• Title/Summary/Keyword: Peak torque

Search Result 260, Processing Time 0.03 seconds

The Effect of Dynamic Lumbar Stabilization Exercise to Be Affected with Improvement and Maintenance of Trunk Stability after Opened Microscopic Laser Discectomy (개방형 현미경적 요추간판 제거술 후 동적 요부 안정화 운동에 따른 체간 안정성의 개선과 유지)

  • Nam, Kun-Woo;Kim, Jong-Soon
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.11 no.1
    • /
    • pp.37-48
    • /
    • 2005
  • Objects: This study is designed to analysis improvement and maintaince of trunk stability targeting patients who need post operative rehabilitation exercise after undergoing opened microscopic laser discectomy(OMLD) due to HNP. Method: Between March 2004 and February 2005 a total sixty patients who underwent OMLD due to $L_4/L_5$, $L_5/S_1$ HNP and who agreed to the experiment were subject for this study. Experimental group consisted of 18 subjects, and they underwent 45 minutes dynamic lumbar stabilization exercise And control group consisted of 18 subjects who conducted conservative physical therapy based on the use of physical modality for 45 minutes except to exercise. Results: Experimental group that was lumbar extensor's isometric peak torque, weight distribution of both leg, trunk muscle balance and Oswestry LBP disability index increased during 12 weeks in a statistically significant manner compared to before exercise (p<.05). When re-test was tried, isometric peak torque (p>.05) and Oswestry LBP disability index(p<.05) maintained 12th week level or improved. Weight distribution rate of both leg and trunk muscle balance maintained the level of 8th week of exercise execution(p<.05). Control group that was lumbar extensor's isometric peak torque, weight distribution rate of both leg and trunk muscle balance aggravated during 12 weeks compared to pre-test(p>.05) But, Oswestry LBP disability index increased in a statistically significant level compared to pre-test(p<.05). When re-test was tried, isometric peak torque increased slightly compared to pre-test, but decreased when at least $60^{\circ}$ flexion angle(p>.05). Weight distribution rate of both leg and trunk muscle balance also aggravated compared to pre-test(p>.05), and Oswestry LBP disability index was similar to the 4th week of physical therapy execution(p>.05). Conclusion: Successive postoperative Especially, Application of dynamic lumbar stabilization exercise program is important than traditional lumbar strengthening exercise program in the maintaince of spinal stability.

  • PDF

Correlation between Isokinetic Parameters of Knee Joint and Lower Extremity Function (무릎관절의 등속성 변수와 하지 기능의 상관관계)

  • Lee, Se-yun;Park, Jong-hyun;Jeon, Jeongwoo;Hong, Jiheon;Yu, Jaeho;Kim, Jinseop;Lee, Dongyeop
    • Journal of Advanced Technology Convergence
    • /
    • v.1 no.1
    • /
    • pp.33-42
    • /
    • 2022
  • The flexors and extensors of the knee joint are essential for maintaining body stability. The purpose of this study was to investigate the correlation between the isokinetic parameters of the knee flexor and extensor muscles and the function of the lower extremity muscles. Twenty-two healthy adults participated in this study. The time to peak torque (TTP), acceleration time (AT), and peak torque (PT) of the knee flexor and extensor muscles were measured. A 20m sprint, Sargent jump, one leg hop test, and side shuffle were measured to evaluate lower extremity function. The correlation between each variable was analyzed using Pearson correlation coefficient. PT of the knee flexor showed a significant correlation with single leg hops and 6M hops in a single leg. PT of knee extensors was found to be significantly correlated with Sargent jumps and triple hops. Based on the results of this study, we suggest that the strength of the knee flexor and extensor muscles has the potential to be used to predict lower extremity function.

Dynamics Modeling and Control of a Delta High-speed Parallel Robot (Delta 고속 병렬로봇의 동역학 모델링 및 제어)

  • Kim, Han Sung
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.13 no.5
    • /
    • pp.90-97
    • /
    • 2014
  • This paper presents a simplified dynamics model, dynamics simulations, and computed torque control experiments of the Delta high-speed parallel robot. Using the typical Newton-Euler method, a simplified but accurate dynamics model with practical assumptions is derived. Accuracy and fast calculations of the dynamics are essential in the computed torque control for high-speed applications. It was found that the simplified dynamics equation is in very god agreement with the ADAMS model, and the calculation time of the inverse kinematics and inverse dynamics is about 0.04 msec. From the dynamics simulations, the cycle trajectory along the y-axis requires less peak motor torque and a lower angular velocity and less power than that along the x-axis. The computed torque control scheme can reduce the position error by half as compared to a PD control scheme. Finally, the developed Delta parallel robot prototype, half the size of the ABB Flexpicker robot, can achieve a cycle time of 0.43 sec with a 1.0kg payload.

