Kim, Young Il;Park, Hee Chul;Lim, Do Hoon;Park, Hyo Jung;Kang, Sang Won;Park, Su Yeon;Kim, Jin Sung;Han, Youngyih;Paik, Seung Woon
Radiation Oncology Journal
/
제30권4호
/
pp.189-196
/
2012
Purpose: To investigate the safety of high dose hypofractionated radiotherapy (RT) in patients with small hepatocellular carcinoma (HCC) in terms of liver volumetric changes and clinical liver function. Materials and Methods: We retrospectively reviewed 16 patients with small HCC who were treated with high dose hypofractionated RT between 2006 and 2009. The serial changes of the liver volumetric parameter were analyzed from pre-RT and follow-up (FU) computed tomography (CT) scans. We estimated linear time trends of whole liver volume using a linear mixed model. The serial changes of the Child-Pugh (CP) scores were also analyzed in relation to the volumetric changes. Results: Mean pre-RT volume of entire liver was 1,192.2 mL (range, 502.6 to 1,310.2 mL) and mean clinical target volume was 14.7 mL (range, 1.56 to 70.07 mL). Fourteen (87.5%) patients had 4 FU CT sets and 2 (12.5%) patients had 3 FU CT sets. Mean interval between FU CT acquisition was 2.5 months. After considering age, gender and the irradiated liver volume as a fixed effects, the mixed model analysis confirmed that the change in liver volume is not significant throughout the time course of FU periods. Majority of patients had a CP score change less than 2 except in 1 patient who had CP score change more than 3. Conclusion: The high dose hypofractionated RT for small HCC is relatively safe and feasible in terms of liver volumetric changes and clinical liver function.
The using of compensator is required to adjust the irregular dose distribution due to irregular thickness of the body in Total Body Irradiation. Aluminuim, copper or lead is generally used as compensator. In our study, we would like to introduce a result of the attenuation and compensation effect of radiation use compensator made by duralumin and its clinical use. The thickness of compensator was calculated by the attenustion of radiation, which was measured by polystyrene phantom and ionization chamber(farmer). The compensation effect of radiation was measured by diode detector. All of conditions were set as in real treatment, and the distanc from source to detector was 446 cm. We also made fixation of device to easily attach the compensator to LINAC. Beam spoiler was menufactured and placed on the patient to irradiate sufficient dose to the skin. diode detector were placed on head, neck, chest, umbilicus. pelvis and knee with each their entranced exit points, and datas of dose distribution were evaluated and compared in each points for eleven patients(Feb. 96-Feb. 97). The attenuation rate of irradiation by duralumin compensator was measured as $1.4\%$ in 2mm thickness. The mean attenuation rate was $1.3\%$ per 2mm as increasing the thickness gradually to 50 mm. By using duralunim compensator, dose distribution in each points of body was measured with ${\pm}2.8\%$ by diode detectior. We could easily calculate the thickness of compensator by measuring the attenuation rate of radiation, remarkably reduce the irragularity of dose distribution duo to the thickness of body and magnify the effect of radiation therapy.
Low-dose radiotherapy has been known to have anti-inflammatory activity and been used for treatment of pneumonia together with anti-serum and sulfanilamide. However, it rapidly discontinued after the development of various antibiotics showing outstanding effect. Recently, it was re-considered to treat COVID-19 which has very limited treatment such as remdesivir and dexamethasone. So, several studies of COVID-19 therapy using low-dose radiation were reported very recently. They showed that low-dose radiation of 0.5~1.5 Gy were useful for decreasing the oxygen consumption and hospitalization period of COVID-19 patients without adverse reaction. Radiopharmaceuticals such as [99mTc]Tc-macroaggregated albumin (MAA) also might be used for low-dose radiotherapy. Administration of vitamin D having anti-inflammatory effect would also be helpful for therapy with synergistic effect.
Aims: To prospectively assess the efficacy and safety of moderately hypofractionated conformal radiotherapy in patients with thoracic esophageal cancer. Methods and Materials: From Sept. 2002 to Oct, 2005, 150 eligible patients with T2-4N0-1M0 stage thoracic esophageal squamous cell cancers were enrolled to receive either conventional fractionated radiation (CFR) or moderately hypofractionated radiation (MHR) with a three-dimensional conformal radiation technique. Of the total, 74 received moderately hypofractionated radiation with total dose of 54-60Gy/18-20fractions for 3.5-4 weeks in the MHR arm, and 76 received conventional radiation with total dose of 60Gy/30 fractions for 6 weeks in the CFR arm. Concurrent chemotherapy comprised of paclitaxel and cisplatin. Safety was evaluated, and local control and overall survival rates were calculated. Results: Statistically significant differences between the CFR versus MHR arms were observed in local/regional failure rate (47.3% v 27.0%, P=0.034) and the percentage of patients with persistent local disease (26.3% v 10.8%, P=0.012). But 3 and 5-year overall survival rates (43.2%, 38.8% v 38.2%, 28.0%, respectively) were not different between the two arms (P=0.268). There were no significant differences in the incidences of grade 3 or higher acute toxicities (66.3% v 50.0%) and late complications rates (27.0% v 22.4%) between the MHR and CFR arms. Conclusions: Moderately hypofractionated, three-dimensional radiation treatment could improve the local control rate of esophageal cancer and potentially increase patients' survival.
