• 제목/요약/키워드: Peak Discharge

검색결과 624건 처리시간 0.025초

냉음극형 대면적 펄스 전자빔 가속기의 빔인출 특성 (Characteristics of Electron Beam Extraction in Cold Cathode Type Large Cross-Sectional Pulsed Electron Beam Generator)

  • 우성훈;이광식;이동인;이홍식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1609-1611
    • /
    • 2001
  • A large cross-section pulsed electron beam generator of cold cathode type has been developed for industrial applications, for example, waste water cleaning, flue gas cleaning, and pasteurization etc. The operational principle is based on the emission of secondary electrons from cold cathode when ions in the plasma hit the cathode, which are accelerated toward exit window by the gradient of an electric potential. The conventional electron beam generators need an electron scanning beam because the small cross section thermal electron emitter is used. The electron beam of large cross-section pulsed electron beam generator do not need to be scanned over target material because the beam cross section is large by 300$cm^2$. We have fabricated the large cross-sectional pulsed electron beam generator with the peak energy of 200keV and beam diameter of 200mm and obtained the large area electron beam in the air. The electron beam current has been investigated as a function of accelerating voltage, glow discharge current, helium pressure, distance from the exit window and radial distribution in front of the exit window.

  • PDF

송변전급(up to class 5) Impulse current test system의 설계 및 특성 (Design & characteristics of impulse current test system for station class(up to class 5))

  • 김석수;최익순;강영식;박병락;박태곤
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.2
    • /
    • pp.1146-1149
    • /
    • 2004
  • A new developed impulse current test system(100kV, 250kJ)is presented, which can carry out all impulse current and performance tests on surge arrester sections with rated voltage up to 12kV according to IEC 60099-4(2001). The maximum achievable peak value is 200kA for the impulse current $4/10{\mu}s$ and 60kA for the $30/80{\mu}s$ and $8/20{\mu}s$. The long duration current impulse is realized from class 1 to class 5. The digital transient recorder(4 channels 60MS/S 10bit) is used for measuring AC voltage, impulse current, reference voltage and leakage current. The complex control, measuring, evaluation and data storage system is controlled by one industrial PC system.

  • PDF

동해의 가을철 저염수 분포 및 유동 (Distribution and Circulation of Autumn Low-salinity Water in the East Sea)

  • 이동규;이재철
    • 한국수산과학회지
    • /
    • 제50권2호
    • /
    • pp.207-218
    • /
    • 2017
  • Seawater with salinity of 32.5 psu or less is observed in the southern Japan/East Sea (JES) every autumn. It is confined to a surface layer 30-45 m in depth that expands to cover the entire JES in October. Two sources of "autumn low-salinity water" have been identified from historical hydrographic data in the western JES: East China Sea (ECS) water mixed with fresh water discharge from the Yangtze River (Changjiang) and seawater diluted with melted sea ice in the northern JES. Low-salinity water inflow from the ECS begins in June and reaches its peak in September. Low-salinity water from the northern JES expands southward along the coast, and its horizontal distribution varies among years. A rare observational study of the entire JES in October 1969 indicated that water with salinity less than 33.0 psu covered the southwestern JES; the lowest salinity water was found near the Ulleung Basin. In October 1995, the vertical distribution of salinity observed in a meridional section revealed that water with salinity of 33.6 psu or less was present in the area north of the subpolar front.

홍수시(洪水時) 소양강(昭陽江)댐 및 화천(華川)댐의 최적운영(最適運營)을 위한 시뮬레이션 (Simulation for the Optimal Operation of Soyanggang Dam and Hwachon Dam in the Flood Periods)

  • 이길성;전경수
    • 대한토목학회논문집
    • /
    • 제6권1호
    • /
    • pp.13-24
    • /
    • 1986
  • 본(本) 논문(論文)에서는 북한강(北漢江) 수계(水系)의 소양강(昭陽江)댐 및 화천(華川)댐의 실시간(實時間) 홍수조절(洪水調節) 모형(模型)을 개발(開發)하였다. 그 방법으로는 feedforward-feedback control에 의한 Simulation기법은 사용하였다. 즉, 예측 유입량을 이용한 단일댐 운영방안에 의하여 구간 각 댐의 방류량으로부터 두 댐의 합류점(合流點)에서의 유량을 구한 후 Feedback control에 의하여 합류점(合流點)의 첨두 유량을 경감하도록 상류댐 방류량을 재조정하도록 하였다. 또한 개발(開發)된 모형(模型)에 관한 민감도(敏感度) 분석(分析)을 행하였다.

