• Title/Summary/Keyword: Patients with cancer

Search Result 9,669, Processing Time 0.047 seconds

Comparison of Tc-99m-Tetrofosmin and Tc-99m-MIBI Scintimammography in Differential Diagnosis of Breast Mass (유방종양의 감별진단에서 Tc-99m-Tetrofosmin과 Tc-99m-MIBI 유방신티그라피의 비교)

  • Park, Jung-Mi;Choi, Joon-Young;Lee, Kyung-Han;Choi, Yong;Choe, Yearn-Seong;Kim, Sang-Eun;Kim, Byung-Tae;Nam, Seok-Jin;Yang, Jeong-Hyun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.5
    • /
    • pp.393-402
    • /
    • 2000
  • Purpose: Tc-99m-MIBI (MIBI) and Tc-99m-Tetrofosmin (TF) are commonly used for scintimammog (SMM). We compared the diagnostic ability of SMM using Tc-99m-MIBI and Tc-99m-TF for the diagnosis of breast mass. Materials and Methods: The study subjects were comprised of 123 breast lesior 86 normal breasts of 114 patients who underwent SMM. Bilateral prone images and anterior supine images obtained at 5 minutes and 1 or 3 hours after intravenous injection of 740 MBq of either MIBI or TF. of tumors were not significantly different between the MIBI and TF groups. First, two observers read the SMM without clinical information (1st interpretation), then read again with information about location (2nd interpretation). Sensitivity and specificity of each radiopharmaceutical for the diagnosis of cancer were evaluated in terms of image acquisition time, tumor size, and location. Results: The SMM a good agreement between two observers for 1st and 2nd interpretation, except for TF SMM at 3 hr. first interpretation, the sensitivities at 5 min, 1 hr, and 3 hr were not significantly different between MIBI TF SMM (81.6%, 80.0%, 60.9% in MIBI vs. 88.9%, 80.6%, 42.9% in TF), although the sensitivities of images were significantly lower than 5 min images in both MIBI and TF SMM. The specificity of TF at was superior to that of MIBI (81.5%, 90.0%, 82.9% in MIBI vs. 96.7%, 100%, 90.0% in TF, p<0.01 MIBI TF at 5 min). For the second interpretation with information of mass location, the sensitivities at 3 hr were significantly lower than 5 min images (86.8%, 86.7%, 78.3% in MIBI vs. 88.9%, 93.5%, 57.1% between MIBI and TF SMM. However, there was no significant difference in the specificity (60.0%, 75.0% for MIBI vs. 86.7%, 100%, 100% for TF). MIBI and TF SMM showed lower sensitivities for the with less than 1 cm than tumors with more than 1 cm. However, the location of tumors did not sensitivity and specificity between MIBI and TF SMM. Conclusion: The ability for the differential of breast tumor is similar between MIBI and TF SMM, and delayed image is not necessary. TF may be than MIBI considering the specificity of SMM without clinical information and labeling convenience.

  • PDF

Feasibility of Mixed-Energy Partial Arc VMAT Plan with Avoidance Sector for Prostate Cancer (전립선암 방사선치료 시 회피 영역을 적용한 혼합 에너지 VMAT 치료 계획의 평가)

