• Title/Summary/Keyword: Peak Sound Pressure

Search Result 57, Processing Time 0.025 seconds

Analysis of Rattle Noise of a Direct Engine-driven PTO Driveline of Tractors (엔진 직결식 트랙터 PTO 전동 라인의 치타음 분석)

  • Park, Y.J.;Kim, K.U.
    • Journal of Biosystems Engineering
    • /
    • v.31 no.1 s.114
    • /
    • pp.1-8
    • /
    • 2006
  • This study was conducted to identify the characteristics of PTO rattle noise of a direct engine-PTO driveline for agricultural tractors. In order to reduce production costs of agricultural tractors, a direct engine-PTO driveline was recently introduced to the tractors produced in Korea. This simplified drive line reduced a number of gears and counter shafts in previous one. However, it caused a severe rattle noise under an idle condition, which was perceived as intolerable by many tractor operators. PTO rattle noise was measured at two locations: one 3 em apart radially from the centerline of the PTO shaft and another 100 em apart backward from the PTO end and 160 em high from the ground. Characteristics of the rattle was analyzed using the data measured near the PTO shaft. It was found that the period of rattle noise was same as the explosion stroke of engine and its peak level was about 123 dB (A) with PTO engaged at an idle engine speed of 880 rpm. As the engine speed increased, the rattle noise decreased. The frequency band of the rattle was 0.5-2.0 kHz and the frequency of peak sound pressure was 1.4 kHz. When compared the rattle noise between the locally produced and imported tractors of the same type of PTO driveline, the former generated louder rattle noise than the imported one by 7 dB (A). It was suggested that the rattle noise of local tractors must be reduced at least by 7 dB (A) to meet the international level.

Comparative study on dynamic properties of argillaceous siltstone and its grouting-reinforced body

  • Huang, Ming;Xu, Chao-Shui;Zhan, Jin-Wu;Wang, Jun-Bao
    • Geomechanics and Engineering
    • /
    • v.13 no.2
    • /
    • pp.333-352
    • /
    • 2017
  • A comparison study is made between the dynamic properties of an argillaceous siltstone and its grouting-reinforced body. The purpose is to investigate how grout injection can help repair broken soft rocks. A slightly weathered argillaceous siltstone is selected, and part of the siltstone is mechanically crushed and cemented with Portland cement to simulate the grouting-reinforced body. Core specimens with the size of $50mm{\times}38mm$ are prepared from the original rock and the grouting-reinforced body. Impact tests on these samples are then carried out using a Split Hopkinson Pressure Bar (SHPB) apparatus. Failure patterns are analyzed and geotechnical parameters of the specimens are estimated. Based on the experimental results, for the grouting-reinforced body, its shock resistance is poorer than that of the original rock, and most cracks happen in the cementation boundaries between the cement mortar and the original rock particles. It was observed that the grouting-reinforced body ends up with more fragmented residues, most of them have larger fractal dimensions, and its dynamic strength is generally lower. The mass ratio of broken rocks to cement has a significant effect on its dynamic properties and there is an optimal ratio that the maximum dynamic peak strength can be achieved. The dynamic strain-softening behavior of the grouting-reinforced body is more significant compared with that of the original rock. Both the time dependent damage model and the modified overstress damage model are equally applicable to the original rock, but the former performs much better compared with the latter for the grouting-reinforced body. In addition, it was also shown that water content and impact velocity both have significant effect on dynamic properties of the original rock and its grouting-reinforced body. Higher water content leads to more small broken rock pieces, larger fractal dimensions, lower dynamic peak strength and smaller elastic modulus. However, the water content plays a minor role in fractal dimensions when the impact velocity is beyond a certain value. Higher impact loading rate leads to higher degree of fragmentation and larger fractal dimensions both in argillaceous siltstone and its grouting-reinforced body. These results provide a sound basis for the quantitative evaluation on how cement grouting can contribute to the repair of broken soft rocks.

