• Title/Summary/Keyword: Peak-cut

Search Result 198, Processing Time 0.029 seconds

Study on Interior Noise Transfer Path Analysis by Tire Cavity Resonance (타이어 공동의 공명에 의한 차량 실내음 전달경로 연구)

  • Lee, Sang-Ju;Kang, Byun-Seok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11b
    • /
    • pp.129-133
    • /
    • 2005
  • Vibration transmitted through rolling tire is a major source of road noise in vehicle interior noise on the range of low frequency.($0{\sim}500Hz$) Among various road noises, tire cavity noise has very peak on $200{\sim}250Hz$. And generally it is generated by cavity resonance of tire. In this paper, tire cut-sample is used to calculate the tire cavity frequency. Cavity resonance frequency of tire is measured through vertical/tangential forces at load cell of axle using drum cleat impact. This method is useful to find cavity peak because measured forces do not have complex peaks. And changing the test conditions (air inflation, loads), tire cavity resonance characteristics are identified. Finally, vehicle interior noise is measured as tire/vehicle are changing. As difference of tire vertical force is bigger, interior noise level is higher at cavity frequency. Also we can assume that vehicle sensitivity is important factor at tire cavity noise.

  • PDF

A Study on the Design and Control Characteristics for Optimum Operation of the PV System-based ESS (PV System 기반 ESS의 최적운전을 위한 설계 및 제어 특성에 관한 연구)

  • Cha, Insu;Park, Jongbok;Jung, Gyeonghwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.5
    • /
    • pp.19-30
    • /
    • 2016
  • In this study, realize voltage regulation $220Vac{\pm}10%$ or less, frequency fluctuation $60Hz{\pm}1%$ or less over the independent operation and grid-connected operation technologies for power stabilization relates to the ESS designed and manufactured in conjunction with solar installations and solar to compensate the output reduction due to the polarization of the solar module through the polarization prevention technology for preventing the optical module efficiency is lowered, in conjunction with the BMS inverter efficiency was more than 92%, more than 90% of the charging efficiency to the target. This study was designed in conjunction with the ESS solar power plants, grid-connected operation and independent operation, Peak-Cut, it can stabilize the grid via the Peak-Shifting operation

Reactive Silencer Design for Suppressing Impulse Noise from a High Voltage Cut Out Switch Fuse (고전압 COS 퓨즈로부터 방사된 충격성 소음 저감용 반사형 소음기의 설계)

  • Song, Hwa-Young;Kim, Deok-Han;Lee, Jong-Suk;Lee, Dong-Hoon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.951-954
    • /
    • 2006
  • This Study introduces the design of a reactive type silencer for reducing impulse noises emitted from a high voltage COS fuse of a transformer. When a high voltage COS fuse becomes a short circuit by the over current, the peak sound pressure level above 150dB(A) is generated at the distance of 2m from a COS Fuse. For the purpose of the reduction of impulse noise, in this study. the reactive type silencers have been utilized. The performance of noise reduction for them can be expressed by insertion loss. The reactive silencers have been tested for 23 different types with each different porosity, hole diameter and depth. From the experimental results, it is found that the reactive silencer has an excellent performance to greatly suppress the impulse noise. The one-stage, two-stage and three-stage reactive type silencers have been shown to have the insertion losses of about from 35dB (A) to 25dB(A).

