• Title/Summary/Keyword: Peak Threshold

Search Result 303, Processing Time 0.026 seconds

A Simple and Robustness Algorithm for ECG R- peak Detection

  • Rahman, Md Saifur;Choi, Chulhyung;Kim, Young-pil;Kim, Sikyung
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.5
    • /
    • pp.2080-2085
    • /
    • 2018
  • There have been numerous studies that extract the R-peak from electrocardiogram (ECG) signals. All of these studies can extract R-peak from ECG. However, these methods are complicated and difficult to implement in a real-time portable ECG device. After filtration choosing a threshold value for R-peak detection is a big challenge. Fixed threshold scheme is sometimes unable to detect low R-peak value and adaptive threshold sometime detect wrong R-peak for more adaptation. In this paper, a simple and robustness algorithm is proposed to detect R-peak with less complexity. This method also solves the problem of threshold value selection. Using the adaptive filter, the baseline drift can be removed from ECG signal. After filtration, an appropriate threshold value is automatically chosen by using the minimum and maximum value of an ECG signals. Then the neighborhood searching scheme is applied under threshold value to detect R-peak from ECG signals. Proposed method improves the detection and accuracy rate of R-peak detection. After R-peak detection, we calculate heart rate to know the heart condition.

Accuracy Improvement Methode of Step Count Detection Using Variable Amplitude Threshold (가변 진폭 임계값을 이용한 걸음수 검출 정확도 향상 기법)

  • Ryu, Uk Jae;Kim, En Tae;An, Kyung Ho;Chang, Yun Seok
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.2 no.6
    • /
    • pp.257-264
    • /
    • 2013
  • In this study, we have designed the variable amplitude threshold algorithm that can enhance the accuracy of step count using variable amplitude. This algorithm converts the x, y, z sensor values into a single energy value($E_t$) by using SVM(Signal Vector Magnitude) algorithm and can pick step count out over 99% of accuracy through the peak data detection algorithm and fixed peak threshold. To prove the results, We made the noise filtering with the fixed amplitude threshold from the amplitude of energy value that found out the detection error was increasing, and it's the key idea of the variable amplitude threshold that can be adapted on the continuous data evaluation. The experiment results shows that the variable amplitude threshold algorithm can improve the average step count accuracy up to 98.9% at 10 Hz sampling rate and 99.6% at 20Hz sampling rate.

Speech/Music Discrimination Using Spectral Peak Track Analysis (스펙트럴 피크 트랙 분석을 이용한 음성/음악 분류)

  • Keum, Ji-Soo;Lee, Hyon-Soo
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.243-244
    • /
    • 2006
  • In this study, we propose a speech/music discrimination method using spectral peak track analysis. The proposed method uses the spectral peak track's duration at the same frequency channel for feature parameter. And use the duration threshold to discriminate the speech/music. Experiment result, correct discrimination ratio varies according to threshold, but achieved a performance comparable to another method and has a computational efficient for discrimination.

  • PDF

Verification about Threshold Discharge Computation using GIUH on ungauged small basin (지형학적순간단위도를 이용한 미계측 소유역의 한계유출량 산정 검증)

  • Choi Hyun;Lee Sang-Jin
    • Spatial Information Research
    • /
    • v.14 no.1 s.36
    • /
    • pp.15-27
    • /
    • 2006
  • This paper is about the threshold discharge computation using GIUH(Geomorphoclimatic Instantaneous Unit Hydrograph) on ungauged small basin. GIUH is one of the possible approaches to predicting the hydrograph characteristics. This study is calculated the various ways which are hydrologic characteristics, bankfull flows, unit peak flows(the Clark, the Nakayasu and the S.C.S) as well as threshold runoffs on about $5km^2$ scale at Kyungbuk gampo in subbasin. We are estimated propriety that peak discharge calculated the GIUH from acquiring data by GIS(Geographic Information System) compared to observed peak discharge. And, the threshold discharge was calculated by NRCS(Natural Resources Conservation Service) for a flash flood standard rainfall.

  • PDF

An Enhanced Step Detection Algorithm with Threshold Function under Low Sampling Rate (낮은 샘플링 주파수에서 임계 함수를 사용한 개선된 걸음 검출 알고리즘)

  • Kim, Boyeon;Chang, Yunseok
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.4 no.2
    • /
    • pp.57-64
    • /
    • 2015
  • At the case of peak threshold algorithm, 3-axes data should sample step data over 20 Hz to get sufficient accuracy. But most of the digital sensors like 3-axes accelerometer have very low sampling rate caused by low data communication speed on limited SPI or $I^2C$ bandwidth of the low-cost MPU for ubiquitous devices. If the data transfer rate of the 3-axes accelerometer is getting slow, the sampling rate also slows down and it finally degrades the data accuracy. In this study, we proved there is a distinct functional relation between the sampling rate and threshold on the peak threshold step detection algorithm under the 20Hz frequency, and made a threshold function through the experiments. As a result of experiments, when we apply threshold value from the threshold function instead of fixed threshold value, the step detection error rate can be lessen about 1.2% or under. Therefore, we can suggest a peak threshold based new step detection algorithm with threshold function and it can enhance the accuracy of step detection and step count. This algorithm not only can be applied on a digital step counter design, but also can be adopted any other low-cost ubiquitous sensor devices subjected on low sampling rate.

