• 제목/요약/키워드: Pedicle morphology

검색결과 5건 처리시간 0.023초

Comparison of Morphological Characteristics of the Subaxial Cervical Spine between Athetoid Cerebral Palsy and Normal Control

  • Kim, Jun Young;Kwon, Jae Yeol;Kim, Moon Seok;Lee, Jeong Jae;Kim, Il Sup;Hong, Jae Taek
    • Journal of Korean Neurosurgical Society
    • /
    • 제61권2호
    • /
    • pp.243-250
    • /
    • 2018
  • Objective : To compare the morphometry of subaxial cervical spine between cerebral palsy (CP) and normal control. Methods : We retrospectively analyzed 72 patients with CP, as well as 72 patients from normal population. The two groups were matched for age, sex, and body mass index. Pedicle, lateral mass (LM), and vertebral foramen were evaluated using computed tomography (CT) imaging. Pedicle diameter, LM height, thickness, width and vertebral foramen asymmetry (VFA) were measured and compared between the two groups. Cervical dynamic motion, disc and facet joint degeneration were investigated. Additionally, we compared the morphology of LM between convex side and concave side with cervical scoliotic CP patients. Results : LM height was smaller in CP group. LM thickness and width were larger in CP group at mid-cervical level. In 40 CP patients with cervical scoliosis, there were no height and width differences between convex and concave side. Pedicle outer diameter was not statistically different between two groups. Pedicle inner diameter was significantly smaller in CP group. Pedicle sclerosis was more frequent in CP patients. VFA was larger in CP group at C3, C4, and C5. Disc/facet degeneration grade was higher in the CP group. Cervical motion of CP group was smaller than those of the control group. Conclusion : LM morphology of CP patients was different from normal population. Sclerotic pedicles and vertebral foramen asymmetry were more commonly identified in CP patients. CP patients were more likely to demonstrate progressive disc/facet degeneration. This data may provide useful information on cervical posterior instrumentation in CP patients.

Pedicular and Extrapedicular Morphometric Analysis in the Korean Population : Computed Tomographic Assessment Relevance to Pedicle and Extrapedicle Screw Fixation in the Thoracic Spine

  • Kim, Jun-Hak;Choi, Gyeong-Mi;Chang, In-Bok;Ahn, Sung-Ki;Song, Joon-Ho;Choi, Hyun-Chul
    • Journal of Korean Neurosurgical Society
    • /
    • 제46권3호
    • /
    • pp.181-188
    • /
    • 2009
  • Objective : To evaluate the anatomical parameters that must be considered when performing thoracic transpedicular or extrapedicular screw fixation. Methods : We selected 958 vertebrae (1,916 pedicles) from 98 patients for analysis. Eight parameters were measured from CT scans : the transverse outer pedicular diameter, transverse inner pedicular diameter, length, angle, chord length of the pedicles and the transverse width, angle, and chord length of the pedicle-rib units. Results : The age of the patients ranged from 21 to 82 years (mean: 48.2 years) and there were 57 men and 41 women. The narrowest transverse outer pedicular diameter was at T5 (4.4 mm). The narrowest pedicle length was at T1 (15.9 mm). For pedicle angle, T1 was 31.6 degrees, which was the most convergent angle, and it showed the tendency of the lower the level, the lesser the convergent angle. The chord length showed a horizontal pattern with similar values at all levels. For the PRU width, T5 showed a similar pattern to the pedicle width at 13.4 mm. For the PRU angle, T1 was the largest angle at 46.2 degrees and the tendency was the lower the level. the narrower the angle. For chord length, T1 was the shortest at 46.9 mm and T8 was the longest at 60.1 mm. Conclusion : When transpedicular screw fixations carried out at the mid-thoracic level, special care must be taken because there is a high chance of danger of medial wall violation. In these circumstances, extrapedicular screw fixation may be considered as an alternative treatment.

