• Title/Summary/Keyword: Peak Discharge

Search Result 624, Processing Time 0.028 seconds

Molybdeum Oxide Film Preparation by a Magnetic Null Discharge Sputtering and its Application (자기 중성방전 스퍼터링에 의한 산화몰리브덴 박막의 제작 및 그 응용)

  • Kim, Doo-Hwan;Park, Cha-Soo;Sung, Youl-Moon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.1
    • /
    • pp.169-175
    • /
    • 2009
  • In this experiment molybdeum oxide($MoO_3$) films were prepared by a magnetic null discharge(MND) sputtering system and fundamental properties by XRD, XPS and SEM analysis were investigated. The initial and mean insulation resistance of the same with $MoO_3$ film were about 1.4[$M{\Omega}$] and 800[$k{\Omega}$] under the condition of applied voltage of 400[V]. The preferred orientation in the films changed from(100) to (210) with substrate temperature. Two XPS peaks of the $MoO_3$ photoelectron were detected at the binding energies of 228.9[eV] and 232.4[eV], while the binding energy of the O1s peak was 532.6[eV]. The substrate temperature and reactivity gives large effects to the structure and growth of the film and system is also very useful for performing the uniform reactive deposition. It can be found from the result of a $MoO_3$ film deposition that the system is very useful for performing the uniform reactive sputtering.

A Parasol-type Grid-connected Solar Power Generation System for Utilization of New and Renewable Energy (신.재생에너지 활용을 위한 연계 계통형 그늘막 태양광 발전 시스템)

  • Lee, Jae-Min;Lee, Chang-Sung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.2
    • /
    • pp.230-236
    • /
    • 2009
  • In this paper, in order to utilize new and renewable energy a grid-connected parasol-type solar power generation system is presented. The proposed power system combining with commercial electric power system is designed to meet the need fur maximum power consumption and parasols for the people staying at beach during hot summer. Solar electric power can be charged in rechargeable batteries during day time and used to provide charged electric power to loads like lamps and fans during night time, A battery charge-discharge controller is required for the good performance of batteries to be charged. The presented battery controller is designed based on high performance microprocessor for precise charge-discharge operations. An alarm circuit to give notice of battery exchange time and other convenient functions are installed in the system. We implemented the proposed solar power generation system at East Sea beach during peak summer season to verify its productivity and performance by experiments.

Inference of natural flood frequency for the region affected by dams in Nam Han River (남한강 유역 댐 영향 지역의 기본홍수량 추론)

  • Kim, Nam Won;Lee, Jeong Eun;Lee, Jeongwoo
    • Journal of Korea Water Resources Association
    • /
    • v.49 no.7
    • /
    • pp.599-606
    • /
    • 2016
  • The objective of this study is to estimate the unregulated flood frequency from Chungju dam to Yangpyung gauging station for the region affected by dams based on the peak discharges simulated by storage function routing model. From the flood frequency analyses, the quantiles for the unregulated flood frequency at 6 sites have similar pattern to each other, and their averaged quantile almost matched to the result from the regional flood frequency analysis. The quantile and annual mean discharge for the unregulated flood frequency for the downstream of Chungju dam show the similar behaviour to those for the upstream area. While the quantile and the annual mean discharge for the regulated flood frequency are significantly different from those for the unregulated flood frequency. In particular, the qunatile shows severe difference as the return period increases, and the annual mean discharge has a tendency to approach to the natural flood as the distance from dam increases.

The Electrochemical Characterization of$LiMn_{2-y}M_yO_4$ Cathode Material - II. Charge and Discharge Property and Cyclic Voltametry of $LiMn_{2-y}M_yO_4$ (M=Zn, Mg) ($LiMn_{2-y}M_yO_4$ 정극 활물질의 전기화학적 특성 - II. $LiMn_{2-y}M_yO_4$ (M=Zn, Mg)의 충방전 및 순환전위전류 특성)

  • 정인성;김종욱;구할본;김형곤;손명모;박복기
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.4
    • /
    • pp.316-322
    • /
    • 2001
  • Cathode materials $LiMn_{2-y}$$M_{y}$ $O_4$(M=Zn and Mg) were obtained by reacting the mixture of LiOH.$H_2O$, Mn $O_2$ and MgO ar ZnO at 80$0^{\circ}C$ for 36h in an air atmosphere. These materials showed an extended cycle life in lithium-anode cells working at room temperatue in a 3.0 to 4.3V potential window. Among these materials, LiM $n_{1.9}$M $g_{0.1}$ $O_4$ showed the best cycle performance in terms of the capacity and cycle life. The discharge capacities of the cathode for the Li/LiM $n_{1.9}$ $M_{0.1}$ $O_4$ cell at the 1st cycle and at the 70th cycle were about 120 and 105mAh/g, respectively. This cell capacity is retained by 88% after 70th cycle. In cyclic voltammetry measurement, all cells revealed tow oxidation peaks and reduction peaks. However, Li/$LiMn_{2-y}$$M_{y}$ $O_4$ cell substituted with Zn and Mg showed new reaction peak during reduction reaction.eaction.ion.ion.