  • PDF

Effect of Assist Gas on Laser Induced Plasma and Bead Formation in Welding of Structural Steel by CW Nd:YAG Laser (철강재료 용접에서 보조가스가 레이저플라즈마와 용입특성에 미치는 영향)

  • 김기철;신현준
    • Journal of Welding and Joining
    • /
    • v.20 no.3
    • /
    • pp.109-115
    • /
    • 2002
  • In this study high power Nd:YAG laser welding of structural steel was investigated. For the test steel blocks of $50{\times}50{\times}200mm$ were cut and machined, and bead-on-plate weld was made on the machined surface. Argon, nitrogen, helium, dry air or mixed gases were used to find the effect of shielding conditions on the bead formation. Results demonstrated that there were Fe I rich region and Fe II rich region in the laser induced plasma column based on the spectral analysis with S-2000 field spectrometer The Fe I region was located at the root of the column near keyhole opening. On the other hand, Fe II region was found at the middle of the plasma column. In the Nd:YAG laser welding, Fe I region emitted continuum which had peak value at wave length of around 710nm, and Fe II region had the peak at 580nm. In the welding of steel by $CO_2$ laser, however, no continuum was observed. There showed two groups of strong spikes in the $CO_2$ laser welding; the first group was displayed at the wave band of 450-560nm. This spike group emitted stronger intensity of light and sharper peaks than those group at 680-800nm.

An Experimental Study on the Propagation Characteristics and Reduction of Impulse Noises from a High Voltage COS Fuse (고전압 COS 퓨즈로부터 방사된 충격성 소음의 전파특성과 저감에 관한 실험적 연구)

  • Song, Hwa-Young;Ju, Kyung-Min;Lee, Dong-Hoon;Kang, Rae-Goog;Jung, Nak-Hun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.71-74
    • /
    • 2005
  • This experimental study describes the propagation characteristics and reduction of impulse noises emitted from a high voltage COS(Cut Out Switch) fuse of a transformer. When a high voltage COS fuse becomes a short circuit by the over current. The peak sound Pressure above 150dB(A) is generated. In this study, an impulse noise generator is designed for generating the impulse noises similar to the noise level of COS fuse, which is utilized to test the noise reduction of a reactive silencer. The reactive silencers have been tested for 10 different types with each different porosity, hole diameter and length. From the experimental results, it is found that the reactive silencer has an excellent performance to greatly suppress the impulse noise and that its performance is closely connected with the porosity and hole diameter.

  • PDF

Impact of the Gain-saturation Characteristic of Erbium-doped Fiber Amplifiers on Suppression of Atmospheric-turbulence-induced Optical Scintillation in a Terrestrial Free-space Optical Communication System

  • Jeong, Yoo Seok;Kim, Chul Han
    • Current Optics and Photonics
    • /
    • v.5 no.2
    • /
    • pp.141-146
    • /
    • 2021
  • We have evaluated the suppression effect of atmospheric-turbulence-induced optical scintillation in terrestrial free-space optical (FSO) communication systems using a gain-saturated erbium-doped fiber amplifier (EDFA). The variation of EDFA output signal power has been measured with different amounts of gain saturation and modulation indices of the optical input signal. From the measured results, we have found that the peak-to-peak power variation was decreased drastically below 2 kHz of modulation frequency, in both 3-dB and 6-dB gain compression cases. Then, the power spectral density (PSD) of optical scintillation has been calculated with Butterworth-type transfer function. In the calculation, different levels of atmospheric-turbulence-induced optical scintillation have been taken into account with different values of the Butterworth cut-off frequency. Finally, the suppression effect of optical scintillation has been estimated with the measured frequency response of the EDFA and the calculated PSD of the optical scintillation. From our estimated results, the atmospheric-turbulence-induced optical scintillation could be suppressed efficiently, as long as the EDFA were operated in a deeply gain-saturated region.

Replacing C3S cement with PP fibre and nanobiosilica in stabilisation of organic clays

