• 제목/요약/키워드: Peak Discharge

검색결과 624건 처리시간 0.039초

농업수리구조물의 적정설계홍수량 유도를 위한 유출수문곡선모형의 개발(I) (Development of Runoff Hydrograph Model for the Derivation of Optimal Design Flood of Agricultural Hydraulic Structures(1))

  • 이순혁;박명근;맹승진
    • 한국농공학회지
    • /
    • 제37권3_4호
    • /
    • pp.34-47
    • /
    • 1995
  • It is experienced fact as a regular annual event that the structure to he designed on unreasonable flood for the agricultural structures including reservoirs have been brought not only loss of lives, but also enormous property damage. For the solution of this problem at issue, this study was conducted to develop an optimal runoff hydrograph model by comparison of the peak flows and time to peak between observed and simulated flows derived by linear time-invariant and linear time-variant models under the condition of having a short duration of heavy rainfall with uniform rainfall intensity at nine small watersheds which are within the range of 55.9 to 140.7 square kilometers in area in Han, Geum, Nagdong and Yeongsan Rivers. The results obtained through this study can be summarized as follows. 1. Storage constants and Gamma function arguments were calculated within the range of 1.2 to 6.42 and of 1.28 to 8.05 respectively by the moment method as the parameters for the analysis of runoff hydrograph based on linear time-invariant model. 2. Parameters for both linear time-invariant and linear time-variant models were calibrated with nine gaged watershed data, using a trial and error method. The resulting parameters including Gamma function argument, N and storage constant, K for linear time-invariant model were related statistically to watershed characteristic variables such as area, slope, length of main stream and the centroid length of the basin. 3. Average relative errors of the simulated peak discharge of calibrated runoff hydrographs by using linear time-variant and linear time-invariant models were shown to be 0.75 and 5.42 percent respectively to the peak of observed runoff hydrographs. Correlation coefficients for the statistical analysis in the same condition were shown to be 0.999 and 0.978 with a high significance respectively. Therefore, it can be concluded that the accuracy of a linear time-variant model is approaching more closely to the observed runoff hydrograph than that of a linear time-invariant model in the applied watersheds. 4. Average relative errors of the time to peak of calibrated runoff hydrographs by using linear time-variant and linear time-invariant models were shown to be 16.44 and 19.89 percent respectively to the time to peak of observed runoff hydrographs. Correlation coefficients in the same condition were also shown to be 0.999 and 0.886 with a high significance respectively. 5. It can be seen that the shape of simulated hydrograph based on a linear time- variant model is getting closer to the observed runoff hydrograph than that of a linear time-invariant model in the applied watersheds. 6. Two different models were verified with different rainfall-runoff events from data for the calibration by relative error and correlation analysis. Consequently, it can be generally concluded that verification results for the peak discharge and time to peak of simulated runoff hydrographs were in good agreement with those of calibrated runoff hydrographs.

  • PDF

임계노즐 유동에 미치는 노즐 곡률의 영향 (Effect of the Nozzle Curvature on Critical Flows)

  • 김재형;김희동;박경암
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2002년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.331-336
    • /
    • 2002
  • Recently the critical nozzles with small diameter are being extensively used to measure mass flow in a variety of industrial fields and these have different configurations depending on operation condition and working gas. The curvature radius of the critical nozzle throat is one of the most important configuration factors promising a high reliability of the critical nozzle. In the present study, computations using the axisymmetric, compressible, Navier-Stokes equations are carried out to investigate the effect of the nozzle curvature on critical flows. The diameter of the critical nozzle employed is D=0.3mm and the radius of curvature of the critical nozzle throat is varied in the range from 1D to 3D. It is found that the discharge coefficient is very sensitive to the curvature radius(R) of critical nozzle, leading to the peak discharge coefficient at R = 2.0D and 2.5D, and that the critical pressure ratio increases with the curvature radius.

  • PDF

4.16kV 전동기 고정자 권선의 절연열화 특성 (Characteristics of Insulation Aging in 4.16kV Motor Stator Windings)

  • 김희동;공태식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1381_1382
    • /
    • 2009
  • Nondestructive tests were performed on two 4.16kV motors. Epoxy-mica coupler(80pF) was connected to 4.16 kV motor stator windings. The voltage applied to the stator windings was 2.4 kV, 3.0kV, 3.5kV and 4.16kV, respectively. Digital partial discharge detector(PDD) and turbine generator analyzer(TGA) were used to measure partial discharge(PD) activity. TGA summarizes each plot with two quantities such as the normalized quantity number(NQN) and the peak PD magnitude(Qm). The PD levels in pC were measured with PDD. PD patterns of stator windings were indicated the internal discharge. PD patterns are consistent with the result of measurement using PDD and TGA.

