• Title/Summary/Keyword: Peel Strength

Search Result 343, Processing Time 0.024 seconds

Effect of Photoinitiators on Adhesion Properties of 2-EHA/AA PSA (광개시제의 종류에 따른 2-EHA/AA 점착제의 접착특성)

  • Yoon, Hong-Beom;Kim, Ho-Gyum;Min, Kyung-Eun
    • Polymer(Korea)
    • /
    • v.38 no.4
    • /
    • pp.491-495
    • /
    • 2014
  • Pressure sensitive adhesive (PSA) based on 2-ethylhexyl acrylate (2-EHA)/acrylic acid (AA) copolymer was synthesized using different photoinitiators. Results showed that PSA with Irgacure$^{(R)}$651 (benzyldimethylketal) and Irgacure$^{(R)}$184(1-hydroxy-cyclohexylphenyl ketone) proved to be good for adhesion properties. This may be attributed to strong absorption near 350 nm wavelength and also high solubility in monomer mixtures. The addition of Irgacure$^{(R)}$819, bisacylphosphine oxides as a photoinitiator caused cohesive failure with high loading in a peel test owing to the additional radical formation. It is assumed that the insoluble photoinitiator reacts with oxygene, which may act as a hydrogen donor.

Self Diagnosis Technique of Concrete Structure Repaired and Strengthened by Carbon fiber Sheets Using Optical fiber Sensors (광섬유 센서를 이용한 탄소섬유시트 보수보강 콘크리트구조물에서의 자기진단기법)

  • Kim, Ki-Soo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.2
    • /
    • pp.133-139
    • /
    • 2003
  • In order to extend the life time of building and civil infra-structure, nowadays, patch type fibrous composite materials are widely used. Repaired concrete columns and beams gain the stiffness and strength, but they lose toughness and show brittle failure. Usually, the cracks of concrete structures are visible with naked eyes and the status of the structure in the life cycle is estimated with visible inspection. After repairing of the structure, crack visibility is blocked by repaired carbon sheets. Therefore, structural monitoring after repairing is indispensible and self diagnosis method with optical fiber sensor is very useful. In this paper, peel-out effects is detected with optical fiber sensors and the strain difference between main structure and repaired carbon sheets when they separate each other.

Measurements of Adhesion Strength Using Scratch Test (스크래치 시험을 통한 접합력 측정)

  • Lee, Chang-Myeon;Heo, Jin-Yeong;Lee, Hong-Gi
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2015.11a
    • /
    • pp.354-354
    • /
    • 2015
  • 코팅 층과 소지 사이의 접합력 평가를 위하여 박리 시험법(Peel Off Test), 블리스터 시험법(Blister Test), 압입균열 시험법(Indentation Test), 직접 인장 시험법(Direct Full Off Test), 스카치 테이프 시험법(Scotch Tape Test), 그리고 스크래치 시험법(Scratch Test) 등이 사용되어 왔다. 이 중 박리 시험법과 스카치 테이프 시험법이 산업계에서 일반적으로 사용되고 있다. 전자 산업계에서 많이 사용되고 있는 박리시험법은 금속박막과 절연체 기판 사이의 접합력을 간단하게 측정할 수 있으며, 실험값의 재현성이 뛰어난 장점이 있다. 또한, 측정하는 동안 만들어지는 박리 곡선(Peel Curve)로부터 분석의 신뢰성 여부를 확인할 수 있다. 이러한 장점에도 불구하고 박리 시험법 특성 상 금속 코팅층의 강도가 금속 피막/기판간 접합 강도를 초과하여야 하기 때문에 수백 nm 이하의 박막의 접합력 측정에는 적용하기가 어렵다. 이에 반하여, 스카치 테이프 분석법은 일정길이의 접착 테이프를 박막 표면에 붙인 후 다시 떼어내면서 접착력을 평가하는 방법으로, 박막의 접합력 평가에 적용이 가능하다. 그러나 이 방법은 합격 불합격 여부를 판정하는 정성적인 방법으로 정량평가가 어렵다. 또한, 박막에 접착 테이프를 붙일때의 압력, 테이프를 박리할 때의 각도 및 속도를 일정하게 제어하기가 쉽지 않아 결과의 신뢰성이 높지 않다. 스크래치 테스트는 탐사침(Stylus)을 이용하여 박막의 표면에 하중을 증가시키면서 기판을 이동하여, 피막의 균열이나 박리될 때의 임계 하중값 (Critical Load; Lc)을 측정하는 방법이다. 이 방법은 시편 준비가 쉽고 간단하여 빠른 분석이 가능하고, 수백 nm 이하의 박막에도 적용 가능하다. 또한, 접합력을 정량화 할 수 있기 때문에 변수에 따른 접합력 비교가 용이하다는 장점이 있다. 이와 같은 분석적 장점에도 불구하고, 스크래치 시험을 통한 접합력 측정 방법은 아직까진 산업적으로 널리 활용되지 못하고 있다. 따라서, 본 연구에서는 스크래치 테스트의 원리 및 이론에 대하여 간략히 알아보고, 스크래치 분석을 이용한 접합력 비교에 대한 실제 사례들을 소개하고자 하였다.

