• Title/Summary/Keyword: Peak detection algorithm

Search Result 191, Processing Time 0.026 seconds

R-peak Detection Algorithm in Wireless Sensor Node for Ubiquitous Healthcare Application (유비쿼터스 헬스케어 시스템을 위한 노드기반의 R피크 검출 알고리즘)

  • Lee, Dae-Seok;Hwang, Gi-Hyun;Cha, Kyoung-Hwan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.1
    • /
    • pp.227-232
    • /
    • 2011
  • The QRS complex in ECG analysis is possible to obtain much information that is helpful for diagnosing different types of cardiovascular disease. This paper presents the preprocessor method to detect R-peak, RR interval, and HRV in wireless sensor node. The derivative of the electrocardiogram is efficiency of preprocessing method for resource hungry wireless sensor node with low computation. We have implemented R-peak and RR interval detection application based on dECG for wireless sensor node. The sensor node only transfers meaning parameter of ECG. Thus, implementation of sensor node can save power, reduce traffic, and eliminate congestion in a WSN.

Noise Reduction Algorithm For The Detection of Fine Ion Signals in Residual Gas Analyzer (잔류가스분석기의 질량 스펙트럼 검출 성능 향상을 위한 잡음제거 알고리즘)

  • Heo, Gyeongyong;Choi, Hun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.68 no.1
    • /
    • pp.102-107
    • /
    • 2019
  • This paper proposes a method to improve the mass spectral detection performance of the residual gas analyzer. By improving the mode estimation method for setting the threshold value and improving the additive noise elimination method, it is possible to detect mass spectrums having low peak values of the threshold level difficult to distinguish from noise. Ion signal blocks for each mass index with noise removed by the improved method are effective for eliminating invalid ion signals based on the linear and quadratic fittings. The mass spectrum can be obtained from the quadratic fitted curves for the reconstructed ion signal block using only the valid ion signals. In addition, the resolution of the mass spectrum can be improved by correcting the error caused by the shift of the spectral peak position. To verify the performance of the proposed method, computer simulations were performed using real ion signals obtained from the residual gas analysis system under development. The simulation results show that the proposed method is valid.

Development of a Novel Step Detection Algorithm for Gait Evaluation of Patients with Hemiplegia Based on Trunk Accelerometer (뇌졸중으로 인한 편마비 환자의 보행평가를 위한 체중심 가속도센서 기반의 새로운 보 검출 알고리즘 개발)

  • Lee, Hyo-Ki;Hwang, Sung-Jae;Cho, Sung-Pil;Lee, Dong-Ryul;You, Sung-Hyun;Lee, Kyoung-Joung;Kim, Young-Ho;Chung, Ha-Joong
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.3
    • /
    • pp.213-220
    • /
    • 2009
  • In this study, we have developed a novel step detection algorithm for gait evaluation of patients with hemiplegia based on trunk accelerometry device. For this, we have used a bandpass filter and a least square acceleration (LSA) filter which is characterized by emphasizing the peak or valley point of the acceleration signals for each 3-axis accelerometer signals. To evaluate the algorithm, the detected steps by developed algorithm and real steps by the motion analysis system were compared. As a result, we could obtain the sensitivity of 96.44%, the specificity of 99.94% and the accuracy of 99.90% for the patients' data sets and the sensitivity of 100%, the specificity of 99.93% and the accuracy of 99.93% for the normal data sets. In conclusion, the developed algorithm is useful for the step detection for patients with hemiplegia as well as normal subjects.

Implementation on SVM based Step Detection Analyzer (SVM 기반의 걸음 검출 분석기의 구현)

  • An, Kyung Ho;Kim, En Tae;Ryu, Uk Jae;Chang, Yun Seok
    • Journal of Korea Multimedia Society
    • /
    • v.16 no.10
    • /
    • pp.1147-1155
    • /
    • 2013
  • In this study, we designed and implemented a step detection analyzer that can compare and analyze the step detection rates and results among the step detection algorithms. The step detection analyzer converts 3-axes accelerometer data into continuous energy stream through SVM operation, shows the horizontal comparison among the step detection results for each step detection algorithms, and can make elemental detection analyses. For these processes, the step detection analyzer presents the continuous energy stream as energy waveform, checks the peak values and time location of the detected steps with step detection algorithms, and gives visual interface to get some possible causes in cases of step detection miss. It can also give the threshold graph for each algorithm to check the threshold value on missed cases directly and can help to get more appropriate threshold values or other adjustable parameters in step detection algorithm. This step detection analyzer can be applied efficiently on performance enhancement of step detection algorithm, on deciding an appropriate algorithm for a specific step counter system in the various step counter filed operations.

A New MPEG-2 Rate Control Scheme Using Scene Change Detection

  • Park, Sang-Gyu;Lee, Young-Sun;Chang, Hyun-Sik
    • ETRI Journal
    • /
    • v.18 no.2
    • /
    • pp.61-74
    • /
    • 1996
  • We propose two new rate control schemes to improve MPEG-2 rate control in view of visual quality when scene changes happen. Two proposed schemes are characterized by real-time and non real-time improvement to reduce the impact of scene changes. We also propose a new target-bit prediction method using spatial activity of pictures and present a simple and efficient scene change detection scheme using signed difference of mean absolute difference (MAD). Computer simulation results show that the proposed real-time algorithm effectively alleviates visual quality degradation after scene changes. The proposed non real-time algorithm gives maximum 2 dB improvement in peak signal-to-noise ratio (PSNR) at a scene-changed picture, compared with MPEG-2 rate control scheme and it shows better quality than the real-time one.

