• 제목/요약/키워드: Patrix

검색결과 4건 처리시간 0.016초

WEAR BEHAVIOR OF ATTACHMENTS FOR IMPLANT RETAINED OVERDENTURE ACCORDING TO MATERIAL IN VITRO

  • Lee Seok-Hyung
    • 대한치과보철학회지
    • /
    • 제41권6호
    • /
    • pp.747-761
    • /
    • 2003
  • Statement of problem. The proper materials of attachments for implant retained overdenture are unknown, such as the correlation between retention and abrasion, as well as the types of materials that are suitable for patrix and for matrix individually. Purpose of this study. The aim of this study was to select a proper clinical attachment system for a successful treatment as well as patient satisfaction. Methods. Retention and abrasion of 14 commercial attachments were measured during 15,000 removes. Results. A retentive part (matrix) which requires elasticity has to be made of gold while the patrix part which does not require elasticity has to be made of titanium. This gold matrix / titanium patrix combination showed the most retentive force and the least retention loss.

Effect of implant- and occlusal load location on stress distribution in Locator attachments of mandibular overdenture. A finite element study

  • Alvarez-Arenal, Angel;Gonzalez-Gonzalez, Ignacio;deLlanos-Lanchares, Hector;Martin-Fernandez, Elena;Brizuela-Velasco, Aritza;Ellacuria-Echebarria, Joseba
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권5호
    • /
    • pp.371-380
    • /
    • 2017
  • PURPOSE. The aim of this study is to evaluate and compare the stress distribution in Locator attachments in mandibular two-implant overdentures according to implant locations and different loading conditions. MATERIALS AND METHODS. Four three-dimensional finite element models were created, simulating two osseointegrated implants in the mandible to support two Locator attachments and an overdenture. The models simulated an overdenture with implants located in the position of the level of lateral incisors, canines, second premolars, and crossed implant. A 150 N vertical unilateral and bilateral load was applied at different locations and 40 N was also applied when combined with anterior load at the midline. Data for von Mises stresses in the abutment (matrix) of the attachment and the plastic insert (patrix) of the attachment were produced numerically, color-coded, and compared between the models for attachments and loading conditions. RESULTS. Regardless of the load, the greatest stress values were recorded in the overdenture attachments with implants at lateral incisor locations. In all models and load conditions, the attachment abutment (matrix) withstood a much greater stress than the insert plastic (patrix). Regardless of the model, when a unilateral load was applied, the load side Locator attachments recorded a much higher stress compared to the contralateral side. However, with load bilateral posterior alone or combined at midline load, the stress distribution was more symmetrical. The stress is distributed primarily in the occlusal and lateral surface of the insert plastic patrix and threadless area of the abutment (matrix). CONCLUSION. The overdenture model with lateral incisor level implants is the worst design in terms of biomechanical environment for the attachment components. The bilateral load in general favors a more uniform stress distribution in both attachments compared to a much greater stress registered with unilateral load in the load side attachments. Regardless of the implant positions and the occlusal load application site, the stress transferred to the insert plastic is much lower than that registered in the abutment.

임플란트 bar 어태치먼트에 사용하는 두 가지 부가적인 유지장 치의 유지력 특성 비교 (Comparison of the retentive characteristics of two additional attachment used with an implant bar attachment)

