• 제목/요약/키워드: Penetrating resin

검색결과 17건 처리시간 0.022초

Surface penetrating sealant가 치경부 수복물의 미세누출에 미치는 영향 (EFFECT OF SURFACE PENETRATING SEALANT ON THE MICROLEAKAGE OF CERVICAL RESTORATIONS)

  • 김성원;조용범;홍찬의
    • Restorative Dentistry and Endodontics
    • /
    • 제26권1호
    • /
    • pp.64-76
    • /
    • 2001
  • Despite the improvements in bond strengths of dentin adhesives and resin-modified glass ionomers, the marginal seal of cervical restorations remains a concern. Microleakage at poorly sealed margins can result in staining, post-operative sensitivity, pulpal irritation, and recurrent caries. The objective of this study was to evaluate the effect of surface penetrating sealant(SPS) on the microleakage of cervical restorations. 45 extracted human teeth were selected, and Class V preparations were prepared on the both buccal and lingual surface of the teeth to the following dimensions : 1.5mm axially, 3mm mesiodistally, and 3mm incisogingivally. After cervical restoration with composite resin, compomer, glass ionomer each restoration was treated as three methods: No Tx., Scotchbond Multipurpose Adhesive$^{\circledR}$, Fortify$^{\circledR}$. The sections were examined with a stereomicroscope to determine the extent of microleakage at enamel and dentin margins. The results of this study were as follows. 1. All groups showed some microleakage. 2. Gingival cavity wall with cementum margin showed significantly higher leakage value than occlusal cavity wall with enamel margin. 3. The group treated with SPS showed significantly lower leakage value than no treated group(p<0.05). But there is no difference between Fortify$^{\circledR}$ and Scotchbond Multipurpose adhesive$^{\circledR}$. The results of this study suggest that SPS are effective in reducing microleakage of class V restorations. But it is certain that some microleakage still occurred despite the application of SPS.

  • PDF

확산한계전류밀도 고찰에 의한 방청도료의 내식성평가 (Evaluation of Corrosion Resistance of Anti-Corrosive Paint by Investigation of Diffusion Limiting Current Density)

  • 문경만;김윤해;이명훈;이인원;박현;전호환
    • 한국해양공학회지
    • /
    • 제23권4호
    • /
    • pp.64-68
    • /
    • 2009
  • It has been observed that coated steel structures deteriorate more rapidly than the designed lifetime due to acid rain caused by air pollution, etc. Therefore, improving the corrosion resistance of anti-corrosive paint is very important in terms of safety and the economic point of view. In this study, the corrosion resistance of five kinds of anti-corrosive paints, including the Acryl, Fluorine, and Epoxy resin series, were investigated with electrochemical methods, such as corrosion potential measurements, polarization curves, diffusion limiting current density, etc. As a result, the corrosion resistance of the F101 specimen with the fluorine resin series was found to be superior to the other specimens, while E100 with the epoxy resin series also showed a somewhat good corrosion resistance. Furthermore, it was observed that the amount of water and oxygen entering the inner side of a painted film increased with an increase in immersion time, irrespective of the kind of resin series. However, the oxygen diffusion limiting current density of a specimen with good corrosion resistance was relatively decreased compared to other specimens, because of the difficulty of oxygen diffusion penetrating to the inner side of the film. Consequently it is suggested that we can qualitatively evaluate the corrosion resistance of an anti-corrosive paint by measuring the diffusion limiting current density as an electrochemical method.

Peri-implant bone length changes and survival rates of implants penetrating the sinus membrane at the posterior maxilla in patients with limited vertical bone height

