• Title/Summary/Keyword: Pendulum Test

Search Result 126, Processing Time 0.036 seconds

Relationship Between Pendulum Test Measurements of Post-Stroke Spasticity (뇌졸중 후 강직 평가를 위한 진자검사 측정값의 상관관계)

  • Kim, Yong-Wook
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.5
    • /
    • pp.325-332
    • /
    • 2010
  • The purpose of this study was to investigate the relationship between three quantitative measures of the pendulum test for spasticity in strokes: The relaxation index, the number of oscillations, and the duration of oscillations. Twenty-six stroke subjects participated in the study. Correlations among these measures of spasticity used Pearson's correlation coefficient. There was a statistically significant positive correlation between the relaxation index and number of oscillations in strokes (r=.881, p<.01). In addition there was significant positive correlation between the relaxation index and duration of oscillations (r=.896, p<.01), and between the number of oscillations and duration of oscillations (r=.938, p<.01). Thus, it is possible to use the number of oscillations and duration of oscillations as quantitative measures of spasticity, rather than the relaxation index, which is more complicated to obtain. According to the result of this study, the use of the simple and objective measurements of the number of oscillations and the duration of oscillations are required clinically in the quantitative measures of spasticity in the future.

Quantitative Evaluation of Spasticity through Separation of Reflex and Mechanical Component Related to Spasticity in Hemiplegic Patients (편마비 환자 경직의 반사적 및 역학적 성분의 분리를 통한 경직의 정량적 평가)

  • Kim, Chul-Seung;Eom, Gwang-Moon;Kim, Ji-Won;Ryu, Je-Chung;Kang, Sung-Jae;Kim, Yo-Han;Park, Byung-Kyu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.7
    • /
    • pp.142-149
    • /
    • 2009
  • The aim of this study was to identify both the mechanical and reflex properties associated with spasticity in hemiplegic patients. Ten hemiplegic patients were included in this study. Multiple pendulum tests were executed for each subject, and knee joint angle and EMG of Rectus Femoris muscle were measured. The neuromusculoskeletal system model was developed from generally accepted mechanism and identified through minimization of the error in the model-predicted pendulum trajectories. The identification was successful in terms of small error in simulated kinematics and high sensitivity and precision of simulated torque against EMG activity. The reflex threshold showed significant difference between different clinical scores (p<0.01) and significant negative correlation (r=-0.93) with the EMG duration. It is expected that the suggested method may help in understanding mechanisms underlying spasticity.

Pendulum Impact Tests for 16by16 Through Welded Spacer Grids with Optimized H type Springs (선용접방법으로 제작된 $16{\times}16$ 최적화 H형 스프링 지지격자에 대한 진자식충격시험)

  • Kim, J.Y.;Yoon, K.H.;Song, K.N.
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1803-1806
    • /
    • 2007
  • The General roles of a spacer grid(SG) are providing a lateral and vertical support for fuel rods, promoting a mixing of coolant and keeping guide tubes straight so as not to impede a control rod insertion under any normal or accidental conditions. To evaluate the impact characteristics of a SG such as impact velocity, critical buckling strength and duration time, a few types of impact tests for SGs have been conducted. In a previous study, a new welding method, a through-welding method, was proposed to increase critical buckling strength of a SG without any design change or material change and was verified by impact tests with $7{\times}7$ partial SG specimens.In this paper, the effect of through-welding method in case of a $16{\times}16$ full-size SG is investigated by pendulum impact tests with $16{\times}16$ SG specimens. And the increase of critical buckling strength for full-size SGs is measured by comparison with impact results of spot-welded and through-welded SGs.

  • PDF

A New Method for the Identification of Joint Mechanical Properties (관절계 역학적 특성의 정량적 평가방법)

  • 엄광문;김석주;한태륜
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.11
    • /
    • pp.209-218
    • /
    • 2004
  • The purpose of this paper is to suggest a practical and simple method for the identification of the joint mechanical properties and to apply it to human knee joints. The passive moment at a joint was modeled by three mechanical parts, that is, a gravity term, a linear damper term and a nonlinear spring term. Passive pendulum tests were performed in 5 fat and 5 thin men. The data of pendulum test were used to identify the mechanical properties of joints through sequential quadratic programming (SQP) with random initial values. The identification was successful where the normalized root-mean-squared (RMS) errors between the simulated and experimental joint angle trajectories were less than 10%. The parameter values of mechanical properties obtained in this study agreed with literature. The inertia, gravity and the damping constant were greater at fat men, which indicates more resistance to body movement and more energy consumption fer fat men. The suggested method is noninvasive and requires simple setup and short measurement time. It is expected to be useful in the evaluation of joint pathologies.

