• Title/Summary/Keyword: Pattern unit

Search Result 1,081, Processing Time 0.022 seconds

Slope Stability and Development of Debris Flow Deposit in the Ulleung Basin, East Sea (동해 울릉분지의 사면안정성 및 쇄설류 퇴적체의 발달)

  • Lee, Sun-Jong;Lee, Jeong-Min;Yoo, Dong-Geun;Lee, Go-Eun;Park, Soo-Chul
    • Economic and Environmental Geology
    • /
    • v.50 no.2
    • /
    • pp.129-143
    • /
    • 2017
  • The shallow sediments in the southwestern Ulleung Basin consist of mass flow deposits such as slide/slump and debris flow deposits (DFD), caused by slope failure. These sediments are proven to be important in studying geological disaster and stability of the seafloor. In this paper, we analysised the flow accumulation and slope failure susceptibility of the Ulleung Basin on the basis of multi-beam data, collected in this area. We also studied the distribution pattern and the seismic characteristics of the DFD in the uppermost layer of the Ulleung Basin on the basis of seismic data. The slope susceptibility was calculated as the frequency ratio of each factors including slope, aspect, curvature and stream power index (SPI), which causes the slope failure. These results indicate that the slope failure is frequently to occur in the southern and western continental slope of the Ulleung Basin. The sediment flow (mass flow) caused by the slope failure converges to the north and northwest of the Ulleung Basin. According to the seismic characteristics, the uppermost layer in study area can be divided into four sedimentary unit. These sedimentary units develop from the south and southwest to the north and northwest in association with slope susceptibility and flow accumulation.

Heat Consumption Pattern Analysis by the Component Ratio of District Heating Users (지역난방 사용자 구성비에 따른 열소비 패턴 분석)

  • Lee, Hoon;Lee, Min-Kyun;Kim, Lae Hyun
    • Journal of Energy Engineering
    • /
    • v.22 no.2
    • /
    • pp.211-225
    • /
    • 2013
  • To run an optimal operation of Integrated energy supply facilities, we need to analyze heat consumption patterns of District heating users and derive optimum and maximum load ratio of heat production facilities unit. This study selects three District heat production facilities. It also classifies District heating users into residential apartment buildings and eight non-residential buildings and analyzes heat consumption results for an year. Finally it carries out the analysis of how the ratio change of each type affects maximum load ratio, facility utilization ratio, heat supply range. According to this study, three different District heat facilities of residential apartment building show similar daily and annual heat consumption patterns. Annual average load ratio, maximum load ratio and annual heat demand increase as outdoor temperatures decrease. Non-residential buildings in urban District focused on apartment buildings display similar by the daily and annual heat consumption patterns. Yet their daily and annual maximum load ratio differ according to outdoor temperature, District, building types and their composition ratio. In the case of urban District focused on apartment buildings reach optimum and maximum load ratio when apartment buildings reaches 60-70% of the total. At that point heat supply range becomes maximized and the most economic efficiency is obtained.

A Study of Nonpoint Source Pollutants Loads in Each Watershed of Nakdong River Basin with HSPF (HSPF 모델을 이용한 낙동강유역의 유역단위별 비점오염부하량 산정)

  • Kwon, Kwangwoo;Choi, Kyoung-sik
    • Journal of Environmental Impact Assessment
    • /
    • v.26 no.1
    • /
    • pp.68-77
    • /
    • 2017
  • In order to estimate the non-point pollution loads from each watersheds among 209 watersheds, the calibration and validation of HSPF model were carried out based on 2012 in 2013 years. In the case of flow rate, R2 of calibration and validation were 0.71~0.93 and 0.71~0.79, which were relatively good values. With the respect to calibration of water quality, % differences between measured and simulated values were 0.4 ~ 9.7 of DO, BOD 0.5 ~ 30.2% and TN 1.9~28.6% except for Hwhangkang B site. In case of validation, DO was 0.2 ~ 13.7%, BOD 1.3~23% and TN 0.5~24.3% excluding Hwhangkang B. However, since the concentration of TP was very small compared with other items, the range of difference was large as 0.8~55.3%. level. As the result of calculating annual accumulative BOD loads for each watershed, it was found that RCH 123 (Uryeong, Gyeongsangnamdo), RCH 121 (Jinju, Gyeongsangnamdo) and RCH 92 (Daegu) were the high ranked. The unit watersheds including various landuse type susch as forest and agricultural sites in mainstream areas have a higher BOD nonpoint pollution load than those in dam regions. However, the results of the annual cumulative loading of the basins for nutrients did not appear to be consistent with the BOD annual cumulative loading ranks. Other factors that represent watershed characteristics such as landslope and soiltypes, including landuse pattern, have been found to be closely related to nonpoint pollutant loads.