  • Kim, Hae-Young;Yang, Jin-Yong;Chung, Bo-Yoon;Kim, Jeong Chan;Yeo, In-Sung
    • Journal of Periodontal and Implant Science
    • /
    • 제43권2호
    • /
    • pp.58-63
    • /
    • 2013
  • Purpose: The aim of this study was to measure the peri-implant bone length surrounding implants that penetrate the sinus membrane at the posterior maxilla and to evaluate the survival rate of these implants. Methods: Treatment records and orthopantomographs of 39 patients were reviewed and analyzed. The patients had partial edentulism at the posterior maxilla and limited vertical bone height below the maxillary sinus. Implants were inserted into the posterior maxilla, penetrating the sinus membrane. Four months after implant insertion, provisional resin restorations were temporarily cemented to the abutments and used for one month. Then, a final impression was taken at the abutment level, and final cement-retained restorations were delivered with mutually protected occlusion. The complications from the implant surgery were examined, the number of failed implants was counted, and the survival rate was calculated. The periimplant bone lengths were measured using radiographs. The changes in initial and final peri-implant bone lengths were statistically analyzed. Results: Nasal bleeding occurred after implant surgery in three patients. No other complications were found. There were no failures of the investigated implants, resulting in a survival rate of 100%. Significantly more bone gain around the implants (estimated difference=-0.6 mm, P=0.025) occurred when the initial residual bone height was less than 5 mm compared to the >5 mm groups. No significant change in peri-implant bone length was detected when the initial residual bone height was 5 mm or larger. Conclusions: This study suggests that implants penetrating the sinus membrane at the posterior maxilla in patients with limited vertical bone height may be safe and functional.

함침재의 점도에 따른 벌크흑연의 기공 채움 효과 (The Pore-filling Effect of Bulk Graphite According to Viscosity of Impregnant)

  • 이상민;이상혜;노재승
    • 한국재료학회지
    • /
    • 제31권2호
    • /
    • pp.101-107
    • /
    • 2021
  • Pores produced by carbonization in bulk graphite process degrade the mechanical and electrical properties of bulk graphite. Therefore, the pores of bulk graphite must be reduced and an impregnation process needs to be performed for this reason. In this study, bulk graphite is impregnated by varying the viscosity of the impregnant. The pore volume and pore size distribution, according to the viscosity of the impregnant, are analyzed using a porosimeter. The total pore volume of bulk graphite is analyzed from the cumulative amount of mercury penetrated. The volume for a specific pore size is interpreted as the amount of mercury penetrating into that pore size. This decreases the cumulative amount of mercury penetrating into the recarbonized bulk graphite after impregnation because the viscosity of the impregnant is lower. The cumulative amount of mercury penetrating into bulk graphite before impregnation and after three times of impregnation with 5.1cP are 0.144 mL/g and 0.125 mL/gm, respectively. Therefore, it is confirmed that the impregnant filled the pores of the bulk graphite well. In this study, the impregnant with 5.1 cP, which is the lowest viscosity, shows the best effect for reducing the total pore volume. In addition, it is confirmed by Raman analysis that the impregnant is filled inside the pores. It is confirmed that phenolic resin, the impregnant, exists inside the pores through micro-Raman analysis from the inside of the pore to the outside.

한국 사찰벽화 채색층 고착처리제 적용 연구 (A Study on Painting Layer Fixative Processing of Mural Paintings of Buddhist Temples in Korea)

  • 이화수;한경순;이상진
    • 보존과학회지
    • /
    • 제29권1호
    • /
    • pp.81-92
    • /
    • 2013
  • 과거 국내 사찰벽화 보존처리는 유공성과 친수성의 특성을 고려한 재료선정이나 적합성에 대한 연구가 미흡한 상황에서 유럽의 재료 및 공법이 적용되었다. 그리고 합성수지를 사용하여 채색층 고착처리가 이루어진 벽화들은 현재까지 만족스럽지 못한 결과들이 나타나고 있다. 따라서 본 논문에서는 보존처리 효과를 규명하고자 사찰벽화 채색층 보강에 사용되는 고착제를 선별하여 고착처리 적용연구를 실시하였다. 고착제의 점도와 접착력 그리고 침투상태의 관계성을 파악한 결과 대부분 점도가 높은 시료에서 접착력이 증가하였고, 저점도의 시료에서는 접착력이 낮게 측정되었다. 시료별 고착제의 침투상태는 유사하지만 채색층과 토양 마감면의 상응 및 결합반응은 큰 차이점이 있는 것을 발견할 수 있었다. 동물성 아교와 MC의 경우, 채색층을 포함하여 토양과의 고착반응이 우수한 것으로 보이며, 토양과 견고하게 결속되어 안정적인 고착효과를 나타내는 것으로 판단된다. 합성수지계인 PVAc와 아크릴수지는 침투는 원활하지만, 토양과의 고착반응은 효과가 떨어지는 것으로 보인다.

