• Title/Summary/Keyword: Patients' radiation dose

Search Result 1,495, Processing Time 0.028 seconds

VCUG Studies on the Clinical Usefulness of Aids (VCUG 보조기구의 임상적 유용성에 관한 고찰)

  • Choe, Dea yeon;Kim, Dong hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.7
    • /
    • pp.529-533
    • /
    • 2015
  • VCUG(Voiding Cystourethrography) study is being performed to check urinary reflex symptom from bladder to ureter or kidney in the method of filling the bladder with radiation opaque contrast agent. However, VCUG study have been performed impersonally, patients have to be naked and open their legs and then void. This method is so impersonal that it is immediately needed to improve the way of testing and crete new aid. Therefore, this study through producing underwear for VCUG, analysis and compares the test time of VCUG, patient radiation dose and patient satisfaction. The target of this study was 79 Male and Female patients who visited genitourinary clinic of PNUYH for their VCUG tests AXIUM Iconos R200(Siemens Medical System : Germany) and self-produced plastic underwears made by vinyl and plasic molding machine were used. The 79 patient were divided into two groups : experiment of patient and comparison group of we patient (using aid) in order to compare, testing time, DAP (dose area product) and patient satisfaction. There was time reduction, from 35.3min of comparison group to 27.8min experimentation group by 7.5min decrease. And comparison group of $4566.6{\mu}Gym^2$(DAP) decreased experimental group (using aid) of $3411.9{\mu}Gym^2$ by $1154.7{\mu}Gym^2$. In the case of patients satisfaction study, anxiety had a drop by 3.45 of comparison group to 2.51 experimentation group by 0.94 decrease. in experimental group. And shame had a drop by 4.02 of comparison group to 3.08 experimentation group by 0.94 increase. in experimental group. Difference of the smooth voiding had a drop by 1.90 of comparison group to 2.84 experimentation group by 0.94 increase. in experimental group. In addition satisfaction had a rise by 1.19 in experimental group. There were also other opinions of uncomfortableness on it and troublesome to wear. VCUG is one of the sensitive care required test. Therefore staff and the aid can give patients such comfortable and the aid can consentive on voiding. As a result test time and DAP can be reduced. It is needed to make testing at more comfortable for patients.

Postoperative Radiotherapy for Non-Small Cell Lung Cancer (비소세포성 폐암의 수술 후 방사선치료)

  • Chun, Ha-Chung;Lee, Myung-Za
    • Radiation Oncology Journal
    • /
    • v.19 no.2
    • /
    • pp.113-117
    • /
    • 2001
  • Purpose : To evaluate effect of postoperative radiotherapy on survival and local control for patients with non-small cell lung cancer (NSCLC). Materials and Methods : Ninety two NSCLC patients with N1or N2 involvement who were treated with postoperative radiotherapy following surgery with curative intent from May 1987 to October 1999 were retrospectively analyzed. Age of the patients was ranged from 32 to 78 years. According to TNM Stage, 35 patients had Stage II and 57 had Stage III disease. There were 49 patients with N1 involvement and 43 patients with N2 involvement. Fifty six patients were noted to have $T1\~2$ tumors and 36 patients to have $T3\~4$ tumors. Delivered total dose was ranged from 40 to 60 Gy. Majority of patients received 50 Gy or 50.4 Gy. Follow-up period was ranged from 9 month to 7 years with median follow-up of 26 months. Results : Overall survival rates at 3 and 5 years for entire group of patients were $46\%\;and\;38\%$, respectively. Corresponding disease free survival rates were $44\%\;and\;36\%$. There was significant difference in survival between patients with Stage II and Stage III disease ($50\%\;vs\;28\%$ at 5-year). Five year survival rates for N1 and N2 patients were $52\%\;and\;20\%$, respectively (p<0.05). These were $40\%\;and\;34\%$ for patients with $T1\~2$ tumors and $T3\~4$ tumors. There were documented local relapses in $13\%$ of the patients. For patients with N1 and N2 Stage, local relapse rates were $8\%\;and\;18\%$, respectively. Conclusion : Our study confirms that postoperative radiotherapy for patients with non-small cell lung cancer improves local control. However, influence of postoperative radiotherapy on long-term survival is less clear. More effective systemic treatment to prevent distant metastasis should be investigated in future study to improve long-term survival.