The Analysis of R&D Investment Factors for Enhancing the Regional Domestic Competitiveness in China (중국의 지역 내 경쟁력 제고를 위한 R&D 투자요인 분석)

  • Yoon, Daisang;Lee, Jinho;Park, Sang-Hyun
    • Journal of Korea Technology Innovation Society
    • /
    • v.20 no.3
    • /
    • pp.805-836
    • /
    • 2017
  • China has become the group of two (G2) in almost fields including the scientific technology following the economic growth and joining the WTO in 2001. The main reason is that the government had strong intention for the industrialization of the scientific technology and connected the scientific technology and the economy. Typically, for analyzing the cause of the meteoric rise of China, the competitiveness of the scientific technology was analyzed by the entire score of the nation. However, in the case of China, there are differences in the pattern of the development between the eastern, central, and western province. Also, the industrialization and the competitiveness of the scientific technology are difference because each province established the decentralization of power. Therefore, it is more meaningful to analyze the main factors of Chinese economic growth on a province unit. In this study, therefore, we analyzed the competitive of R&D in China by 124 indexes in 31 areas. The data was analyzed by Partial least squares regression analysis. In conclusion, the scale of the area and the ability of R&D of the company are very important factors for total amount of production in the area. And the journals, patents, the transfer of technical know-how and the investment of R&D are main factors of the amount of export on the high-tech product. According to these results, the factors which make the difference in the industrialization and the competitiveness of the scientific technology in China were analyzed. Finally, it will be helpful to establish the policy for the development of the industrialization and the scientific technology in Korea.

Effects of cooking method and final core-temperature on cooking loss, lipid oxidation, nucleotide-related compounds and aroma volatiles of Hanwoo brisket

  • Utama, Dicky Tri;Baek, Ki Ho;Jeong, Hae Seong;Yoon, Seok Ki;Joo, Seon-Tea;Lee, Sung Ki
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.31 no.2
    • /
    • pp.293-300
    • /
    • 2018
  • Objective: This study observed the effects of cooking method and final core temperature on cooking loss, lipid oxidation, aroma volatiles, nucleotide-related compounds and aroma volatiles of Hanwoo brisket (deep pectoralis). Methods: Deep pectoralis muscles (8.65% of crude fat) were obtained from three Hanwoo steer carcasses with $1^+$ quality grade. Samples were either oven-roasted at $180^{\circ}C$ (dry heat) or cooked in boiling water (moist heat) to final core temperature of $70^{\circ}C$ (medium) or $77^{\circ}C$ (well-done). Results: Boiling method reduced more fat but retained more moisture than did the oven roasting method (p<0.001), thus no significant differences were found on cooking loss. However, samples lost more weight as final core temperature increased (p<0.01). Further, total saturated fatty acid increased (p = 0.02) while total monounsaturated fatty acid decreased (p = 0.03) as final core temperature increased. Regardless the method used for cooking, malondialdehyde (p<0.01) and free iron contents (p<0.001) were observed higher in samples cooked to $77^{\circ}C$. Oven roasting retained more inosinic acid, inosine and hypoxanthine in samples than did the boiling method (p<0.001), of which the concentration decreased as final core temperature increased except for hypoxanthine. Samples cooked to $77^{\circ}C$ using oven roasting method released more intense aroma than did the others and the aroma pattern was discriminated based on the intensity. Most of aldehydes and pyrazines were more abundant in oven-roasted samples than in boiled samples. Among identified volatiles, hexanal had the highest area unit in both boiled and oven-roasted samples, of which the abundance increased as the final core temperature increased. Conclusion: The boiling method extracted inosinic acid and rendered fat from beef brisket, whereas oven roasting intensified aroma derived from aldehydes and pyrazines and prevented the extreme loss of inosinic acid.