An application of wavelet transform toward noisy NMR peak suppression

  • Kim, Daesung;Kim, Dai-Gyoung
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.6 no.1
    • /
    • pp.12-19
    • /
    • 2002
  • A shift-averaged Haar wavelet transform was introduced as a new and excellent tool to distinguish real peaks from the noise contaminated NMR signals. It is based on Haar wavelet transform and translation-invariant denoising process. Donoho's universal threshold was newly introduced to the shift-averaged Haar wavelet transform for the purpose of automated noise suppression, and was quantitatively compared with the conventional uniform threshold method in terms or threshold and signal to noise ratio (SNR). New algorithm was combined with a routine to suppress a large solvent peak by singular value decomposition (SVD). Combined algorithm was applied to the real spectrum that containing large solvent peak.

  • PDF

Localization of insulation defect applying Threshold-Initial peak detection method (Threshold-Initial peak detection을 이용한 가스 절연 변압기의 절연 결함 위치 판별)

  • Son, Ui-Kwon;Oh, Choong-Seok;Jung, Seung-Yong;Lee, Bang-Wook;Koo, Ja-Yoon
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1376-1377
    • /
    • 2008
  • 가스절연변압기(GITr)는 우수한 절연내력과 높은 신뢰성을 장점으로 가지고 있지만, 제작과 운전 단계에서 절연 결함이 발생할 수 있고 이러한 결함들은 가스절연변압기 사고의 원인이 될 수 있다. 따라서 결함에 대한 상시 진단 및 원인 분석이 반드시 선행되어야 하며 이와 같은 진단 분석 기법의 하나로 내부 절연결함의 위치 판별에 대한 연구의 필요성이 절실히 요구되고 있다. 따라서 본 논문에서는 일반적으로 부분 방전의 위치 판별을 위한 time delay 측정법 중 하나인 Cross-correlation 방법과 함께 제안한 Threshold-Initial peak detection 방법을 적용하여 위치 데이터를 취득하고 신뢰구간 이내의 데이터만 사용하여 부분 방전 위치 판별 한 결과, 더욱 정확한 위치 판별이 가능하였다.

  • PDF

TAR(Threshold Autoregressive) Model for Short-Term Load Forecasting Using Nonlinearity of Temperature and Load (온도와 부하의 비선형성을 이용한 단기부하예측에서의 TAR(Threshold Autoregressive) 모델)

  • Lee, Gyeong Hun;Lee, Yun Ho;Kim, Jin O
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.9
    • /
    • pp.399-399
    • /
    • 2001
  • This paper proposes TAR(Threshold Autoregressive) model for short-term load forecasting including temperature variable. In the scatter diagram of daily peak load versus daily high or low temperature, we can find out that the load-temperature relationship has a negative slope in the lower regime and a positive slope in the upper regime due to the heating and cooling load, respectively. TAR model is adequate for analyzing these phenomena since TAR model is a piecewise linear autoregressive model. In this paper, we estimated and forecasted one day-ahead daily peak load by applying TAR model using this load-temperature characteristic in these regimes. The results are compared with those of linear and quadratic regression models.

TAR(Threshold Autoregressive) Model for Short-Term Load Forecasting Using Nonlinearity of Temperature and Load (온도와 부하의 비선형성을 이용한 단기부하예측에서의 TAR(Threshold Autoregressive) 모델)

  • Lee, Gyeong-Hun;Lee, Yun-Ho;Kim, Jin-O
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.9
    • /
    • pp.309-405
    • /
    • 2001
  • This paper proposes TAR(Threshold Autoregressive) model for short-term load forecasting including temperature variable. In the scatter diagram of daily peak load versus daily high or low temperature, we can find out that the load-temperature relationship has a negative slope in the lower regime and a positive slope in the upper regime due to the heating and cooling load, respectively. TAR model is adequate for analyzing these phenomena since TAR model is a piecewise linear autoregressive model. In this paper, we estimated and forecasted one day-ahead daily peak load by applying TAR model using this load-temperature characteristic in these regimes. The results are compared with those of linear and quadratic regression models.

  • PDF

Wearable Approach of ECG Monitoring System for Wireless Tele-Home Care Application

  • Kew, Hsein-Ping;Noh, Yun-Hong;Jeong, Do-Un
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.05a
    • /
    • pp.337-340
    • /
    • 2009
  • Wireless tele-home-care application gives new possibilities for ECG (electrocardiogram) monitoring system with wearable biomedical sensors. Thus, continuously development of high convenient ECG monitoring system for high-risk cardiac patients is essential. This paper describes to monitor a person's ECG using wearable approach. A wearable belt-type ECG electrode with integrated electronics has been developed and has proven long-term robustness and monitoring of all electrical components. The measured ECG signal is transmitted via an ultra low power consumption wireless sensor node. ECG signals carry a lot clinical information for a cardiologist especially the R-peak detection in ECG. R-peak detection generally uses the threshold value which is fixed thus it bring errors due to motion artifacts and signal size changes. Variable threshold method is used to detect the R-peak which is more accurate and efficient. In order to evaluate the performance analysis, R-peak detection using MIT-BIH databases and Long Term Real-Time ECG is performed in this research. This concept able to allow patient to follow up critical patients from their home and early detecting rarely occurrences of cardiac arrhythmia.

  • PDF