From Feb.1985 to Feb.1988,76 patients with squamous cell carcinoma of the lung treated at the Department of Therapeutic Radiology in Kyungpook National University Hospital were available for the analysis of this study. All patients received radiation of 4000cGy-6600cGy with curative aim. The overall rate of complete response was 25.0% and partial response was 452.6% The complete and partial regression of tumor was 14.3% in patients treated with dose below 5000cGy and 84.1% in the group treated with dose above 5000cGy (p<0.01). The complete response was seen only in the group of patients received radiation at least 6000cGy. The patterns of failure were as follows. The rate of initial intrathoracic recurrence was 52.6% in patients with complete response. The overall rate of failure was 68.8%. Distant metastasis was found in 47.4% of patients. Bone, contralateral lung, and brain were common metastatic sites in decreasing order All of the distant metastases and 80% of local recurrences were found within the first year after treatment.
Lee, Kyung Hwa;Yu, Jeong Il;Park, Hee Chul;Park, Su Yeon;Shin, Jung Suk;Shin, Eun Hyuk;Cho, Sungkoo;Jung, Sang Hoon;Han, Young Yih;Lim, Do Hoon
Radiation Oncology Journal
/
제36권2호
/
pp.129-138
/
2018
Purpose: This study was conducted to compare clinical outcomes and treatment-related toxicities after stereotactic body radiation therapy (SBRT) with two different dose regimens for small hepatocellular carcinomas (HCC) ${\leq}3cm$ in size. Materials and Methods: We retrospectively reviewed 44 patients with liver-confined HCC treated between 2009 and 2014 with SBRT. Total doses of 45 Gy (n = 10) or 60 Gy (n = 34) in 3 fractions were prescribed to the 95% isodose line covering 95% of the planning target volume. Rates of local control (LC), intrahepatic failure-free survival (IHFFS), distant metastasis-free survival (DMFS), and overall survival (OS) were calculated using the Kaplan-Meier method. Results: Median follow-up was 29 months (range, 8 to 64 months). Rates at 1 and 3 years were 97.7% and 95.0% for LC, 97.7% and 80.7% for OS, 76% and 40.5% for IHFFS, and 87.3% and 79.5% for DMFS. Five patients (11.4%) experienced degradation of albumin-bilirubin grade, 2 (4.5%) degradation of Child-Pugh score, and 4 (9.1%) grade 3 or greater laboratory abnormalities within 3 months after SBRT. No significant difference was seen in any oncological outcomes or treatment-related toxicities between the two dose regimens. Conclusions: SBRT was highly effective for local control without severe toxicities in patients with HCC smaller than 3 cm. The regimen of a total dose of 45 Gy in 3 fractions was comparable to 60 Gy in efficacy and safety of SBRT for small HCC.
구강 및 두경부 암의 방사선치료 시 치료 범위에 피부를 포함하는 경우가 많으며 이때 볼루스의 사용이 빈번해진다. 특히 턱 부분의 요철로 인하여 환자의 적용 시 선량 불확실성을 제공한다. 본 연구에서는 3D Printing을 이용하여 Gel 볼루스와 Poly lactic acid(PLA), Silicon을 적용한 환자 맞춤형 볼루스를 제작하여 물성 특성을 확인하고, 제작된 볼루스와 치료계획의 불일치성을 확인하며, 실제 방사선 선량 전달시 발생하는 선량불확실성을 측정하였다. 그 결과 일반적인 요철 부위에는 PLA 재질의 볼루스가 안정적이며, 요철이 심하거나 환자의 체형이 자주 바뀔 수 있는 환자의 경우 Silicon 재질의 볼루스가 유용할 것으로 사료된다.
