• 제목/요약/키워드: Peak pressure

검색결과 1,452건 처리시간 0.028초

화재완화를 위한 소듐 루프 건물의 구획화 (Fire Mitigation by Partitioning a Sodium Loop Building)

  • 김병호;권상운;정경채;김광락;황성태
    • 한국안전학회지
    • /
    • 제13권3호
    • /
    • pp.32-44
    • /
    • 1998
  • Analysis on the study for the sodium fire mitigation was carried out using the CONTAIN-LMR code. Sodium loop building was partitioned into the many cells, in which the safety venting systems were installed for the purpose of improving the sodium fire safety and minimizing its effect on the sodium loop building. The effects of sodium fire on sodium loop building partitioned into the many cells and not partitioned were investigated. The peak pressure and temperature of each cell accompanied by sodium fire in sodium loop building partitioned were lower than those of sodium loop building not partitioned. In the case of partitioning sodium loop building, the pressures, temperatures and aerosols into cells were transferred through propagation path of CONTAIN-LMR sodium fire model simulated by this study, and the effect of sodium spray fire on sodium loop building was mitigated by partitioning building. In addition, the excessive rise of pressure into cells was prevented by installing the over-pressure exhaust valve and under-pressure exhaust valve on the flow path between cells.

  • PDF

Comparison of vertical ground reaction forces between female elderly and young adults during sit-to-stand and gait using the Nintendo Wii Balance Board

  • Lim, Ji Young;Yi, Yoonsil;Jung, Sang Woo;Park, Dae-Sung
    • Physical Therapy Rehabilitation Science
    • /
    • 제7권4호
    • /
    • pp.179-185
    • /
    • 2018
  • Objective: The purpose of this study was to analyze and compare vertical ground reaction forces during sit to stand (STS) and gait between female elderly and young individuals using the Wii Balance Board (WBB). Design: Cross-sectional study. Methods: Fifty-one female elderly people (age: $75.18{\pm}4.60years$), and 13 young people (age: $29.85{\pm}3.69years$) performed the five times STS test and gait respectively on the WBB. We analyzed time (s), vertical peak (%), integral summation (Int_SUM, %), and counter variables (%) in STS and 1st peak (body weight, BW%), 2nd peak (BW%), peak minimum (BW%), time (second), center of pressure (COP) path length (mm), and Int_SUM (BW%) in gait. The independent t-test was used to assess for differences in STS, gait ability, and general characteristics between the female elderly group and young adults group. With the first and last trials excluded, the mean value was obtained from the middle three of the five trials. Results: During STS, Int_SUM and time of young adults were significantly less than of the female elderly subjects. There were no significant differences in peak and counter variables. In gait, all variables (1st peak, 2nd peak, min, time, COP_path, and Int_SUM) showed significant differences between groups (p<0.05). This study demonstrated that the validity of vertical ground reaction forces occurring during STS and gait was significant in female elderly and young adults. Conclusions: Based on the measurement of vertical ground reaction forces in STS and gait using the WBB, it is possible to clinically improve the quality of geriatric physical therapy. Further studies are necessary to examine concurrent validity of elderly patients who have undergone total hip or knee replacement.

