• Title/Summary/Keyword: Peak-cut

Search Result 195, Processing Time 0.028 seconds

Quantitative estimation of the energy ux during an explosive chromospheric evaporation in a white light are kernel observed by Hinode, IRIS, SDO, and RHESSI

  • Lee, Kyoung-Sun;Imada, Shinsuke;Watanabe, Kyoko;Bamba, Yumi;Brooks, David H.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.2
    • /
    • pp.67.3-68
    • /
    • 2016
  • An X1.6 flare occurred in AR 12192 on 2014 October 22 around 14:06 UT and was observed by Hinode, IRIS, SDO and RHESSI. We analyze a bright kernel which produces a white light flare (WLF) with continuum enhancement and a hard X-ray (HXR) peak. Taking advantage of the spectroscopic observations of IRIS and EIS, we measure the temporal variation of the plasma properties in the bright kernel in the chromosphere and corona. We found that explosive evaporation was observed when the WLF occurred, even though the intensity enhancement in hotter lines is quite weak. The temporal correlation of the WLF, HXR peak, and evaporation flows indicates that the WLF was produced by accelerated electrons. To understand the white light emission processes, we calculated the deposited energy flux from the non-thermal electrons observed by RHESSI and compared it to the dissipated energy estimated from the chromospheric lines (Mg II triplet) observed by IRIS. The deposited energy flux from the non-thermal electrons is about $3.1{\times}10^{10}erg\;cm^{-2}s^{-1}$ when we assume a cut-off energy of 20 keV. The estimated energy flux from the temperature changes in the chromosphere measured from the Mg II subordinate line is about $4.6-6.7{\times}10^9erg\;cm^{-2}s^{-1}$, 15 - 22 % of the deposited energy. By comparison of these estimated energy fluxes we conclude that the continuum enhancement was directly produced by the non-thermal electrons.

  • PDF

Reduced Computation Using the DFT Property in the Phase Weighting Method (위상 조절 방법에서 DFT 특성을 이용한 계산량 저감)

  • Ryu Heung-Gyoon;Hieu Nguyen Thanh
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.10 s.101
    • /
    • pp.1028-1035
    • /
    • 2005
  • OFDM system has high PAPR(Peak-to-Average-Power Ratio) problem. In this paper, we present a low complexity phase weighting method to reduce the computational quantity so that we can cut down the processing time of SPW method. Proposed method is derived from the DFT property of periodical sequences by which PAPR can be reduced efficiently. The simulation results show the same PAPR reduction efficiency of proposed method in comparison with conventional methods. It can reduce 2.15 dB of PAPR with two phase factors and 3.95 dB of PAPR with four phase factors. The computation analysis shows significant improvement in the low complexity phase weighting method.

Mater-Slave Type Two DC-DC Converters Paralldl Operation Using a Single Current Sensor (단일 전류센서를 사용한 마스터-슬레이브 전류 분배형 2개의 DC-DC 컨버터 병렬운전)

  • 손승찬;박상은;정민재;성세진
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.2
    • /
    • pp.184-191
    • /
    • 2000
  • We discussed load CUlTent sharing for Master/Slave convertedMSC) type two DC-DC Converters parallel operation using a single current sensor method. In the conventional method, two CTs have been used to share t the load CUlTent equally with two coηverters‘ This paper presents a novel load CUlTent distribution method u using a single CUlTent sensor that can share load CUlTent effectively with only one CT in the Master-Slave C conveη:ers(MSCs) type. To confirm parallel operational performance of proposed DC-DC converters parallel operation, two experimental prototype converters were designed, implemented and experimented under three a arbitrary conditions. A load cur‘rent shahring perforrnance of the proposed method was compared with that of a c conventional peak CUt${\gamma}$ent method requmng two CTs. Those experimental results show that load cUlTent s sharing performance of paralleled two converters using a single CUlTent sensor was good and operated as well a as conventional method (ex, Pe밟 CUlTent Method)

  • PDF

An Analysis on Effects of Passive Heating of Low Energy House Using Heat in Greenhouse (온실의 열을 이용한 저에너지하우스의 패시브 난방 효과 분석)

  • Yoo, Dong-Wan;Lee, Tae-Goo
    • KIEAE Journal
    • /
    • v.16 no.5
    • /
    • pp.103-109
    • /
    • 2016
  • Purpose: In Korea, to reduce greenhouse gas emissions, energy performance standard of buildings is being reinforced with goals of Passive House until 2017 and Zero Energy House until 2025 in order to reduce emissions from buildings which constitute a quarter of greenhouse gas emissions. In order to achieve the target of Zero Energy House, it is certainly necessary to develop renewable energy that can replace cooling and heating energy occupying a significant amount of building energy consumption after increasing the energy performance firstly. Method: In this study, effects of heat in greenhouse heated by solar heating on indoor heating were analyzed by constructing a greenhouse in front of the Low Energy Building. Result: As a result, indoor temperature was increased by peak average $27.8^{\circ}C$, peak average $6.8^{\circ}C$ was increased from when heat in greenhouse has not been used for heating and indoor surface temperature was increased by average $5.1^{\circ}C$. It shows it can be possible to use heat in greenhouse for heating, if the heating effects can be same as this experimental result because Energy Saving-Type buildings such as Low Energy House or Passive House keep from 18 to $20^{\circ}C$ in winter. Therefore, even if energy supply is cut off by disasters and other reasons, cooling and heating can be possible for some time.