High Power Factor Low Torque Ripple Drive Scheme of Single-Phase SRM based on Mathematical Model (수학적 모델을 기반으로 한 단상 SRM의 고역률 저토크리플 구동방식)

  • Liang, Jianing;Kim, Tae-Hyoung;Lee, Dong-Hee;Ahn, Jin-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2007.04c
    • /
    • pp.103-106
    • /
    • 2007
  • This paper presents single-phase SRM drive system with single-stage high power factor and low torque ripple. Single-phase SRM has simple mechanical and electrical structure, robust and high speed operation characteristic. But conventional SRM drive with diode bridge rectifier and filter capacitor has a low power factor because of short charge time of capacitor. Therefore, this paper presents a novel single-phase SRM drive with single-stage structure circuit, which can improve the power factor and reduce peak torque ripple. A novel switching topology is presented base on mathematical analysis. The novel drive method is verified by simulations and experiments.

  • PDF

A study of the inductance measurement of an interior permanent magnet synchronous motor (매입형 영구자석 동기전동기의 인덕턴스 계측에 관한 연구)

  • Lee, Jeong-Hum;Kim, Young-Seok;Joung, Woo-Taik;Kim, Dai-Hyun;Choi, Yang-Kwang
    • Proceedings of the KIEE Conference
    • /
    • 2004.10a
    • /
    • pp.18-20
    • /
    • 2004
  • An interior permanent magnet synchronous motor (IPMSM) is receiving increased attention for many industrial applications because of its high torque to inertia ratio, superior power density, and high efficiency. IPMSM is necessary to use the accurate information of the inductace for the precise torque control owing to the reluctance torque. This paper presents two method to measure the each-axis inductance. The first method uses the peak current that is measured by applying the pulsewise voltage on the each position of IPMSM. The second uses the hysteresis loop of the flux and current measured by applying the positive and negative pulsewise voltage alternately on the each-axis.

  • PDF

Inductance Measurement Method of an IPMSM (매입형 영구자석 동기전동기의 인덕턴스 계측)

  • Lee, Jeong-Hum;Choi, Chang-Ho;Kim, Young-Seok;Kim, Min-Kyu;Wang, Hyo-Jin;Kim, Yun-Hyun
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.11-13
    • /
    • 2005
  • An interior permanent magnet synchronous motor (IPMSM) is receiving increased attention for many industrial applications because of its high torque to inertia ratio, superior power density, and high efficiency. IPMSM is necessary to use the accurate information of the inductance for the precise torque control owing to the reluctance torque. This paper presents two method to measure the each-axis Inductance. The first method uses the peak current that is measured by applying the pulsewise voltage on the each position of IPMSM. The second uses the hysteresis loop of the flux and current measured by applying the positive and negative pulsewise voltage alternately on the each-axis.

  • PDF

The Study of Isokinetic Exercise Test of Trunk Rotation of 20's Male College Students (20대 남자대학생의 몸통회전에 대한 등속성운동 검사에 관한 연구)

  • Choi, Byung-Ok
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.12 no.2
    • /
    • pp.21-25
    • /
    • 2006
  • Objective: The purposes of this study are to provide fundamental data and a rehabilitation program in physical therapy. It has been operated by 30 male college students for lumbar isokinetic exercises. Method : Subjects have been carried out in an experiment by Biodex system operating isokinetic torso rotation. This performance was activated by left rotation after right rotation repeatedly. Results: 1. The mean peak torques at $60^{\circ}$/sec were $95.6{\pm}20.62$ (Rt) and $93.84{\pm}18.41$ (Lt). 2. The mean peak torques/body weight at $60^{\circ}$/sec were $69.28{\pm}28.31$ (Rt) and $67.07{\pm}27.04$ (Lt). 3. The total works in right side at $60^{\circ}$/sec and $180^{\circ}$/sec were $492.21{\pm}92.37$, $1294.97{\pm}278.96$ and in left side at $60^{\circ}$/sec and $180^{\circ}$/sec were $515.78{\pm}109.47$, $1443.74{\pm}329.67$. 4. The work to body weight ratio at $60^{\circ}$/sec was $78.30{\pm}32.37$ (Rt) and $79.93{\pm}37.30$ (Lt). 5. The average powers in right side at $60^{\circ}$/sec and $180^{\circ}$/sec were $76.75{\pm}16.69$, $117.19{\pm}29.94$ and in left side at $60^{\circ}$/sec and $180^{\circ}$/sec were $78.54{\pm}18.58$, $125.39{\pm}32.90$. 6. The work fatigue at $180^{\circ}$/sec was $21.76{\pm}14.82$ (Rt) and $19.66{\pm}26.23$ (Lt). Conclusion: In right side and left side, there was no significant difference in peak torque. peak torque/body weight, work to body-weight ratio, average power of trunk rotators at $60^{\circ}$/sec(p<0.05). However there was a significant difference in the total work of trunk rotators at $60^{\circ}$/sec(p>0.05). Also there was a significant difference in the average of trunk rotators at $180^{\circ}$/sec(p>0.05).