  • Hwang, Se Ha;NA, Kyoung Su;Lee, Je Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.32
    • /
    • pp.17-29
    • /
    • 2020
  • Purpose: The purpose of this work was to investigate the dosimetric impact of mixed energy partial arc technique on prostate cancer VMAT. Materials and Methods: This study involved prostate only patients planned with 70Gy in 30 fractions to the planning target volume (PTV). Femoral heads, Bladder and Rectum were considered as oragan at risk (OARs). For this study, mixed energy partial arcs (MEPA) were generated with gantry angle set to 180°~230°, 310°~50° for 6MV arc and 130°~50°, 310°~230° for 15MV arc. Each arc set the avoidance sector which is gantry angle 230°~310°, 50°~130° at first arc and 50°~310° at second arc. After that, two plans were summed and were analyzed the dosimetry parameter of each structure such as Maximum dose, Mean dose, D2%, Homogeneity index (HI) and Conformity Index (CI) for PTV and Maximum dose, Mean dose, V70Gy, V50Gy, V30Gy, and V20Gy for OARs and Monitor Unit (MU) with 6MV 1 ARC, 6MV, 10MV, 15MV 2 ARC plan. Results: In MEPA, the maximum dose, mean dose and D2% were lower than 6MV 1 ARC plan(p<0.0005). However, the average difference of maximum dose was 0.24%, 0.39%, 0.60% (p<0.450, 0.321, 0.139) higher than 6MV, 10MV, 15MV 2 ARC plan, respectively and D2% was 0.42%, 0.49%, 0.59% (p<0.073, 0.087, 0.033) higher than compared plans. The average difference of mean dose was 0.09% lower than 10MV 2 ARC plan, but it is 0.27%, 0.12% (p<0.184, 0.521) higher than 6MV 2 ARC, 15MV 2 ARC plan, respectively. HI was 0.064±0.006 which is the lowest value (p<0.005, 0.357, 0.273, 0.801) among the all plans. For CI, there was no significant differences which were 1.12±0.038 in MEPA, 1.12±0.036, 1.11±0.024, 1.11±0.030, 1.12±0.027 in 6MV 1 ARC, 6MV, 10MV, 15MV 2 ARC, respectively. MEPA produced significantly lower rectum dose. Especially, V70Gy, V50Gy, V30Gy, V20Gy were 3.40, 16.79, 37.86, 48.09 that were lower than other plans. For bladder dose, V30Gy, V20Gy were lower than other plans. However, the mean dose of both femoral head were 9.69±2.93, 9.88±2.5 which were 2.8Gy~3.28Gy higher than other plans. The mean MU of MEPA were 19.53% lower than 6MV 1 ARC, 5.7% lower than 10MV 2 ARC respectively. Conclusion: This study for prostate radiotherapy demonstrated that a choice of MEPA VMAT has the potential to minimize doses to OARs and improve homogeneity to PTV at the expense of a moderate increase in maximum and mean dose to the femoral heads.

Measurement of Radiation Using Tissue Equivalent Phantom in ICR Treatment (자궁강내 근접방사선조사시 인체조직등가 팬톰을 이용한 방사선량 측정)

  • Jang, Hong-Seok;Suh, Tae-Suk;Yoon, Sei-Chul;Ryu, Mi-Ryeong;Bahk, Yong-Whee;Shinn, Kyung-Sub
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.1
    • /
    • pp.45-52
    • /
    • 1995
  • This study is to compare A point doses in human pelvic phantom by film dosimetry, computer planning and manual calculation by using of along-away table. We developed tissue equivalent human pelvic phantom composed of four pieces of cylindrical acryl tubes with water, to simulate intracavitary radiation (ICR) in patients with cervix cancer. When the phantom assembled from 4 pieces, it has a small space for inserting Fletcher-Suit-Delclos applicator like a human vagina. Fletcher-Suit-Delclos applicator inserted into the space was packed tightly with furacin gauzes, and three $^{137}Cs$ sources with radioactivity of $15.7mg\;Ra-eq$ were inserted into the tandem. For the film dosimetry, two pieces of X-OMAT V film (Kodak Co.) of which planes include point A, were arranged orthogonally in the slits between phantoms. A point dose and iso-dose curves were measured by means of optical densitometer. A point doses by film dosimetry, RTP system and manual calculation by using of along-away table were compared, and iso-dose curves by film dosimetry and computer planning were also compared. The dose of A point was 51.2cGy/hr by film dosimetry, 46.7cGy/hr by RTP system and 47.9 cGy/hr by along-away table. A point dose by computer planning was similar to the dose by calculation using of along-away table with acceptable accuracy $({\pm}3%)$, however, the dose by film dosimetry was different from two others with about 10% error. Since most clinical beams contains a scatter component of low energy photons, the correlation between optical density and dose becomes tenuous. In addition, film suffers from several potential errors such as changes in processing conditions, interfilm emulsion differences, and artifacts caused by air pockets adjacent to the film. For these reasons, absolute dosimetry with film is impractical, however, it is very useful for checking qualitative patterns of a radiation distribution. In future, solid state dosimeter such as TLD must be used for the dosimetry of ionizing radiation. When considerable care is used, precision of approximately 3% may be obtained using TLD.

  • PDF

Comparison of Dosimetric Parameters of Patient with Large and Pendulous Breast Receiving Breast Radiotherapy in the Prone versus Supine Position (유방 크기가 큰 유방암 환자의 방사선 치료 시 환자의 자세에 따른 선량 비교)