Simulated tropical cyclonic winds for low cycle fatigue loading of steel roofing

  • Henderson, David J.;Ginger, John D.;Morrison, Murray J.;Kopp, Gregory A.
    • Wind and Structures
    • /
    • 제12권4호
    • /
    • pp.383-400
    • /
    • 2009
  • Low rise building roofs can be subjected to large fluctuating pressures during a tropical cyclone resulting in fatigue failure of cladding. Following the damage to housing in Tropical Cyclone Tracy in Darwin, Australia, the Darwin Area Building Manual (DABM) cyclic loading test criteria, that loaded the cladding for 10000 cycles oscillating from zero to a permissible stress design pressure, and the Experimental Building Station TR440 test of 10200 load cycles which increased in steps to the permissible stress design pressure, were developed for assessing building elements susceptible to low cycle fatigue failure. Recently the 'Low-High-Low' (L-H-L) cyclic test for metal roofing was introduced into the Building Code of Australia (2007). Following advances in wind tunnel data acquisition and full-scale wind loading simulators, this paper presents a comparison of wind-induced cladding damage, from a "design" cyclone proposed by Jancauskas, et al. (1994), with current test criteria developed by Mahendran (1995). Wind tunnel data were used to generate the external and net pressure time histories on the roof of a low-rise building during the passage of the "design" cyclone. The peak pressures generated at the windward roof corner for a tributary area representative of a cladding fastener are underestimated by the Australian/New Zealand Wind Actions Standard. The "design" cyclone, with increasing and decreasing wind speeds combined with changes in wind direction, generated increasing then decreasing pressures in a manner similar to that specified in the L-H-L test. However, the L-H-L test underestimated the magnitude and number of large load cycles, but overestimated the number of cycles in the mid ranges. Cladding elements subjected to the L-H-L test showed greater fatigue damage than when experiencing a five hour "design" cyclone containing higher peak pressures. It is evident that the increased fatigue damage was due to the L-H-L test having a large number of load cycles cycling from zero load (R=0) in contrast to that produced during the cyclone.

유압식 굴삭기 효율 향상을 위한 HPM 시스템 개발 (Development of the HPM System to Improve Efficiency of the Hydraulic Excavator)

  • 권용철;이경섭;김성훈;구병국
    • 드라이브 ㆍ 컨트롤
    • /
    • 제16권4호
    • /
    • pp.1-8
    • /
    • 2019
  • The HPM (High-speed Power Matching) system is an electro-hydraulic control system. It directly controls the swash plate of the pump by selecting four-loop logic based on joystick signals, pump flow, and pressure signal to improve the efficiency and controllability of construction machines. In the NFC (Negative Flow Control) system, a typical pump control system using conventional open center type MCV, the loss is continuously generated by flow through the center bypass line even when the excavator is not in operation. Also, due to the slow response of the pump that indirectly controls the flow rate using the pressure regulator, peak pressure occurs at the start or stop of the operation. Conversely, the HPM system uses an MCV without center-by-pass flow path and the swash plate of a pump for the HPM is controlled by a high-speed proportional flow control valve. As a result, the HPM system minimizes energy loss in standby state of the excavator and enables peak pressure control through rapid electro-hydraulic control of a pump. In this paper, the concept of the HPM system algorithm is introduced and the hydraulic system efficiency is compared with the NFC system using the excavator SAT (System Analysis Tool).

쌍곡포물선 대공간구조물의 지붕 풍압계수분포 특성 (Characteristic of Wind Pressure Distribution on the Roof of Hyperbolic Paraboloid Spatial Structures)

  • 유기표;김영문
    • 한국공간구조학회논문집
    • /
    • 제12권3호
    • /
    • pp.47-54
    • /
    • 2012
  • 대공간 건축물의 특징 중 경량화 된 지붕 구조 및 재료의 사용으로 인해 지붕면의 손상이나 파괴 등의 피해가 많다. 대규모 경기장의 경우에는 지붕의 구조가 철골 트러스와 인장케이블을 기반으로 테프론이라는 막재료를 사용하여 구조체를 감싸거나 덮는 형태로 많이 설계가 되는데, 특히 이 막재료의 피해가 많으며 심각한 상황이다. 이러한 사례를 통해 대공간 건축물의 지붕에 대한 내풍설계 연구는 아직 미흡한 상태임을 알 수 있다. 본 논문은 쌍곡포물선 대공간구조물의 지붕의 형태에 대한 공기역학적인 특성을 알아보기 위하여 풍압실험과 유체해석을 실시하였다. 실험결과 바람이 불어오는 방향의 지붕 모서리에서 가장 큰 최소피크외압계수가 나타나지만 지붕의 길이방향으로 갈수록 최소피크풍압계수는 감소하고 있었다.