Characteristics and Fabrication of Multi-Layered Piezoelectric Ceramic Actuators for Speaker Application (스피커 응용을 위한 적층형 압전 세라믹 액츄에이터 제조 및 특성)

  • Lee, Min-seon;Yun, Ji-sun;Park, Woon Ik;Hong, Youn-Woo;Paik, Jong Hoo;Cho, Jeong Ho;Park, Yong-Ho;Jeong, Young-Hun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.10
    • /
    • pp.601-607
    • /
    • 2016
  • Piezoelectric thick films of soft $Pb(Zr,Ti)O_3$ (PZT) based commercial material (S55) were fabricated using a conventional tape casting method. Ag-Pd electrodes were printed on the piezoelectric film at room temperature and all 5 layered films with a dimension of $12mm{\times}16mm$ were successfully laminated for a multi-layered piezoelectric ceramic actuator. The laminated specimens were co-fired at $1,100^{\circ}C$ for 1 h. A flat layered and dense microstructure was obtained for the $112{\mu}m$ thick piezoelectric actuator after sintering process. Thereafter, a prototype piezoelectric speaker was fabricated using the multi-layered piezoelectric ceramic actuator which can operate as a bimorph. Its SPL (sound pressure level) characteristic was also evaluated for speaker application. Frequency response revealed that the output SPL with a root mean square voltage of 10 V increased gradually to the highest peak of 87.5 dB for 1.5 kHz and exhibited a relatively stable behavior over the measured frequency range (${\leq}20kHz$) at a distance of 10 cm, implying that the fabricated piezoelectric speaker is potential for speaker applications.

An Analysis of the Flow Field and Radiation Acoustic Field of a Centrifugal Impeller with Wedge(I) -An Analysis of the Flow Field and Aeroacoustic Source- (웨지가 있는 원심 임펠러의 유동 및 방사 음향장 해석(I) -유동장 및 소음원 해석-)

  • Lee, Deok-Ju;Jeon, Wan-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.9
    • /
    • pp.1157-1164
    • /
    • 2001
  • Centrifugal fans are widely used and the noise generated by these machines causes one of the most serious problems. In general, the centrifugal fan noise is often dominated by tones at BPF(blade passage frequency) and its higher harmonics. This is a consequence of the strong interaction between the flow discharged from the impeller and the cutoff in the casing. However, only a few research have been carried out on predicting the noise because of the difficulty in obtaining detailed information about the flow field and casing effects on noise radiation. The objective of this study is to understand the generation mechanism of sound and to develop a prediction method for the unsteady flow field and the acoustic pressure field of a centrifugal fan. We assume that the impeller rotates with a constant angular velocity and the flow field of the impeller is incompressible and inviscid. So, a discrete vortex method(DVM) is used to model the centrifugal fan and to calculate the flow field. The force of each element on the blade is calculated by the unsteady Bernoulli equation. Lowsons method is used to predict the acoustic source. In order to compare the experimental data, a centrifugal impeller and wedge introduced by Weidemann are used in the numerical calculation and the results are compared with the experimental data. Reasonable results are obtained not only for the peak frequencies but also for the amplitudes of the tonal.

A study of the measurement systems implementation for the interior impulse noise (실내 충격소음 측정시스템 구현에 관한 연구)

  • Song, Kee-Hyeok;Chung, Sung-Hak
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.6
    • /
    • pp.93-100
    • /
    • 2014
  • The objective of this study is to propose the measurement system implementation method for the evaluation and measurement of the indoor-impulsive over 170 dB noise source. For the purpose of measuring impulse noise, design and implementation constructed followed subsystems of the testing center, microphone, ear simulator, head and torso simulator and so on. Measurement systems for the accuracy and reliability of impulse noise are implemented when measuring 3 ways of measurements method by the simultaneous measurement system design. For the accuracy and reliability of three mutually indoor-impulse noise measurements were compared, three kinds of measuring methods in accordance with the peak sound pressure level and octave band. Comparing the results of data, the indoor-impulse noise by analyzing a frequency characteristic was validated in difference for the statistical significance. Result are determined by the influence of the reflected wave. Therefore, the flexible size of the interior test site while interior impulse noise measurement system was constructed. Throughout this system can be affected by parameters that are the impulse noise source and the corresponding frequency-characteristic analysis to determine the spectrum of the reflected wave. And, in the near future, indoor impulse noise measurement systems for acquisition and analysis are utilized in useful data.

