• 제목/요약/키워드: Peak Detector

검색결과 323건 처리시간 0.025초

A measurement of wave length response on light emitting diode by a simplified wavemeter with a semiconductor color sensor

  • Muraoka, Tetsuya
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1991년도 한국자동제어학술회의논문집(국제학술편); KOEX, Seoul; 22-24 Oct. 1991
    • /
    • pp.1956-1960
    • /
    • 1991
  • This paper describes the measured results upon monochromatic light, compound light, and light emanated from light emitting diodes by a simplified wavemeter with a semiconductor color sensor. Since a single unit element of a semiconductor color sensor with two PN junction photodiodes has been developed, the author has fabricated the simplified wave detector by using the element. The simplified wive detector has been measured results upon monochromatic light, compound light, and light emanated from light emitting diodes. Since luminescent color of each diode locates in luminosity region, comparison of measured values of PD-150 and PD-151 resulted no remarkable difference in averaged wave length. As for monochromatic light, PD-151 showed very cross value to the color filter peak value rather than PD-150. As for compound light, PD-150 has shown such influence of long wave length light which reaches to near infrared ray with respect to PD-151.

  • PDF

기체크로마토그래피/질량분석기에 의한 저질 및 토양시료 중 벤조페논의 분석법 연구 (Analysis of Benzophenone in Sediment and Soil by Gas Chromatography/Mass Spectrometry)

  • 권오승;김은영;류재천
    • Environmental Analysis Health and Toxicology
    • /
    • 제16권3호
    • /
    • pp.121-126
    • /
    • 2001
  • Analytical method of benzophenone (BP) in sediment and soil was developed by gas chromatography/mass selective detector/selected ion monitoring (GC/MSD/SIM). The ultrasonic extraction of US EPA (method 3550B) method and liquid-liquid extraction for sediment and soil samples were used for the analysis of BP from sediment and soil. BP was extracted with n-hexane. Organic layer was washed with 5% sodium chloride solution. 1∼2 l of the concentrated solution of organic layer was applied to GC/MSD. The retention time of BP peak was 11.10 min. Recovery (%) of BP by ultrasonication from sediment and soil samples was 96.0∼100.6% and 40.0∼83.0%, respectively. Recovery of BP by liquid-liquid extraction was 51∼59% in soil samples. The detection limit of BP in sediment and soil samples were determined to 0.1 ng/g.

  • PDF

열탈착/GC/FID를 이용한 B, T, X 분석의 정확도 및 정밀도 평가 (A Study on Evaluation of Accuracy and Precision on B, T, X Analysis Using Thermal Desorption/Gas Chromatograph/Flams Ionization Detector)

  • 박정근;유기호
    • 한국대기환경학회지
    • /
    • 제16권3호
    • /
    • pp.265-275
    • /
    • 2000
  • By using thermal desorption/gas chromatograph/flame ionization detector(TD/GC/FID), this study was carried out to evalute an accuracy and a precision on Benzene(B), Toluene(T), o-Xylene(X) analysis in an industrial hygiene laboratory. Limits of detection of TD/GC/FID on B, T, X were showed 13.75ng/sample or less. For the accuracy of the method by concentration levels, overall bias was showed 7.7% as an absolute value, and the pooled coefficient of variation showed 3.51%. For the precision on repeatability of peak area and retention time between within-run and between-run of analytical system, it is showed the results of within-run gave better than those of between-run. Also the accuracy by sorbents(Tenax TA and Chromosorb 106)was evaluated, and the precision on reproducibility between MDHS72 and this study was compared. It is showed it is possible for TD/GC/FID to evaluate accurately B, T, X concentration levels of less than 1ppm at indoor or outdoor of workplaces in Korea.

  • PDF

즉발감마선 계측시스템의 반사체를 이용한 열중성자 효율증대 연구 (Study on Thermal Neutron Efficiency for Neutron Induced Prompt Gamma-ray Spectrometer Using Various Reflectors)

  • 박용준;송병철;지광용
    • 분석과학
    • /
    • 제16권5호
    • /
    • pp.426-429
    • /
    • 2003
  • Neutron induced prompt gamma-ray spectroscopy (NIPS) system equipped with a $^{252}Cf$ neutron source and a n-type coaxial HPGe detector was installed for the quantitative analysis of aqueous samples in KAERI, Korea. Since the thermal neutron flux for the $^{252}Cf$ neutron source is relatively low compared to that for the reactor, the use of a thermal neutron reflector in the NIPS system may lead to improved results. The enhancement by using various reflectors was carried out by comparing the Cl peak with or without a cadmium plate between sample and the $^{252}Cf$ source. The use of pyrolitic graphite as a reflector provided a good result.

