• Title/Summary/Keyword: Peak time

Search Result 4,659, Processing Time 0.035 seconds

Maximal Oxygen Debt, Lactate and Excess Lactate in Men with Low Hematocrit Ratio (헤마토크?????? 비율이 낮은 사람에 있어서 최대 산소 부채와 과잉젖산 사이의 관계)

  • Kim, Dai-Sung;Nam, Kee-Yong
    • The Korean Journal of Physiology
    • /
    • v.2 no.2
    • /
    • pp.53-61
    • /
    • 1968
  • Maximal oxygen debt, lactate and excess lactate were measured in 13 men with low hematocrit ratio before and after maximal exercise. Maximal exercise run was performed on a treadmill and the duration of run was 2 minutes 45 seconds in each subject. Hematocrit ratio ranged between 35 and 47%, the mean being 39.8%. The following results were obtained. 1. Maximal oxygen debt expressed on basis of body weight increased as the hematocrit ratio decreased. The correlation coefficient between the two was r= -0.770. 2. The time necessary for decreasing to 50% of total maximal $O_2$ debt(half time) became longer as the hematocrit ratio decreased. In normal men the half time was about 4 minutes and at the longest it was 12 minutes in men with the lowest hematocrit ratio. 3. The lactate concentration reached its peak value after 3 minutes of recovery. Thereafter, the time course of decrease in lactate concentration coincided roughly with that of respiratory oxygen debt curve. To reach to the resting level, however, it took longer time than that of respiratory oxygen debt. 4. Resting concentrations of lactate was 1.28 mM/l, pyruvate 0.13 mM/l and L/P ratio was 9.8. Peak value of ${\Delta}L$ after exercise reached to the value of 10.4 mM/l and ${\Delta}L/P$ reached 26.0. Peak excess lactate after exercise was 6.34 mM/l. 5. The part of oxygen debt accounted for by the oxygen equivalent of excess lactate was only 38.4%. A better relationship between lactate and oxygen debt was observed and the part of oxygen debt accounted for by the oxygen equivalent of lactate was 63.3%. 6. Peak value of lactate after maximal exercise increased as the hematocrit ratio decreased. 7. Respiratory oxygen debt of 100 ml/kg was accounted for by lactate more than 60% and only 30% was by excess lactate. 8. Excess lactate was not a good index of respiratory oxygen debt.

  • PDF

Evaluation of Combustion Gas for Carbon Oxide of Wood Coated with Bis-(dialkylaminoalkyl) Phosphinic Acids Additives

  • Jin, Eui;Chung, Yeong-Jin
    • Fire Science and Engineering
    • /
    • v.30 no.4
    • /
    • pp.65-72
    • /
    • 2016
  • This study examined the generation of combustion toxic gases of pinus rigida specimens processed with bis-(dimethylaminomethyl) phosphinic acid (DMDAP), bis-(diethylaminomethyl) phosphinic acid (DEDAP), and bis-(dibutylaminomethyl) phosphinic acid (DBDAP). Each pinus rigida plate was coated three times with 15 wt.% flame retardants in an aqueous solution. The specimens were then dried at room temperature. The production of combustion toxic gases was investigated using a cone calorimeter (ISO 5660-1). The first time to peak mass loss rate ($1^{st}-TMLR_{peak}$) processed with the chemical additives decreased to 5.9 from 41.2% compared with the unprocessed specimen. The second time to the peak mass loss rate ($2^{nd}-TMLR_{peak}$) for the processed specimens was decreased 1.8% for DMDAP and 5.3% for DBDAP and increased 1.8% for DEDAP. The peak carbon monoxide ($CO_{peak}$) production was 1.5 to 2.0 times higher than that of the unprocessed plate. The peak carbon dioxide ($CO_{2peak}$) production was reduced 0.01 times for DMDAP and increased 1.15 to 1.19 times for DEDAP and DBDAP compared with the unprocessed specimens. In particular, the oxygen concentration was much higher than 15%, which can be fatal to humans and the resulting hazard can be eliminated. Overall, the combustion toxicity of flammable gas were increased partially by the chemical additives compared with those of the unprocessed plate.

The Analysis of Load Management Effect in Shor-Term Generation Expansion Planning (단기 전력우급계획에서의 부하관리 효과 분석연구)

  • 김준현;정도영
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.41 no.9
    • /
    • pp.994-1002
    • /
    • 1992
  • With regard to price elasticity and cross elasticity of electricity, optimal generation expansion planning method including load management effect is suggested. In addition, optimal peak time price can be determined simultaneously, and we adopt peak time tariff as load management strategy. Instead of using hourly marginal demand curves where we can get customer surplus, we used chronological load curve with constraints to preserve social welfare. This method is proved useful in short-term generation expansion planning.