  • PDF

The Method to Improve the Luminance Efficiency by Auxiliary Capacitor in AC PDP

  • Lee, Ji-Hoon;Lee, Don-Kyu;Choi, Joon-Young;Ok, Jung-Woo;Kim, Dong-Hyun;Lee, Ho-Jun;Park, Chung-Hoo;Lee, Hae-June
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2006년도 6th International Meeting on Information Display
    • /
    • pp.913-916
    • /
    • 2006
  • The improvement of luminous efficacy is one of the major issues in PDP industry. In this work, we propose the new driving method for high efficiency AC-PDP and analyze its discharge characteristics. The suggested method can control the effective capacitance of panel by external auxiliary capacitor. External capacitor induces reduction of gap voltage proportional to the panel current, this in turn modifies the transient behaviour of discharge. The peak current level is reduced and the discharge duration is increased. As a result of these modifications, the luminous efficacy is enhanced by about 200% compared with the conventional driving method

  • PDF

고압전동기 결함신호의 특징추출에 관한 연구 (Feature Extraction for Fault Signals of High Voltage Motor Stator Windings)

  • 박재준;김희동
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.2
    • /
    • pp.1154-1157
    • /
    • 2004
  • During normal machine operation, partial discharge(PD) measurements were performed with turbine generator analyzer(TGA) in imitation stator winding of high voltage motors. The motor was energized to 4.47kV, 6.67, respectively. Applied voltage to Imitation winding was used two voltage level, 4.47[KV]and 6.67[KV]. Motors having imitation stator winding were installed with 80pF capacitive couplers at the terminal box Case of PD Pattern regarding applied voltage phase angel, the PD patterns were displayed two dimensional and three dimensional. TGA summarizes each plot with two quantities such as the normalized quantity number(NQN) and the peak PD magnitude(Qm). As the result, we could discrimidate using TGA the difference of internal and surface discharge for imitation stator winding. We have used the other technique, in order to feature extraction of faulty signals on stator winding, Daubechies Discrete wavelet transform and Harmonics analysis(FFT) about faulty signals.

  • PDF

방사전자파의 주파수분석에 의한 배전반 진단기술 (Diagnostic Technique of a Switchboard by Frequency Analysis of Radiated Electromagnetic Wave)

  • 박대원;김선재;정광석;길경석;조은제
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.41-45
    • /
    • 2010
  • In this paper, we analyzed the frequency spectrum of radiated electromagnetic waves generated by series arc- and corona- discharges as a basic study to develop an online diagnostic technique for power facilities installed inside switchboards. To simulate corona and series arc discharges, an arc generator specified in UL1699 and a corona generator were fabricated. The experiment was carried out in an electromagnetic shielding room, and the measurement system consists of an Ultra Log Antenna and an EMI Test Receiver. The frequency spectrum exists in ranges from 30 to 500 [MHz] for series arc discharge and 30 [MHz] to 2 [GHz] depending on defects for corona discharge. The peak frequency of series arc discharge and corona were 40 [MHz], 80 [MHz] and 35 [MHz]~160 [MHz], respectively.

  • PDF

도깨비봉형 오존발생장치이 펄스커로나 방전에 의한 오존 발생 특성 (High Efficiency Ozone Generation Using a Pyramid-Project-Embossed Rod-to-Cylinder Electrode and a Pulse Corona Discharge)

  • 문재덕;이근택
    • 대한전기학회논문지
    • /
    • 제38권8호
    • /
    • pp.650-657
    • /
    • 1989
  • The conversion efficiency of an ozone generator can be significantly improved by modifying the discharge electrode of a helical strip line rod-to-cylinder type ozone generator to a pyramid-project-embossed rod, and by using a pulse corona discharge. Parametric studies have been carried out to obtain optimum values of peak pulse voltage, pulse forming capacitance, feeder cable and ozone generator capacitance, interelectrode spacing and corona tip density of ozone generator, and feed air flow rate and temperature. The generated ozone concentration was very dependent upon the value of pulse forming capacitance, feeder cable and ozone generator capacitance, and corona tip density. Maximum conversion efficiency was obtained with a pulse forming capacitance of about 500pF, 75pF matched feeder cable and ozone generator, and a corona tip density of 16mm. When operated at optimum values, ozone yield of 79, 99, 80 g/KWh for the different interelectrode type ozone generators tested were obtained, which are approximately 30% higher than that of an industrial ozone generator.

  • PDF

저압용 전기전자부품의 신뢰성 평가를 위한 부분방전 측정시스템에 관한 연구 (A Study on the PD Measurement System for Estimating Reliabilities of Low-voltage Electrical and Electronic Components)

  • 서황동;송재용;문승보;길경석;강동식;황돈하
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 추계학술대회 논문집 Vol.18
    • /
    • pp.321-322
    • /
    • 2005
  • In this paper, we dealt with a partial discharge(PD) measurement system that has been accepted as an effective and non-destructive technique for estimating reliabilities of low-voltage electrical and electronic components. Calibration tests on laboratory set-up have shown that the PD measurement system has a stable sensitivity of 37.6 mv/pC. In an application test on photo coupler, we could detect 0.1 pC level of partial discharge at the applied voltage of AC 520 $V_{peak}$.

  • PDF

Cavity-backed Two-arm Spiral Antenna with a Ring-shaped Absorber for Partial Discharge Diagnosis

  • Kim, Han-Byul;Hwang, Keum-Cheol;Kim, Hyeong-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권4호
    • /
    • pp.856-862
    • /
    • 2013
  • A cavity-backed two-arm spiral antenna for partial discharge diagnosis is presented. The proposed antenna consists of a two-arm Archimedean spiral, a tapered microstrip balun as spiral antenna feed, and a ring-shaped absorber-loaded cavity. The Archimedean spiral antenna is designed for the operating frequency band of 0.3 GHz to 1.5 GHz and fed by the tapered microstrip balun. The cavity is utilized to transform the bidirectional beam into a unidirectional beam, thereby enhancing gain. The ring-shaped absorber is stacked in the cavity to reduce the reflected waves from the cavity wall. The proposed antenna is designed and simulated using CST Microwave Studio. A prototype of the proposed antenna is likewise fabricated and tested. The measured radiation patterns are directional to the positive z-axis, and the measured peak gain is 8.13 dBi at a frequency of 1.1 GHz.