  • PDF

A Study on Feature Point Detection Algorithm in Radial Pulse (맥파 특징점 검출 알고리즘에 관한 연구)

  • Han, S.C.;Lee, Y.D.;Cho, B.S.;Park, Y.B.;Huh, W.
    • Proceedings of the IEEK Conference
    • /
    • 2000.06e
    • /
    • pp.207-209
    • /
    • 2000
  • In this paper, we developed a feature point detection algorithm that detects upstroke point(S), peak point(P), incisura(C) point from radial pulse waveform which obtained by using the developed radial pulse transducer. As the results of experiment the three kinds of parameters can extracted with effectively from normal radial pulse waveform.

  • PDF

X-ray Image Processing for the Korea Red Ginseng Inner Hole Detection (II) - Results of inner hole detection - (홍삼 내공검출을 위한 X-선 영상처리기술 (II) - 내공검출결과 -)

  • 손재룡;최규홍;이강진;최동수;김기영
    • Journal of Biosystems Engineering
    • /
    • v.28 no.1
    • /
    • pp.45-52
    • /
    • 2003
  • Red ginsengs are inspected manually by examining those in the dark room with back light illumination. Manual inspection is often influenced by physical condition of inspectors. Sometimes. the best grade, heaven. has some inner holes though it was inspected by a specialist. In order to resolve this problem, this study was performed to develop image processing algorithm to detect the inner holes in the x-ray image of ginseng. Because of little gray value difference between background and ginseng in the image. simple thresholding method was not appropriate. Modified watershed algorithm was used to differentiate the inner holes from background and normal ginseng body. Inner hole edge region detected by watershed algorithm consists of many number of blobs including normal portions. With line profile analysis with scanning one line at a time beginning the starting point. it shelved two peaks both ends representing extracting each blobs. in which setting threshold value as of lower peak value enabled us to obtain inner hole image. Once this procedure has to be done till the finishing point it is completing inner hole detection for one blob. Thus. conducting ail blobs by this procedure is completing inner detection of one whole ginseng. Detection results of the inner holes fer various size of red ginsengs were good even though there was small detection variation. 6.2%. according to position of x-rat tube.

A Study on Measurement of Heartrate and Respiration during Sleep using Doppler Radar: Preliminary Study (도플러 레이더를 이용한 수면 중의 심박 및 호흡 측정: 예비연구)

  • Lim, Yong Gyu
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.5
    • /
    • pp.264-270
    • /
    • 2017
  • A Doppler radar sensor was applied to detect respirations and heartbeats of persons who were lying on a bed. This study is preliminary study aiming at non-contact and non-intrusive respiration and heart rate monitoring during sleep in daily life. For the experiments, 10GHz Doppler radar with patch-type antenna was used and installed on the upper right and the distance between the body and the antenna was 1 m. The results show that each signal of respiration and heartbeat is observed in each frequency band however the frequency band and the waveform vary according to the subjects and the posture. The results show that the heartbeats can be detected with the peak detection in some frequency band. This study shows the feasibility of applying the Doppler radar to detection of heartbeat and respiration during sleep and further studies about heartbeat detection algorithm are required.

Robust Voice Activity Detection Using the Spectral Peaks of Vowel Sounds

  • Yoo, In-Chul;Yook, Dong-Suk
    • ETRI Journal
    • /
    • v.31 no.4
    • /
    • pp.451-453
    • /
    • 2009
  • This letter proposes the use of vowel sound detection for voice activity detection. Vowels have distinctive spectral peaks. These are likely to remain higher than their surroundings even after severe corruption. Therefore, by developing a method of detecting the spectral peaks of vowel sounds in corrupted signals, voice activity can be detected as well even in low signal-to-noise ratio (SNR) conditions. Experimental results indicate that the proposed algorithm performs reliably under various noise and low SNR conditions. This method is suitable for mobile environments where the characteristics of noise may not be known in advance.

Flattening Techniques for Pitch Detection (피치 검출을 위한 스펙트럼 평탄화 기법)

  • 김종국;조왕래;배명진
    • Proceedings of the IEEK Conference
    • /
    • 2002.06d
    • /
    • pp.381-384
    • /
    • 2002
  • In speech signal processing, it Is very important to detect the pitch exactly in speech recognition, synthesis and analysis. but, it is very difficult to pitch detection from speech signal because of formant and transition amplitude affect. therefore, in this paper, we proposed a pitch detection using the spectrum flattening techniques. Spectrum flattening is to eliminate the formant and transition amplitude affect. In time domain, positive center clipping is process in order to emphasize pitch period with a glottal component of removed vocal tract characteristic. And rough formant envelope is computed through peak-fitting spectrum of original speech signal in frequency domain. As a results, well get the flattened harmonics waveform with the algebra difference between spectrum of original speech signal and smoothed formant envelope. After all, we obtain residual signal which is removed vocal tract element The performance was compared with LPC and Cepstrum, ACF 0wing to this algorithm, we have obtained the pitch information improved the accuracy of pitch detection and gross error rate is reduced in voice speech region and in transition region of changing the phoneme.

  • PDF