Isolation of Bacillus subtilis GS-2 Producing γ-PGA from Ghungkukjang Bean Paste and Identification of γ-PGA (청국장으로부터 분리한 Poly(γ-glutamic acid)를 생산하는 균주 Bacillus subtilis GS-2의 분리 및 γ-PGA의 확인)

  • Bang, Byung-Ho;Jeong, Eun-Ja;Rhee, Moon-Soo;Kim, Yong-Min;Yi, Dong-Heui
    • Journal of Applied Biological Chemistry
    • /
    • v.54 no.1
    • /
    • pp.1-6
    • /
    • 2011
  • ${\gamma}$-PGA(poly-${\gamma}$-glutamic acid) is an unusual anionic polypeptide that is made of D- and L-glutamic acid units connected by amide linkages between ${\alpha}$-amino and ${\gamma}$-carboxylic acid groups. ${\gamma}$-PGA has been isolated from many kinds of organisms. Many Bacillus strains produce ${\gamma}$-PGA as a capsular material of an extracellular viscous material. It is safe for eating as a viscosity element of fermented soybean products such as Chungkookjang and Natto. It is biodegradable, edible and nontoxic toward humans and the environment and its molecular weight varies from ten thousand to several hundred thousand depending on the kinds of strains used. Therefore, potential applications of ${\gamma}$-PGA and its derivatives have been of interest in the past few years in a broad range of industrial fields such as food, cosmetics, medicine, water-treatment, etc. In this study, a bacterium, Bacillus subtilis GS-2 isolated from the Korean traditional seasoning food, Chungkookjang could produce a large amount of ${\gamma}$-PGA with high productivity and had a simple nutrient requirement. Based on carbon utilization pattern and partial 16S rRNA sequence analysis, the GS-2 strain was identified as B. subtilis. The determination of purified ${\gamma}$-PGA was confirmed with thin layer chromatography (TLC), high performance liquid chromatography (HPLC), fourier transform infrared (FT-IR) spectra, and $^1H$-nuclear magnetic resonance ($^1H$-NMR) spectroscopy.

Big Data Analysis for Public Libraries Utilizing Big Data Platform: A Case Study of Daejeon Hanbat Library (도서관 빅데이터 플랫폼을 활용한 공공도서관 빅데이터 분석 연구: 대전한밭도서관을 중심으로)

  • On, Jeongmee;Park, Sung Hee
    • Journal of the Korean Society for information Management
    • /
    • v.37 no.3
    • /
    • pp.25-50
    • /
    • 2020
  • Since big data platform services for the public library began January 1, 2016, libraries have used big data to improve their work performance. This paper aims to examine the use cases of library big data and attempts to draw improvement plan to improve the effectiveness of library big data. For this purpose, first, we examine big data used while utilizing the library big data platform, the usage pattern of big data and services/policies drawn by big data analysis. Next, the limitations and advantages of the library big data platform are examined by comparing the data analysis of the integrated library management system (ILUS) currently used in public libraries and data analysis through the library big data platform. As a result of case analysis, big data usage patterns were found program planning and execution, collection, collection, and other types, and services/policies were summarized as customizing bookshelf themes for the book curation and reading promotion program, increasing collection utilization, and building a collection based on special topics. and disclosure of loan status data. As a result of the comparative analysis, ILUS is specialized in statistical analysis of library collection unit, and the big data platform enables selective and flexible analysis according to various attributes (age, gender, region, time of loan, etc.) reducing analysis time. Finally, the limitations revealed in case analysis and comparative analysis are summarized and suggestions for improvement are presented.

