• 제목/요약/키워드: Peak Point

검색결과 1,043건 처리시간 0.025초

나선형태로 제작된 고온초전도 한류기의 특성해석 (Characterization of the Spiral Type Fault Current Limiters Using High-$T_c$ Superconducting Thin Films)

  • 정동철;박성진;강형곤;최효상;곽민환;임해용;황종선;최명호;추철원
    • 한국전기전자재료학회논문지
    • /
    • 제14권6호
    • /
    • pp.518-524
    • /
    • 2001
  • We report the current limiting properties of superconducting fault current limiters (SFCL). Our SFCL was patterned in a spiral type on a YB $a_2$C $u_3$$O_{7-x}$(YBCO) film deposited using rf sputtering techniques and was coated with a gold shunt layer in order to disperse the heat generated at hot spots in the YBCO film. Current increased up to 13.5 $A_{peak}$ at 60 Hz for the voltage of 13 $V_{peak}$, which is the minimum quench point, and increased up to 17.6 $A_{peak}$ at 60 Hz fo the voltage fo 141.4 $V_{peak}$. The quench completion time was 5 msec at 13 $V_{peak}$ and 4 msec at 141. $V_{peak}$ respectively. we think that this architecture using spiral-type SFCL can be useful for the protection of the power delivery systems from fault currents.s. currents.s.

  • PDF

Genetic Algorithm을 이용한 멀티 피크 빔의 최적방향탐색 (Sweet spot search of multi peak beam using Genetic Algorithm)

  • 황종우;임성진;엄기환
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2004년도 하계종합학술대회 논문집(1)
    • /
    • pp.301-304
    • /
    • 2004
  • In this paper, we propose a method to find the optimal direction of the multi beam between each station on the point-to-point link by genetic algorithm. In the proposed method, maximum value in optimal direction on each station is used as a fitness function. The beam of millimeter wave generates a lot of multi-peak because of much influence of noise. About each gene, we simulated this method using 16bit, 32bit, and 32bit split algorithm. 32bit split uses 16bit gene information. Each antenna makes 32bit gene information by adding gene information of two antennas having 16bit gene. Through the proposed method, we could have gotten a good output without 32bit gene information.

  • PDF

이종접합재 접합계면의 응력해석 (Stress Analysis of Brazed Interface in Dissimilar Materials by BEM)

  • 오환섭;김시현;김성재;양인수
    • 한국정밀공학회지
    • /
    • 제20권7호
    • /
    • pp.171-176
    • /
    • 2003
  • In this study, stress analysis using Boundary Element Method (BEM) was carried to investigate stress distribution in the brazing joint between a Hardmetal and a HSS. The two models were proposed to analyze the stress singularity in the interfaces of the brazing joint. The material type, thickness of the filler metal and the length of the vertical brazing adhesive are considered in the BEM analysis. As results, the peak point of the stress is founded to be in the lower interface of the brazed joint. It should be noted that the maximum stress of the peak point is being affected by the thickness and length of the brazing joint.

Relative Full-Energy Peak Detection Efficiency of Ge(Li) Detectors

  • Chung, Woon-Hyuk
    • Nuclear Engineering and Technology
    • /
    • 제7권3호
    • /
    • pp.223-226
    • /
    • 1975
  • ${\gamma}$-선의 full-energy Peak에 대한 상대적 검출효율을 Pair-Point method에 의해서 결정하였다. 이때 사용된 방사선원은 ${\gamma}$-선의 상대적 방출율이 이미 잘 측정된 $^{56}$ Co 이 됐다. 이 방법을 통해서, ${\gamma}$-선 에너지 범위 800-3500keV에 걸쳐, 반응치적 43.8cc, 32.6cc 및 6cc의 Ge(Li) 검출기들의 검출효율을 보정하였다.

  • PDF

이종재 브레이징 접합계면의 응력해석 (The Stress Analysis of Dissimilar Materials in Brazed Interface by BEM)

  • 오환섭;김시현;김성재
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 추계학술대회 논문집
    • /
    • pp.769-772
    • /
    • 1997
  • In this study, By employing two dimensional(2-D) Boundary Element Method(BEM) stress analysis was carried to investigate stress distributions on the brazing joint of a Hardmetal and a HSS. Two model was proposed to analyze stress singularity in brazed interface. The stress results from the BEM were considered influence of the kind of materials , thickness of filled metal and length of vertical brazing adhesive. From those obtained results , the peak point of stress was founded in the lower part of two interface was made by brazing. As the thickness and length changed, the maximum stress tended to change in the peak point.

  • PDF

공구날당 소재제거량이 각주형상 밀링가공물의 축방향 형상에 미치는 영향 (Effect of Material Removal per Tooth on the Axial Shape of Prismatically Milled Parts)

  • 김광희
    • 한국공작기계학회논문집
    • /
    • 제13권6호
    • /
    • pp.17-22
    • /
    • 2004
  • A study for investigating the effects of the cutting conditions (radial depth of cut feed per tooth) and the number of tooth on the side wall of prismatically milled workpiece is described. This study is available not only for understanding the geometrical characteristics of the end milled side wall but also for finding the optimal cutting conditions. In this work, the side wall geometry was characterized by the straightness and the location of maximum peak point. Through this study, it was revealed that the geometrical characteristics of the end milled side wall are strongly related to the material removal per tooth and the number of tooth.