A Study on the FIR Digital Filter using Modified Window Function (변형된 창함수를 사용한 FIR 디지털 필터에 관한 연구)

  • 강경덕;배상범;김남호;류지구
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.4 no.1
    • /
    • pp.49-55
    • /
    • 2003
  • The use of digital filters in the signal process field is increasing rapidly with development of the modern industrial society. Especially, detail processors, Y/C separators, ghost removing filters, standard converters (NTSC to PAL or PAL to NTSC) and noise reducers, all of which use digital filters, tend to be used in digital video and audio processing, CATV and various communication fields. Generally, there are two different digital filters, the Rf (infinite impulse response) filter and the FIR (finite impulse response) filter in digital filter. In this paper, we have designed FIR filter which has the phase linearity and the easiness of creation. In the design of the FIR digital filter, the window function is used to alleviate the ripples caused by Gibbs Phenomenon around the cut off frequency of the band pass. But there're some problems to choose proper window function for the design destination due to its fixed values. Therefore, in this paper, we designed a modified Hanning window with new parameter which is adaptively chosen corresponding to design objectives. The digital filter was simulated to prove the validity of the model and it was compared with the Hamming, the Manning, the Blacknan and the Kaiser window function. And we have used peak side-lobe and transient characteristics as standard of judgement.

  • PDF

FPCB Cutting Process using ns and ps Laser (나노초 및 피코초 레이저를 이용한 FPCB의 절단특성 분석)

  • Shin, Dong-Sig;Lee, Jae-Hoon;Sohn, Hyon-Kee;Paik, Byoung-Man
    • Laser Solutions
    • /
    • v.11 no.4
    • /
    • pp.29-34
    • /
    • 2008
  • Ultraviolet laser micromachining has increasingly been applied to the electronics industry where precision machining of high-density, multi-layer, and multi material components is in a strong demand. Due to the ever-decreasing size of electronic products such as cellular phones, MP3 players, digital cameras, etc., flexible printed circuit board (FPCB), multi-layered with polymers and metals, tends to be thicker. In present, multi-layered FPCBs are being mechanically cut with a punching die. The mechanical cutting of FPCBs causes such defects as burr on layer edges, cracks in terminals, delamination and chipping of layers. In this study, the laser cutting mechanism of FPCB was examined to solve problems related to surface debris and short-circuiting that can be caused by the photo-thermal effect. The laser cutting of PI and FCCL, which are base materials of FPCB, was carried out using a pico-second laser(355nm, 532nm) and nano-second UV laser with adjusting variables such as the average/peak power, scanning speed, cycles, gas and materials. Points which special attention should be paid are that a fast scanning speed, low repetition rate and high peak power are required for precision machining.

  • PDF

Surface Characteristics of Anodized Ti-3wt%, 20wt%, and 40wt%Nb Alloys

  • Ko, Y.M.;Choe, H.C.;Jang, S.H.;Kim, T.H.
    • Corrosion Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.143-147
    • /
    • 2009
  • In biomedical implants and dental fields, titanium has been widely utilized for excellent corrosion resistance and biocompatibility. However, Ti and its alloys are nonbioactive after being implanted in bone. In this study, for the purpose of improvement in biocompatibility the anodic $TiO_2$ layer on Ti-xNb alloys were fabricated by electrochemical method in phosphate solution, and the effect of Nb content on the pore size, the morphology and crystallinity of Ti oxide layer formed by the anodic oxidation method was investigated. The Ti containing Nb up to 3 wt%, 20 wt% and 40 wt% were melted by using a vacuum furnace. The sample were cut, polished, and homogenized for 24 hr at $1050^{\circ}C$ for surface roughness test and anodizing. Titanium anodic layer was formed on the specimen surface in an electrolytic solution of 1 M phosphoric acid at constant current densities ($30mA/cm^2$) by anodizing method. Microstructural morphology, crystallinity, composition, and surface roughness of oxide layer were observed by FE-SEM, XRD, EDS, and roughness tester, respectively. The structure of alloy was changed from $\alpha$-phase to $\beta$-phase with increase of Nb content. From XRD results, the structure of $TiO_2$ formed on the Ti-xNb surface was anatase, and no peaks of $Nb_2O_5$ or other Nb oxide were detected suggesting that Nb atoms are dispersed in $TiO_2$-based solid solution. Surface roughness test and SEM results, pore size formed on surface and surface roughness decreased as Nb content increased. From the line analysis results, intensity of Ti peak was high in the center of pore, whereas, intensity of O peak was high in the outside of pore center.