  • PDF

Opto-Hertzian 효과를 이용한 고주파 여기식 슬랩 CO2 레이저의 출력 안정화 (Power stabilization of a slab CO2 laser by using the Opto-Hertzian effect)

  • 최종운;우삼용;김규식;이영우
    • 한국광학회지
    • /
    • 제15권4호
    • /
    • pp.337-342
    • /
    • 2004
  • 본 연구에서는 opto-Hertzian 효과를 이용하여 고주파 여기식 슬랩형 $CO_2$ 레이저의 출력을 안정화하였다. 슬랩레이저 공진기속의 복사선 세기가 변화할 때 opto-Hertzian 효과에 의해서 공진기의 방전 임피던스도 함께 변화한다. 이에 따라 공진기로 입사 또는 반사되는 고주파 에너지 값도 변화한다. 이 같은 변화를 결합 루프를 통해 검출하여 고주파 성분을 제거한 후 록인 안정기에서 발생시킨 오차신호를 기준신호로 사용하여 슬랩 레이저의 출력을 안정화하였다. 본 방법으로 안정화된 레이저의 출력 변동률이 0.2%로 개선됨을 확인하였다.

리튬 2차 전지용 Li[Co0.1Ni0.15Li0.2Mn0.55]O2 양극물질의 안정성 고찰 (Stability of Li[Co0.1Ni0.15Li0.2Mn0.55]O2 Cathode Material for Lithium Secondary Battery)

  • 박용준
    • 한국전기전자재료학회논문지
    • /
    • 제20권5호
    • /
    • pp.443-449
    • /
    • 2007
  • The structural and thermal stability of $Li[Co_{0.1}Ni_{0.15}Li_{0.2}Mn_{0.55}]O_2$ electrode during cycling process was studied. The sample was prepared by simple combustion method. Although there were irreversible changes on the initial cycle, O3 stacking for $Li[Co_{0.1}Ni_{0.15}Li_{0.2}Mn_{0.55}]O_2$ structure was retained during the first and subsequent cycling process. Impedance of the test cell was decreased after the first charge-discharge process, which would be of benefit to intercalation and deintercalation of lithium ion on subsequent cycling. As expected, cycling test for 75 times increased impedance of the cell a little, instead, thermal stability of $Li[Co_{0.1}Ni_{0.15}Li_{0.2}Mn_{0.55}]O_2$ was improved. Moreover, based on DSC analysis, the initial exothermic peak was shifted to high temperature range and the amount of heat was also decreased after cycling test, which displayed that thermal stability was not deteriorated during cycling.

저토크리플 및 역률개선을 위한 수정된 단상 SRM 구동시스템 (Modified Single-Phase SRM Drive for Low Torque Ripple and Power Factor Improvement)

  • 안영주
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제31권8호
    • /
    • pp.975-982
    • /
    • 2007
  • The single-phase switched reluctance motor(SRM) drive requires DC source which is generally supplied through a rectifier connected with a commercial source. The rectifier is consist of a diode full bridge and a filter circuit. Usually the filter circuit uses capacitor with large value capacitance to reduce ripple component of DC power. Although the peak torque ripple of SRM is small, the short charge and discharge current of the filter capacitor draws the low power factor and system efficiency. A modified single phase SRM drive system is presented in this paper, which includes drive circuit realizing reduction of torque ripple and improvement of power factor. In the proposed drive circuit, one switching part and diode which can separate the output of AC/DC rectifier from the filter capacitor is added. Also, a upper switch of drive circuit is exchanged a diode in order to reduce power switching device. Therefore the number of power switch device is not changed, two diodes are only added in the SRM drive. To verify the proposed system, some simulation and experimental results are presented.

