• Title/Summary/Keyword: Peak-cut

Search Result 195, Processing Time 0.022 seconds

Evaluation of Drop/Impact Performance of Laptop Computer (컴퓨터의 충격해석 및 실험적 검증)

  • Youn, Youg-Han;Rim, Kyung-Hwa;Kim, Jin-Kyoo;An, Chae-Hun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.737-741
    • /
    • 2000
  • Portable communication devices such as laptop computers suffer impact-induced failure in their usage. Drop/impact performance of these products is one of important concerns of product design. Because of the small size of this kind of electronics products, it is very expensive, time-consuming and difficult to conduct drop tests to directly detect the failure mechanism and identify their drop behaviors. Finite element analysis provides a vital, powerful vehicle to solve the problems. The models are created with HYPERMESH, and the analysis is carried out with LS-DYNA3D. The analysis is focused on HDD impact behavior in acceleration peak values.

  • PDF

Isolation and Partial Physicochemical Characterization of Bile Acid-Binding Fraction from Rice Bran Protein Hydrolysates (미강 단백질 가수분해물에서 담즙산 결합 획분의 분리 및 특성구명)

  • Cho, Wan-Il;Moon, Tae-Wha
    • Korean Journal of Food Science and Technology
    • /
    • v.29 no.3
    • /
    • pp.417-426
    • /
    • 1997
  • Rice bran protein hydrolysates were prepared and some of their physicochemical properties were investigated to utilize rice bran as starting material for functional food ingredient. Rice bran proteins (RBP) were prepared from defatted rice bran by alkaline extraction and isoelectric precipitation. The enzyme for hydrolysis of RBP was selected through measuring relative activity by pH-drop method and comparing the degree of hydrolysis (DH) of hydrolysates. The enzymatic hydrolysates prepared by $Esperase^{\circledR}$ treatment were partitioned into two fractions by ultrafiltration(UF) with a 10 kDa molecular weight cut-off membrane. Each fraction was applied to a cholic acid-conjugated ${\omega}-aminohexyl$ Sepharose 4B column and the bile acid-binding components were obtained by eluting with deoxycholate. Gel permeation chromatography on a Sephadex G-50 column revealed that molecular weight of the bile acid-binding fraction of UF permeate was distributed in ranges of $2\;kDa{\sim}10\;kDa$ and $0.2\;kDa{\sim}0.6\;kDa$. Three peaks (R-1, R-2 and R-3) were obtained by prep-HPLC of bile acid-binding fraction of UF retentate and analyzed for total and free amino acid composition. The results showed that proline content of the bile-acid binding polypeptides and peptides was four times as much as that of rice bran protein and that the peak corresponding to higher average hydrophobicity had a higher free amino acid content. Average hydrophobicity slightly increased with enzymatic hydrolysis.

  • PDF

AN ELECTROCHEMICAL STUDY BY USING A POTENTIOSTAT ON THE CORROSION OF AMALGAMS IN SALIVA (Potentiostat를 이용한 타액에서의 아말감부식에 대한 전기화학적 연구)

  • Son, Yoon-Hee;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.19 no.2
    • /
    • pp.534-548
    • /
    • 1994
  • The purpose of this study is to observe the corrosion characteristics of seven dental amalgams (CAULK FINE CUT, CAULK SPHERICAL, OPTALLOY II, DISPERSALLOY, HI VERALOY, TYTIN, VALIANT) through the anodic polarization curve obtained by using a potentiostat. After each amalgam alloy and Hg being triturated, the triturated mass was inserted into the cylindrical metal mold, and condensed by hydrolic pressure(160 kg/$cm^2$). Each specimen was removed from the metal mold. 24 hours after condensation, specimens were polished with the emery paper and stored at room temperature for 1 week. The anodic polarization curves were employed to compare the corrosion behaviours of the amalgam in 0.9% saline solution, Fusayama's artificial saliva, and stimulated parotid saliva at $37^{\circ}C$ with 3-electrode potentiostat. After the immersion of specimen in electrolyte for 1 hour, the potential scan was begun. The potential scan range was. -1700m V ~ + 400m V(vs. S. C. E) in the working electrode and the scan rate was 50m V /sec. The results were as follows, 1. The corrosion potential, the potential of anodic current peak, and transpassive potential in the stimulated parotid saliva shifted to more anodic direction than those in saline solution, and the current density in the stimulated parotid saliva was lower than that in saline solution. Those in Fusayama's artificial saliva was similar to those in stimulated parotid saliva. 2. The anodic polarization profiles in Fusayama's artificial saliva and stimulated parotid saliva indicated a region of slow slope current density, which is extending from the corrosion potential to the potential of anodic current peak, but that in 0.9% saline solution indicated no region of slow slope. 3. The corrosion potentials for CAULK FINE CUT, CAULK SPHERICAL, and OPT ALLOY II had the similarity in 0.9% saline solution, Fusayama's artificial saliva and stimulated parotid saliva, but those for high coper amalgam and VALIANT had no similarity. 4. The current density for TYTIN amalgam in stimulated parotid saliva was the lowest among the others. 5. As for current density, there was no significant difference between palladium enriched VALINAT and other high copper amalgams.

