• 제목/요약/키워드: Peak Frequency Deviation

검색결과 53건 처리시간 0.026초

Mw 5.5~6.5 지진동의 위상특성과 계속시간 및 PGA와의 관계 (Relationship between Phase Properties, Significant Duration and PGA from the Earthquake Records of Mw 5.5~6.5)

  • 최항;윤병익
    • 한국지진공학회논문집
    • /
    • 제23권1호
    • /
    • pp.55-70
    • /
    • 2019
  • The phase properties of ground acceleration records from Mw 5.5~6.5 earthquakes are analyzed. The interrelationships between phase properties and significant durations, as well as PGA, are clarified through both of theoretical and empirical approaches. The probabilistic characteristics of phase information is also discussed based on previous studies and it is shown that circular normal distribution is the most appropriate probability distribution for the phase angle and phase difference. Whereas those variates can be modeled by Gaussian random variables. From the survey results on the frequency dependency of the phase statistics, a simple model is introduced, which is possible to express the frequency dependency of phase information. It is also shown that the significant duration can be controlled by appropriately chosen standard deviation of phase difference for 4~8Hz frequency band and additional consideration of phase scattering in higher frequency band through a series of Monte Carlo simulations. The source of phase scattering effect is also pointed out and discussed.

계란 등급판정을 위한 파각란 자동 검사 시스템 (Automatic Eggshell Crack Detection System for Egg Grading)

  • 최완규;이강진;손재룡;강석원;이호영
    • Journal of Biosystems Engineering
    • /
    • 제33권5호
    • /
    • pp.348-354
    • /
    • 2008
  • Egg grading is determined by exterior and interior quality. Among the evaluation methods for the egg quality, a candling method is common to identify eggs with cracked shells and interior defects. But this method is time-consuming and laborious. In addition, practically, it is challenging to detect hairline and micro cracks. In this study, an on-line inspection system based on acoustic resonance frequency analysis was developed to detect hairline cracks on eggshells. A roller conveyor was used to transfer eggs along one lane to the impact position where each of eggs rotated by the roller was excited with an impact device at four different locations on the eggshell equator. The impact device was consisted of a plastic hammer and a rotary solenoid. The acoustic response of the egg to the impact was measured with a small condenser microphone at the same position as the impact device was installed. Two acoustic parameters, correlation coefficient for normalized power spectra and standard deviation of peak resonant frequencies, were used to detect cracked eggs. Intact eggs showed relatively high correlations among the four normalized power spectra and low standard deviations of the four peak resonant frequencies. On the other hand, cracked eggs showed low correlations and high standard deviations as compared to the intact. This method allowed a crack detection rate of 97.6%.

해석(解析)모델의 구조변수(構造變數) 변동(變動)이 동적응답에 미치는 영향(影響) (Effects of Structural Parameter Variations on Dynamic Responses)

  • 박형기;임부영
    • 대한토목학회논문집
    • /
    • 제13권3호
    • /
    • pp.59-67
    • /
    • 1993
  • 부분구조법(部分構造法)으로 프리스트레스드 콘크리트 원자로격납건물(原子爐格納建物)의 지진에 대한 확률위험도분석이나 내진 안전여유평가시 상부구조에 관한 입력자료(入力資料)가 되는 구조물(構造物)의 고유전동수와 구조물 상부에서의 최대가 속도값의 구조변수(構造變數)에 대한 변동성이 연구되었다. 본 연구는 먼저 구조모델의 고유진동수에 가장 큰 영향을 미치는 구조변수를 결정하기 위하여 각 구조변수(構造變數)의 상대적(相對的) 민감도(敏感度)를 분석(分析)하였고, 각 변수의 결정에 포함될 수 있는 불확실성(不確實性)의 정도를 고려하여 Monte Carlo 수치모형실험을 수행하였다. 최대 가속도값의 변화는 직접적분(直接積分)에 의한 시간이력곡선법으로 분석되었다. 연구결과로 첫번째모드의 고유 진동수와 건물 정상부의 최대가속도값은 각 변수중 탄생계수의 영향을 가장 크게 받으며, 결정론적 방법으로 구한 값과 비교할 때 확률론적 방법으로 구한 값(평균+표준편차)은 (+)12% 정도 변함을 알 수 있다. 또한 휨강성의 불확실성을 고려하면 동적응답은 (-)4%~(+)14% 정도 달라진다.