  • Soheil Ghadr;Arya Assadi-Langroudi;Hadi Bahadori
    • Geomechanics and Engineering
    • /
    • v.33 no.4
    • /
    • pp.401-414
    • /
    • 2023
  • Organic clays are ideal habitat for flora and fauna. From a geotechnical perspective, organic clays are soft, weak, variable, heterogeneous and flocculated. Portland cement is a universally common stabiliser. However, some organic acids in soil inhibit full hydration and expose cementation products to rapid dissolution. This paper investigates scopes for use of C3S cement to enable durable cementation. Prospects of using PP fibre alongside with C3S cement, scopes for partial replacement of C3S cement with a plant-based nanosilica and evolution of binders are then investigated. Binding mixtures here mimic the natural functions of rhizoliths, amorphous phases, and calcites. Testing sample population include natural and fibre-reinforced clays, compact mixes of clay - C3S cement, clay - nanobiosilica, and clay, C3S cement and nanobiosilica. Benefits and constraints of C3S cement and fibres for retaining the naturally flocculated structure of organic clays are discussed. Nanobiosilica provides an opportunity to cut the C3S content, and to transition of highly compressive organic clays into an engineered, open-structured medium with >0.5 MPa compressive strength across the strains spanning from peak to 1.5-times peak.

LOCAL ANOMALIES AROUND THE THIRD PEAK IN THE CMB ANGULAR POWER SPECTRUM OF WMAP 7-YEAR DATA

  • Ko, Kyeong Yeon;Park, Chan-Gyung;Hwang, Jai-Chan
    • Journal of The Korean Astronomical Society
    • /
    • v.46 no.2
    • /
    • pp.75-91
    • /
    • 2013
  • We estimate the power spectra of the cosmic microwave background radiation (CMB) temperature anisotropy in localized regions of the sky using the Wilkinson Microwave Anisotropy Probe (WMAP) 7-year data. We find that the north and south hat regions at high Galactic latitude ($|b|{\geq}30^{\circ}C$) show an anomaly in the power spectrum amplitude around the third peak, which is statistically significant up to 3. We try to explain the cause of the observed anomaly by analyzing the low Galactic latitude ($|b|$ < $30^{\circ}C$) regions where the galaxy contamination is expected to be stronger, and the regions weakly or strongly dominated byWMAP instrument noise. We also consider the possible effect of unresolved radio point sources. We find another but less statistically significant anomaly in the low Galactic latitude north and south regions whose behavior is opposite to the one at high latitude. Our analysis shows that the observed north-south anomaly at high latitude becomes weaker on regions with high number of observations (weak instrument noise), suggesting that the anomaly is significant at sky regions that are dominated by the WMAP instrument noise. We have checked that the observed north-south anomaly has weak dependences on the bin-width used in the power spectrum estimation, and on the Galactic latitude cut. We also discuss the possibility that the detected anomaly may hinge on the particular choice of the multipole bin around the third peak. We anticipate that the issue of whether or not the anomaly is intrinsic one or due to WMAP instrument noise will be resolved by the forthcoming Planck data.

Changes in Moisture Content and Quality of Oriental Hybrid Lily (Lilium oriental cv. Siberia) Cut Flowers during Storage at Cold and Dry Condition and Subsequent Exposure to Ambient Temperature (오리엔탈 나리 '시베리아' 절화의 포장내 건식저장 기간별 수분함량과 품질 변화)