  • PDF

Analysis and Experiment of Peak Current Controlled Buck LED Driver

  • Kim, Marn-Go;Jung, Young-Seok
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.68-69
    • /
    • 2011
  • Realistic amounts of time delay are found to have significant effects on the average output LED current and on the critical inductor value at the boundary between the two conduction modes. Especially, the time delay can provide an accurate LED current for the peak current controlled (PCC) buck converter with a wide input voltage. Experimental results are presented for the PCC buck LED driver with constant-frequency controller.

  • PDF

Characteristics in W-EDM of Tungsten Carbide (초경합금의 와이어 방전가공에 의한 특성)

  • 맹민재
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.4
    • /
    • pp.7-13
    • /
    • 2001
  • Wire electrical discharge machining experiments in conducted to investigate characteristics of acoustic emission (AE) and electrical discharge energy due to current peak (I$_{p}$), pulse on time($\tau$/on/). The AE signals are obtained with a sensor attached to workpiece side. Machining states are identified with scanning electron microscopy and residual stress analyzer. It is demonstrated that the residual stress provide reliable informations about the machining states. Moreover, machining states can be detected successfully using both the residual stress and AE count rate.e.

  • PDF

An New Load Allocation Algorithms of Direct Load Control (직접부하제어 시스템의 새로운 부하 배분 알고리즘)

  • Kim, Jeong-Uk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.2
    • /
    • pp.407-410
    • /
    • 2010
  • This paper presents an advanced load allocation algorithm in Direct Load Control(DLC) system. It is important to aggregate a various demand side resource which is surely controllable at the peak power time for a successful DLC system. Previous load allocation algorithm appropriate for DLC system is based on interchanged information, but, this algorithm can not derive optimal solutions. In this paper, we develop the optimal algorithm and the new load allocation algorithm in polynomial time. The simulation results show that the proposed heuristic algorithm for DLC system is very effective.

Breeding of Fragrant Yellow Phalaenopsis and Scent Pattern Analysis by GC/SAW Electronic Nose System (유향성 황색계 호접란 육성 및 전자코를 이용한 향기패턴 분석)

  • Been, Chul-Gu
    • Horticultural Science & Technology
    • /
    • v.28 no.4
    • /
    • pp.656-663
    • /
    • 2010
  • In order to improve the consumer acceptance of fragrant yellow hybrids of $Phalaenopsis$ ($Phal.$), crosses between yellow hybrid varieties were made and the obtained hybrids were investigated for horticultural characteristics as well as difference in fragrance patterns. Cross combination of $Phal.$ Brother lawrence and $Phal.$ Brother saragold yielded good seedling population of 500 plants. Segregation was noticed in color density, spot and stripe patterns on yellow color base of petal and also in fragrance. Six lines with multi-branch on flower stalk and strong fragrance flower were finally selected. Volatile fragrance components were compared among $Phal.$ Brother lawrence, $Phal.$ Brother saragold and their hybrids by GC/SAW electronic nose. In the derivative pattern of chromatogram and polar derivative pattern of fragrance, similar dominant peaks appeared on retention time 7-9 s and some hybrid lines had two strong peaks on retention time 20-25 s, respectively. Also in polar frequency pattern of fragrance obtained by $VaporPrint^{TM}$ image analysis among parent flowers and hybrids, an identical strong peak near 8 s of retention time was shown. This single fragrance component is considered a key element of fragrance in $Phal.$ Brother lawrence, $Phal.$ Brother saragold and their hybrids. This peak could be used as a marker for the breeding of fragrance in $Phalaenopsis$.

Derivation of the Instantaneous Unit Hydrograph and Estimation of the Direct Runoff by Using the Geomorphologic Parameters (지상인자에 의한 순간단위도 유도와 유출량 예측)