A Study on the Parameter Analysis for the Quantitative Evaluation of Spasticity Implementing Pendulum Test (경직의 정량 평가를 위한 진자실험의 변수분석)

  • Lim, Hyun-Kyoon;Lee, Young-Shin;Cho, Kang-Hee;Chae, Jin-Mok;Kim, Bong-Ok
    • Proceedings of the KSME Conference
    • /
    • 2000.04a
    • /
    • pp.268-273
    • /
    • 2000
  • Velocity-dependent increase in tonic stretch reflexes is one of the prominent characteristics of spasticity. It is very important to evaluate spasticity objectively and quantitatively before and after treatment for physicians. An accurate quantitative biomechanical evaluation for the spasticity which is caused by the disorder of central nervous system is made in this study. A sudden leg dropper which is designed to generate objective testing environment at every trial gives very effective environment for the test. Kinematic data are archived by the 3-dimensional motion analysis system($Elite^{(R)}$, B.T.S., Italy). Kinematic data are angle and angular velocity of lower limb joints, and length and lengthening velocity of lower limb muscle. A program is also developed to analyze the kinematic data of lower limb, contraction and relaxation length of muscles, and dynamic EMG data at the same tim. To evaluate spasticity quantitatively, total 31 parameters extracted from goniogram, EMG and muscle model are analyzed. Statistical analysis are made for bilateral correlations for all parameters. The described instrumentation and parameters to make quantitative and objective evaluation of spasticity shows good results.

  • PDF

Real-Time Motion Tracking Detection System for a Spherical Pendulum Using a USB Camera (USB 카메라를 이용한 실시간 구면진자 운동추적 감지시스템)

  • Moon, Byung-Yoon;Hong, Sung-Rak;Ha, Manh-Tuan;Kang, Chul-Goo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.9
    • /
    • pp.807-813
    • /
    • 2016
  • Recently, a spherical pendulum attached to an end-effector of a robot manipulator has been frequently used for a test bed of residual vibration suppression control in a multi-dimensional motion. However, there was no automatic tracking system to detect the current bob position on-line, and there was inconvenience to not be able to store the bob position in real time and plot the trajectory. In this study, we developed a two-dimensional, real-time bob-detecting system using a digital USB camera, of which the key is hardware component design and software C programming for fast image processing and interfacing. The developed system was applied to residual vibration suppression control of a two-dimensional spherical pendulum that is attached at the end-effector of a two degree-of-freedom SCARA robot, and the effectiveness of the developed system has been demonstrated.

Acoustic Characteristics of Watermelon According to Impact Conditions (타격조건에 따른 수박의 음파특성)

  • 최동수;최규홍;이영희;이강진;김만수
    • Journal of Biosystems Engineering
    • /
    • v.27 no.1
    • /
    • pp.67-76
    • /
    • 2002
  • This study was conducted to investigate the effects of impact conditions on the acoustic characteristics of a watermelon. The study was crucial to develop a device for nondestructive internal quality evaluation of a watermelon by an acoustic impulse response method. An impact device was constructed with a pendulum to hit the watermelon, a microphone to detect the acoustic impulse responses, and a digital oscilloscope and computer to store and analyze the data. The selected samples were Guemcheon cultivar watermelons(Citrulus Vulgaris Schrad) harvested on Oct. 20,1998. Sixty watermelons were tested on flour different types of sample holders, with four kinds of ball made of different materials, at four bevels of the angular position of the pendulum and distance from the watermelon to the microphone. Since the magnitudes of frequencies obtained by hitting with the steel and rubber ball were relatively small at the bandwidths of above 500 Hz, it was shown that the steel and rubber ball were not suitable far a hitting ball in the pendulum to get informations on internal quality of the watermelon. In case of using broth of the wood and acryl ball, almost the same and good acoustic responses were shown on the wide range of frequency bandwidth. Therefore, it seemed that the acryl ball was more suitable to the test than the wood ball in considering its mechanical properties. The acoustic characteristics of the watermelon were not shown a significant difference between the types of sample holder. The amplitudes of the acoustic signals and the magnitudes of frequencies from the whole samples increased with increase of the angular position of pendulum and with decrease of the distance from the watermelon to the microphone. However, the resonance resonance of the sample were almost the same regardless of the angular positions and the distances.