Prussian blue가 전착된 indium tin oxide 전극을 이용한 전기화학적 검출기 (An Electrochemical Detector Using Prussian Blue Electrodeposited Indium Tin Oxide Electrode)

  • 이인제;김주호;강치중;김용상
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권10호
    • /
    • pp.449-452
    • /
    • 2005
  • We fabricated an electrochemical detector (ECD) to catalyze redox reaction efficiently by electrodepositing Prussian blue (PB) on the indium tin oxide (ITO) electrode. Capillary electrophoresis (CE) and amperometric method were used. We investigated the PB surface properties by topography from atomic force microscopy (AFM). Also PB film thickness calibration with respect to deposition time and voltage was used to get better PB surFace. The PB thin film of dense and smooth surface could catalyze redox reaction efficiently. Comparing with CE-ECD microchip using bare-lTO electrode, proposed CE-ECD microchip using PB deposited electrode has shown better sensitivity by determining the detected peak current from the electropherograms while the concentration of tested analyzes was maintained the same. It is verified that detection limit can be lowered for 0.01 mM of dopamine and catechol respectively.

화재감지 센서 작동시간 및 열방출률에 대한 실험연구 (A Experimental Study on the Heat Release Rate to activate Fire Detection Sensor)

  • 홍성호
    • 전기학회논문지
    • /
    • 제61권9호
    • /
    • pp.1358-1361
    • /
    • 2012
  • This paper presents a study on the analysis for activation time and threshold value of heat detection sensor using HRR(Heat Release Rate). And it is represented to quantity of heat to activate heat detection sensor. The experiment is conducted to measure activation time and HRR of fire detection sensor burning alcohol and n-heptane. In order to burn the alcohol and n-heptane using $43.5cm(L){\times}43.5cm(W){\times}5cm(D)$ and $33cm(L){\times}33cm(L){\times}5cm(D)$ steel pan and the quantity of alcohol and n-heptane are 2.5 L and 650 g, respectively. The results show that peak HRR are in case of alcohol 66.13 kW and in case of n-heptane 151.64 kW, respectively. Total heat releases of heat detection sensor are in case of alcohol approximately 20.7 MJ and in case of n-heptane approximately 18 MJ, respectively.

Biomass 자원의 활용 (I) - 율추의 유효이용을 위한 화학적 조성분의 HPLC 분석 - (Utilization of Biomass Resources(I) - HPLC Analysis of Chemical Components for Utilization of Chestnut Inner Bark -)

  • 김윤근;조종수
    • Journal of the Korean Wood Science and Technology
    • /
    • 제32권2호
    • /
    • pp.58-64
    • /
    • 2004
  • 임산바이오매스 자원 이용의 일환으로 율추(栗皺) 열수추출물의 디에틸에테르 가용부의 HPLC 분석결과, 표준물질과의 retention time이 일치한 것을 RI detector로 얻어진 각 피크의 스펙트럼을 표준물질과 비교하고, 순도를 확인하는 방법으로 피크의 동정을 실시하였다. 피크의 동정 결과, phenolic acids와 aldehyde류로는 gallic acid, 3,5-dihydroxybenzoic acid, 2,4,6-trihydroxybenzoic acid, 그리고 protocatechualdehyde이었으며, flavonoids는 catechin과 epicatechin으로 모두 6종이 확인되었다.