  • PDF

Reliability Verification of FLUKA Transport Code for Double Layered X-ray Protective Sheet Design (이중 구조의 X선 차폐시트 설계를 위한 FLUKA 수송코드의 신뢰성 검증)

  • Kang, Sang Sik;Heo, Seung Wook;Choi, Il Hong;Jun, Jae Hoon;Yang, Sung Woo;Kim, Kyo Tae;Heo, Ye Ji;Park, Ji Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.547-553
    • /
    • 2017
  • In the current medical field, lead is widely used as a radiation shield. However, the lead weight is very heavy, so wearing protective clothing such as apron is difficult to wear for long periods of time and there is a problem with the danger of lethal toxicity in humans. Recently, many studies have been conducted to develop substitute materials of lead to resolve these problems. As a substitute materials for lead, barium(Ba) and iodine(I) have excellent shielding ability. But, It has characteristics emitting characteristic X-rays from the energy area near 30 keV. For patients or radiation workers, shielding materials is often made into contact with the human body. Therefore, the characteristic X-rays generated by the shielding material are directly exposured in the human body, which increases the risk of increasing radiation absorbed dose. In this study, we have developed the FLUKA transport code, one of the most suitable elements of radiation transport codes, to remove the characteristic X-rays generated by barium or iodine. We have verified the reliability of the shielding fraction of the structure of the structure shielding by comparing with the MCPDX simulations conducted as a prior study. Using the MCNPX and FLUKA, the double layer shielding structures with the various thickness combination consisting of barium sulphate ($BaSO_4$) and bismuth oxide($Bi_2O_3$) are designed. The accuracy of the type shown in IEC 61331-1 was geometrically identical to the simulation. In addition, the transmission spectrum and absorbed dose of the shielding material for the successive x-rays of 120 kVp spectra were compared with lead. In results, $0.3mm-BaSO_4/0.3mm-Bi_2O_3$ and $0.1mm-BaSO_4/0.5mm-Bi_2O_3$ structures have been absorbed in both 33 keV and 37 keV characteristic X-rays. In addition, for high-energy X-rays greater than 90 keV, the shielding efficiency was shown close to lead. Also, the transport code of the FLUKA's photon transport code was showed cut-off on low-energy X-rays(below 33keV) and is limited to computerized X-rays of the low-energy X-rays. But, In high-energy areas above 40 keV, the relative error with MCNPX was found to be highly reliable within 6 %.

Ultrastructural Effects of Irradiation on Squamous Cell Carcinoma of the Uterine Cervix (자궁경부의 편평상피암의 방사선치료에 수반되는 초미형태학적 변화)

  • Kim Jin Hee;Kim Ok Bae;Choi Tae Jin;Lee Sang Sook;Park Kwan Kyu;Kwon Kun Young;Suh Young Wook;Lee Tae Sung;Lee Tak;Cha Soon Do
    • Radiation Oncology Journal
    • /
    • v.9 no.2
    • /
    • pp.303-310
    • /
    • 1991
  • Nineteen patients with previously untreated invasive squamous cell carcinoma of the uterine cervix were treated by irradiation alone at the Keimyung University Hospital from January, 1990 to July, 1991. The serial samplings of the tissue taken before and during radiation of the uterine cervix were studied by light and electron microscopic examination. Radiation-induced cellular changes, particularly nuclear degeneration was pronounced. The tumor invasion pattern remained unchanged but the number of mitosis and tumor cells decreased, The number of infiltrating inflammatory cells, multinucleated giant cells and karyolytic cells were increased with radiation. Fibrosis was also increased. Electron microscopically, the amount of tonofilament in the tissue samplings was increased in the postirradiated state, but the desmosomes were decreased in numbers. Fibroblasts began to appear after an irradiation dose of 2700 cGy. After an irradiation dose of 3000 cGy or more, tumor cells were nearly completely degenerated and displaced with mature fibrotic tissue. There was an increase of activated fibroblasts and collagen fibers but a decrease of inflammatory cells in the interstitial tissue. Swelling of the mitochondria and endoplasmic reticulum, loss of intercellular bridges and an increased number of secondary lysosomes were also found with radiation.

