• Title/Summary/Keyword: Pattern identification: Reliability

Search Result 81, Processing Time 0.029 seconds

Development of a Phlegm Pattern Questionnaire for Functional Dyspepsia and Analysis of Its Reliability and Validity (기능성소화불량에 대한 담음 변증설문지 개발과 신뢰도 및 타당도 검정)

  • Baek, So-young;Ha, Na-yeon;Ko, Seok-jae;Park, Jae-woo;Kim, Jin-sung
    • The Journal of Internal Korean Medicine
    • /
    • v.41 no.4
    • /
    • pp.563-582
    • /
    • 2020
  • Objectives: The aim of this study was to develop a Phlegm Pattern Questionnaire for Functional Dyspepsia (PPQ-FD) by modifying a previously developed Phlegm Pattern Questionnaire (PPQ) and to verify its reliability and validity. Further objectives were to obtain the optimal cut-off value for the PPQ-FD for standardization and for clinical use. Methods: The PPQ-FD was developed by extracting the major symptoms of the phlegm pattern in functional dyspepsia and by using the Delphi method to administer a requested importance survey to experts. The reliability, validity, and optimal cut-off value of the PPQ-FD were analyzed by enrolling a total of 60 subjects in this study. Thirty patients were diagnosed with both functional dyspepsia and phlegm pattern and thirty patients were diagnosed with only functional dyspepsia. All participants were requested to fill out the PPQ-FD. Results: No statistically significant differences were detected in the two groups for sex distribution, age, or body mass index. Five of the survey questions negatively affected its reliability; therefore, we decided to exclude those five questions on further inspection. The Cronbach's α coefficient of the revised PPQ-FD was 0.853, and clinical validity was verified. Construct validity was analyzed by factor analysis and identified four factors. Statistically significant positive correlations were found between the revised PPQ-FD and other dyspepsia scales, such as the SQDQ, SSQD, VAS, NDI-K, and FD-QoL scales. The VAS had particularly strong positive correlations with the PPQ-FD. Conclusions: The PPQ-FD developed in this study has fundamental reliability and validity for use as a pattern-diagnosis questionnaire. The PPQ-FD can help to diagnose the phlegm pattern in patients with functional dyspepsia.

Development of a Food Retention Questionnaire for Functional Dyspepsia and the Analysis of Its Reliability and Validity (기능성소화불량의 식적설문지 개발과 신뢰도 및 타당도 검정)

  • Hwang, Mi-ni;Ha, Na-yeon;Ko, Seok-jae;Park, Jae-woo;Kim, Jin-sung
    • The Journal of Internal Korean Medicine
    • /
    • v.40 no.3
    • /
    • pp.390-408
    • /
    • 2019
  • Objectives: Several pattern diagnosis questionnaires have been developed to objectify the process of pattern diagnosis in Korean medicine. In this context, this study aimed to develop a food retention questionnaire for functional dyspepsia (FRQ-FD) by modifying the previously developed food retention questionnaire (FRQ) and to verify its reliability and validity. Furthermore, this study aimed to identify the optimal cut-off value of the FRQ-FD for standardization and use in clinical situations. Methods: To develop the FRQ-FD, we extracted the major symptoms of food retention pattern for functional dyspepsia from Chinese/Korean medicine textbooks and requested an importance survey from experts using the Delphi method. The first draft of the FRQ-FD was composed of 25 questions comprising 8 questions from the textbooks and the Delphi method and 17 questions from the FRQ already developed in 2013. To analyze its reliability, validity, and optimal cut-off value, 60 subjects were enrolled in this study from June 25 to August 13, 2018. Thirty patients were diagnosed as both functional dyspepsia and food retention pattern, and 30 healthy participants were not. All participants were requested to fill up the FRQ-FD, Stomach Qi Deficiency Questionnaire (SQDQ), Scale for Stomach Qi Deficiency pattern (SSQD), visual analog scale (VAS) for dyspepsia, Nepean Dyspepsia Index-Korean version (NDI-K), and functional dyspepsia-related quality of life (FD-QoL). Results: No statistically significant differences were found in sex distribution, age, and body mass index between the patient group and the control group. As five questions affected the reliability negatively and three questions affected the clinical validity negatively, we decided to exclude the eight questions upon further investigation. The Cronbach's ${\alpha}$ coefficient of the revised FRQ-FD (17 items) was 0.899, and its clinical validity was verified. Construct validity was analyzed by factor analysis and produced five factors. Statistically significant positive correlations were found between the revised FRQ-FD and the other dyspepsia scales, namely, SQDQ, SSQD, VAS, NDI-K, and FD-QoL. VAS and NDI-K especially had strong positive correlations with FRQ-FD. Conclusions: The FRQ-FD developed in this study can provide fundamental reliability and validity for a pattern diagnosis questionnaire. FRQ-FD can help to diagnose food retention pattern in functional dyspepsia patients. Further studies are required to inspect several statistical factors.

