• 제목/요약/키워드: Peak response time

검색결과 405건 처리시간 0.024초

수용가 수요관리용 전지전력저장시스템의 최적용량 산정방법 (Optimal Capacity Determination Method of Battery Energy Storage System for Demand Management of Electricity Customer)

  • 조경희;김슬기;김응상
    • 전기학회논문지
    • /
    • 제62권1호
    • /
    • pp.21-28
    • /
    • 2013
  • The paper proposes an optimal sizing method of a customer's battery energy storage system (BESS) which aims at managing the electricity demand of the customer to minimize electricity cost under the time of use(TOU) pricing. Peak load limit of the customer and charging and discharging schedules of the BESS are optimized on annual basis to minimize annual electricity cost, which consists of peak load related basic cost and actual usage cost. The optimal scheduling is used to assess the maximum cost savings for all sets of candidate capacities of BESS. An optimal size of BESS is determined from the cost saving curves via capacity of BESS. Case study uses real data from an apartment-type factory customer and shows how the proposed method can be employed to optimally design the size of BESS for customer demand management.

A SE Approach to Predict the Peak Cladding Temperature using Artificial Neural Network

  • ALAtawneh, Osama Sharif;Diab, Aya
    • 시스템엔지니어링학술지
    • /
    • 제16권2호
    • /
    • pp.67-77
    • /
    • 2020
  • Traditionally nuclear thermal hydraulic and nuclear safety has relied on numerical simulations to predict the system response of a nuclear power plant either under normal operation or accident condition. However, this approach may sometimes be rather time consuming particularly for design and optimization problems. To expedite the decision-making process data-driven models can be used to deduce the statistical relationships between inputs and outputs rather than solving physics-based models. Compared to the traditional approach, data driven models can provide a fast and cost-effective framework to predict the behavior of highly complex and non-linear systems where otherwise great computational efforts would be required. The objective of this work is to develop an AI algorithm to predict the peak fuel cladding temperature as a metric for the successful implementation of FLEX strategies under extended station black out. To achieve this, the model requires to be conditioned using pre-existing database created using the thermal-hydraulic analysis code, MARS-KS. In the development stage, the model hyper-parameters are tuned and optimized using the talos tool.

Modulation of the Time Course of Cardiac Chronotropic Responses during Exposure to Affective Pictures

  • Estate M. Sokhadze;Lee, kyung-Hwa;Lee, Jong-Mee;Oh, Jong-In;Sohn, Jin-Hun
    • 한국감성과학회:학술대회논문집
    • /
    • 한국감성과학회 2000년도 춘계 학술대회 및 국제 감성공학 심포지움 논문집 Proceeding of the 2000 Spring Conference of KOSES and International Sensibility Ergonomics Symposium
    • /
    • pp.290-300
    • /
    • 2000
  • One of the most important topics in attentional and emotional modulation of cardiac responses is time course of cardiac chronotropic response. The reason lies in dual innervation of heart, which leads to occurrence of several phases of cardiac response during exposure to affective stimuli, determined by the balance of sympathetic and parasympathetic influences. Cardiac chronotropic reactivity thus represents quite effective measure capable to trace the moment when attending and orienting processes (i.e., sensory intake of stimulus) prime relevant behavioral response (ile., emotion with approach or avoidance tendencies). The aim of this study was to find the time course of heart rate (HR) responses typical for negative (disgust, surprise, fear, anger) and positive (happiness, pleasant erotic) affective pictures and to identify cardiac response dissociation for emotions with different action tendencies such as "approach" (surprise, anger, happiness) and "avoidance" (fear, sadness, disgust). Forty college students participated in this study where cardiac responses to slides from IAPS intended to evoke basic emotions (surprise, fear, anger, sadness, disgust, happiness, pleasant-erotic). Inter-beat intervals of HR were analyzed on every 10 sec basis during 60 sec long exposure to affective visual stimuli. Obtained results demonstrated that differentiation was observed at the very first 10s of exposure (anger-fear, surprise-sad, surprise-erotic, surprise-happiness paris), reaching the peak of dissociation at 30s (same pairs plus surprise-disgust and surprise-fear) and was still effective for some pairs (surprise-erotic, surprise-sad) even at 50s and 60s. discussed are potential cardiac autonomic mechanisms underlying attention and emotion processes evoked by affective stimulation and theoretical considerations implicated to understand the role of differential cardiac reactivity in the behavioral context (e.g., approach-avoidance tendencies, orienting-defense responses).