Characteristics and Action Pattern of Polygalacturonase from Penicillium sp.CB-20 (Penicillium sp. CB-20이 생성하는 Polygalacturonase의 특성 및 작용양상)

  • Cho, Young-Je;Ahn, Bong-Jeon;Lim, Seong-Il;Lee, Woo-Je;Choi, Cheong
    • Microbiology and Biotechnology Letters
    • /
    • v.17 no.6
    • /
    • pp.580-586
    • /
    • 1989
  • Penicillium sp. CB-20 was selected for strong polygalacturonase activity among various strains of molds found in soil. The optimum pH for the enzyme activity was 5.0 and optimum temperature was 4$0^{\circ}C$. The enzyme was relatively stable in acidic condition and unstable by heat treatment. The activation energy, Km and V$_{max}$ for the polygalacturonase were 2.499 Kcal/mol, 2.13$\times$10$^{-2}$mol/l, and 104.17 $\mu$mol/min. The activity of polygalacturonase was inhibited by Ag$^{+}$, Cu$^{++}$, Pb$^{++}$, Fe$^{+++}$, $Ca^{++}$, Na$^+$, Mn$^{++}$. The enzyme can be inactivated by the treatment ethylenediamintetra acetic acid, 2,4-dinitrophenol and $H_2O$$_2$. The results indicate the possible involvement of histidine, chelate and terminal amino group as active site. The enzyme was endo-type polygalacturonase.

  • PDF

Variation of Pollutant Removal Efficiency and Backwashing Effect of BAC Basin in Advanced Water Treatment Processes (고도정수공정에서 오염물질 제거효율 변화특성과 BAC조의 역세척에 따른 영향)

  • Park, Soo-Yee;Lee, Sang-Bong;Sin, Sang-Min;Jun, Chang-Jea;Kim, Chang-Won
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.1
    • /
    • pp.45-53
    • /
    • 2008
  • In this paper, the property of influent water and variations of removal efficiencies in each unit processes were studied based on the experiment data from the advanced water treatment plant in a city of Korea. The microbial species in the biological activated carbon(BAC) after backwashing of activated carbon filtration tank(ACFT) were also identified. The property and the removal efficiencies were evaluated by considering 8-9 items. The variations of 4 items were investigated from the influent and effluent of ACFT. SEM recording were conducted on BAC samples before and after backwashing. And the existence of attached microorganisms were identified through HPC(Heterotrophic Plate Counter) investigation. For the property of influent water, the concentrations of most items were maintained in the constant ranges, some items had seasonal properties. For the removal efficiencies, there were some items showing similar monthly-pattern and increasing with time, other items decreasing at the ozone contactor. Through these investigations, it was possible to distinguish the target items, which were removed by the advanced processes. The existence of microorganisms in ACFT could be predicted based on the variation curve of NH$_3$-N, and this fact were proved by SEM and HPC.

Reliability Analysis of EMU Static Inverters considering Influence of Temperature Stress Factor (온도스트레스 영향을 고려한 전동차 보조전원장치의 신뢰성분석)

  • Park, Nam-Chul;Song, Joong-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.3
    • /
    • pp.493-500
    • /
    • 2017
  • Based on the data accumulated through EMU fault management, this paper examines the reliability of old railway car parts and proposes measurements to improve safety. Subway Line 7 of the Seoul Metropolitan Rapid Transit Corporation, auxiliary power unit (Static Inverter) of the EMU second version is a core equipment to supply power to various room-service units in cars and make an effect directly on passenger satisfaction. To analyze the pattern of failure throughout the field data over a long period of time, this analysis of statistics and reliability considers the operating environment and stress factors. This statistical analysis presents the correlation between failure and the temperature stress factors related to frequent failure occurring intensively in summer. In addition, throughout the analysis of the life of the IGBT inverter, the effect of the temperature stress factor was observed before and after the repair. As a result of an analysis of the optimal operating conditions considering two variations of EMU, such as variable load and outside temperature, a difference in the cooling capacity between the optimal operating conditions and frequent failure conditions was observed. Based on this analysis, this paper suggests a way to minimize cooling capacity difference for the optimal operational conditions.