  • PDF

Antibacterial Activity of Zein Hydrolysate with Pepsin (Pepsin에 의한 Zein 가수분해물의 항균활성)

  • Kang, Yoon-Jung;Yi, Sang-Duk;Lee, Gyu-Hee;Oh, Man-Jin
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.35 no.2
    • /
    • pp.127-131
    • /
    • 2006
  • A study was carried out to produce antimicrobial peptides from zein treated with pretenses of six kinds. Among the pretenses of six kinds, zein hydrolysate treated with pepsin showed the highest antimicrobial activity. The zein hydrolysate with pepsin was fractionated with membrane filter (30,000 10,000 and 3,000 molecular weight cut-off) and antimicrobial activity was measured for each fractions. Antimicrobial activity appeared greatly in the fraction below 3,000 (molecular weight cut-off) . The fraction was re-fractionated by HPLC and substances of two peaks collected as a sample to measure antimicrobial activity. All of both peaks showed the antimicrobial activity but 1st peak exhibited a consistently higher antimicrobial activity than 2nd peak. Minimum inhibitory concentrations (MIC) were between 2.5 and 3.0 mg/mL. The peptide was heat-stable since antimicrobial activity was maintained after treated with heat for 20 min at $121^{\circ}C$. N-terminal amino acid sequence of peptide fractionated by HPLC was leucine, glutamic acid, proline, phenylalanine, aspartic acid and argenine. These results indicated that peptide isolated from zein hydrosate with pepsin can use as a natural preservative ingredient in food industry.

AN ELECTROCHEMICAL STUDY ON THE CORROSION BEHAVIOUR OF AMALGAMS IN THE SALINE SOLUTIONS WITH FLUORIDE COMPOUNDS (불소화합물을 첨가한 생리식염수에서 아말감의 부식거동에 관한 전기화학적 연구)

  • Yun, Chong-Hun;Kwon, Hyuk-Choon;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.1
    • /
    • pp.396-412
    • /
    • 1997
  • The purpose of this study is to observe the corrosion characteristics of five dental amalgams(CAULK FINE CUT, OPTALLOY II, DISPERSALLOY, TYTIN, and VALIANT) in the solutions with fluoride compound through the anodic polarization curve obtained by using a potentiostat. After each amalgam alloy and Hg being triturated, the triturated mass was inserted into the cylindrical metal mold, and condensed by hydraulic pressure(160 kg/$cm^2$). Each specimen was removed from the metal mold. Specimens were polished with the silicone carbide grinding paper 24 hours after condensation and stored at room temperature for 1 week. The anodic polarization curves were employed to compare the corrosion behaviours of the amalgams in 0.9 % saline solution and in the saline solutions with 2.2 ppm, 0.05 %, 2 % NaF, and 8 % $SnF_2$ at $37^{\circ}C$ with 3-electrode potentiostat. After the immersion of specimen in electrolyte for 30 minutes, the potential scan was begun. The potential scan range was -1500m V to + 800m V(vs. S.C.E.) in the working electrode and the scan rate was 50 mV/sec. The results were as follows, 1. The corrosion potential, the potential of anodic current peak, and transpassive potential in the saline solutions with NaF shifted to lower direction than those in normal saline solution, and the current density in the saline solutions with NaF was higher than that in normal saline solution. The differences were increased as the concentrations of NaF became higher. 2. The corrosion potential and transpassive potential in the saline solution with $SnF_2$ shifted to higher direction than those in normal saline solution, and the current density in the saline solution with $SnF_2$ was higher than that in normal saline solution after the corrosion potential. The anodic polarization curves in the saline solution with $SnF_2$ had no outstanding anodic current peak. 3. The corrosion potentials for high-copper amalgams were much higher than those for CAULK FINE CUT and OPTALLOY II in normal saline solution, but, as the concentrations of fluoride compound became higher, the differences in corrosion potentials between them were decreased. The corrosion potentials had the similarity in the saline solution with 2% NaF or 8% $SnF_2$. 4. The current density for TYTIN was the lowest among the others in normal saline solution and in the saline solution with 2.2 ppm or 0.05 % NaF. 5. There was no significant difference in current density between Pd-enriched VALIANT and other high-copper amalgams.