A retrospective clinical study of isolated patent ductus arteriosus (동맥관 개존증의 임상적 고찰)

  • 곽영태
    • Journal of Chest Surgery
    • /
    • v.17 no.4
    • /
    • pp.593-606
    • /
    • 1984
  • With the ligation of patent ductus arteriosus by Gross in 1938, surgeons first entered the field of congenital heart disease. Interruption of a ductus is one of the most satisfactory and curative operations in the field of surgery for congenital heart disease. 27 cases of isolated patent ductus arteriosus were operated from Jan. 1978 to July 1984 at the Department of Thoracic & Cardiovascular Surgery in Kyung-Hee University Hospital. Retrospective clinical analysis of these patients were: 1. Sex ratio, female: male, was 2:1. 2. Mean age at operation was 9.85\ulcorner.58 years. The youngest patient was a 23 month-old girl and the oldest one was a 24 year-old male. 3. More than half of the patients had less than 50 percentile of growth retardation. 4. Chief complaints of the patients were frequent URI [52%], dyspnea on exertion [33%], generalized weakness [22%], palpitation [7%], but 7 patients [26%] had no subjective symptoms. 5. Continuous machinery murmur could be heard at the 2nd or 3rd intercostal space on the left sternal border in 22 patients [81%]. The other S patients made systolic murmur with accentuation of the second heart sound and those were associated with pulmonary hypertension. 6. Radiologic findings of Chest P-A were cardiac enlargement in 15 patients [55%], enlargement of pulmonary conus and/or increasing density of pulmonary vascularity in 20 patients [74%]. 7. Electrocardiographic findings of the patients were within normal limit in 13 patients [48%], LVH in 4 patients [15%], biventricular hypertrophy in 3 patients [11%]. 8; echocardiogram was obtained from 11 patients. Ductus was directly visualized in 7 patients. Left atrial enlargement is the secondary change of left to right shunt, 10 patients had LA/Ao ratio more than 1.2. 9. Cardiac catheterization performed in 25 patients. The mean value of the results were:SO2[PA-RV]= 14.72\ulcorner6.01%, Qp/Qs=2.22\ulcorner.80, peak systolic pulmonary arterial pressure=48.28\ulcorner1.60 mmHg. 10. 26 patients were operated through the left posterolateral thoracotomy: closure of ductus by double ligation in 14 cases, triple ligation in 5 cases, and division with suture in 8 cases. One patient suffer from aneurysmal rupture of main pulmonary artery, endocarditis, hemopericardium was treated with cardiopulmonary bypass via median sternotomy and closure of ductus through the ruptured main pulmonary artery. 11.There was no death associated with the operation, but 3 cases were experienced with intraoperative rupture around the ductus resulting in massive bleeding. The other complications were transient hoarseness in one patient, atelectasis in left lower lobe in 3 patients, and postoperative systemic hypertension in 4 patients with unknown etiology. 12. Pulse pressure was reduced, 11.47+5.92 mmHg, postoperatively, as compare to preoperative status. 13. Intraoperative wedge lung biopsy from lingular segment for the evaluation of the pulmonary vascular disease was taken in S patients with severe pulmonary hypertension. The result was Heath-Edward grade I in one case, grade II in two cases, and grade III in two cases.

  • PDF

Usefulness of Acoustic Noise Reduction in Brain MRI Using Quiet-T2 (뇌 자기공명영상에서 Quiet-T2 기법을 이용한 소음감소의 유용성)

  • Lee, SeJy;Kim, Young-Keun
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.51-57
    • /
    • 2016
  • Acoustic noise during magnetic resonance imaging (MRI) is the main source for patient discomfort. we report our preliminary experience with this technique in neuroimaging with regard to subjective and objective noise levels and image quality. 60 patients(29 males, 31 females, average age of 60.1) underwent routine brain MRI with 3.0 Tesla (MAGNETOM Tim Trio; Siemens, Germany) system and 12-channel head coil. Q-$T_2$ and $T_2$ sequence were performed. Measurement of sound pressure levels (SPL) and heart rate on Q-$T_2$ and $T_2$ was performed respectively. Quantitative analysis was carried out by measuring the SNR, CNR, and SIR values of Q-$T_2$, $T_2$ and a statistical analysis was performed using independent sample T-test. Qualitative analysis was evaluated by the eyes for the overall quality image of Q-$T_2$ and $T_2$. A 5-point evaluation scale was used, including excellent(5), good(4), fair(3), poor(2), and unacceptable(1). The average noise and peak noise decreased by $15dB_A$ and $10dB_A$ on $T_2$ and Q-$T_2$ test. Also, the average value of heartbeat rate was lower in Q-$T_2$ for 120 seconds in each test, but there was no statistical significance. The quantitative analysis showed that there was no significant difference between CNR and SIR, and there was a significant difference (p<0.05) as SNR had a lower average value on Q-$T_2$. According to the qualitative analysis, the overall quality image of 59 case $T_2$ and Q-$T_2$ was evaluated as excellent at 5 points, and 1 case was evaluated as good at 4 points due to a motion artifact. Q-$T_2$ is a promising technique for acoustic noise reduction and improved patient comfort.