IRWST 환형관 실험장치 내의 수소화염 가속현상에 대한 CFD 해석 연구 (CFD ANALYSIS FOR HYDROGEN FLAME ACCELERATION IN THE IRWST ANNULUS TEST FACILITY)

  • 강형석;하광순;김상백;홍성완
    • 한국전산유체공학회지
    • /
    • 제17권3호
    • /
    • pp.75-86
    • /
    • 2012
  • We developed a preliminary CFD analysis methodology to predict a pressure build up due to hydrogen flame acceleration in the APR1400 IRWST on the basis of CFD analysis results for test data of hydrogen flame acceleration in a scaled-down test facility performed by Korea Atomic Energy Research Institute. We found out that ANSYS CFX-13 with a combustion model of the so-called turbulent flame closure and a model constant of A = 5.0, a grid model with a hexahedral cell length of 5.0 mm, and a time step size of $1.0{\times}10^{-5}$ s can be a useful tool to predict the pressure build up due to the hydrogen flame acceleration in the test results. Through the comparison of the simulated results with the test results, we found out that the proposed CFD analysis methodology enables us to predict the peak pressure within an error range of about ${\pm}29%$ for the hydrogen concentration of 19.5%. However, the error ranges of the peak pressure for the hydrogen concentration of 15.4% and 18.6% were about 66% and 51%, respectively. To reduce the error ranges in case of the hydrogen concentration of 15.4% and 18.6%, some uncertainties of the test conditions should be clarified. In addition, an investigation for a possibility of flame extinction in the test results should be performed.

이동작동기식 완전 이식형 인공 심장의 심실간 공간 압력 파형 해석에 관한 실험적 연구 (An Experimental Study on the Analysis of the Interventricular Pressure Waveform in the Moving-Actuator type Total Artificial Heart)

  • 조영호;최원우
    • 대한의용생체공학회:의공학회지
    • /
    • 제18권1호
    • /
    • pp.25-36
    • /
    • 1997
  • To regulate cardiac output of the Total Artificial Heart(TAH) physiologically, the hemodynamic information must be toed back to the controller. So far, our group has developed an automatic cardiac output control algorithm using the motor current waveform, It is, however difficult to detect the preload level such as a filling status of ventricular inflow and the variation of atrial pressures within normal physiologic range(0-15 mmHg) by analyzing the motor current which simultaneously reflects the afterload effect. On the other hin4 the interventricular volume pressure(IVP) which is not influenced by arterload but by preload is a good information source for the estimation of preload states. In order to find the relationship between preload and IVP waveform, we set up the artificial heart system on the Donovan type mock circulatory system and measured the IVP waveform, right and left atrial pressures, inflow and outflow waveforms and the signals represented the information of moving actuator's position. We shows the feasibility of estimating the hemodynamic changes of inflow by using IVP waveform. fife found that the negative peak value of IVP waveform is linearly related to atrial pressures. And we also found that we could use the time to reach the negative peak in IVP waveform, the time to open outflow valve, the area enclosed IVP waveform as unfu parameters to estimate blood filling volume of diastole ventricle. The suggested method has advantages of avoiding thrombogenesis, bacterial niche formation and increasing longterm reliability of sensor by avoiding direct contact to blood.

  • PDF

변압기 폭발/화재 방지 기술 (TRANSFORMER EXPLOSION AND FIRE PREVENTION)

