• Title/Summary/Keyword: Peak Discharge

Search Result 628, Processing Time 0.022 seconds

Comparative Study on the Subsurface Drainage Discharge Performance by the Type of Non-Excavation Subsurface Drainage Culvert (비굴착 지하배수암거 형태별 지하배수 성능 비교분석)

  • Kim, Hyuntai;Ryu, Jeonyong;Jung, Kiyuol;Seo, Donguk
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.60 no.6
    • /
    • pp.73-81
    • /
    • 2018
  • In this study, subsurface discharge performance has been studied through theoretical seepage analysis on four types of culverts that can be installed under the condition of non-excavation, such as (a)perforated pipe(${\Phi}50mm$), (b)perforated pipe+horizontal mat (B50cm) (c)perforated pipe+horizontal mat+vertical gravel(B<10cm), (d)perforated pipe+vertical gravel(B<10cm), and existing typical type (e)perforated pipe with gravel (B40, h=40cm) which can be installed by excavation. The analysis results were as follows. i) Subsurface discharge performance per unit (m) was (a)type 56%, (b) 91%, (c) 96%, (d) 76%, respectively, lower than the value of (e)culvert. ii) However, considering that non-excavation culvert can be installed at a spacing of 5m with the installation cost of the existing excavation culvert at the interval of 10m, it was analyzed that unit subsurface discharge(q) of (a)20.2mm/day(110%), (b)32.8(178%), (c)34.6(188%) (d)27.5(149%) in the four types of non-excavation culvert installed at intervals of 5m under the condition of $ k=10^{-4}cm/s$ was much larger than the amount of (e)type 18.5(100%), existing excavation culvert installed at 10m interval. iii) Through the test construction, peak subsurface drainage discharge($q_p$) was 38.4mm/day, which is larger than the value of design criteria and confirmed that it satisfies the analysis results as well. iv) In particular, it was evaluated that (b)perforated pipe+horizontal mat(B50cm) are low cost, high efficiency subsurface drainage culvert type with sufficient drainage performance(178%).

The Characteristics of UV Generation and Aging Materials in According to Surface Discharge (연면방전에 의한 폴리머애자의 자외선 발생과 열화특성)

  • Shong, Kil-Mok;Bang, Sun-Bae;Kim, Chong-Min;Kim, Young-Seok;Jung, Jin-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.9
    • /
    • pp.1606-1611
    • /
    • 2008
  • Recently, The diagnosis techniques of electric facilities are developed on live line. This paper describes the discharge characteristics of polymer insulator(EPDM A type). Keeping the facilities in good working order, the goal of this paper will provide the information to enable user to easily judge conditions of facilities on the spot. The performance of polymer insulator is assessed from the KS C IEC 60270 and CEA LWIWG-01(96)(Tracking Wheel Test). As the results, UV generation patterns of polymer insulator grow like a jellyfish shape follow the ramping voltage. Discharging UVs are detected at about 31.25% of breakdown voltage. Just then, dimension of UV image is about $0.84cm^{2}$. The dimension of max. UV image is about $297.4cm^{2}$ at $160kV(V_{bd})$. The position of UV generation due to surface discharge of polymer insulator is the center of insulator in the early, then moved the ground side and the last, UV image moved through the junction part of source side. Surface of aged polymer insulator is cracked and faded due to arc. UV absorption spectrum of polymer insulator are appeared the C-H bond of scissoring vib. at $1014cm^{-1}$ and C=O bond of recombination structure. Also, recombined UV absorption peak such as C-H, N-H, and O-H is detected at the $3321cm^{-1}$. Through the paper, there are inspection data which are the relations between surface discharge of polymer insulator and UV detecting image.

Causual Analysis on Soil Loss of Safety Class Oryun Tunnel Area in Landslide Hazard Map (산사태 위험지도에서 안전등급지역인 오륜터널 일대의 토사유실 원인분석)