  • PDF

Modified Single-Phase SRM Drive for Low Torque Ripple and Power Factor Improvement (저토크리플 및 역률개선을 위한 수정된 단상 SRM 구동시스템)

  • An, Young-Joo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.8
    • /
    • pp.975-982
    • /
    • 2007
  • The single-phase switched reluctance motor(SRM) drive requires DC source which is generally supplied through a rectifier connected with a commercial source. The rectifier is consist of a diode full bridge and a filter circuit. Usually the filter circuit uses capacitor with large value capacitance to reduce ripple component of DC power. Although the peak torque ripple of SRM is small, the short charge and discharge current of the filter capacitor draws the low power factor and system efficiency. A modified single phase SRM drive system is presented in this paper, which includes drive circuit realizing reduction of torque ripple and improvement of power factor. In the proposed drive circuit, one switching part and diode which can separate the output of AC/DC rectifier from the filter capacitor is added. Also, a upper switch of drive circuit is exchanged a diode in order to reduce power switching device. Therefore the number of power switch device is not changed, two diodes are only added in the SRM drive. To verify the proposed system, some simulation and experimental results are presented.

Review of characteristics of the isotonic combination: Importance of eccentric training (등장성 수축 결합기법의 특성에 대한 고찰 - 원심성 훈련의 중요성 -)

  • Kim, Mi-hyun;Bae, Sung-soo
    • PNF and Movement
    • /
    • v.2 no.1
    • /
    • pp.25-33
    • /
    • 2004
  • Purpose : The purpose of this article is to summarize the characteristics of isotonic combination. Method : Some studies of the motor unit activation patterns during isometric, concentric, and eccentric actions, neural strategies in the control of muscle force, and concentric versus combined concentric-eccentric training were reviewed. Results & Conclusions : Eccentric torque may be relatively higher than concentric torque for two potential reasons: 1) stretch responses in the antagonist are not elicited to restrain the motion as can occur concentrically and 2) stretch responses in the agonist may augment eccentric torque production. Concentric-eccentric training has a greater influence on functional capacity than that of concentric training. Both maximal force and average force throughout the motion were significantly higher when the dynamic action was started with preactivation as compared to the mode without preactivation. The peak torques observed during the concentric phase of the eccentric-concentric muscle actions were higher than those noted in the pure concentric contraction.

  • PDF

Isokinetic Evaluation of Plantarflexors with Knee Position (슬관절의 자세에 따른 족관절 저측굴곡근의 등속성 근력 평가)

  • Bae Sung-Soo;Lee Hyun-Ok;Lee Keun-Heui
    • The Journal of Korean Physical Therapy
    • /
    • v.12 no.2
    • /
    • pp.145-152
    • /
    • 2000
  • Pcak torque. angle of peak torque occurrence. total work, average power. endurance of the ankle plantar flexors were studied with the knee positioned $0^{\circ}\;and\;90^{\circ}$ flexion. Plantar flexors of 20 students were tested on Cybex 6000 dynamometer. The results were as fallows ; 1. The peak torque values were significantly higher with knee extension than knee $90^{\circ}$ flexion. 2. The angle of peak torque occurrence were earlier with knee extension than knee $90^{\circ}$ flexion, but no significant. 3. The total work were significantly higher with knee extension than knee $90^{\circ}$ flexion. at$30^{\circ}/sec$, but no significant at $90^{\circ}/sec$ 4. The endurance ratio were higher significantly with knee $90^{\circ}$ flex ion than knee extension 5. The mean average power were significantly higher with knee extension than knee $90^{\circ}$ flextion

  • PDF