  • PDF

측두하악관절내장 환자의 진단분류에 따른 하악운동 특성의 분석 (Analysis of the Mandibular Movements in Patients with Internal Derangement of the Temporomandibular Joint According to Diagnostic Subgroups)

  • 김병연;기우천;최재갑
    • Journal of Oral Medicine and Pain
    • /
    • 제23권1호
    • /
    • pp.21-36
    • /
    • 1998
  • The purpose of this study was analyse the mandibular movements in patients with internal derangement of the temporomandibular joint according to diagnostic subgroups. The author classified patients with internal derangement of the temporomandibular joint into 4 diagnostic subgroups by means of the magnet resonance imagings, and evaluated the clinical signs and the mandibular movements with Mandibular Kinesiograph(MKG) in each subgroups. The mandibular movements, measured in this study, were the types of movement in frontal and sagittal plane, velocities in opening and closing movement, and the opening and closing movement, and the opening and closing velocity pattern. The data were compared between the 5 groups including the normal group. The results were as follows : 1. Pain was more frequently observed in the anterior disc displacement without reduction group than in the anterior disc displacement with reduction group. Sound of joint was more frequently observed in the anterior disc displacement with reduction group, and limitation of mandibular opening movement was more frequently observed in the anterior disc displacement without reduction group. Duration of the anterior disc displacement without reduction group was significantly short compared to that of the anterior disc displacement with reduction group, and duration of the unilateral anterior disc displacement without reduction group was shortest in the experimental group. The frequency of Angle's classifications had not significant correlations between the experimental groups. 2. Active and passive range of the opening movement, maximum protrusive movement, maximum lateral movement toward left side were significantly decreased in the experimental groups compared to the control group, but there was no significant difference in the range of the maximum lateral movement toward right side between the control and experiment groups. In unilateral anterior disc displacement without reduction group, the range of maximum lateral movement toward unaffected side was no significant difference in the range of the maximum lateral movement between toward affected side and toward unaffected side. 3. Maximum opening velocity, maximum closing velocity, average opening velocity, average closing velocity and maximum velocity of terminal tooth contact were significantly decreased in the experimental groups compared to control group. There was no significant difference in maximum opening velocity and maximum velocity of Terminal tooth contact between the subgroups of the experimental group each other, but there was significant difference in maximum closing velocity, average opening velocity and average closing velocity between the subgroups each other. 4. In the frontal plane of the MKG, the frequency of complex deviation type(F-2)pattern was significantly increased in the anterior disc displacement with out reduction group compared to the anterior disc displacement with reduction group and the control group. In the sagittal plane, the frequency of coincident type(S-1)was decreased in the same group. 5. In the maximum opening velocity pattern, the frequency of no-peak type (OV-3)in the unilateral anterior disc displacement with reduction group was significantly increased compared to the control group. The frequency of 1-peak type (OV-1) and 2-peak type (OV-2) was decreased in the anterior disc displacement with out reduction group, but the frequency of no-peak type (OV-3)was increased in the same group. In the maximum closing velocity pattern, the frequency of no-peak type (CV-3) was significantly increased in the anterior disc displacement without reduction group. Compared to the anterior disc displacement with reduction group and the control group. The frequency of 1-peak type (CV-1) and 2-peak type (CV-2) in the anterior disc displacement with reduction group was decreased than that in the control group.