  • 최재원;채성기;허중보
    • 대한치과보철학회지
    • /
    • 제59권2호
    • /
    • pp.173-180
    • /
    • 2021
  • 목적: 본 연구는 반복적인 착탈에 따른 임플란트 bar 어태치먼트에 사용하는 두 가지 부가적인 유지장치의 유지력 특성을 평가해보고자 하였다. 재료 및 방법: 본 연구에서는 새롭게 개발된 유지장치(ADD-Lock; AL)와 기존의 상용화된 유지장치(Locator blue; LB)의 두 가지 유지장치를 평가하였다. 두 개의 고정체를 하부 구조물에 평행하게 위치시키고, 각 유지장치의 patrix를 고정체에 연결하였다. 각 유지장치의 matrix는 대합되는 상부 구조물에 위치시키고 고정하였다. Universal testing machine을 이용하여 초기, 100, 250, 500, 1000, 2000, 2500회의 반복적인 착탈 동안에 각 유지장치의 유지력을 측정하였다. 유지장치의 마모 및 변형 정도는 주사전자현미경으로 관찰하였다. Kruskal-Wallis test, Mann-Whitney U test (α = .05), 그리고 wilcoxon signed-rank test (α = .05)를 이용하여 통계분석 실시하였다. 결과: 초기 유지력과 2500회의 반복적인 착탈 후 유지력에서, AL군(15.24 ± 1.46 N, 9.74 ± 1.16 N)은 LB군(43.53 ± 12.39 N, 22.99 ± 4.77 N)보다 유의하게 작은 값을 보였다(P < .05). 또한, 유지력 소실량에 있어서도 AL군(5.50 ± 1.08 N, 36.08%)이 LB군(20.54 ± 11.89 N, 47.19%)에 비해 낮은 값을 보였다(P < .05). 주사전자현미경 분석 결과, AL군은 patrix에서, LB군은 matrix에서 눈에 띄는 마모 및 변형이 관찰되었다. 결론: Locator는 새롭게 개발된 유지장치보다 높은 초기 유지력을 보인 반면 높은 유지력 소실량을 보였다. 한편, 두 가지 부가적인 유지장치는 반복적인 착탈 후에도 충분한 유지력을 가지는 것으로 나타났다.

임플란트 피개의치를 위한 개별유지형 어태치먼트의 유지력에 관한 연구 (A Study on the Retentive Force of Stud Attachments for Implant Overdenture)

  • 송은주;배은빈;최재원;배지현;김지영;이소현
    • 치위생과학회지
    • /
    • 제16권1호
    • /
    • pp.93-100
    • /
    • 2016
  • 이번 연구에서는 두 종류의 어태치먼트 시스템인 Kerator와 O-ring의 다양한 유지력을 가지는 matrix를 사용한 반복적인 착탈 후 평가를 통해 다음과 같은 결론을 얻었다. 초기 유지력은 KP군($62.09{\pm}6.00N$)에서 높았으며, 이어서 KR군($32.83{\pm}4.40N$), KB군($12.69{\pm}3.32N$), OO군($9.55{\pm}1.33N$), 그리고 OR군($9.35{\pm}0.71N$) 순으로 나타났다. 유지력 소실량은 KP군($22.26{\pm}8.02N$)에서 가장 높았으며, KR군($6.23{\pm}3.04N$), OO군($6.03{\pm}1.24N$), OR군($5.81{\pm}0.73N$), 그리고 KB군($0.87{\pm}1.46N$) 순으로 나타났다. 각 군 내의 초기 유지력과 2,500회의 착탈 후의 최종 유지력을 비교하였을 때, KB군을 제외한 모든 군에서 유의한 차이를 보였다(p<0.05). 어태치먼트 표면 마모양상은 Kerator와 O-ring의 matrix에서 눈에 띄는 변형과 손상이 관찰되었다. 각 patrix에서는 유지력 소실에 기여할 만한 변화는 관찰되지 않았다. 결론적으로 어태치먼트의 종류, 재료 그리고 초기 유지력 차이에 따라 마모양상이나 유지력 소실에 차이가 있음을 확 인하였고, 유지력이 보존되는 것처럼 보여도 SEM으로 관찰하였을 때 어태치먼트의 내부가 상당히 변형된 경우가 많았다. 따라서 적절한 유지력을 가진 어태치먼트를 선택하고 각 어태치먼트 시스템 별 적절한 교체시기를 숙지하여 그에따른 사용기간의 준수가 필요할 것으로 생각된다.