  • PDF

ATM망에서 Leaky Bucket 사용 감시 알고리즘의 Type-I/II 에러 분석 (Analysis of the Type-I/II Error for the Leaky Bucket Policing Algorithm in ATM Networks)

  • 이동호;안윤영;조유제
    • 한국통신학회논문지
    • /
    • 제17권12호
    • /
    • pp.1391-1400
    • /
    • 1992
  • 본 논문에서는 CCITT에서 ATM 망의 사용 감시 알고리즘에 대한 정확도의 평가 기준으로 고려하고 있는 type-I/II 에러의 평가방법을 제안하였다. 그리고, ON/OFF 트래픽 모델에 대한 LB(leaky bucket)방식의 type-I/II 에러 분석을 통하여 평균 셀률과 최대 셀률을 감시 제어하기 위한 LB파라 미터의 결정방법을 고찰하였다. LB파라미터인 계수기의 감소율 a와 한계치 M은 type-I 에러를 만족하는 a-M 특성곡선을 구한후, 이 중에서 type-II 에러를 만족하면서 반응시간이 최소가 되는 (a, M)의 쌍으로 결정할 수 있음을 제시하였다. 이때, ON/OFF 트래픽에 대한 LB방식의 a-M 특성곡선은 트래픽의 버스트성에 의해 결정되어 짐을 알 수 있었다. 그리고, 성능분석 결과로부터 LB 방식은 최대 셀률에는 비교적 좋은 제어 성능을 가지지만, 평균 셀률 제어에 있어서는 정확도와 반응시간과의 상반관계로 인해 문제가 있음을 알 수 있었다.

  • PDF

신륵사 다층전탑의 구조해석에 대한 연구 (Analytical Study of Static and Dynamic Responses of Multi-story Brick Pagoda of Silleuksa Temple)

  • 이가윤;이성민;이기학
    • 한국공간구조학회논문집
    • /
    • 제22권3호
    • /
    • pp.33-40
    • /
    • 2022
  • Recently, cultural heritages in South Korea gain many interests of restoration and preservation from the government since many of that have been severely damaged during earthquakes. Many previous studies in both terms of experimental and analytical approaches have been done to examine structural behavior and decide appropriate methods of preservation. Being motivated by such researches, this research aims to investigate a religious stone pagoda dated back to the Goryeo Dynasty in Korea. The structure consists of a granite stone foundation and baked bricks, which resembles the shape of traditional pagodas. In order to examine the structural behavior of the pagoda, an analytical model is implemented using ANSYS, a comprehensive engineering simulation platform. For the time history analysis of the pagoda, several earthquake excitations are chosen and input to simulation modeling. Seismic response of the tower such as time domain, natural frequency, modal shapes and peak acceleration measured at each layer are presented and discussed. In addition, the amplification ratio of the tower is calculated from the accelerations of each layer to determine tower stability in accordance with Korean seismic design guide. The determination and evaluation of status and response of the brick tower by simulation analysis play an important role in the preservation of history as well as valuable architectural heritages in South Korea.

포항지진에 대한 원자력발전소 구조물 및 기기의 지진응답분석 (Seismic Response Analysis of Nuclear Power Plant Structures and Equipment due to the Pohang Earthquake)

  • 임승현;최인길
    • 한국지진공학회논문집
    • /
    • 제22권3호
    • /
    • pp.113-119
    • /
    • 2018
  • The probabilistic seismic safety assessment is one of the methodology to evaluate the seismic safety of the nuclear power plants. The site characteristics of the nuclear power plant should be reflected when evaluating the seismic safety of the nuclear power plant. The Korea seismic characteristics are strong in high frequency region and may be different from NRC Regulatory Guide 1.60, which is the design spectrum of nuclear power plants. In this study, seismic response of a nuclear power plant structure by Pohang earthquake (2017.11.15. (KST)) is investigated. The Pohang earthquake measured at the Cheongsong seismic observation station (CHS) is scaled to the peak ground acceleration (PGA) of 0.2 g and the seismic acceleration time history curve corresponding to the design spectrum is created. A nuclear power plant of the containment building and the auxiliary buildings are modeled using OPENSEES to analyze the seismic response of the Pohang earthquake. The seismic behavior of the nuclear power plant due to the Pohang earthquake is investigated. And the seismic performances of the equipment of a nuclear power plant are evaluated by the HCLPF. As a result, the seismic safety evaluation of nuclear power plants should be evaluated based on site-specific characteristics of nuclear power plants.