  • Moon, Sun Young;Yoon, Myonggeun;Chung, Weon Kuu;Chung, Mijoo;Shin, Dong Oh;Kim, Dong Wook
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.234-240
    • /
    • 2015
  • The purpose of this study is to analyze dosimetric parameters of patient with large and pendulous breast receiving breast radiotherapy in the prone versus supine position. The patient underwent computed tomography simulation in both prone and supine position. The homogeneity index (HI), conformity index (CI), coverage index (CVI) to the left breast as planning target volume (PTV) and the doses to the lung, heart, and right breast as organ at risk (OAR) were compared by using dose-volume histogram. The lifetime attributable risk (LAR) according to the prone and supine position was measured for the lung and right breast. The HI, CI of the PTV decreased 21.7%, 6.49%, respectively and the CVI increased 10.8% with the prone position. The mean and maximum dose to the left lung decreased 91.6%, 87.0%, respectively and the volume parameters also decreased over 99% with the prone position. The parameters to the right lung were same regardless of the position. The mean and maximum dose to the heart decreased 51.6%, 14.2% with the prone position. But the mean and maximum dose to the right breast increased unlike the other OARs. The LARs to the lung decreased 80.3% (left), 24.2% (right) but the LAR to the right breast doubled with the prone position. The prone position is a favorable alternative for irradiation of breast in patients with large and pendulous breasts.

Clinical Significance of Incidental Asymmetric Palatine Tonsillar Uptake on $^{18}F$-FDG PET/CT ($^{18}F$-FDG PET/CT에서 우연히 관찰되는 구개편도의 비대칭적 섭취증가의 임상적 의의)

  • Chae, Sun-Young;Baek, So-Ra;Ryu, Jin-Sook;Moon, Dae-Hyuk;Kim, Jae-Seung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.5
    • /
    • pp.402-410
    • /
    • 2009
  • Purpose: The aim of this study was to determine the incidence and malignant rate of incidental asymmetric palatine tonsillar uptake (ATU) on $^{18}F$-FDG PET/CT in various clinical indications and to evaluate the clinical and PET/CT findings suggesting malignancy. Materials and Methods: We retrospectively reviewed a total of 2,901 patients ($58.4{\pm}12.3$ yrs, range 20~88 yrs, M:F = 1,841:1,060) who underwent $^{18}F$-FDG PET/CT during an 1-year period with various indications except primary tonsillar cancer and lymphoma evaluation. On $^{18}F$-FDG PET/CT, metabolic abnormality of the palatine tonsil and cervical lymph node were visually assessed. ATU was defined as increased palatine tonsillar uptake with diffuse, focal, or irregular pattern compared to contralateral side. The incidence and malignant ratio of ATU were evaluated according to clinical and PET/CT findings. Results: Of 2,901 cases, 290(10,0%) showed ATU. The incidence of ATU showed seasonal variation and was high in the winter (12.1%). Of 209 cases with ATU confirmed pathologically and/or clinically, five (2.4%) were malignant lesions. ATU with irregular uptake pattern (2/2) and in cases referred for cervical lymph node metastasis of unknown origin (3/5) were frequently associated with malignant lesion (p<0.05). Conclusion: ATU was not infrequently observed on $^{18}F$-FDG PET/CT, and the malignant risk of ATU was low. However, ATU with cervical lymph node metastasis or with irregular pattern on PET/CT would be further evaluated by the histopathologic examination.

Meta-Analysis about Effect of Aromatherapy on Stress (향기요법이 스트레스에 미치는 효과에 대한 메타 분석)

  • Kim, Gyung-Duck;Suh, Soon-Rim
    • Journal of Hospice and Palliative Care
    • /
    • v.11 no.4
    • /
    • pp.188-195
    • /
    • 2008
  • Purpose: The purpose of this study was to analyze the effects of aromatherapy on stress using meta-analysis. Methods: Meta-analysis was done with 21 published studies, and data were analyzed with the SAS 9.1 program. Results: Fifty eight effect size was estimated with data from 21 published studies. Overall mean effect size (ES), and mean effect size of dependence variables according to the type of intervention and subject and according to the total amount of time spent in aromatherapy were estimated. Overall mean effect size of the effects of aromatherapy was .593, and the subjective stress (.983) was most effective in the physiological faculty, followed by mean effect size of cortisol (.648) and pulse (.40). On the other hand, mean effect size of systolic blood pressure (.490) was moderate, and that of diastolic blood pressure (.401) was not large. Mean effect size of elderly (.706) cancer patients was considerable(.337). There were significant differences depending on the subjects. With regards to the types of aromatherapy, the effect size of aroma massage combined with inhalation therapy was .590, and there were no significant differences between the intervention methods. With regards to the time of intervention, $20{\sim}30$ minutes spent in aromatherapy was .730, and there were no significant differences between the times of intervention. The relationship between the effect size and intervention frequency was r=.349 and showed significant difference. Conclusion: This result suggests that aromatherapy is an effective intervention to reduce stress for subjects. Nursing intervention protocol by using aromatherapy should be developed and applied in clinical and community settings. Further studies on the effects of aromatherapy on stress should be done by using meta-analysis.

