• 제목/요약/키워드: Peak Discharge Current

검색결과 123건 처리시간 0.024초

방사선에 조사된 EPR 의 전기적 특성에 관한 연구 (A Study on Electrical properties of EPR by Irradiated by X-rays)

  • 이성일;김귀열;이호식;이희갑
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 추계학술대회 논문집 Vol.15
    • /
    • pp.565-568
    • /
    • 2002
  • The value of charge current, discharge current, $\varepsilon_r$' $\varepsilon_r"$, residual voltage was measured inorder to investigate electric properties in Ethylene Prophylene Rubber for is irradiated $CO^{60}\gamma$ ray 0-38.1 Mrad. The value of charge current and the discharging current of the EPR is influenced by $CO^{60}-{\gamma}$-irradiation dose The charging current and the discharging current of EPR increase, depending on the ratio of degradation. As the irradiation dose is increased, the peak of residual voltage moves to the slorter time. The properties specific electric constant due to time variation was appeared dispersion by plentiful $CO^{60}-{\gamma}$-irradiation dose. The increase of peak in $\varepsilon_r"$ is attrib uted to the irratiation dose almost proportionally.

  • PDF

자동차 헤드라이트용 전자식 안정기 개발 (Development of Electronic Ballast for Automotive High Intensity Discharge Lamp)

  • 박종연;배수호;조계현
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 하계종합학술대회 논문집(5)
    • /
    • pp.319-322
    • /
    • 2002
  • In this Paper, we suggested the Half-Bridge inverter for the automotive HID electronic ballast. electronic ballast for automotive HID lamp should be supplied by low-frequency square wave avoiding the acoustic resonance(11kHz ∼ 825kHz). When the HID lamp is hot state, the electronic ballast should supply the sufficient current for a few milli-second to the lamp at the re-strike ignition state. that is called take-over current. We have introduced the new take-over current control method that could have reduced the peak current and supplied the sufficient take-over current.

  • PDF

트랜지스터 부착 RC 방전회로의 마이크로 방전가공 특성 (Characteristics of RC circuit with Transistor in Micro-EDM)

  • 조필주;이상민;최덕기;주종남
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.235-240
    • /
    • 2002
  • In micro-EBM, it is well blown that RC circuit is suitable for discharge circuit because of its low pulse width and relatively high peak current. To increase machining speed without changing unit discharge energy, charge resistance should be decreased. But, if very low, continuous (or normal) arc discharge occurs, then increases electrode wear and reduces machining speed remarkably. In this paper, RC circuit with transistor is used to micro-EDM. Experimental results show that RC circuit with transistor can cut off continuous (or normal) arc discharge effectively if duty factor and switching period of transistor are set up optimally. Through experiments with varying charge resistance, it can be known that RC circuit with transistor has about two times faster machining speed than that of RC circuit. Especially, it has prominent rise-effect of machining speed in low unit discharge energy, so that a high-quality and high-speed micro-EDM can be realized through RC circuit with transistor.

  • PDF

인가 전압의 변화에 따른 FFL(Flat Fluorescent Lamp)의 방전특성 (Discharge characteristics of FFL as applied voltage variation)

  • 윤성현;박철현;조민정;임민수;권순석;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 추계학술대회 논문집
    • /
    • pp.379-382
    • /
    • 2000
  • The characteristics of Xe discharge lamp(Mercuryless lamp) are described in this paper. In this paper, FFL is operated by sine wave and pulsed source. We apply V-Q Lissajous' figure for the discharge measurements of FFL which has the electrodes covered with dielectric. When FFL is operated by sine wave source, the characteristics are similar to DBD(Dielectric Barrier Discharge) and SD(Silent Discharge). And we compared the characteristics of FFL which is operated with sine wave and pulsed discharge by using V-Q Lissajous' figure method. When FFL is operated with pulsed, the discharge current flows after the applied voltage is risen. As the duty ratio increases the electric field becomes strong and much more xenon ions are produced. And the number of metastable xenon atoms seem to increase, therefore, the phosphor radiation after the cut off of voltage increases compared with the first peak of radiation. Consequently, the 172㎚ radiation becomes strong as the duty ratio increases.

  • PDF

EPR의 전기특성에 미치는 방사선의 영향 (Effect of the Co$^{60}$ -Rays due to Electric properties of EPR-)

  • 이성일
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2002년도 추계학술대회
    • /
    • pp.253-259
    • /
    • 2002
  • The value of charge currnet, discharge current, ${\varepsilon}r^'$,${\varepsilon}r^{'}$ residual voltage was measured inorder to investigate electric properties in Ethylene Prophylene Rubber for is irradiated C0$^{60}$$\gamma$ ray 0~38.1 Mrad. The value of charge current and the discharging current of the EPR is influenced by C0$^{60}$-$\gamma$- irradiation dose. The charging current and the discharging current of EPR increas, depending on the ratio of degradation. As the irradiatin dose is increased, the peak of residual voltage moves to the slorter time. The properties specific electric constant due to time variation was appeared dispersion by plentiful C0$^{60}$$\gamma$- irradiation dose. The increase of peak in ${\varepsilon}r^{'}$ is attrib uted to the irratiation dose almost proportionally.