노즐 축소부 수렴각이 고속 광섬유 피복유동에 미치는 영향 (EFFECTS OF CONVERGENT ANGLE OF NOZZLE CONTRACTION ON HIGH-SPEED OPTICAL FIBER COATING FLOW)

  • 박신;김경진;곽호상
    • 한국전산유체공학회지
    • /
    • 제21권4호
    • /
    • pp.11-18
    • /
    • 2016
  • A numerical study is conducted on the optical fiber coating flow in a primary coating nozzle consisting of three major parts: a resin chamber, a contraction and a coating die of small diameter. The flow is driven by the optical fiber penetrating the center of the nozzle at a high speed. The axisymmetric two-dimensional flow and heat transfer induced by viscous heating are examined based on the laminar flow assumption. Numerical experiments are performed with varying the convergent angle of nozzle contraction and the optical fiber drawing speed. The numerical results show that for high drawing speed greater than 30 m/s, there is a transition in the essential flow features depending on the convergent angle. For a large convergent angle greater than $30^{\circ}$, unfavorable multicellular flow structures are monitored, which could be associated with wall boundary-layer separation. In the regime of small convergent angle, as the angle increases, the highest resin temperature at the exit of die and the coating thickness decrease but the sensitivity of coating thickness on drawing speed and the maximum shear strain of resin on the optical fiber increase. The effects of the convergent angle are discussed in view of compromise searching for an appropriate angle for high-speed optical fiber coating.

인공타액 오염이 수종 상아질접착제와 상아질간의 결합에 미치는 영향 (INFLUENCE OF ARTIFICIAL SALIVA CONTAMINATION ON BONDING OF DENTIN ADHESIVES TO DENTIN)

  • 류미애;양규호;오원만
    • Restorative Dentistry and Endodontics
    • /
    • 제17권2호
    • /
    • pp.383-397
    • /
    • 1992
  • The purpose of this study was to evaluate the influence of artificial saliva contamination on bonding of several dentin adhesives to dentin. Sixty - three human molar teeth extracted within a month were used. Each tooth was sectioned longitudinally in a buccolingual direction to obtain 126 specimens. These specimens were randomly divided into three groups and were treated by Scotchbond 2, Gluma and All bond. Each group was subdivided into three subgroups; normal group not contaminated with artificial saliva, contaminated with artificial saliva and dried group, and contaminated with artificial saliva and washed and dried group. Enamel/dentin bonding agent(Dental Adhesive of Scotchbond 2) was applied and light cured on the treated dentin surfaces. Thereafter P - 50 were cured on them, and specimens were stored in $37^{\circ}C$ artificial saliva for 24 hours before measuring shear bond strength. Shear bond strengths were determined using an universal testing machine with cross head speed 1mm/min and SEM examinations were conducted to evaluate the resin - dentin interface and degree of penetrating resin string into the dentinal tubules. The following results were obtained. 1. Normal groups not contaminated with artificial saliva showed greater shear bond strength than any other group contaminated with artificial saliva(P<0.01). 2. The shear bond strengths showed no significant difference between washed groups with distilled water and not washed groups after contamination with artificial saliva(P>0.05). 3. In normal groups, the shear bond strength of A group was significantly greater than in any other group(P<0.01). 4. In Sand G groups, fractures after shear bond strength tests occured adhesively on resintooth interface in all specimens. But in A groups, fracture of the normal group occured cohesively in dentin and fracture of the contaminated groups occured adhesively and cohesively. 5. On SEM examination, the number of resin strings penetrated into dentinal tubules were the greatest in normal groups, followed by, in descending order, washed groups and not washed groups after contamination with artificial saliva.