Purpose: This study evaluated the treatment effectiveness and proper radiation dose of helical tomotherapy (HT) in spine oligometastases from gastrointestinal cancers. Materials and Methods: From 2006 to 2010, 20 gastrointestinal cancer patients were treated with HT for spine oligometastases (31 spine lesions). The gross tumor volume (GTV) was the tumor evident from magnetic resonance imaging images fused with simulation computed tomography images. Clinical target volume (CTV) encompassed involved vertebral bodies or dorsal elements. We assumed that the planning target volume was equal to the CTV. We assessed local control rate after HT for 31 spine metastases. Pain response was scored by using a numeric pain intensity scale (NPIS, from 0 to 10). Results: Spine metastatic lesions were treated with median dose of 40 Gy (range, 24 to 51 Gy) and median 5 Gy per fraction (range, 2.5 to 8 Gy) to GTV with median 8 fractions (range, 3 to 20 fraction). Median biologically equivalent dose (BED, ${\alpha}/{\beta}$ = 10 Gy) was 52 $Gy_{10}$ (range, 37.5 to 76.8 $Gy_{10}$) to GTV. Six month local control rate for spine metastasis was 90.3%. Overall infield failure rate was 15% and outfield failure rate was 75%. Most patients showed pain relief after HT (93.8%). Median local recurrence free survival was 3 months. BED over 57 $Gy_{10}$ and oligometastases were identified as prognostic factors associated with improved local progression free survival (p = 0.012, P = 0.041). Conclusion: HT was capable of delivering higher BED to metastatic lesions in close proximity of the spinal cord. Spine metastases from gastrointestinal tumors were sensitive to high dose radiation, and BED (${\alpha}/{\beta}$ = 10 Gy) higher than 57 $Gy_{10}$ could improve local control.
목적 : 방사선 방광염 및 방사선 직장염은 자궁경부암의 방사선 치료시에 흔히 문제가 되는 만성 부작용이다. 저자들은 자궁경부암의 자궁 강내 방사선치료시에 직장과 방광의 방사선량을 줄일 수 있는 환자의 치료자세를 규명하고자 하였다. 대상 및 방법 : 13예의 환자에서 환자의 방광과 직장에 도뇨관을 삽입한 후에 조영제로 팽대부를 팽대한다. tandem과 두 개의 ovoid를 삽입한 후에 쇄석위와 앙와위에서 semi- orthogonal로 AP, Lat 사진을 촬영한다. 사진에서 ICRU Report 38 권장을 약간 변경한 방법에 따라 방광과 직장의 대표점을 구하고 A point 의 방사선량이 400cGy일 때의 방광과 직장의 방사선량을 각 치료자세에서 구한다. 또한 cervical os 로부터 방광과 직장까지의 거리도 각각 계산한다. 결과 : 직장 방사선량의 평균은 쇄석위에서 240.7cGy 앙와위에서 278.3cGy였고 방광 방사선량의 평균은 쇄석위에서 303.5cGy 앙와위에서 255.8cGy 였다. 쇄석위의 직장선량이 앙와위의 직장선량보다 한계적으로 유의하게 낮았고, 쇄석위의 방광선량은 앙와위의 방광선량보다 유의하게 높았다. 자궁경부의 external os 로부터 직장까지의 평균거리는 쇄석위에서 35.2mm 앙와위에서 32.3mm 였고, 자궁경부의 external os 로부터 방광까지의 평균거리는 쇄석위에서 30.4 mm 앙와위에서 34.0mm 였다. 직장까지의 거리는 쇄석위의 경우가 앙와위보다 유의하게 멀었고, 방광까지의 거리는 쇄석위의 경우가 앙와위보다 유의하게 가까웠다. 결론 : 자궁경부암의 강내치료 시 쇄석위로 치료할 경우 직장선량을 줄일 수 있었고 앙와위로 치료할 경우 방광선량을 줄일 수 있었다.
Hong, Ji Hee;Park, Eun Kyul;Park, Ki Bum;Park, Ji Hoon;Jung, Sung Won
The Korean Journal of Pain
/
제30권3호
/
pp.220-228
/
2017
Background: The transforaminal (TF) epidural steroid injection (ESI) is suggested as more effective than the interlaminar (IL) route due to higher delivery of medication at the anterior epidural space. However, serious complications such as spinal cord injury and permanent neural injury have been reported. The purpose of this study is to evaluate and compare the clinical effectiveness, technical ease, and safety of the TF and parasagittal IL (PIL) ESI. Methods: A total of 72 patients were randomized to either the PIL group (n = 41) or the TF group (n = 31) under fluoroscopic guidance. Patients were evaluated for effective pain relief by the numerical rating scale (NRS) and Oswestry Disability Index (ODI) (%) before and 2 weeks after the ESI. The presence of concordant paresthesia, anterior epidural spread, total procedure time, and exposed radiation dose were also evaluated. Results: Both the PIL and TF approach produced similar clinically significant improvements in pain and level of disability. Among the 72 patients, 27 PIL (66%) and 20 TF (64%) patients showed concordant paresthesia while 14 (34%) and 11 (36%) patients in the same respective order showed disconcordant or no paresthesia. Radiation dose and total procedure time required were compared; the PIL group showed a significantly lower radiation dose ($30.2{\pm}12$ vs. $80.8{\pm}26.8$ [$Cgy/cm^2$]) and shorter procedure time ($96.2{\pm}31$ vs. $141.6{\pm}30$ seconds). Conclusions: ESI under fluoroscopic guidance with PIL or TF approach were effective in reducing the NRS and ODI. PIL ESI was a technically easier and simple method compared to TF ESI.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.