TiN 및 DLC 코팅된 척추용 나사못 시스템 Rod의 기계적 특성 분석 (Mechanical Properties of TiN and DLC coated Rod for Pedicle Screw System)

  • 강관수;정태곤;양재웅;우수헌;박태현;정용훈
    • 한국표면공학회지
    • /
    • 제50권3호
    • /
    • pp.183-191
    • /
    • 2017
  • In this study, surface morphology and mechanical property of TiN and DLC coated pedicle screw have been investigated by field-emission scanning electron microscopy, energy dispersive X-ray spectroscopy, X-ray diffraction, vickers hardness test, axial gripping, and axial torsional gripping capacity test. From the EDS and XRD results, the composition and crystal structure of TiN and DLC coated surface were verified. The hardness value was increased by TIN and DLC coating, and the DLC coating surface has the highest value. The gripping capacity also showed higher value for TiN and DLC coated specimen than that of non-coated (Ti alloy) surface. The surface morphology of gripping tested specimen showed rougher scratched surface from Ti alloy than TiN and DLC coated layer.

TiN 및 DLC 코팅된 척추경나사못시스템 수술기구의 기계적 안정성 분석 (Mechanical Stability of TiN and DLC Coated Instrument of Pedicle Screw System)

  • 강관수;정태곤;양재웅;우수헌;박태현;정용훈
    • 한국표면공학회지
    • /
    • 제52권3호
    • /
    • pp.163-170
    • /
    • 2019
  • Durability of instrument is one of the most important factor to ensure accurate treatment and decrease failure for the orthopedic surgical operation. Normally, a set-screw driver tip has been processed with hard coating for their higher durability and wear resistance. And several surface modification methods were obtained such as titanium nitride (TiN) coating, diamond like carbon coating, other nitriding, and etc. In this study, we have surface modified on set-screw driver tip with TiN and DLC, investigated whether the TiN and DLC coatings affect the mechanical properties and durability of the set-screw driver tip in the pedicle screw system. The surface morphologies were observed with scanning-electron microscopy (SEM), and the static/dynamic torsional properties were investigated with universal testing machine based on ASTM F543. Coating thickness of each coatings were commonly around $1^{\circ}C$. Static torsional stiffness, and ultimate torque values for DLC and TiN coated samples were significantly higher than those of non-coated sample by the pared T-test. Surface morphology of after the dynamic torsional test was more clean with less scratch or friction traces from DLC coating than that of TiN coating and non-coated sample.

Inverted C-V 피판을 이용한 반흔 배꼽의 재건 치험례 (Reconstruction of Scarred Umbilicus Using an Inverted C-V Flap: A Case Report)

  • 홍윤기;조종제
    • Archives of Plastic Surgery
    • /
    • 제34권5호
    • /
    • pp.653-655
    • /
    • 2007
  • Purpose: The umbilicus is an important aesthetic component of the abdomen. Its absence is both cosmetically and psychologically distressing to the patient. Umbilical reconstruction should always be aimed at creating an umbilicus of sufficient depth and good morphology with less scarring. The C-V flap developed for nipple reconstruction was used in an inverted fashion in case of umbilical reconstruction. The aim of this article is to report our experience of scarred umbilical reconstruction using inverted C-V flap. Methods: A 22-year-old woman presented with contracted scar tissue in the umbilical region because she had undergone surgical correction of an umbilical hernia at 5 year of age. Pedicle of the inverted C-V flap was based cephalically. For enhancing depth of the umbilicus, three anchoring sutures to linea alba were done at both lateral and caudal aspects of the umbilical tube. Primary closures were done at donor sites of the V flaps and bolster sutures were done in the caudal direction of the inverted umbilical tube. Results: The patient was satisfied with the appearance of umbilicus. Major complications such as dehiscence, infection, and delayed healing did not occur. Conclusion: The inverted C-V flap is easy and simple technique, and it can produce a satisfactory reconstruction of umbilical structure.