Capillary electrophoresis를 이용한 율무의 원산지 판별 (Identification of Cultivate Sites for Job's-tears (Coix lachrymajobi var. mayuen) using Capillary Electrophoresis)

  • 류미라;김은영;김상숙
    • 한국식품과학회지
    • /
    • 제34권5호
    • /
    • pp.787-791
    • /
    • 2002
  • 수입자유화이후 유입량이 급증한 농산물중 하나인 율무의 원산지 판별을 위하여 CE의 적용가능성을 검토하였다. 분석을 위한 지표물질의 추출을 위해 30% ethanol을 사용하였으며, $50\;{\mu}m\;I.D.{\times}27\;cm$(20 cm inlet to detector)의 capillary를 이용하여 $45^{\circ}C$, 15 kV로 200 nm에서 detect 하였다. 분석 buffer는 0.1 M phosphate buffer(pH 2.5)에 30% methanol과 26 mM HSA를 첨가하였으며, pressure injection 20초, detector rise time 0.1초로 하였다. 분석시 초기에 증류수와 0.1 M phosphate buffer(pH 2.5)로 각 5분씩 capillary를 rinse하고 분석 buffer로 10분간 equilibration 시킨 후 30분간 분석하고 다시 1 M phosphoric acid로 14분간 rinse하여 다음 시료 분석시의 오차를 줄였다. 이 조건으로 2000년 및 2001년의 국산 및 수입산 율무 총 240점을 분석한 결과 서로를 구분하는 peak JT5의 도출이 가능하였으며 이 peak JT5에 의한 국산 및 수입산 율무의 판별율은 2000년 시료에서는 국산이 총 47점 중 39점(판별율 약 83%), 수입산은 총 48점 중 39점(판별율 약 81%), 2001년 시료는 국산 총 74점 중 60점(판별율 약 81%), 수입산은 총 71점 중 59점(판별율 약 83%)이었으며 전체적으로 약 82%의 판별율을 나타내었다.

$^{23}Na$(p, $\gamma$)$^{24}Mg$$^{27}Al$(p, $\gamma$)$^{28}Si$반응을 이용한 HPGe 검출기의 응답함수 (Response Function of HPGe Detector using $^{23}Na$(p, $\gamma$)$^{24}Mg$ and $^{27}Al$(p, $\gamma$)$^{28}Si$ Reaction)

  • 박상태
    • Journal of Radiation Protection and Research
    • /
    • 제35권2호
    • /
    • pp.85-90
    • /
    • 2010
  • 본 연구에서는, 에너지에 따른 peak의 상대효율을 구하였으며, 검출기의 응답함수를 작성하였다. 이를 위해 고효율, 고분해능을 가진 HPGe 검출기(지름 78.7 mm, 길이 86.5 mm)를 이용하였으며 콤프턴 억제용으로 NaI 검출기를 사용하였다. 감마선 스펙트럼은 $^{23}Na$(p, $\gamma$)$^{24}Mg$$^{27}Al$(p, $\gamma$)$^{28}Si$ 반응을 이용하여 얻었으며, 이 때 입사 입자의 에너지는 각각 $E_p$ = 1424 keV 및 $E_p$ = 992 keV 이었다. 한편 스펙트럼 측정은 입사 빔 방향에 대해 $55^{\circ}$에서 하였으며, 사용한 가속기는 일본 동경공업대학의 3 MeV Pelletron 가속기를 이용하였다. 검출기의 응답함수는 1.2 MeV에서 9.4 MeV까지 0.75 MeV 간격으로 작성하였다.

적외선 LED를 이용한 무인 주행 저속 전기 자동차용 라인트레이서에 관한 연구 (The study of the linetracer-developement for the Automatic Guided Vehicle using Infrared LED)

  • 최성욱;김석원;최재호;김호성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1967-1969
    • /
    • 2003
  • 본 논문에서는 무인 주행 저속 전기 자동차 시스템 개발을 위한 적외선 LED 라인트레이서를 제작하였다. 햇빛에 의한 영향을 제거하기 위해 적외선 LED를 펄스(pulse)로 구동시켰으며 흰색선에서 반사된 적외선 신호를 photodiode를 이용하여 감지하였다. 감지된 신호는 증폭단과 Peak Detector를 거쳐 최종적으로 AVR MCU로 입력이 된 후 여러 상황에 따른 차량의 방향을 결정할 수 있도록 알고리즘를 통해 처리하였다. 실험을 통하여 본 논문에서 제작한 라이트레이서 모듈이 원하는 방향으로 동작함을 확인하였다.

  • PDF