Surface modification of $TiO_2$ by atmospheric pressure plasma

  • 조상진;정충경;부진효
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2010년도 제39회 하계학술대회 초록집
    • /
    • pp.96-96
    • /
    • 2010
  • To improve surface wettability, each sample was treated by atmospheric pressure plasma (APP) using dielectric barrier discharge (DBD) system. Argon and oxygen gases were used for treatment gas to modify the $TiO_2$ surface by APP with RF power range from 50 to 200 W. Water contact angle was decreased from $20^{\circ}$ to $10^{\circ}$ with argon only. However, water contact angle was decreased from $20^{\circ}$ to < $1^{\circ}$ with mixture of argon and oxygen. Water contact angle with $O_2$ plasma was lower than water contact angle with Ar plasma at the same RF power. It seems to be increasing the polar force of $TiO_2$ surface. Also, analysis result of X-ray photoelectron spectra (XPS) shows the increase of intensity of O1s shoulder peak, resulting in increasing of surface wettability by APP. Moreover, each water contact angle increased according to increase past time. However, contact angle increase with plasma treatment was lower than without plasma treatment. Additionally, the efficiency of $TiO_2$ photocatalyst was improved by plasma surface-treatment through the degradation experiment of phenol

  • PDF

수퍼캐패시터를 이용한 권상부하 시스템의 전력 제어 (Power Control of a Hoist System Using Supercapacitor)

  • 김상민;유현재;설승기
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제54권11호
    • /
    • pp.561-568
    • /
    • 2005
  • This paper proposes a method that distributes the load power and stores the regenerated energy for a hoist-load system using the supercapacitor, an energy storage device. The crane, which is a representative hoist-load system, operates in two modes. The first is the hoist-up mode in which the load container is lifted up: the maximum power is required at the end of acceleration. The second is the hoist-down mode in which the load container is lifted down; the regenerated energy is wasted by the resistor In this paper, the supercapacitor stores the regenerated energy in the hoist-down operation and supplies the peak power demand in the hoist-up operation. The same structure as the commercially available three-phase inverter is proposed as a bidirectional do-dc converter to charge and discharge the supercapacitor. A power control algorithm is proposed to optimize the load sharing between the generator and the supercapacitor. Using the proposed method, it is effected that the generator size can be cut down to one third of the original one; it leads to the reduction of the fuel consumption, noise and air pollution. Simulation and experimental results verify the effectiveness of the Proposed method.

아아크방전 유도형 이온플레이팅에 의한 Cr-N 피막의 특성 (Properties of Cr-N Films Prepared by the Arc-induced Ion Plating)

  • 정재인;문종호;홍재화;강정수;이영백
    • 한국표면공학회지
    • /
    • 제24권1호
    • /
    • pp.24-24
    • /
    • 1991
  • Cr-N films were deposited on low-carbon steel sheets by the reactive arc-induced ion plating (AIIP). The influence of the deposition conditions (nitrogen pressure and substrate bias voltage) on the crystal orientation, morphology and microhardness of the Cr-N films has been investigated using x-ray diffractometer and scanning electron microscope. The impurities and contaminations on the surface and at the interface, and the layer-by-layer compositions of the film have been analyzed using scanning Auger multiprobe (SAM) and glow discharge spectroscope (GDS). The mixed state of Cr and Cr2N turned out to have a fine fibrous structure. The Cr2N films were deposited at a wide range of nitrogen flow rates. The orientations of Cr2N films were mainly (110) and (111), and the intensity of the (111) peak increased as the substrate bias voltage increased. The micorstructure of the Cr2N film was dense and no columnar structure was observed. The films in the mixed state of Cr2N and CrN were also dense without columnar structure. The maximum microhardness of the Cr-N films was 2400 kg/$\textrm{mm}^2$ at 10gf load.