급을 결정하는 방법을 제시하였다. 이를 통하여 분석에 의한 관통부 충전구조의 내화성능평가방법은 내화인증시험서가 없는 국내 장기가동 원자력발전소에 효율적으로 적용될 수 있을 것으로 판단된다.

Dentinal tubule penetration of sodium hypochlorite in root canals with and without mechanical preparation and different irrigant activation methods

  • Renata Aqel de Oliveira;Theodoro Weissheimer;Gabriel Barcelos So ;Ricardo Abreu da Rosa ;Matheus Albino Souza;Rodrigo Goncalves Ribeiro ;Marcus Vinicius Reis So
    • Restorative Dentistry and Endodontics
    • /
    • 제48권1호
    • /
    • pp.1.1-1.11
    • /
    • 2023
  • Objectives: This study evaluated the dentinal penetration depth of 2.5% sodium hypochlorite (NaOCl) in root canals with and without preparation and different irrigant activation protocols. Materials and Methods: Sixty-three bovine mandibular incisors were randomly allocated to 6 groups (n = 10): G1, preparation + conventional needle irrigation (CNI); G2, preparation + passive ultrasonic irrigation (PUI); G3, preparation + Odous Clean (OC); G4, no preparation + CNI; G5, no preparation + PUI; G6, no preparation + OC; and CG (negative control; n = 3). Samples were filled with crystal violet for 72 hours. Irrigant activation was performed. Samples were sectioned perpendicularly along the long axis, 3 mm and 7 mm from the apex. Images of the root thirds of each block were captured with a stereomicroscope and analyzed with an image analysis software. One-way analysis of variance, followed by the Tukey post hoc test, and the Student's t-test were used for data analysis, with a significance level of 5%. Results: The NaOCl penetration depth was similar when preparation was performed, regardless of the method of irrigation activation (p > 0.05). In the groups without preparation, G6 showed greater NaOCl penetration depth (p < 0.05). The groups without preparation had a greater NaOCl penetration depth than those with preparation (p = 0.0019). Conclusions: The NaOCl penetration depth was similar in groups with root canal preparation. Without root canal preparation, OC allowed deeper NaOCl penetration. The groups without preparation had greater NaOCl penetration than those undergoing root canal preparation.