  • Lee, Jung-Soo;Rhee, JuHee;Kang, Yun-Im;Choi, Ji Weon
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.23 no.1
    • /
    • pp.27-36
    • /
    • 2017
  • In order to determine the relationship between water content and flower qualities of oriental hybrid lily cv. 'Siberia' cut flower, flowers were subjected to dry and cold storage at $5^{\circ}C$ for 3, 6, and 12 days and subsequently exposed to ambient temperature ($26^{\circ}C$) in bottles with water for up to 16 days. Flowers stored at $22^{\circ}C$ in dry condition for 3 days were used as the control. Changes in fresh weight, moisture content, water balance, flowering stages, osmolality and vase life of cut flowers were observed. Flowers treated with cold and dry storage had higher moisture content compared to control sample. However, this trend was evident only for 3-day cold and dry stored sample during the whole storage period. The fresh weight of cut flowers increased gradually when the samples were transferred to ambient temperature in water bottles and then declined steadily before reaching the peak in between 6-8 days of vase life. However, the changes of fresh weight of control sample were substantially faster than samples pre-treated with cold and dry storage. This was also correlated with the water balance of cut flower as it reached the minus (-) value in 6-8 days of vase life at ambient temperature. Cut lily flowers showed high osmolality values corresponding with the duration of dry storage regardless of low or higher temperature. However, osmolality had no effect on vase life since flower stem absorbed water rapidly at the end of dry storage period. Our vase life results suggest that cold and dry storage of lily cut flowers for a certain period could ensure longer vase life at ambient temperature. It was observed that prolonging the storage period at cold and dry condition for more than a week significantly increased bud abortion, reduced longevity of flowers and reduced the vase life of cut flowers. On the other hand, the shorter cold and dry storage treatment delayed the bud opening and senescence of the flowers, thus, slowering the normal maturation and aging. Results indicated that dry and cold storage at $5^{\circ}C$ for 3 days was effective in maintaining and preserving overall quality and vase life at ambient condition of oriental hybrid lily cut flowers.

A Study on external and internal morphology and pattern analysis in 4 kinds of Mok-Hyaeng Radix (4종류 목향류(木香類)의 외부(外部) 및 내부형태(內部形態)와 이화학패턴연구)

  • Kim, Hong-Jun;Kang, Kyoung-Sik;Choi, Go-Ya;Kim, Ho-Kyung;Jeong, Seung-Il;Ju, Young-Sung
    • Korean Journal of Oriental Medicine
    • /
    • v.12 no.3 s.18
    • /
    • pp.117-130
    • /
    • 2006
  • The purpose of this study was to introduce the differential standard of Mok-Hyaeng Radix species. We established the classificatory standard according to the external and internal morphology and the pattern in 4 kinds of Mok-Hyaeng Radix. The results follow: 1. On the external morphology, Radix of Vladimiria souliei had a sticky material in the head of roots and it was yellowish white in the cut surface. It attached to teeth during chewing. Radix of Aucklandia lappa (=Saussurea lappa) was dark grayish brown and was grayish brown in the cut surface. It had special odor and was not attache to teeth chewing it. On the other hand, Radix of Inula helenium was dark brown. In the cut surface, cortical layer was different from wood layer. Radix of Aristolochia contorta was yellowish brown. In the cut surface, it was not smooth and cortical layer was different from wood layer. 2. On the internal morphology, Radix of Vladimiria souliei had many fascicular fibers and scattered large oil chambers in the bast ray, xylem ray, and parenchyma. On Radix of Aucklandia lappa (=Saussurea lappa), it was difficult to find out the trace when the cork layer was exfoliated. The cambium formed circle and the large oil chambers were scattered in the phloem and xylem. On the other hand, external cortical layer of Radix of Inula helenium was detached and cambium was formed to indistinct circle and large oil chambers were scattered in the phloem and xylem. On Radix of Arustolochia contorta, the large oil chambers were scattered in the surface later, bast part was relatively broad and cambium formed circle. 3. On the TLC pattern, Radix of Aristolochia contorta, Inula helenium, Aucklandia lappa, and Vladimiria souliei were chromogenic to violet and purple according to sulfuric acid colour pattern, especially faint on Aristolochia contorta. 4. On the pattern analysis of HPLC, we compared the content and the pattern of constunolide and dehydrocostus lactone, Radix of Aucklandia lappa was similar to Radix of Vladimiria souliei and Radix of Aristolochia contorta was similar to Radix of Inula helenium. On the total HPLC component pattern, constunolide and dehydrocostus lactone were similar in all four types, but it showed the Rf 5-6 peak was only in Radix of Aristolochia contorta, not in Radix of Inula helenium, Aucklandia lappa, and Vladimiria souliei. It is considered the results of this study will be furnished the basis to succeeding studies and it is needed to extensive comparative study for the same genus-degree of relatedness.

  • PDF