  • PDF

Dynamic Modulus of Three-Layer Boards with Different Furnish and Shelling Ratio

  • Rofii, Muhammad Navis;Prayitno, Tibertius Agus;Suzuki, Shigehiko
    • Journal of the Korean Wood Science and Technology
    • /
    • 제44권2호
    • /
    • pp.274-282
    • /
    • 2016
  • This aims of this study were to investigate the relationship between non-destructive evaluation (NDE) and actual bending properties of particleboard, and to predict the bending properties of three-layer particleboard. Three kinds of raw materials, i.e. Hinoki (Chamaecyparis obtusa Endl.) strand, knife-milled Douglas-fir (Pseudotsuga manziesii (Mirb) Franco), and hammer-milled matoa (Pometia spp.) obtained from wooden industry, were utilized as furnish for experimental panel with methylene diphenyl diisocyanate (MDI) resin as binder. The NDE test was conducted by hit sounds using an FFT analyzer according to the spectrum peak of wave frequency, while the static bending test was conducted according to JIS A-5908. The results reveal that the dynamic Young's modulus as an NDE test has a potential for being used to predict the elastic bending of particleboards by a specific equation for adjusting its proper values. The values of NDE and static test are significantly different with a deviation range at 3-20%. The bending stiffness of three-layer particleboards manufactured from different wood species is predictable by observing the bending stiffness of two elements based on the thickness of its layers. The predicted values of bending stiffness and static test are significantly different with a deviation range at 5-24%.

The loss coefficient for fluctuating flow through a dominant opening in a building

  • Xu, Haiwei;Yu, Shice;Lou, Wenjuan
    • Wind and Structures
    • /
    • 제24권1호
    • /
    • pp.79-93
    • /
    • 2017
  • Wind-induced fluctuating internal pressures in a building with a dominant opening can be described by a second-order non-linear differential equation. However, the accuracy and efficiency of the governing equation in predicting internal pressure fluctuations depend upon two ill-defined parameters: inertial coefficient $C_I$ and loss coefficient $C_L$, since $C_I$ determines the un-damped oscillation frequency of an air slug at the opening, while $C_L$ controls the decay ratio of the fluctuating internal pressure. This study particularly focused on the value of loss coefficient and its influence factors including: opening configuration and location, internal volumes, as well as wind speed and approaching flow turbulence. A simplified formula was presented to predict loss coefficient, therefore an approximate relationship between the standard deviation of internal and external pressures can be estimated using Vickery's approach. The study shows that the loss coefficient governs the peak response of the internal pressure spectrum which, in turn, will directly influence the standard deviation of the fluctuating internal pressure. The approaching flow characteristic and opening location have a remarkable effect on the parameter $C_L$.

반폐쇄성도훈련이 기능적 실성증 환자의 음성 개선에 미치는 효과 (Effects of Semi-Occluded Vocal Tract Exercise in Patients with Functional Aphonia)

  • 채혜림;김지성;이동욱;최성희
    • 대한후두음성언어의학회지
    • /
    • 제30권1호
    • /
    • pp.48-52
    • /
    • 2019
  • Background and Objectives : Functional aphonia is characterized by incomplete closure of the vocal folds. Semi-occluded vocal tract exercise (SOVTE) allows smoothly vocal folds collision without damage to the vocal folds tissues to produce normal vocal intensity. The purpose of this study is to report the effect of SOVTE in patients with functional aphonia. Materials and Method : Seven patients diagnosed with functional aphonia were treated with 1-3 voice therapy sessions using voiced lip-trill, humming, Lax Vox in SOVTE. To assess the effectiveness of semi-occluded vocal tract exercise, cepstral analysis and auditory perceptual assessment were performed before and after voice therapy. Results : F0 (fundamental frequency), CPP (cepstral peak prominence) and L/H ratio (low/high spectral ratio) were significantly increased, while CPP Standard deviation, L/H ratio Standard deviation were decreased. In addition, 'Grade', 'Breathiness' and 'Asthenia' were significantly decreased in the GRBAS scale after SOVTE (p<0.05). Conclusion : In our study, SOVTE seemed to be effective to elicit voice quickly and promote vocal folds vibration without muscular effort in patients with functional aphonia.

A Two-Point Modulation Spread-Spectrum Clock Generator With FIR-Embedded Binary Phase Detection and 1-Bit High-Order ΔΣ Modulation