Research of Pattern identification and Outcome Measurement in Atopic Dermatitis (아토피피부염의 변증과 평가방법에 대한 고찰)

  • Son, Byeong-Kook;Choi, In-Hwa
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.21 no.3
    • /
    • pp.150-165
    • /
    • 2008
  • Objective : An adequate measurement for Atopic Dermatitis(AD) is essential for studies about the treatment of AD. To establish a new and adequate scoring system for AD in Korean medicine, we reviewed existing studies on AD outcome measurement in Korean medicine. Method : We searched for reviews on measurements of AD or studies which used an AD outcome measurement at the Korean Traditional Knowledge Portal from 1995 to June, 2008. And then we reviewed the pattern identification in AD patients and the outcome measurements for AD in each study. Results : 1. Among 25 studies, the most common measurement for AD was SCORAD(the severity SCORing of Atopic Dermatitis index), there were 16 studies. There was one study which used the Jakob T scoring system, one study which used ADSI(the Atopic Dermatitis Severity Index), and there were 7 studies which established or used a new severity scoring system for AD. 2. In Korean medicine, AD caused by Damp-Heat is accompanied by erythema, papulation, oozing and crust, Damp-Heat accompanied by Spleen-Gi deficiency is frequently found in pediatric patients, and in adults who have indigestion. Symptoms of AD caused by blood deficiency and Wind-Dryness include lichenification, dryness, scale and pigmentation. AD caused by toxic Heat in the blood system has symptoms similar to some Damp-Heat pattern along with symptoms of blood deficiency and Wind-Dryness. Conclusion : We need to establish a new severity scoring system which reflects pattern identifications and treatments with Korean medicine, and we should assess the validity, reliability, and sensitivity of the new scoring system.

  • PDF

System Engineering Interfaces of Reliability Engineering in Development of Launch Vehicle (우주발사체 개발사업에서 신뢰성공학의 시스템엔지니어링 인터페이스)

  • Shin, Myoung Ho;Cho, Sang Yeon;Joh, Miok
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.2 no.1
    • /
    • pp.31-36
    • /
    • 2006
  • Development of launch vehicle needs a large-scale and complicated System Engineering discipline interfacing to small-quantity production with special manufacturing processes. In general, the System Engineering discipline of launch vehicle has its relationship with Production, Operations, Product Assurance and Management disciplines and its internal partitions into the functions of System Engineering Integration & Control, Requirements Engineering, Analysis, Design and Configuration and Verification. As a function of Product Assurance, reliability of launch vehicle plays an significant role in risk management, system safety, flight safety and launch certification through design assurance. Moreover, major functions of systems engineering are integrated by means of reliability in the phases of design and verification. Therefore, derailed identification of system engineering interfaces of reliability, and execution of tasks for reliability assurance is required for successful development of launch vehicle. This paper identifies specific pattern and mechanism of the interfaces between reliability and system engineering.