  • PDF

고체절연체의 내부결함에 따른 부분방전 특성과 패턴분류 (Properties of PD and Classification of Defect Patterns in Solid Insulation)

  • 강성화;박영국;이광우;김완수;이용희;임기조
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 D
    • /
    • pp.1624-1626
    • /
    • 1999
  • PD in defect of solid insulation system is very harmful since It often leads to deterioration of insulation by the combined action of the discharge ions bombarding the surface and the action of chemical compounds that are formed by the discharge. PD can indicate incipient failure, so it has been used to determine degradation of insulation. In this paper. we investigated PD in defects of solid insulation by using statical method and classified PD patterns with surface discharge, electrical tree and void discharge by using Kohonen network. we used peak charge, average discharge power, average discharge current, repetition rate, skewness, kurtosis, QN of the max pulse height vs. repetition rate $H_q(n)$ for analysis and classification.

  • PDF

트랜지스터 부착 RC 방전회로의 마이크로 방전가공 특성 (Characteristics of RC Circuit with Transistors in Micro-EDM)

  • 조필주;이상민;최덕기;주종남
    • 한국정밀공학회지
    • /
    • 제21권12호
    • /
    • pp.44-51
    • /
    • 2004
  • In a micro-EDM, it is well known that an RC circuit is suitable as a discharge circuit because of its low pulse width and relatively high peak current. To increase machining speed without changing unit discharge energy, charge resistance should be decreased. But, when the resistance is very low, continuous (or normal) arc discharge occurs, electrode wear increases and machining speed is reduced remarkably. In this paper, an RC circuit with transistors is used in a micro-EDM. Experimental results show that the RC circuit with transistors can cut off a continuous (o. normal) arc discharge effectively if the duty factor and switching period of the transistor are set up optimally. Through experiments with varying charge resistances, it is shown that the RC circuit with transistors has about two times faster machining speed than that of an RC circuit.

The Method to Improve the Luminance Efficiency by Auxiliary Capacitor in AC PDP

  • Lee, Ji-Hoon;Lee, Don-Kyu;Choi, Joon-Young;Ok, Jung-Woo;Kim, Dong-Hyun;Lee, Ho-Jun;Park, Chung-Hoo;Lee, Hae-June
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2006년도 6th International Meeting on Information Display
    • /
    • pp.913-916
    • /
    • 2006
  • The improvement of luminous efficacy is one of the major issues in PDP industry. In this work, we propose the new driving method for high efficiency AC-PDP and analyze its discharge characteristics. The suggested method can control the effective capacitance of panel by external auxiliary capacitor. External capacitor induces reduction of gap voltage proportional to the panel current, this in turn modifies the transient behaviour of discharge. The peak current level is reduced and the discharge duration is increased. As a result of these modifications, the luminous efficacy is enhanced by about 200% compared with the conventional driving method

  • PDF

액상 반응에 의해 합성한 리튬코발트산화물을 이용한 Lithium ion 2차전지의 충방전 특성 (Charge-discharge Behaviour of Lithium Ion Secondary Battery Using LiCo$O_2$ Synthesized by a Solution Phase Reaction)

  • 김상필;조정수;박정후;윤문수;심윤보
    • 한국전기전자재료학회논문지
    • /
    • 제11권11호
    • /
    • pp.1049-1054
    • /
    • 1998
  • The LiCo$O_2$ powder was synthesized by a solution phase reaction. This shows a high (003) peak intensity and low (104) or (101) peak intensities in X-ray diffraction spectra. The LiCo$O_2$/Li cell shows an initial discharge capacity of 102.9mAh/g and an average discharge potential or 3.877V at a current density of 50mA/g between 3.0~4.2V. The peaks of dQ/dV plot are associated with Li ion intercalation/deintercalation reaction. To evaluate the cycleability of an actual battery system, cylindrical lithium ion cell was manufactured using graphitized MPCF anode and LiCoO$_2$ cathode. After 100th cycle, this cel maintains 80% capacity of 10th cycle value. The LiCoO$_2$/MPCF cell has a high discharge voltage of 3.6~3.7V and a good cycle life performance on cycling between 4.2~2.7V.

  • PDF

광대역 AE 센서에 의한 유중코로나의 초음파 특성 (Detection of Ultrasonic Characteristics of Oil Corona by Wide-Band AE Sensor)

  • 김인식;이상우;이동인;이광식;김이국
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제49권1호
    • /
    • pp.44-51
    • /
    • 2000
  • In this paper, using a wide-band AE sensor with the frequency range from 100[kHz] to 1.5[kHz], the frequency spectra of AE signals generated from the corona discharges of the needle-plane gap and from the partial discharges of an epoxy void were analyzed to determine the proper ultrasonic sensor with optimum frequency range according to the patterns of corona discharges. We also examined the propagation characteristics of AE signals in oil and the relationship between the magnitude of corona discharge and the magnitude of AE signals in peak-to-peak value under the application of 60[Hz] ac high-voltage. From these results, the main frequency spectra of AE signals emitted from the corona discharges of the needle-plane gap were about 130[kHz] by the fast fourier transform, but the main frequency spectra appeared to be 230[kHz] in the partial discharges of an epoxy void. The magnitude of AE signals was proportional to the magnitude of corona discharge and discharge current pulse with increasing the applied voltages.

  • PDF