  • Kim, Tae Woo;Kang, In Joon;Choi, Hyun;Lee, Byung Gul
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.24 no.1
    • /
    • pp.17-24
    • /
    • 2016
  • At present, summer cloudburst and local torrential rainfalls have increased in this country, because of climatic change. Therefore, studies on prevention of soil loss have been actively proceeded, and Korea Forest Service has offered landslide hazard map. Landslide hazard map divides risks into 5 classes, by giving weight with 9 kinds of elements. In August 25 2014, soil loss occurred in the whole Oryun Tunnel, Geumjeong-gu, Busan, because of local torrential heavy rain. As a result of comparing with landslide hazard map, the area where soil loss occurred in reality is a safety zone on hazard map. Rainfall, soil map, geological map, forest type map, gradient, drainage network, watershed, basin shape, and efflux of the whole Oryun Tunnel where soil loss occurred were analyzed. As a result of an analysis, it is judged that soil, forest type, much efflux and peak discharge, degree of water network and basin shape of a place where landslide occurred are causes of soil loss. It is judged that efflux, peak discharge, and basin shape by the localized rainfall that is not considered in landslide hazard map of them are the biggest causes of soil loss. It is judged that efflux, peak discharge, degree of water network and basin shape by the rainfall are important through a study on a causual analysis on soil loss in the whole Oryun Tunnel where is one of occurrence area where a lot of propertywere lost by the record local torrential rainfalls. A localized torrential downpour should be prepared by considering these elements on judgement of a landslide hazard area.

An Analysis of Characteristic Parameters for the Design of Detention Pond in Urbanized Area (도시유역에서 저류지 설계를 위한 특성인자 분석)

  • Lee, Jae-Joon;Kim, Ho-Nyun;Kwak, Chang-Jae
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.6 no.4 s.23
    • /
    • pp.37-47
    • /
    • 2006
  • Urban development results in increased runoff volume and flowrates and shortening in time of concentration, which may cause frequent flooding downstream. Flow retardation structures to limit adverse downstream effects of urban storm runoff are used. There are various types of flow retardation measures include detention basins, retention basins, and infiltration basins. In basic planning phase, a number of planning models of detention ponds which decide storage volume by putting main variables were used to design detention ponds. The characteristics of hydrological parameters $\alpha,\;\gamma$ which are used in planning models of detention pond were analyzed. In this study, detention ponds data of Disaster Impact Assessment report at 22 sites were analyzed in order to investigate correlation between characteristic of urban drainage basin parameter and characteristics of detention pond parameter due to urbanization effects. The results showed that storage volume was influenced by peak discharge ratio $\alpha$ more than runoff coefficient ratio $\beta$ and peak discharge ratio $\alpha$ was influenced by runoff coefficient ratio $\beta$ less than regional parameter n. Storage ratio was mainly influenced by duration of design rainfall in the case of trapezoidal inflow hydrograph such as Donahue et al. method.

Shock-Fitting in Kinematic Wave Modeling (운동파 이론의 충격파 처리기법)

  • Park, Mun-Hyeong;Choe, Seong-Uk;Heo, Jun-Haeng;Jo, Won-Cheol
    • Journal of Korea Water Resources Association
    • /
    • v.32 no.2
    • /
    • pp.185-195
    • /
    • 1999
  • The finite difference method and the method of characteristics are frequently used for the numerical analysis of kinematic wave model. Truncation errors cause the peak discharge dissipated in the solution from the finite difference method. The peak discharge is conserved in the solution from the finite difference method. The peak discharge is conserved in the solution from the method of characteristics, however, the shock may deteriorates the numerical solution. In this paper, distinctive features of each scheme are investigated for the numerical analysis of kinematic wave model, and applicability of shock fitting algorithm such as Propagating Shock Fitting and Approximated Shock Fitting methods are studied. Propagating Shock Fitting method appears to treat shock properly, however, it failed to fit the shock appropriately when applied to a sudden inflow change in a long river. Approximate Shock Sitting method, which uses finer elements, is found to be more proper shock-fitting than the Propagating Shock Fitting method. Comparisons are made between two solution from the kinematic wave theory with shock fitting and full dynamic wave theory, and the results are discussed.

  • PDF

Evaluation of Flood Events Considering Correlation between Flood Event Attributes (홍수사상 요소의 상관성을 고려한 홍수사상의 평가)

  • Lee, Jeong Ho;Yoo, Ji Young;Kim, Tae-Woong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.3B
    • /
    • pp.257-267
    • /
    • 2010
  • A flood event can be characterized by three attributes such as peak discharge, total flood volume, and flood duration, which are correlated each other. However, the amount of peak discharge is only used to evaluate the flood events for the hydrological plan and design. The univariate analysis has a limitation in describing the complex probability behavior of flood events. Thus, the univariate analysis cannot derive satisfying results in flood frequency analysis. This study proposed bivariate flood frequency analysis methods for evaluating flood events considering correlations among attributes of flood events. Parametric distributions such as Gumbel mixed model and bivariate gamma distribution, and a non-parametric model using a bivariate kernel function were introduced in this study. A time series of annual flood events were extracted from observations of inflow to the Soyang River Dam and the Daechung Dam, respectively. The joint probability distributions and return periods were derived from the relationship between the amount of peak discharge and the total volume of flood runoff. Applicabilities of bivariate flood frequency analysis were examined by comparing the return period acquired from the proposed bivariate analyses and the conventional univariate analysis.