  • PDF

Prediction of Deficiency Pattern in Diabetic Patients Using Multi-frequency Bioimpedance Resistance (다주파수 생체임피던스 저항을 이용한 당뇨병 환자의 허증 변증 예측)

  • Kim, Kahye;Kim, Seul Gee;Cha, Jiyun;Yoo, Ho-Ryong;Kim, Jaeuk U.
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.36 no.3
    • /
    • pp.94-99
    • /
    • 2022
  • The discovery of biomarkers related to pattern identification (PI), the core diagnostic theory of Korean medicine (KM), is one of the methods that can provide objective and reliable evidence by applying PI to clinical practice. In this study, 40 diabetic patients and 41 healthy control subjects recruited from the Korean medicine clinic were examined to determine the human electrical response related to the deficiency pattern, a representative pattern of diabetes. Qi-Blood-Yin-Yang deficiency pattern scores, which are representative deficiency patterns for diabetes mellitus, were obtained through a questionnaire with verified reliability and validity, and the human electrical response was measured non-invasively using a bioimpedance meter. In ANCOVA analysis using gender as a covariate, the 5 kHz frequency resistance and 5-250 kHz frequency reactance were significantly lower in the diabetic group than in non-diabetic control group. In addition, the multiple regression analysis showed a positive correlation (R2=0.11~0.19) between the Yang deficiency pattern score and resistance value for the diabetic group; the correlation was higher at higher frequencies of 50kHz (R2=0.18) and 250kHz (R2=0.19) compared to 5kHz(R2=0.11). In contrast, there was no such significant association in the control group. It implies that bioimpedance resistance measured at finite frequencies may be useful in predicting Yang deficiency, which is closely related to diabetic complications by reflecting the decrease in body water content and metabolism. In the future, large-scale planned clinical studies will be needed to identify biomarkers associated with different types of PI in diabetes.

Iris Recognition Using a Modified CPN (CPN을 이용한 홍채 인식)

  • Hong, Jin-Il;Yang, Woo-Suk
    • Journal of IKEEE
    • /
    • v.6 no.1 s.10
    • /
    • pp.10-20
    • /
    • 2002
  • The purpose of this work is to develop a system fer rapid and automatic identification of persons, with high reliability and confidence levels. The iris of the eye is used as an optical fingerprint, having a highly detailed pattern that is unique for each individual and stable over many years. Image analysis algorithms find the iris in a image, and encode its texture into an iris code. Iris texture is extracted from the image at multiple scales of analysis by wavelet transformation. The features of many different parts of the iris are projected onto the space-frequency space. They are used to determine an abstract iris code which is similar to 2D barcode. Pattern recognition is achieved by using modified CPN.

  • PDF

Robust Watermarking for Compressed Video Using Fingerprints and Its Applications

  • Jung, Soo-Yeun;Lee, Dong-Eun;Lee, Seong-Won;Paik, Joon-Ki
    • International Journal of Control, Automation, and Systems
    • /
    • v.6 no.6
    • /
    • pp.794-799
    • /
    • 2008
  • This paper presents a user identification method at H.264 streaming using watermarking with fingerprints. The watermark can efficiently reduce the potential danger of forgery or alteration. Especially a biometric watermark has convenient, economical advantages. The fingerprint watermark can also improve reliability of verification using automated fingerprint identification systems. These algorithms, however, are not robust against common video compression. To overcome this problem, we analyze H.264 compression pattern and extract watermark after restoring damaged watermark using various filters. The proposed algorithm consists of enhancement of a fingerprint image, watermark insertion using discrete wavelet transform and extraction after restoring. The proposed algorithm can achieve robust watermark extraction against H.264 compressed videos.