  • PDF

Study on the Emergency Assessment about Seismic Safety of Cable-supported Bridges using the Comparison of Displacement due to Earthquake with Disaster Management Criteria (변위 비교를 통한 케이블지지교량의 긴급 지진 안전성 평가 방법의 고찰)

  • Park, Sung-Woo;Lee, Seung Han
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.6
    • /
    • pp.114-122
    • /
    • 2018
  • This study presents the emergency assessment method about seismic safety of cable-supported bridges using seismic acceleration sensors installed on the primary structural elements of them. The structural models of bridges are updated iteratively to make their dynamic characteristics to be similar to those of real bridges based on the comparison of their natural frequencies with those of real bridges estimated from acceleration data measured at ordinary times by the seismic acceleration sensor. The displacement at the location of each seismic acceleration sensor is derived by seismic analysis using design earthquake, and the peak value of them is determined as the disaster management criteria in advance. The displacement time history is calculated by the double integration of the acceleration time history which is recorded at each seismic acceleration sensor and filtered by high cut(low pass) and low cut(high pass) filters. Finally, the seismic safety is evaluated by the comparison of the peak value in calculated displacement time history with the disaster management criteria determined in advance. The applicability of proposed methodology is verified by performing the seismic safety assessment of 12 cable-supported bridges using the acceleration data recorded during Gyeongju earthquake.

Growth and flowering as affected by tuber hardness, GA3 concentrations and treatment duration in Calla (Zantedeschia)

  • Nam, Chun-Woo;Yoo, Dong-Lim;Kim, Su-Jeong;Suh, Jong-Teak;Peak, Kee Yoeup;An, Se Woong;Chun, Hee
    • Korean Journal of Agricultural Science
    • /
    • v.43 no.1
    • /
    • pp.28-32
    • /
    • 2016
  • This experiment was carried out to determine optimal culture conditions for the production of cut flowers and tubers of Calla (Zantedeschia 'Black Magic') in highlands. To achieve the research purpose, growth of 'Black Magic' Calla influenced by tuber hardness (3.3 and $6.0kg/cm^2$), $GA_3$ concentration (0, 100 and $200mgL^{-1}$), duration of $GA_3$ treatment (24 hr, 12 hr and 30min before planting) were investigated. When tubers have high hardness, those were not severely injured by soft rot disease regardless of $GA_3$ concentrations and treatment durations. Tubers with low tuber hardness showed more than 90% of soft rot occurrence when treated with $200mgL^{-1}$ $GA_3$ for 24 hrs before planting. However, soft rot did not occur when tubers were treated with $200mgL^{-1}$ $GA_3$ for 12 hrs before planting. In conclusion, $GA_3$ treatment results showed soft rot occurrence statistically significant degree in accordance with the bulbs hardness. In addition, the yield of the cut flowers is the result received the greatest effect in accordance with the bulbs in size and appeared to not be determined in accordance with the $GA_3$ treatment concentration and hardness bulbs. To obtain flowers without soft rot symptom, tubers (as $6.0kg/cm^2$) should be completely dried after $GA_3$ treatment.