  • Xu, Ni;Shen, Yiyu;Lv, Sitao;Liu, Han;Rhee, Woogeun;Wang, Zhihua
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제16권4호
    • /
    • pp.425-435
    • /
    • 2016
  • This paper describes a spread-spectrum clock generation method by utilizing a ${\Delta}{\Sigma}$ digital PLL (DPLL) which is solely based on binary phase detection and does not require a linear time-to-digital converter (TDC) or other linear digital-to-time converter (DTC) circuitry. A 1-bit high-order ${\Delta}{\Sigma}$ modulator and a hybrid finite-impulse response (FIR) filter are employed to mitigate the phase-folding problem caused by the nonlinearity of the bang-bang phase detector (BBPD). The ${\Delta}{\Sigma}$ DPLL employs a two-point modulation technique to further enhance linearity at the turning point of a triangular modulation profile. We also show that the two-point modulation is useful for the BBPLL to improve the spread-spectrum performance by suppressing the frequency deviation at the input of the BBPD, thus reducing the peak phase deviation. Based on the proposed architecture, a 3.2 GHz spread-spectrum clock generator (SSCG) is implemented in 65 nm CMOS. Experimental results show that the proposed SSCG achieves peak power reductions of 18.5 dB and 11 dB with 10 kHz and 100 kHz resolution bandwidths respectively, consuming 6.34 mW from a 1 V supply.

Ancillary Service Requirement Assessment Indices for the Load Frequency Control in a Restructured Power System with Redox Flow Batteries

  • Chandrasekar, K.;Paramasivam, B.;Chidambaram, I.A.
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권6호
    • /
    • pp.1535-1547
    • /
    • 2016
  • This paper proposes various design procedures for computing Power System Ancillary Service Requirement Assessment Indices (PSASRAI) for a Two-Area Thermal Reheat Interconnected Power System (TATRIPS) in a restructured environment. In an interconnected power system, a sudden load perturbation in any area causes the deviation of frequencies of all the areas and also in the tie-line powers. This has to be corrected to ensure the generation and distribution of electric power companies to ensure good quality. A simple Proportional and Integral (PI) controllers have wide usages in controlling the Load Frequency Control (LFC) problems. So the design of the PI controller gains for the restructured power system are obtained using Bacterial Foraging Optimization (BFO) algorithm. From the simulation results, the PSASRAI are calculated based on the settling time and peak over shoot concept of control input deviations of each area for different possible transactions. These Indices are useful for system operator to prepare the power system restoration plans. Moreover, the LFC loop coordinated with Redox Flow Batteries (RFB) has greatly improved the dynamic response and it reduces the control input requirements and to ensure improved PSASRAI, thereby improving the system reliability.

확산적 흐림의 투과율이 시력과 대비감도에 미치는 영향 (Effects of Transmittance of Diffusive Blur on Visual Acuity and Contrast Sensitivity)

  • 양석준;최은정
    • 한국안광학회지
    • /
    • 제20권3호
    • /
    • pp.355-362
    • /
    • 2015
  • 목적: 확산적 흐림의 투과율이 시력과 대비감도에 미치는 영향에 대하여 알아보았다. 방법: 평균연령 $22.83{\pm}0.50$세의 대학생 30명(남 13명, 여 17명)을 대상으로 Optec$^{(R)}$ 6500으로 시력과 대비감도를 측정하였다. 확산적 흐림의 도구로 백내장 시뮬레이터용 확산필름을 사용하였고, 백내장의 진행 정도나 안개의 농도가 반영될 수 있도록 확산적 흐림의 투과율을 변화시키면서 측정하였다. 결과: 시력과 확산적 흐림의 투과율은 비례식 $VA(T)=1.84{\times}10^{-2}T-0.65$으로 맞춤되었다. 대비감도는 모든 공간주파수에서 감소하였는데, 고공간주파수 대역에서의 대비감도가 더 큰 영향을 받아 정상범위를 먼저 벗어났고 대비감도의 정점은 저공간주파수 방향으로 이동하였다. 대비감도함수들의 교차점으로부터 대비감도가 정상범위를 벗어나는 확산적 흐림의 투과율 및 정점공간주파수의 이동을 산출한 결과, 투과율이 약 78.70%이 되면 대비감도의 정점이 6 cpd에서 3 cpd로 이동하는 것으로, 그리고 약 69.71%이 되면 모든 공간주파수에서의 대비감도가 정상범위를 벗어나는 것으로 평가되었다. 결론: 확산적 흐림의 투과율의 감소는 시력의 저하와 더불어 대비감도의 감소, 정상범위의 이탈 및 정점대비감도 이동 등을 유발시켜 시각적 불편함을 일으킨다는 점에서 백내장이나 안개 운전 시에는 더 많은 주의가 요구된다.