A Study on the Sasang Constitutional Diagnosis by Perceptual Voice Analysis (청각적(聽覺的) 성음분석(聲音分析)을 통한 사상체질진단(四象體質診斷)에 관한 연구(硏究))

  • Yoo, Jun-Sang;Kim, Dal-Rae
    • Journal of Sasang Constitutional Medicine
    • /
    • v.16 no.3
    • /
    • pp.46-58
    • /
    • 2004
  • 1. Objectives This study was performed by means of perceptual evaluation of the voices of Sasang Constitution. 2. Methods 73 female subjects were classified by means of 3 kinds of Questionnaire papers(QSCCII, QSCCI, Sasang Pattern Identification Questionnaire). So they were categorized into 3 groups, 23 Soyangin, 28 Taeumin and 22 Soeumin. 73 voice samples were presented three times to a group of 5 judges. The time interval between ratings was 14 days. The four goals of this study were to evaluate the intraobserver reliability between each rating, to evaluate the interobserver reliability, to evaluate the reliability between the each rating and Questionnaire result and to make the notion of the consensus of Sasang Constitution's Voice. 3. Results & Conclusions The intraobserver reliability between the first and second rating showed significance statistically among all observers. And the intraobserver reliability between the second and third rating showed significance except one observer. The interobserver reliability among the three ratings showed significance statistically except one to two observers in the first rating and other one to another one in the second rating. In the reliability between the each rating and Questionnaire result, one in the first rating, other one in the second rating and another two in the third rating showed significance. To make the notion of the consensus of Sasang Constitution's Voice, classification into 4 categories was made: clear/hoarse, high/low, fast/slow, powerful/powerless. The voice of Soyangin group was classified as powerful and fast, and that of Taeumin group as powerful, hoarse and low and that of Soeumin group as powerless and slow.

  • PDF

Extraction of Iris Codes for Personal Identification Using an Iris Image (홍채를 이용한 생체인식 코드 추출)

  • Yang, Woo Suk
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.8 no.6
    • /
    • pp.1-7
    • /
    • 2008
  • In this paper, we introduce a new technology to extract the unique features from an iris image, which uses scale-space filtering. Resulting iris code can be used to develop a system for rapid and automatic human identification with high reliability and confidence levels. First, an iris part is separated from the whole image and the radius and center of the iris are evaluated. Next, the regions that have a high possibility of being noise are discriminated and the features presented in the highly detailed pattern are then extracted. In order to conserve the original signal while minimizing the effect of noise, scale-space filtering is applied. Experiments are performed using a set of 272 iris images taken from 18 persons. Test results show that the iris feature patterns of different persons are clearly discriminated from those of the same person.

  • PDF

A Study on Color Reliability of New Combat Uniform Fabrics through Quantitative Analysis of the Color and Color Fastness to Washing (색상 및 세탁견뢰도의 정량적 분석을 통한 신형 전투복 원단의 색상신뢰성 연구)

  • Hong, Seong-don;Kim, Byung-Soon;Jang, Yeonju;Lee, Jung Soon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.40 no.3
    • /
    • pp.456-464
    • /
    • 2016
  • A new combat uniform is improved for added combat safety with various functions such as survivability, battle conformity and a camouflage performance system. Camouflage performance is an important factor in terms of combat survivability since it makes identification difficult and provide security. The combat uniform is worn under extreme conditions (exposure to ultraviolet light, sweat and friction) and an excellent color fastness to repeated washing is required. In this study, we investigated the color management, durability and discoloration of new combat uniform fabric with a digital pattern for camouflage performance to provide preliminary color management data. We examined color differences between standard fabric and mass-produced combat uniform fabrics, color differences between each military supply contract firm and color changes in combat uniforms after 60 washing cycles. The slight color differences between standard fabric and mass-produced combat uniform fabrics were tolerable under quality criteria of Republic of Korea Ministry of National Defense. However, the differences between the military supply contract firms were recognizable to the naked eye and increased with repeated washing. Continuous research on color fastness under repeated washing and color management is required to standardize reliability from each military supply contract firm for the daytime performance of a combat uniform's camouflage.