개방관과 밀폐관의 열음향 효과에 관한 하모닉 특성 연구(2) - 2차, 3차 하모닉 (An Experimental Study on the Characteristics for Open-Tube and Closed-Tube Thermoacoustic Effects (2)- The 2nd, 3rd Harmonic)

  • 송규조;박종호;이성노
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제4권1호
    • /
    • pp.135-139
    • /
    • 2002
  • In this study, the experimental open-tube and close-tube thermoacoustic apparatuses were built. In order to determine the optimum length of resonant tube and the optimum length of stack, the resonant characteristics of thermoacoustic apparatuses were investigated, The length of resonant tube varies from 400mm to 850mm. The experimental frequency varies from 100Hz to 1000Hz. In case of the second and third harmonics, the maximum temperature difference of open-tube thermoacoustic apparatus is 53$^{\circ}C$ (resonator length: 400mm) and the maximum temperature difference of closed-tube thermoacoustic apparatus is 51$^{\circ}C$ (resonator length: 500mm). In the open-tube thermoacoustic apparatus, the peak efficiency point is about 2%, 55%, 69% in the resonant tube and in the closed-tube thermoacoustic apparatus, the peak efficiency point is about 2%, 41%, 50% in the resonant tube.

AE센서를 이용한 유중 코로나방전점 위치 및 주파수 영역 검출 (Location and Frequency Domain Detection of Corona Discharge Point in Oil Using AE Sensor)

  • 이상우;김성훈;김인식;김기채;박원주;이광식;이동인
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1999년도 학술대회논문집-국제 전기방전 및 플라즈마 심포지엄 Proceedings of 1999 KIIEE Annual Conference-International Symposium of Electrical Discharge and Plasma
    • /
    • pp.127-131
    • /
    • 1999
  • In this paper, using a wide-band AE sensor with the frequency range from 100[kHz], the frequency spectra of AE signals generated from the corona discharges of the needle-plane electrode was analyzed to determine the proper ultrasonic sensor. We also examined the relationship between the magnitude of corona discharge and the magnitude of AE signals in peak-to-peak value under the application of 60[Hz] AC high-voltage in oil. From these results, the main frequency spectra of AE signals emitted from the corona discharges of the needle-plane gap were found to be 130[kHz] by the fast fourier transform. The magnitude of AE signals was proportional to the magnitude of corona discharge and discharge current pulse with increasing the applied voltages. Also the detection of corona discharge point location by AE signals was found to be possible by using two sensors.

  • PDF

임피던스 심장기록법을 이용한 심장기능의 측정 (Measurement of Cardiac Function using Impedance Cardiography)

  • 김덕원;김정열
    • 대한의용생체공학회:의공학회지
    • /
    • 제9권1호
    • /
    • pp.109-116
    • /
    • 1988
  • In this paper, principles of impedance tenchinque and relationship between stroke volume and impedance change were theoretically explained. An impedance cardiograph was designed and constructed. Its reproducibility was verified by experiment. Until now, the peak point of dZ/dt waveform, first derivative of impedance change(${\Delta}$Z) , has been detected by software technique requiring considerable time to process. However in this paper its peak point was found using hardware for saving processing time. Useful cardiac parameters such as stroke volume and contractility of cardiac muscle were measured noninvasively. The reproducibility of the instrument was measured to be better(less than 10%) than that of clinical standard method such as thermodilution (more than 30%). Hence impedance cardiography was found to be better techique for monitoring stroke volume and myocardial contractility for pre and post operation, and pharmacological studies.

  • PDF

확률강우량을 이용한 AMC 조건에 따른 비점원 오염량의 변화 (Variation of Non-Point Source Pollution according to AMC Condition Using Probable Rainfall)

  • 안승섭
    • 한국농공학회지
    • /
    • 제42권3호
    • /
    • pp.76-88
    • /
    • 2000
  • AGNPS model is applied in this study to analyze the changes of non-point source pollutant according to AMC condition using probable rainfall. Probable rainfall of H-dam area by Gumber's extreme value distribution is computed through frequency analysis for each return period. 35 coarse grids are subdivided into 134 find grids of finite differential network to analyze peak flow soil loss quantity and nutrients of study area and the modified CN estimation equation shows good result about rainfall events-peak flow relationship. And as the consequence of estimation of soil loss quantity for each rainfall event soil loss quantity shows 120%-170% of actual soil loss quantity Regression analysis for the observed and calculated values of flow T-P AMC has an important effect on nutrients concentration of outflow and it if found that the excessive fertilization under AMC III condition may cause eutrophication by nutrients because the range of increase of outflow concentration appears relatively high.

  • PDF