  • PDF

Gas Temperature Measurement in Supersonic Flows by N2+ Emission Spectroscopy (질소 이온 발광 분광법을 이용한 초음속 유동의 기체 온도 측정)

  • Shin, Ji-Chul
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.3
    • /
    • pp.245-250
    • /
    • 2010
  • The procedure for estimating the gas (rotational) temperature of an air discharge in supersonic flows is presented in detail. Since direct measurement of the temperature in a supersonic flow is difficult, a nonintrusive measurement was performed by optical emission spectroscopy based on the emission spectra of nitrogen molecular ions. A detailed explanation, including the equations for emission line intensity, is presented in order to understand the structure of the emission spectra of nitrogen molecular ions. Using the obtained representation for emission spectrum, a synthetic spectrum of the first negative system of $N_2^+$ is obtained, and it is compared with the experimentally measured spectrum. Within a relative error of approximately 6.8% for the overall band spectra, the synthetic and measured spectra agree well. In the case of a 25-mA DC air discharge in a supersonic (Mach 3) flow, the gas temperature profile shows an approximately linear variation and a peak temperature of approximately 350 K.

Analysis of Runoff Sensitivity for Initial Soil Condition in Distributed Model (초기토양조건에 대한 분포형모형 유출민감도 분석)

  • Park, Jin Hyeog;Hur, Young Teck
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.4B
    • /
    • pp.375-381
    • /
    • 2008
  • In this research, a physics based grid-multi layer distributed flood runoff model was developed to analyze discharge for the Namgang Dam Watershed ($2,293km^2$) and applied for sensitivity analysis for estimation of parameters, mainly initial soil moisture condition and saturate infiltration coefficient, which have a strong influence on discharge. Capability of the model was evaluated using VER and QER from the results of rainfall-runoff analysis and showed enhanced results of 6% compared to parameters before calibration. As the result with the sensitivity analysis of parameters, the part of the most influence on the runoff was the infiltration coefficient and ratio of layer partition. The total discharge and peak time showed comparatively precise runoff results without the initial calibration of the parameters.

Study on Design Capacity of Stormwater Pipe and Pumping Station considering Peak Rainfall Intensity (첨두강우강도를 고려한 우수관로 및 빗물펌프장의 설계용량 검토)

  • Chung, Gunhui;Sim, Kyu Bum;Kim, Eung Seok
    • Journal of Korea Water Resources Association
    • /
    • v.47 no.9
    • /
    • pp.777-787
    • /
    • 2014
  • Stormwater pipe systems are most commonly used to discharge rainwater from the urban catchment covered by the impervious area. To design stormwater pipe and rainwater pumping station, frequency analysis is implemented using historical rainfall and the design rainfall is timely distributed using theoretical shape such as Huff distribution. This method cannot consider the rainfall intensity variation caused by climate change which is type of uncertainty. Therefore, in this study, runoff from Gasan1 stormwater pumping stations catchment is calculated using design rainfall distributed by the 2nd quartile distribution method and the historical rainfall events. From the analysis, the nodal flooding in the urban catchment is likely caused by the high peak rainfall event rather than the large amount of rainfall. The linear regression analysis is implemented. As a result, when several storms have the same amount of rainfall, the nodal flooding in the stormwater pipe systems could be caused by the high peak of storm events. Since as the storm duration become short, the peak rainfall become high, the nodal flooding likely become severe with the short storm duration. The uncertainty in the peak data of design rainfall is analyzed and this uncertainty has to be consider in the stormwater pipe design process.

Relationships on Magnitude and Frequency of Freshwater Discharge and Rainfall in the Altered Yeongsan Estuary (영산강 하구의 방류와 강우의 규모 및 빈도 상관성 분석)

  • Rhew, Ho-Sang;Lee, Guan-Hong
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.16 no.4
    • /
    • pp.223-237
    • /
    • 2011
  • The intermittent freshwater discharge has an critical influence upon the biophysical environments and the ecosystems of the Yeongsan Estuary where the estuary dam altered the continuous mixing of saltwater and freshwater. Though freshwater discharge is controlled by human, the extreme events are mainly driven by the heavy rainfall in the river basin, and provide various impacts, depending on its magnitude and frequency. This research aims to evaluate the magnitude and frequency of extreme freshwater discharges, and to establish the magnitude-frequency relationships between basin-wide rainfall and freshwater inflow. Daily discharge and daily basin-averaged rainfall from Jan 1, 1997 to Aug 31, 2010 were used to determine the relations between discharge and rainfall. Consecutive daily discharges were grouped into independent events using well-defined event-separation algorithm. Partial duration series were extracted to obtain the proper probability distribution function for extreme discharges and corresponding rainfall events. Extreme discharge events over the threshold 133,656,000 $m^3$ count up to 46 for 13.7y years, following the Weibull distribution with k=1.4. The 3-day accumulated rain-falls which occurred one day before peak discharges (1day-before-3day -sum rainfall), are determined as a control variable for discharge, because their magnitude is best correlated with that of the extreme discharge events. The minimum value of the corresponding 1day-before-3day-sum rainfall, 50.98mm is initially set to a threshold for the selection of discharge-inducing rainfall cases. The number of 1day-before-3day-sum rainfall groups after selection, however, exceeds that of the extreme discharge events. The canonical discriminant analysis indicates that water level over target level (-1.35 m EL.) can be useful to divide the 1day-before-3day-sum rainfall groups into discharge-induced and non-discharge ones. It also shows that the newly-set threshold, 104mm, can just separate these two cases without errors. The magnitude-frequency relationships between rainfall and discharge are established with the newly-selected lday-before-3day-sum rainfalls: $D=1.111{\times}10^8+1.677{\times}10^6{\overline{r_{3day}}$, (${\overline{r_{3day}}{\geqq}104$, $R^2=0.459$), $T_d=1.326T^{0.683}_{r3}$, $T_d=0.117{\exp}[0.0155{\overline{r_{3day}}]$, where D is the quantity of discharge, ${\overline{r_{3day}}$ the 1day-before-3day-sum rainfall, $T_{r3}$ and $T_d$, are respectively return periods of 1day-before-3day-sum rainfall and freshwater discharge. These relations provide the framework to evaluate the effect of freshwater discharge on estuarine flow structure, water quality, responses of ecosystems from the perspective of magnitude and frequency.