Evaluation of temperature effects on brake wear particles using clustered heatmaps

  • Shin, Jihoon;Yim, Inhyeok;Kwon, Soon-Bark;Park, Sechan;Kim, Min-soo;Cha, YoonKyung
    • Environmental Engineering Research
    • /
    • v.24 no.4
    • /
    • pp.680-689
    • /
    • 2019
  • Temperature effects on the generation of brake wear particles from railway vehicles were generated, with a particular focus on the generation of ultrafine particles. A real scale brake dynamometer test was repeated five times under low and high initial temperatures of brake discs, respectively, to obtain generalized results. Size distributions and temporal patterns of wear particles were analyzed through visualization using clustered heatmaps. Our results indicate that high initial temperature conditions promote the generation of ultrafine particles. While particle concentration peaked within the range of fine sized particles under both low and high initial temperature, an additional peak occurred within the range of ultrafine sized particles only under high initial temperature. The timing of peak occurrence also differed between low and high initial temperature conditions. Under low initial temperature fine sized particles were generated intensively at the latter end of braking, whereas under high initial temperature both fine and ultrafine particles were generated more dispersedly along the braking period. The clustered correlation heatmap divided particle sizes into two groups, within which generation timing and concentration of particles were similar. The cut-off point between the two groups was approximately 100 nm, confirming that the governing mechanisms for the generation of fine particles and ultrafine particles are different.

A Study on Typical Rates of Water-use for Primary School, Middle School and High School Facilities (초.중.고등학교 시설의 급수 사용량에 대한 연구)

  • Kim, Kyu-Saeng
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.12
    • /
    • pp.802-807
    • /
    • 2008
  • A Study on Typical Rates of Water-use for School Facilities has been carried out in this work. Water supply system is given much weight in school facilities. Therefore, it set up a basis efficiency using of water sources to calculate typical rates of water use. The results are summarized as follows; 1) On the whole, typical rates of water-use was founded out 15 L/stu. d in pirmary school, 10 L/stu. d in middle school and 30 L/stu. d in high school smaller than the existing it. It was rate of water-use change as season and Max. Rates of water-use was July. 2) I deem that school hours are 5 hour's in primary school, 7 hour's in middle school and 8 hour's in high school. It the concept of 1 hour that is lesson time 40 minutes and resting time 10 minutes in primary school, lesson time 45 minutes and resting time 10 minutes in middle school and lesson time 50 minutes and resting time 10 minutes in high school. 3) It is desired that we calculate the volume of pump and water tank throughout this concept and the size of water tank should be 1.5 times with taking peak load into consideration by this study on typical rate of water-use. 4) The amount of using water increases in gradually and I consider the life cycle of facilities is more than 10 years. As a result, I can forecast that the size will be insufficiency but I deem that if we devise a plan about parallel pumping on water tank space, we can cope with it. Also, it is expected that we can cut back the transport energy by controlling pump volume.

Frequency analysis of the tonic vibration reflex of the hand flexor muscles

  • 박희석
    • Proceedings of the ESK Conference
    • /
    • 1994.04a
    • /
    • pp.49-51
    • /
    • 1994
  • The aims of this study were first to determine the influence of vibration displacement amplitude $(200{\mu}m, 300{\mu}m peak-to-peak)$ at selected frequencies (40-200Hz) on a commonly observed but often undesired motor response elicited bylocal vibratory stimulation, the Tonic Vibration Reflex (TVR). Second, to determine the degree of synchronization of motor unit (MU) activity with vibratory stimuli. Vibration was applied to the distal tendons of the hand flexor muscles. Changes in root- mean-square electromyographic (EMG) activity of the finger and wrist flexor muscles were analyzed both as a function of their initial contraction level (0%, 10%, 20% of the maximal voluntarycontraction: MVC) and as a function of the vibration parameters. The results indicate that the TVR increased with the initial muscle contraction up to 10% MVC: The TVR increased with vibration frequency up to 100-150 Hz and decreases beyond; A significant increase of the TVR with vibration displacement amplitude was observed only for the wrist flexor muscle; MU synchronization at vibration frequency (VF) was found more often in the low frequency range $(f{\leq}100 Hz)$ and tended todecrease beyond; In the high frequency range $(f{\geq}120 Hz)$, MU activity at subharmonic frequency was predominant; The "cut-off" frequency of the synchronization with VF was neither affected by the vibration displacement amplitude nor initial muscle contraction level. The surface EMG turned out to be a useful means to analyze MU synchronization since it is noninvasive, and it can be easily used for analysis of different muscle contraction levels, while single MU technique might have some difficulties at high muscle contraction levels. Furthermore, these results indicate that high frequencyvibration (f>150 Hz) tends to induce less muscle/tendon stress and MU synchronization. Such remarks are of importance for the design of hand-held vibrating tools.ing tools.

  • PDF