  • PDF

Effect of Ion-beam Pre-treatment on the Interfacial Adhesion of Sputter-deposited Cu film on FR-4 Substrate (이온빔 전처리가 스퍼터 증착된 Cu 박막과 FR-4 기판 사이의 계면접착력에 미치는 영향)

  • Min, Kyoung-Jin;Park, Sung-Cheol;Lee, Ki-Wook;Kim, Jae-Dong;Kim, Do-Geun;Lee, Gun-Hwan;Park, Young-Bae
    • Korean Journal of Metals and Materials
    • /
    • v.47 no.1
    • /
    • pp.26-31
    • /
    • 2009
  • The effects of $Ar/O_2$ ion-beam pre-treatment conditions on the interfacial adhesion energy of sputterdeposited Cu thin film to FR-4 substrate were systematically investigated in order to understand the interfacial bonding mechanism for practical application to advanced chip-in-substrate package systems. Measured peel strength increases from $45.8{\pm}5.7g/mm$ to $61.3{\pm}2.4g/mm$ by $Ar/O_2$ ion-beam pre-treatment with anode voltage of 64 V. Interfacial bonding mechanism between sputter-deposited Cu film and FR-4 substrate seems to be dominated by chemical bonding effect rather than mechanical interlocking effect. It is found that chemical bonding intensity between carbon and oxygen at FR-4 surface increases due to $Ar/O_2$ ion-beam pretreatment, which seems to be related to the strong adhesion energy between sputter-deposited Cu film and FR-4 substrate.

Leather's Environment-friendly Adhesion Surface Treatment of shoe's material by Plasma (플라즈마를 이용한 신발소재의 환경 친화적인 접착 표면 처리(I))

  • Ha, Soon-Hee;Jang, U-Jin;Seul, Soo-Duk
    • Journal of Adhesion and Interface
    • /
    • v.6 no.2
    • /
    • pp.6-12
    • /
    • 2005
  • The plasma generally, ionized gas state, is the 4th material state composed the universe. Generating the plasma artificially has been studied by spending energy and it has a lot of applications in human's life. There are several merits to modify the surface of polymer using plasma. Above all, plasma maintains the property of polymer because of it changes the property of surface only. Also, it doesn't use a organic solvent and it is the environment friendship because of there are no waste under processing. Furthemore, in case of high-pressure plasma, it is possible that automated-processing continuously. In this study, we tried the reforming of surface to rise the adhesive strength between the material of polymer, experimented the rising of adhesive strength through a experiment of peel strength by virtue of processing time and using gas, confirmed the change of polymer's surface through measuring the surface contact angle analyzer and scanning electron microscopy (SEM).

  • PDF

Study on a New ACF Bonding Methods in LCD Module Using a High Power Diode Laser (다이오드레이저를 이용한 디스플레이 모듈 내 이방성 전도 필름(ACF) 접합 기술에 관한 연구)

  • Ryu K. H.;Seon M. H.;Nam G. J.;Kwak N. H.
    • Laser Solutions
    • /
    • v.8 no.3
    • /
    • pp.21-26
    • /
    • 2005
  • A bonding process between tape-carrier package and a glass panel with anisotropic conductive film (ACF) has been investigated by making use of high power diode laser as a heat source for cure. The results from modeling of process and from optical properties of layers showed that heat absorbed from polyimide film surface and ACF layer is dominant source of curing during laser illumination. Laser ACF bonding has better bonding quality than conventional bonding in view of peel strength, flatness, pressure unbalance and processing time. New ACF bonding processes by making use of high power diode laser are proposed.