Change of Electrochemical Characteristics Due to the Fe Doping in Lithium Manganese Oxide Electrode

  • Ju Jeh Beck;Kang Tae Young;Cho Sung Jin;Sohn Tae Won
    • Journal of the Korean Electrochemical Society
    • /
    • v.7 no.3
    • /
    • pp.131-137
    • /
    • 2004
  • Sol-gel method which provides better electrochemical and physiochemical properties compared to the solid-state method was used to synthesize the material of $LiFe_yMn_{2-y}O_4$. Fe was substituted to increase the structural stability so that the effects of the substitution amount and sintering temperature were analyzed. XRD was used for the structural analysis of produced material, which in turn, showed the same cubic spinel structure as $LiMn_2O_4$ despite the substitution of $Fe^{3+}$. During the synthesis of $LiFe_yMn_{2-y}O_4$, as the sintering temperature and the doping amount of Fe(y=0.05, 0.1, 0.2)were increased, grain growth proceeded which in turn, showed a high crystalline and a large grain size, certain morphology with narrow specific surface area and large pore volume distribution was observed. In order to examine the ability for the practical use of the battery, charge-discharge tests were undertaken. When the substitution amount of $Fe^{3+}\;into\;LiMn_2O_4$ increased, the initial discharge capacity showed a tendency to decrease within the region of $3.0\~4.2V$ but when charge-discharge processes were repeated, other capacity maintenance properties turned out to be outstanding. In addition, when the sintering temperature was $800\~850^{\circ}C$, the initial capacity was small but showed very stable cycle performance. According to EVS(electrochemical voltage spectroscopy) test, $LiFe_yMn_{2-y}O_4(y=0,\;0.05,\;0.1,\;0.2)$ showed two plateau region and the typical peaks of manganese spinel structure when the substitution amount of $Fe^{3+}$ increased, the peak value at about 4.15V during the charge-discharge process showed a tendency to decrease. From the previous results, the local distortion due to the biphase within the region near 4.15V during the lithium extraction gave a phase transition to a more suitable single phase. When the transition was derived, the discharge capacity decreased. However the cycle performance showed an outstanding result.

Development and Accuracy Analysis of the Discharge-Supply System to Generate Hydrographs for Unsteady Flow in the Open Channel (개수로에서의 부정류 수문곡선 재현을 위한 유량공급장치의 개발 및 정확도 분석)

  • Kim, Seo-Jun;Kim, Sang-Hyuk;Yoon, Byung-Man;Ji, Un
    • Journal of Korea Water Resources Association
    • /
    • v.45 no.8
    • /
    • pp.783-794
    • /
    • 2012
  • The analysis for unsteady flow is necessary to design the hydraulic structures affected by water level and discharge changes through time. The numerical model has been generally used for unsteady flow analysis, however it is difficult to acquire field data to calibrate and validate the numerical model. Even though it is possible to collect field data for some case, high cost and labor are required and sometimes it is considered that the confidence of measured data is very low. In this case, the experimental data for unsteady flow can be used to calibrate and validate the numerical model as an alternative. Therefore, the discharge-supply system which could generate various type of unsteady flow hydrograph was developed in this study. Also, the accuracy of the unsteady flow hydrograph generated by developed dischargesupply system in the experiment was evaluated by comparing with target hydrograph. Accuracy errors and Root Mean Square Error (RMSE) were analyzed for the rectangular-type hydrograph with sudden changes of flow, triangular-type hydrograph with short peak time, and bell-type flood hydrograph. As a result, the generating error of the discharge-supply system for the rectangular-type hydrograph was about 59% which was maximum error among various types. Also, it was represented that RMSE for the triangular-type hydrographs with single and double peaks were approximately corresponding to 10%. However, RMSE for the bell-type flood hydrograph was lower than 2%.