A New PAPR Reduction Method Using the Multiphase Complementary Codes in the OFDM Communication System (복수 위상 상보 부호 쌍에 의한 OFDM통신 시스템의 새로운 PAPR 감소 기법)

  • Kang Byoung-Moo;Kim Sang-Woo;Ryu Heung-Gyoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.7 s.98
    • /
    • pp.690-696
    • /
    • 2005
  • It is very important to reduce the PAPR(Peak to Average Power Ratio) in the OFDM(Orthogonal Frequency Division Multiplexing) communication system. The proposed method in this paper is an effective PAPR reduction method using the Golay complementary codes without my side information. There are some PAPR reduction methods with the complementary code pairs or sequences. They are usually a type of the forward ewer correction codes so that they produce more redundancies and lower down the code rate. Because of this, the information rate may be cut down or more bandwidth must be required. In this paper, we propose a PAPR reduction method that uses the multi-phase complementary code f3r converting the 4-QAM into 16-QAM constellation. It does not change the code rate and does not require the side information.

Development of Operation Scenarios by HILS for the Energy Storage System Operated with Renewable Energy Source (HILS를 이용한 신재생 에너지원이 포함된 에너지 저장시스템의 운영 시나리오 개발)

  • Shin, Dong-Cheol;Jeon, Jee-Hwan;Park, Sung-Jin;Lee, Dong-Myung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.2
    • /
    • pp.224-232
    • /
    • 2018
  • According to government policy, renewable energy facility such as solar power generation is being implemented for newly constructed buildings. In recent years, the introduction of Energy Storage System (ESS) served as an emergency power for replacing an existing diesel generator has been increasing. Furthermore, in order to expand the efficacy of the ESS operation, operation in combination with renewable energy sources such as solar and wind power generation is increasing. Hence, development of the ESS operation algorithms for emergency mode as well as the peak power cut mode, which is the essential feature of ESS, are necessary. The operational scenarios of ESS need to consider load power requirement and the amount of the power generation by renewable energy sources. For the verification of the developed scenarios, tests under the actual situation are demanded, but there is a difficulty in simulating the emergency operation situation such as system failure in the actual site. Therefore, this paper proposes simulation models for the HILS(Hardware In the Loop Simulation) and operation modes developed through HILS for the ESS operated with renewable energy source under peak power reduction and emergency modes. The paper shows that the ESS operation scenarios developed through HILS work properly at the actual site, and it verifies the effectiveness of the control logic developed by the HILS.

Visible photochromic energy shift of $WO_{3}$/CdS thin films fabricated by thermal evaporation method (진공증착 법으로 제작한 $WO_{3}$/CdS 박막의 가시광 광 변색의 에너지 전환)

  • Kim, Keun-Mook;Kim, Myung-Wook
    • Journal of the Semiconductor & Display Technology
    • /
    • v.4 no.1 s.10
    • /
    • pp.29-34
    • /
    • 2005
  • Tungsten oxide($WO_{3}$) is suitable to materials for photochromic window in the visible region. The resistivities of CdS, $WO_{3}$, and $WO_{3}$/CdS films prepared by thermal evaporation method were $4.61\times 10\^{3}$, $7.59\times10^{3}$, and $6.29\times10^{3}$ $\omega$ cm. And x-ray diffraction patterns of CdS, $WO_{3}$/CdS films showed a preferred orientation of hexagonal(002), and the monoclinic(020) structure, respectively. The optical transmission were measured that the cut-on wavelength were 510nm, 380nm for CdS and $WO_{3}$ films respectively, and the transmission spectrum of $WO_{3}$/CdS was shifted into the visible region. Photoluminescence(PL) spectra showed the two peaks at 2.8 eV and 3.2 eV for the as-grown sample($WO_{3}$/CdS ($500{\AA}$), but the other sample($WO_{3}$/CdS ($1000{\AA}$)) had a peak energy value of 2.8 eV. The photochromism of $WO_{3}$/CdS films showed that the excitation of electron-hole pairs and subsequent coloration is shifted into visible-light range. And the spectral behavior of coloration turned out to be proportional to the excited electron-hole pairs creation rate of CdS film. This result is interpreted in terms of charge carrier injection from the CdS-layer into the $WO_{3}$ films. We found a value of about 2.8 eV of $WO_{3}$/CdS film which is somewhat higher than peak energy of 2.54 eV using CBD prepared by Bechinger et. al.

  • PDF