  • PDF

The study of Breast Specific Gamma Imaging Protocol using Self-development Phantom (자체 제작된 팬텀을 적용한 Breast Specific Gamma Imaging 검사 프로토콜에 대한 고찰)

  • Lee, Hae-Jung;Lee, Juyoung;Lim, Kuen-Kyo;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.39-47
    • /
    • 2014
  • Purpose As breast cancer patients continue to increase every year, cases of BSGI are on the rise with a heavier reliance on it. However, BSGI protocol in hospitals was not studied enough despite it was covered by hospital's condition and recommendation of manufacturers. The objective of the study was an examination of methods to be applicable to BSGI protocols, putting the self-development phantom to use in quality assessment of the images. Materials and Methods Dilon 6800 (Dilon Technologies Inc, Newport News, USA) was used in the study and five different sizes of sphere were distinctively produced in the phantom. The study used $^{99m}TcO_4$. The cases were classified in to three categories that background radioactivity to region of interest as ratio of 2: 4: 8, They were acquired images for 5, 7, 10mins. The acquired image was set region of interest according to the size of sphere, and We analyzed quantitative and qualitative analysis. The acquired data statistically analyzed with SPSS ver.18.0. Results As the result of quantitative and qualitative analysis, count rate of each sphere in accordance with difference of injection dose showed that higher count rate as injection dose and sphere size increased (P<0.005). Count rate of each sphere in accordance with difference of acquisition time showed that higher count rate as acquisition time and sphere size increased (P<0.005). Contrast noise ratio of each sphere in accordance with difference of injection dose showed that higher contrast noise ratio as injection dose increased. Particularly, Contrast noise ratio of eight times ratio images was the highest among. Contrast noise ratio of each sphere in accordance with difference of acquisition time showed that higher contrast noise ratio as acquisition time increased. And, Contrast noise ratio of seven minute image was the highest among (P<0.005). Conclusion There was significant change of Contrast noise ratio through quantitative and qualitative analysis. Moreover, We found usefulness of phantom. If Institutions identified image through the phantom study and they made BSGI protocol, We expected to help the improvement of diagnostic value of the images.

  • PDF

Evaluation of difference in respiratory phase between amplitude- and phase-based four-dimensional computed tomography (위상 기반 사차원전산화단층촬영과 진폭 기반 사차원전산화단층촬영 영상에서의 위상차 평가)

  • Lee, So Hyang;Park, Soo Yeon;Kim, Jong Sik;Choi, Byung Ki;Park, Hee Chul;Jung, Sang Hoon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.1
    • /
    • pp.73-78
    • /
    • 2015
  • Purpose : Under the assumption of change to the amplitude based sorting, the study will use four dimensional computed tomography imaging (4DCT) arrayed using the phase based sorting to analyze the respiratory phase difference. Materials and Methods : The study analyzed the 4DCT (4-dimensional computed tomography) images of 10 liver cancer patients that were treated with respiratory gated radiotherapy from 2015 February to March. Using RPM respiratory gating (RPM 1.7.5, Varian, USA) equipment, imaging according to respiratory cycle of phase based sorting was acquired and using a treatment planning system (Pinnacle 9.2, Philips, USA) the acquired imaging according to respiratory cycle was used to measure the abdominal movement value by respiratory cycle. The measuring point was the point where the center point of the Marker Block and the body surface met in the 50% phase image and here the coordinate values Lateral, Vertical, Longitudinal (X, Y, Z) were set as reference points, and on the X, Z plane identical to the reference point, using the identical method the Y axis coordinate value of each 0%, 30%, 40%, 50%, 60%, 80% phase images were acquired to quantitatively measure the variation of distance to the Y axis. The abdominal movement value according to respiration was applied to the theoretical model that the value decreases linearly from maximum inhalation to maximum exhalation to divide the variation of my value to predict as amplitude value by respiratory cycle and conversely the variation in amplitude was recalculated with the phase variation deviation value to analyze. Results : The deviation value between expected value and actual location was the largest in the 30% phase with 0.24 cm, and standard deviation was also the largest in 30% phase with 0.13 cm. The effective value of the deviation value derived from the average of the deviation squared value of each patient appeared as minimum 0.7 cm, maximum 0.18 cm, average 0.12 cm, and standard deviation 0.4 cm. Also by dividing the actual movement distance value with the peak expiration value then converting it into %Phase, the deviation value with actual phase 16.5% in 30% phase, 10.0% and 40% phase, 10.0% and 60% phase, 15.4% and 80% phase, and overall average about 13%, and arraying based on amplitude, phase shift occurred and further it was from peak expiration the chance of deviation occurrence was increasingly measured. Conclusion : Based on the results of the study there were differences between value acquired based on theoretical model and actual value. Therefore in respiratory gated radiotherapy using external surrogates, there needs to be establishment of respiration gated radiation system that avoids the combination of two Sorting methods considering that there will be occurrence of treatment and corresponding clinical differences due to the phase difference that occur due to the Amplitude based Phase Sorting.