  • PDF

Image and Exposure Dose in Accordance with Radiation Quality on Plain Chest Radiography (흉부촬영(胸部撮影)에서 증감지(增感紙)-필름계의 선질변화(線質變化)에 따른 감도(感度)와 화질에 관(關)한 연구(硏究))

  • Kim, Jung-Min;Kim, Dong-Huan;Hayashi, Taro;Ishida, Yuji;Maeda, Mika;Sakura, Tatsuya
    • Journal of radiological science and technology
    • /
    • v.15 no.1
    • /
    • pp.65-78
    • /
    • 1992
  • Routine chest radiography is generally imaged by high voltage technique but some radiological technologists use low voltage for imaging. High voltage is usually said between $120\;kV{\sim}140\;kV$. Some RTs like using heavy filtration but others seldom like using it. However which is better for use calcium tungustate film screen system or ortho system and high contrast film or wide latitude c-type film for the exculusive use of chest radiography. We could not make a decision which is ideal method for use. In my opinion any method is not always exellent for chest radiography. In my experiments that I had at Kaken hospital in Japan last year I expect to keep the balance between image quality and diagnostic range and to reduce radiation dose for patients. My experiments are as follows. 1. We have looked into system characteristics(speed and contrast) in accordance with kVp($80{\sim}140$) and added filter($no{\sim}1/16\;VL$) in three screen film systems(BX3+CRONEX4, SRO750+MGH, SRO750+MGL). 2. We have looked into skin dose and film dose with same D=1.8 lung field density in accordance with kVp($80{\sim}140$) and added filter($no{\sim}1/16\;VL$) in three screen film systems. 3. We have compared with the evaluation between correlation of physical image quality(MTF) and optical diagnostic capability. Result are follows. 1. Speed of BX3+CRONEX4 became higher in accodance with kVp and thickness of filter but speed of ortho system was not as like regular system. Thicker filter diminished the speed over 100 kV range in SRO750+MGL. In case of SRO750+MGH speed of 1/16VL filter was looked into lower than speed of 1/4VL filter. Sensitivity of ortho system depends on tube voltage and added filter. 2. Skin dose has been detected $225\;{\mu}Gy{\sim}66\;{\mu}Gy$ in BX3+CRONEX4 from 80 kV, no filter to 140 kV, 1/16VL filter. SRO750+MGH could reduce the patient dose $1/2{\sim}1/3$ level in comparison to that of BX3+CRONEX4. 3. The higher kV was the worse MTF became the thicker filter was the worse MTF became too. MTF of BX3+CRONEX4 was detected better than MTF of SRO750+MGH but SRO750+MGH's optical detectability of small lesion in lung field came out better than that of BX3+CRONEX4. Conclusion Recently routine chest radiography is generally imaged by high voltage but it seems to be there are some questions in using of film screen combination. In high voltage chest radiography the subject contrast will come down that means latitude become wider. In this case if we select the low contrast film screen system(C or L type) the film contrast will fall down extremly and detectability of small lesion will be deteriorated. Wide latitude C, L type film has a merit of high detectability on mediastinum. Furthermore high contrast film screen system has the advantage to keep the high contrast in low density region as like mediastinum and heart shadow. Therefore in low subject contrast high voltage chest radiography we would rather choose the high contrast film screen system(H type) I think. From a view point of patient dose detectability of mediastinum and lung field. The optimum technical facter was found out 120 kV, 1/16VL filter : BX3+CRONEX4, 140 kV, 1/4VL filter : SRO750+MGH, 100 kV, 1/4VL filter : SRO750+MGL.