Mechanical performance analysis of an electromagnetic friction pendulum system based on Maxwell's principle

  • Mao Weikang;Li Xiaodong;Chen Enliang
    • Earthquakes and Structures
    • /
    • v.27 no.2
    • /
    • pp.143-154
    • /
    • 2024
  • Friction pendulums typically suffer from poor uplift-restraining. To improve the uplift-restraining and enhance the energy dissipation capacity, this article proposed a composite isolation device based on electromagnetic forces. The device was constructed based on a remote control system to achieve semi-active control of the composite isolation device. This article introduces the theory and design of an electromagnetic chuck-friction pendulum system (ECFPS) and derives the theoretical equation for the ECFPS based on Maxwell's electromagnetic attraction equation to construct the proposed model. By conducting 1:3 scale tests on the electromagnetic device, the gaps between the practical, theoretical, and simulation results were analyzed, and the accuracy and effectiveness of the theoretical equation for the ECFPS were investigated. The hysteresis and uplift-restraining performance of ECFPS were analyzed by adjusting the displacement amplitude, vertical load, and input current of the simulation model. The data obtained from the scale test were consistent with the theoretical and simulated data. Notably, the hysteresis area of the ECFPS was 35.11% larger than that of a conventional friction pendulum. Lastly, a six-story planar frame structure was established through SAP2000 for a time history analysis. The isolation performances of ECFPS and FPS were compared. The results revealed that, under horizontal seismic action, the horizontal seismic response of the bottom layer of the ECFPS isolation structure is greater than that of the FPS, the horizontal vibration response of the top layer of the ECFPS isolation structure is smaller than that of the FPS, and the axial force at the bottom of the columns of the ECFPS isolation structure is smaller than that of the FPS isolation structure. Therefore, the reliable uplift-restraining performance is facilitated by the electromagnetic force generated by the device.

Seismic Performance Evaluation of a Cone-type Friction Pendulum Bearing System (원추형 마찰진자베어링의 내진성능평가)

  • Jeon, Bub-Gyu;Chang, Sung-Jin;Park, Kyung-Rock;Kim, Nam-Sik;Jung, Duk-Young
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.15 no.2
    • /
    • pp.23-33
    • /
    • 2011
  • In this study, a CFPBS (Cone-type Friction Pendulum Bearing System) was developed which controls the acceleration delivered to the structure to prevent damage and degradation of the critical communication equipment in case of an earthquake. The isolation performance of the CFPBS was evaluated by numerical analysis. The CFPBS was manufactured in the shape of a cone differenced from the existing FPS (Friction Pendulum System), and a pattern was engraved on the friction surface. The natural frequencies of the CFPBS were evaluated from a free-vibration test with the seismic isolator system consisting of four CFPBSs. In order to verify its earthquake-resistant performance, a numerical analysis program was created from the equation of the CFPBS induced from the equations of motion. A simplified theoretical equation of the CFPBS was proposed to manufacture the equipment which could demonstrate the necessary performance. Artificial seismic waves satisfying the maximum earthquake scale of the Korean Building Code-Structural (KBC-2005) were created and verified to review the earthquake-resistant performance of the CFPBS by numerical analysis. The superstructural mass of the CFPBS and skew angle of the friction surface were considered for numerical analysis with El Centro NS (1940), Kobe NS (1995) and artificial seismic waves. The CFPBS isolation performance evaluation was based on the results of numerical analysis and the executed comparative analysis between the results from numerical analysis and the simplified theoretical equation under the same conditions.