  • PDF

Evaluating the Impact of Attenuation Correction Difference According to the Lipiodol in PET/CT after TACE (간동맥 화학 색전술에 사용하는 Lipiodol에 의한 감쇠 오차가 PET/CT검사에서 영상에 미치는 영향 평가)

  • Cha, Eun Sun;Hong, Gun chul;Park, Hoon;Choi, Choon Ki;Seok, Jae Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.67-70
    • /
    • 2013
  • Purpose: Surge in patients with hepatocellular carcinoma, hepatic artery chemical embolization is one of the effective interventional procedures. The PET/CT examination plays an important role in determining the presence of residual cancer cells and metastasis, and prognosis after embolization. The other hand, the hepatic artery chemical embolization of embolic material used lipiodol produced artifacts in the PET/CT examination, and these artifacts results in quantitative evaluation influence. This study, the radioactivity density and the percentage error was evaluated by the extent of the impact of lipiodol in the image of PET/CT. Materials and Methods: 1994 NEMA Phantom was acquired for 2 minutes and 30 seconds per bed after the Teflon, water and lipiodol filled, and these three inserts into the enough to mix the rest behind radioactive injection with $20{\pm}10MBq$. Phantom reconfigure with the iterative reconstruction method the number of iterations for two times by law, a subset of 20 errors. We set up region of interest at each area of the Teflon, water, lipiodol, insert artifact occurs between regions, and background and it was calculated and compared by the radioactivity density(kBq/ml) and the% Difference. Results: Radioactivity density of the each region of interest area with the teflon, water, lipiodol, insert artifact occurs between regions, background activity was $0.09{\pm}0.04$, $0.40{\pm}0.17$, $1.55{\pm}0.75$, $2.5{\pm}1.09$, $2.65{\pm}1.16 kBq/ml$ (P <0.05) and it was statistically significant results. Percentage error of lipiodol in each area was 118%, compared to the water compared with the background activity 52%, compared with a teflon was 180% of the difference. Conclusion: We found that the error due to under the influence of the attenuation correction when PET/CT scans after lipiodol injection performed, and the radioactivity density is higher than compared to other implants, lower than background. Applying the nonattenuation correction images, and after hepatic artery chemical embolization who underwent PET/CT imaging so that the test should be take the consideration to the extent of the impact of lipiodol be.

  • PDF

Analysis on the Dosimetric Characteristics of Tangential Breast Intensity Modulated Radiotherapy (유방암의 접선 세기조절 방사선치료 선량 특성 분석)

  • Yoon, Mee Sun;Kim, Yong-Hyeob;Jeong, Jae-Uk;Nam, Taek-Keun;Ahn, Sung-Ja;Chung, Wong-Ki;Song, Ju-Young
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.219-228
    • /
    • 2012
  • The tangential breast intensity modulated radiotherapy (T-B IMRT) technique, which uses the same tangential fields as conventional 3-dimensional conformal radiotherapy (3D-CRT) plans with physical wedges, was analyzed in terms of the calculated dose distribution feature and dosimetric accuracy of beam delivery during treatment. T-B IMRT plans were prepared for 15 patients with breast cancer who were already treated with conventional 3D-CRT. The homogeneity of the dose distribution to the target volume was improved, and the dose delivered to the normal tissues and critical organs was reduced compared with that in 3D-CRT plans. Quality assurance (QA) plans with the appropriate phantoms were used to analyze the dosimetric accuracy of T-B IMRT. An ionization chamber placed at the hole of an acrylic cylindrical phantom was used for the point dose measurement, and the mean error from the calculated dose was $0.7{\pm}1.4%$. The accuracy of the dose distribution was verified with a 2D diode detector array, and the mean pass rate calculated from the gamma evaluation was $97.3{\pm}2.9%$. We confirmed the advantages of a T-B IMRT in the dose distribution and verified the dosimetric accuracy from the QA performance which should still be regarded as an important process even in the simple technique as T-B IMRT in order to maintain a good quality.