유한 요소법을 이용한 중소하천 유역에서의 이동호우에 대한 유출특성 분석

  • Cho, Hyeon-Kyeong;Lee, Yeung-Hwa;Choi, Yun-Yeong
    • Journal of Environmental Science International
    • /
    • v.7 no.4
    • /
    • pp.415-424
    • /
    • 1998
  • In the rainfalll-runoff relation, consideration of the spatial movement of storms is very unportant in designing a hydraulic structure or evaluating an environmental influence for land usage. Because of thins reason, this study has suggested the finite element model which consider the spatial movement of a storm and it was applied on a small river basin(Wi stream basin). In the application of the model, the basin was treated as a pivot point and the storms are simulated 10 movement in each directions. As a result, It shows that the storms moving from north to south have higher peak discharge and faster peak time than the storms moving in other directions. So these characteristics have to be considered In the designation of a hydraulic structure or evaluation of an environmental influence.

  • PDF

Estimation of Flood runoff using HEC-HMS at agricultural small watershed (HEC-HMS를 이용한 농업소유역에서의 홍수량 추정)

  • Kim, Sang-Min;Park, Seung-Woo
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.281-284
    • /
    • 2002
  • Geographic Information System (GIS) has advantage of analyzing spatial distributed data and handling spatial data for hydrologic analysis. Hydrologic Engineering Center's Hydrologic Modeling System(HEC-HMS) with HEC-GeoHMS was used to analyze flood runoff at agricultural small watershed. HEC-GeoHMS, which is an ArcView GIS extension designed to process geospatial data for HEC-HMS, is a useful tool for storing, managing, analyzing, and displaying spatially distributed data. Hydroligical component including peak discharge, time to peak, direct runoff, baseflow for Balhan study watershed, which is located in Whasung city, Kyunggi province, having an area of $29.79km^2$, were calculated using the HEC-HMS model with HEC-GeoHMS.

  • PDF

Zero Voltage and Zero Current Switching Full Bridge DC-DC Converter Using Novel Secondary Active Clamp (새로운 2차측 능동 클램프회로의 영전압 영전류 스위칭 Full Bridge DC-DC 컨버터)

  • Kim, Byung-Chul;Kim, Hyung-Gon;Kim, Kwang-Heon
    • Proceedings of the KIEE Conference
    • /
    • 1999.11a
    • /
    • pp.13-15
    • /
    • 1999
  • The zero voltage and zero current switching(ZVZCS) full bridge (FB) PWM converter using secondary active clamp is characterized by high efficiency, good ZVZCS characteristic, simple topology and low cost. But at the period for discharge of the secondary clamp capacitor, peak pulses and ringing pulse occur in rectified secondary side of the converter. In this paper, a novel secondary active clamp circuit for the ZVZCS FB PWM converter is proposed and a 50 kHz, 500 W prototype converter was experimented for verification of the converter characteristics. It was verified that high voltage peak pulses and ringing pulse on secondary rectified waveforms of the converter are decreased effectively.

  • PDF

Arc Phenomena and Induced Voltage due to Inductive Energy of Superconducting Coil (초전도 코일의 유도성 에너지에 의한 아크현상과 유기 과전압)

  • 최병주;류경우;성기철;김해종
    • Progress in Superconductivity and Cryogenics
    • /
    • v.2 no.1
    • /
    • pp.24-30
    • /
    • 2000
  • This paper present the characteristics of the internal induced voltage and arc phenomena in liquid helium at the energy transfer from a superconducting magnet to a load resistor. Especially generation mechanism of the oscillated wave from of the coil terminal voltage is analyzed by considering circuit constant of the superconducting magnet, load condition and arc resistance of the mechanical opening switch. The wavefront and peak portion of the voltage are strongly influenced by arc discharge triggered by the switch separation in liquid helium. Abrupt arc extinction leads to voltage oscillation with an enormous peak. It is suggested that the superconducting magnet should be designed to ensure the internal surge when arc is possibly formed by switch opening or coil short circuit between turns or layers. Finally, a suppression method of the oscillating surge is proposed based on the load condition.

  • PDF