  • 천만복;서승덕
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.32 no.3
    • /
    • pp.87-101
    • /
    • 1990
  • The purpose of this study is to estimate the flood discharge and runoff volume at a stream by using geomorphologic parameters obtained from the topographic maps following the law of stream classification and ordering by Horton and Strahier. The present model is modified from Cheng' s model which derives the geomorphologic instantaneous unit hydrograph. The present model uses the results of Laplace transformation and convolution intergral of probability density function of the travel time at each state. The stream flow velocity parameters are determined as a function of the rainfall intensity, and the effective rainfall is calculated by the SCS method. The total direct runoff volume until the time to peak is estimated by assuming a triangular hydrograph. The model is used to estimate the time to peak, the flood discharge, and the direct runoff at Andong, Imha. Geomchon, and Sunsan basin in the Nakdong River system. The results of the model application are as follows : 1.For each basin, as the rainfall intensity doubles form 1 mm/h to 2 mm/h with the same rainfall duration of 1 hour, the hydrographs show that the runoff volume doubles while the duration of the base flow and the time to peak are the same. This aggrees with the theory of the unit hydrograph. 2.Comparisions of the model predicted and observed values show that small relative errors of 0.44-7.4% of the flood discharge, and 1 hour difference in time to peak except the Geomchon basin which shows 10.32% and 2 hours respectively. 3.When the rainfall intensity is small, the error of flood discharge estimated by using this model is relatively large. The reason of this might be because of introducing the flood velocity concept in the stream flow velocity. 4.Total direct runoff volume until the time to peak estimated by using this model has small relative error comparing with the observed data. 5.The sensitivity analysis of velocity parameters to flood discharge shows that the flood discharge is sensitive to the velocity coefficient while it is insensitive to the ratio of arrival time of moving portion to that of storage portion of a stream and to the ratio of arrival time of stream to that of overland flow.

  • PDF

EFFECT OF LIGHT INTENSITY ON THE POLYMERIZATION RATE OF COMPOSITE RESIN USING REAL-TIME MEASUREMENT OF VOLUMETRIC CHANCE (광조사 강도가 복합레진의 중합반응속도에 미치는 영향에 관한 실시간 체적측정법을 이용한 연구)

  • La, Sung-Ho;Lee, In-Bog;Kim, Chang-Keun;Cho, Byeong-Hoon;Lee, Kwang-Won;Son, Ho-Hyun
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.2
    • /
    • pp.135-141
    • /
    • 2002
  • Objectives : The aim of this study is to evaluate the effect of light intensity variation on the polymerization rate of composite resin using IB system (the experimental equipment designed by Dr. IB Lee) by which real-time volumetric change of composite can be measured. Methods : Three commercial composite resins [Z100(Z1), AeliteFil(AF), SureFil(SF)] were photopolymerized with Variable Intensity Polymerizer unit (Bisco, U.S.A.) under the variable light intensity (75/150/225/300/375/450mW$^2$) during 20 sec. Polymerization shrinkage of samples was detected continuously by IB system during 110 sec and the rate of polymerization shrinkage was obtained by its shrinkage data. Peak time(P.T.) showing the maximum rate of polymerization shrinkage was used to compare the polymerization rate. Results : Peak time decreased with increasing light intensity(p<0.05). Maximum rate of polymerization shrinkage increased with increasing light intensity(p<0.05). Statistical analysis revealed a significant positive correlation between peak time and inverse square root of the light intensity (AF:R=0.965, Zl:R=0.974, SF:R=0.927). Statistical analysis revealed a significant negative correlation between the maximum rate of polymerization shrinkage and peak time(AF:R=-0.933, Zl:R=-0.892, SF:R=-0.883), and a significant positive correlation between the maximum rate of polymerization shrinkage and square root of the light intensity (AF:R=0.988, Zl:R=0.974, SF:R=0.946). Discussion and Conclusions : The polymerization rate of composite resins used in this study was proportional to the square root of light intensity Maximum rate of polymerization shrinkage as well as peak time can be used to compare the polymerization rate. Real-time volume method using IB system can be a simple alternative method to obtain the polymerization rate of composite resins.

A Study on Development of Bus Arrival Time Prediction Algorithm by using Travel Time Pattern Recognition (통행시간 패턴인식형 버스도착시간 예측 알고리즘 개발 연구)

  • Chang, Hyunho;Yoon, Byoungjo;Lee, Jinsoo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.39 no.6
    • /
    • pp.833-839
    • /
    • 2019
  • Bus Information System (BIS) collects information related to the operation of buses and provides information to users through predictive algorithms. Method of predicting through recent information in same section reflects the traffic situation of the section, but cannot reflect the characteristics of the target line. The method of predicting the historical data at the same time zone is limited in forecasting peak time with high volatility of traffic flow. Therefore, we developed a pattern recognition bus arrival time prediction algorithm which could be overcome previous limitation. This method recognize the traffic pattern of target flow and select the most similar past traffic pattern. The results of this study were compared with the BIS arrival forecast information history of Seoul. RMSE of travel time between estimated and observed was approximately 35 seconds (40 seconds in BIS) at the off-peak time and 40 seconds (60 seconds in BIS) at the peak time. This means that there is data that can represent the current traffic situation in other time zones except for the same past time zone.