  • PDF

Study on the Self Diagnosis of Reinforced Concrete Beam Retrofitted by Composite Materials with Optical Fiber Sensors (광섬유 센서를 이용한 복합재료로 보수보강된 철근콘크리트 보의 자기진단 기법개발)

  • 김기수;신영수;김종우;전재홍;조윤범
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2001.10a
    • /
    • pp.57-60
    • /
    • 2001
  • In order to extend the life time of building and civil infra-structure, nowadays, patch type fibrous composite materials are widely used. Retrofitted concrete columns and beams gain the stiffness and strength, but they lose toughness and show brittle failure. Usually, the cracks of concrete structures are visible with naked eyes and the status of the structure in the life cycle is estimated with visible inspection. After retrofitting of the structure, crack visibility is blocked by retrofitted composite materials. Therefore, structural monitoring after retrofitting is indispensible and self diagnosis method with optical fiber sensor is very useful. In this paper, We try to detect peel out effect and find the strain difference between main structure and retrofitting patch material when they separate each other.

  • PDF

A study on the surface roughness of ED copper foil by changing the treatment process (전해동박 후처리 공정변화가 미치는 표면조도 변화에 관한 연구)

  • 조차제;김상겸;김정익
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2003.03a
    • /
    • pp.23-23
    • /
    • 2003
  • PCB 회로기판용 전해동박은 드럼형태의 음극 표면에 연속적으로 전기 도금한 후 벗겨내어 권취하는 원박 제조공정과 접착성, 내열성, 내화학성, 방청성을 부여하기 위한 후처리 공정으로 나눈다. 이 후처리 공정 중 동박과 수지와의 접착성을 부여하기 위해 일반적으로 전기도금을 통해 조화(Nodule)처리를 실시하는데, 최근 LCD, PDP 등의 평판 디스플레이 장치의 구동칩이 실장되는 TCP용 동박의 경우 2$\mu\textrm{m}$이하의 낮은 조도(Rz)와 함께 높은 접착강도(Peel Strength)가 요구되고 있다. 그러나, Reel to Reel 형태의 연속도금공정으로 진행되는 조화처리에 있어 일반 비이커 실험결과는 실제 양산공정과의 재현성에 있어서 상당한 제한성이 노출된 바 있다. 이에 본 연구에서는 Reel to Reel 형태의 연속도금공정을 모사 할 수 있는 실험장치를 설계, 제작하여 동박표면의 노듈형성에 있어 주요인자를 정량적으로 분석하였다.

  • PDF

Adhesive Properties of Emulsion PSA Polymerized Using Tween Series Nonionic Surfactants (Tween계 비이온 계면활성제를 이용하여 중합한 에멀션점착제의 접착물성)

  • Lim, Tae Kyun;Lee, Myung Cheon
    • Korean Chemical Engineering Research
    • /
    • v.52 no.3
    • /
    • pp.289-293
    • /
    • 2014
  • In making emulsion type pressure sensitive adhesive (PSA), environmentally friendly Tween series nonionic surfactants were used to find out the possibility of substituting the traditional nonyl-phenyl nonionic surfactant (NP-40) by comparing their adhesive properties. Results exhibited that the PSA used Tween series nonionic surfactants showed much better adhesive properties in peel strength and holding power than that used NP-40.

Study on the Monitoring Method of Concrete Structure Repaired by Carbon Sheets with Optical Fiber Sensors (콘크리트구조물의 탄소섬유시트에 의한 구조 보강시 광섬유 센서를 이용한 모니터링기법에 관한 연구)

  • Kim, Ki-Soo
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2005.11a
    • /
    • pp.149-152
    • /
    • 2005
  • In order to extend the life time of building and civil infra-structure, nowadays, patch type carbon sheets are widely used as repairing meterials. Repaired concrete columns and beams with carbon sheets gain their stiffness and strength, but they lose toughness and show brittle failure behaviors. Usually, the cracks of concrete structures are visible with naked eyes and the status of the structure in the life cycle is estimated with visible inspection. After repairing of the structure, crack visibility is blocked by repaired carbon sheets. Therefore, structural monitoring after repairing is indispensible and self diagnosis method with optical fiber sensor is very useful. In this paper, peel-out effects is detected with optical fiber sensors and the strain difference between main structure and repaired carbon sheets when they separate each other.

  • PDF