  • 김형승;필리프매그너
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.93-94
    • /
    • 2007
  • An essential step for SERGI is to show the TRANSFORMER PROTECTOR (TP) efficacy for all transformers and all types of rupture of insulation. Its research program philosophy is thus to maintain a strong connection between experiments and the theoretical developments. Up to now, two TP test campaigns have been performed, both under the worst conditions by creating low impedance faults leading to electrical arcs inside the transformer tank dielectric oil. In 2002, Electricite de France performed 28 TP tests. Then, in 2004, a second campaign of 34 TP tests was carried out by CEPEL, the Brazilian independent High Voltage Laboratory. For the 62 tests, each transformer was equipped with the TP, which reacts directly to the moving dynamic pressure peak, shock wave, caused by the low impedance fault. When an electrical arc occurs, only one pressure peak is generated. The initial energy transfer is almost instantaneous, and so is the phase change. Because of the oil inertia, the gas is very quickly pressurised. As it is more difficult to vaporise a liquid than to crack oil-vapour into smaller molecules, the arc location would mainly remain in the gaseous phase after and less gas will be produced. As a result, when comparing tests for which pressure peaks are respectively equal to 8 bar (116 psi) and 8.8 bar (127 psi), the corresponding arc energies vary by an order 10 of magnitude (0.1 MJ and 1 MJ respectively). The correlation of the results obtained between arc energy and dynamic pressure demonstrates that the arc energy is not the key parameter during transformer tank explosion, which is in opposition with the common electrical engineers belief.

  • PDF

Effect of Modified High-heels on Metatarsal Stress in Female Workers

  • Kim, Kwantae;Peng, Hsien-Te
    • 한국운동역학회지
    • /
    • 제29권3호
    • /
    • pp.197-204
    • /
    • 2019
  • Objective: The purpose of this study was to identify the effect of high-heels (HH) modification on metatarsal stress in female workers. Method: Seven females who work in clothing stores ($heights=160.4{\pm}3.9cm$; $weights=47.4{\pm}4.1kg$; $age=31.3{\pm}11.1yrs$; $HH\;wear\;career=8{\pm}6.5yrs$) wore two types of HH (original and modified). The modified HH had been grooved with 1.5 cm radius and 0.2 cm depth around the first metatarsal area inside of the shoes using the modified shoe-last. Participants were asked to walk for 15 minutes on a treadmill and to stand for 10 minutes with original and modified HH, respectively. Kinetics data were collected by the F-scan in-shoe system. After each test, participants were asked to rate their perceived exertion using the Borg's 15-grade RPE scale and interviewed about their feeling of HH. Nonparametric Wilcoxon signed-rank test and effect size (Cohen's d) were used to determine the difference of the variables of interest between the original and modified HH. Results: In the present study, modified HH of the peak contact pressure of 1st metatarsal (PCP) left, PCP right, pressure time integral (PTI) left, peak pressure gradient (PPG) left during standing and PPG right during walking are greater than original HH. And even it didn't show statistically significant, the average in all pressure values of modified HH showed bigger than original HH. It surmised to be related to awkward with modified HH. Even though they said to feel the comfortable cause of big space inside of HH in the interview, they seemed to be not enough time to adapt with new HH. So their walking and standing postures were unstable. Conclusion: Modified the fore-medial part of HH can reduce the stress in the first metatarsal head and big toe area during standing and walking.

개선된 계단 배기 방법을 이용한 혈압 측정 (Blood Pressure Measurement using the Modified Step-wise Deflation Method)

  • 오홍식;이종실;지영준;김인영
    • 대한의용생체공학회:의공학회지
    • /
    • 제31권5호
    • /
    • pp.351-358
    • /
    • 2010
  • In the automatic non-invasive blood pressure measurement device, the oscillometric method iswidely used. In the oscillometric method, the step-wise deflation has the advantage of the robustness for the motion artifacts than the linear deflation method. But it has the disadvantage of its longer measurement time because we need to detect two or more pulses in a certain cuff pressure step. In this study, we suggest the modified step-wise deflation method to overcome this limitation while maintaining the general concept of step-wise deflation. Using one valid pulse in each step and the deflating valve control during the diastolic period, the measurement time could be reduced. In order to verify the accuracy of the proposed algorithm, we compared the blood pressure values from the suggested method and the blood pressure values from the conventional auscultation method. The mean and standard deviation were -0.50${\pm}$5.3mmHg and 2.08${\pm}$4.75mmHg, for systolic and diastolic blood pressure respectively. The measurement time can be reduced up to the half of conventional step-wise deflation method.