  • PDF

Use of Resin Infiltrant to Prevent Discoloration after Teeth Whitening

  • Min, Ji-Hyun
    • 치위생과학회지
    • /
    • 제22권3호
    • /
    • pp.156-163
    • /
    • 2022
  • Background: This study attempted to apply resin infiltrant (RI) as a method to maintain the effect of tooth bleaching treatment and compared it with fluoride varnish (FV) or artificial saliva to evaluate the effect. Methods: Sixty healthy lozenge specimens were classified into five groups. Group 1 was the negative control group, and discoloration was induced after artificial saliva treatment of the tooth specimen (G1S+C). Group 2 was a positive control group, in which pigmentation was induced after bleaching treatment and artificial saliva treatment (G2 B+S+C). Coloration was induced in group 3 (experimental group 1) after bleaching treatment and artificial saliva treatment, followed by application of fluorine varnish (G3B+FV+S+C). Coloration was induced in Group 4 (experimental group 2) after applying RI after bleaching treatment and artificial saliva treatment (G4B+RI+S+C). Pigmentation was induced in group 5 (experimental group 3) after bleaching treatment and artificial saliva treatment, followed by acid treatment (etching) and treatment with RI (G5B+E+RI+S+C). Coffee and wine were used to induce discoloration. The lightness value (L*) of the CIE L*a*b* color system was obtained by image analysis. Kruskal-Wallis H analysis was performed for the mean difference in L* values by group. Results: When coloration was induced with coffee, there was no significant difference in L* value between artificial saliva (G2 B+S+C), FV (G3B+FV+S+C), and RI (G4B+RI+S+C, G5B+E+RI+S+C) groups. There was no significant difference in L* values between the artificial saliva (G2 B+S+C), FV (G3B+FV+S+C), and RI (G4B+RI+S+C, G5B+E+RI+S+C) groups, even in the case of wine induced coloration. Conclusion: It was confirmed that artificial saliva or RI treatment had similar effects to the FV previously used to maintain the effect of tooth bleaching treatment.

밀리미터 전자기파를 이용한 콘크리트 내부 자가치유 캡슐의 위치 측정을 위한 3D 프린팅 자가치유 캡슐의 공진 주파수 분석 (Resonance frequency analysis of 3D printed self-healing capsules for localization of self-healing capsules inside concrete using millimeter wave length electromagnetic waves)

  • 임태욱;성호;이영준;호걸;김상유;정원석
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 가을 학술논문 발표대회
    • /
    • pp.243-244
    • /
    • 2022
  • In this paper, experiments were conducted on signal amplification of polymer capsules for application to Ground Penetrating Radar so as to enable real-time monitoring of polymer capsules inside concrete using the Morphology Dependent Resonance phenomenon. A TEM CELL and a vector network analyzer were used to analyze the difference in resonance frequency depending on the material of the sphere and the presence or absence of fracture. In order to manufacture a capsule of a size that can be measured using millimeter waves used in GPR, we manufactured a capsule with a 3D printer and analyzed the effects of the presence or absence of coating and the size of the capsule on the resonance frequency. Resonant frequency or signal amplification is more affected by diameter than coating. The capsule showing the highest amplification is the resin-coated 50 mm diameter capsule with a 316-fold increase and the lowest capsule is the uncoated 10 mm diameter capsule with a signal amplification of 11.9 times. These results demonstrate the potential of GPR to measure the position and state of self-healing capsules, which are small-sized polymers, in real time using millimeter waves.

  • PDF

매설파이프 감지를 위한 지하 투과 레이다 모래 모형조 실험 (Ground penetrating radar testing in a sand tank for detection of buried pipes)

  • 김형수
    • 지구물리
    • /
    • 제1권1호
    • /
    • pp.59-68
    • /
    • 1998
  • 지하 투과 레이다를 이용한, 지하 매설물의 감지 여부 및 반사 신호 특성을 규명하기 위하여 모래 모형조 실험을 수행하였다. 매설물의 직경과 매립 심도의 비율은 최대 24 %, 최소 4 %로 다양하게 설정되었으며, 매설물의 재질은 금속제, 합성수지 및 목재가 사용되었다. 실험 결과, 지하수면이 매설물 하부에 위치한 경우, 목재를 제외한 모든 매설물이 심도와 직경에 상관없이 강한 반사파를 보여 주었다. 한편, 지하수면이 매설물 상부에 위치한 경우, 지하레이다를 이용한 매설물 감지가 매우 어려웠다. 그러나 이 경우에도 모형 탱크의 바닥에서의 반사 신호는 뚜렷이 감지되었으며, 이는 단순히 전자기파의 감쇠 이외에 타 요소가 매설물의 반사파 신호 발생을 저하시키는 것으로 사료된다. 본 실험 결과, 현장에서 단순히 매설물의 수평적인 위치를 감지하려고 할 경우, 수직 반사 방식의 지하레이다 조사가 경제적, 시간적으로 효율적이지만, 매설물의 수직위치, 지층의 전자기파 투과 속도, 지하수면 조사 등, 정밀한 지하 정보 획득을 목적으로 하는 경우, 적어도 부분적인 공심점 자료를 획득 할 수 있는 방식의 조사가 수행되어야 할 것으로 사료된다.

  • PDF