마찰형 감쇠를 갖는 구조물의 응답 스펙트럼 (Response Spectra of Structure Installed Frictional Damping System)

  • 박지훈;윤경조;민경원;이상현
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.893-897
    • /
    • 2006
  • Structures with additional frictional damping system have strong nonlinearity that the dynamic behavior is highly affected. by the relative magnitude between frictional force and excitation load. In this study, normalized response spectra of the structures with non-dimensional friction force are obtained through nonlinear time history analyses of the mass-normalized single degree of freedom systems using 20 ground motion data recorded on rock site. The variation of the control performance of frictional damping system is investigated in terms of the dynamic load and the structural natural period, of which effects were not considered in the previous studies. Least square curve fitting equations are presented for describing those normalized response spectrum and optimal non-dimensional friction forces are obtained for controlling the peak displacement and absolute acceleration of the structure based on the derivative of the curve fitted design spectrum.

  • PDF

Influence of Temperature Shifts on Antibody Synthesis in the Oliver Flounder (Paralichthys olivaceus) Immunised with Formalin Killed Edwardsiella tarda Antigen

  • 정현도;윤소혜;정준기;전린진;정준범;이준우
    • 한국어병학회지
    • /
    • 제19권3호
    • /
    • pp.235-241
    • /
    • 2006
  • The effects of various temperature shifts on the kinetics of the humoral antibody response in oliver flounder, Paralichthys olivaceus, immunised with formalin-killed Edwardsiella tarda, were determined by measuring the antibody production in vivo and in vitro. When fish acclimated to a high temperature and immunised at that temperature were transferred to a lower temperature (22℃ to 12℃) at a various times after immunisation, the fish showed a weaker immune response than that achieved when the fish were kept at a high environmental temperature. However, in the converse experiment (12℃ to 22℃), the magnitude of the humoral immune response was recovered independent of the time of the transfer after immunisation at low temperature, even though the peak levels of each transferred group did not reach the level found in the positive control group that was maintained and immunised at a high environmental temperature. Hence, these studies provide some evidence that the potential for antibody production in B cells of oliver flounder immunized at high temperature is not impaired by subsequent exposure to low temperature.

Pituitary and Gonadal Response to GnRH in Prepubertal Buffaloes (Bubalus bubalis)

  • Singh, C.;Madan, M.L.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제11권1호
    • /
    • pp.78-83
    • /
    • 1998
  • The objective of this study was to investigate the responsiveness of hypophysis and gonads to synthetic GnRH among prepubertal buffalo heifers at 12 months of age. Peripheral plasma FSH, LH, estradiol and progesterone level were measured in blood samples collected at 1 hr before and up to 18 days subsequent to the administration of $200{\mu}g$ GnRH (n=6) or saline (n=6) in Murrah buffalo heifers. The pretreatment peripheral plasma FSH, LH, estradiol and progesterone among GnRH treated heifers were $7.35{\pm}0.45ng/ml$, $1.08{\pm}0.3ng/ml$, $22.93{\pm}1.06pg/ml$ and $0.27{\pm}0.04ng/ml$ respectively. A quick elevation (p < 0.01) of FSH and LH within five min of GnRH administration was observed in all geifers. Although the peak FSH $(89.57{\pm}23.43ng/ml)$ and LH $(7.52{\pm}3.08ng/ml)$ reached by 10 min of GnRH administration, yet the animals differed both in terms of their amplitude response of FSH and LH release as well as in terms of time which animals took to exhiit maximum response to GnRH administration. The GnRH administration did not cause alteration in plasma estradiol and progesterone level. The present study suggests that the pituitary of 12 month buffalo heifers has capacity to synthesize and store of gonadotropin and have developed receptors for GnRH for a spike of gonadotropin release.

마찰형 감쇠를 갖는 구조물의 응답 스펙트럼 (Response Spectra of Structure Installed Frictional Damping System)

  • 박지훈;윤경조;민경원;이상현
    • 한국소음진동공학회논문집
    • /
    • 제17권1호
    • /
    • pp.88-94
    • /
    • 2007
  • Structures with additional frictional damping system have strong nonlinearity that the dynamic behavior is highly affected by the relative magnitude between frictional force and excitation load. In this study, normalized response spectra of the structures with non-dimensional friction force are obtained through nonlinear time history analyses of the mass-normalized single degree of freedom systems using 20 ground motion data recorded on rock site. The variation of the control performance of frictional damping system is investigated in terms of the dynamic load and the structural natural period, of which effects were not considered in the previous studies. Least square curve fitting equations are presented for describing those normalized response spectrum and optimal non-dimensional friction forces are obtained for controlling the peak displacement and absolute acceleration of the structure based on the derivative of the curve-fitted design spectrum.