  • PDF

Evaluate the implementation of Volumetric Modulated Arc Therapy QA in the radiation therapy treatment according to Various factors by using the Portal Dosimetry (용적변조회전 방사선치료에서 Portal Dosimetry를 이용한 선량평가의 재현성 분석)

  • Kim, Se Hyeon;Bae, Sun Myung;Seo, Dong Rin;Kang, Tae Young;Baek, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.167-174
    • /
    • 2015
  • Purpose : The pre-treatment QA using Portal dosimetry for Volumetric Arc Therapy To analyze whether maintaining the reproducibility depending on various factors. Materials and Methods : Test was used for TrueBeam STx$^{TM}$ (Ver.1.5, Varian, USA). Varian Eclipse Treatment planning system(TPS) was used for planning with total of seven patients include head and neck cancer, lung cancer, prostate cancer, and cervical cancer was established for a Portal dosimetry QA plan. In order to measure these plans, Portal Dosimetry application (Ver.10) (Varian) and Portal Vision aS1000 Imager was used. Each Points of QA was determined by dividing, before and after morning treatment, and the after afternoon treatment ended (after 4 hours). Calibration of EPID(Dark field correction, Flood field correction, Dose normalization) was implemented before Every QA measure points. MLC initialize was implemented after each QA points and QA was retried. Also before QA measurements, Beam Ouput at the each of QA points was measured using the Water Phantom and Ionization chamber(IBA dosimetry, Germany). Results : The mean values of the Gamma pass rate(GPR, 3%, 3mm) for every patients between morning, afternoon and evening was 97.3%, 96.1%, 95.4% and the patient's showing maximum difference was 95.7%, 94.2% 93.7%. The mean value of GPR before and after EPID calibration were 95.94%, 96.01%. The mean value of Beam Output were 100.45%, 100.46%, 100.59% at each QA points. The mean value of GPR before and after MLC initialization were 95.83%, 96.40%. Conclusion : Maintain the reproducibility of the Portal Dosimetry as a VMAT QA tool required management of the various factors that can affect the dosimetry.

  • PDF

MDM2, p53 and pRb Expression Prior to Definitive Chemoradiotherapy in Esophageal Carcinoma (식도암에서 MDM2, p53, pRb 발현과 동시적 항암화학방사선요법의 결과)

  • Yoon, Mee-Sun;Lee, Jae-Hyuk;Cho, Sang-Hee;Song, Ju-Young;Ahn, Sung-Ja;Chung, Ik-Joo;Chung, Woong-Ki;Nah, Byung-Sik;Nam, Taek-Keun
    • Radiation Oncology Journal
    • /
    • v.25 no.4
    • /
    • pp.193-200
    • /
    • 2007
  • Purpose: This study evaluated the pretreatment expression patterns of MDM2, p53, and pRb proteins to determine if the expression patterns could predict the outcome of concurrent chemoradiotherapy (CCRT) for esophageal squamous cell carcinoma and aid in the decisions for the selection of treatment modalities. Materials and Methods: Fifty-one patients that were treated with definitive chemoradiotherapy for stage $I{\sim}IVa$ esophageal squamous cell carcinoma were selected for this study. Radiotherapy was administered with daily $1.8{\sim}2\;Gy$ fractions up to a median dose of 54 Gy for primary tumors, and with four cycles of cisplatin/5-fluorouracil chemotherapy that was administered every 4 weeks, the first two cycles of which were administered concurrently with radiotherapy. Expression of MDM2, p53, and pRb was investigated by immunohistochemical analysis using pretreatment biopsy specimens. Results: MDM2, p53, and pRb were detected with high immunoreactivity in 19.6%, 27.5%, and 66.7% of the patients, respectively. However, there was no significant correlation between expression of these factors and clinical outcome. By the use of multivariate analysis with nine covariates-age, tumor location, tumor length, stage, pathological response, clinical response, MDM2 expression, p53 expression, and pRb expression, only pathological response and stage were significant factors for cause-specific survival. Conclusion: Expression of MDM2, p53, and pRb was not found to be clinically significant for predicting outcomes after CCRT in this study. Further studies with a larger patient population and longer follow-up periods are needed to re-evaluate the expression pattern and to identify new predictors for CCRT response.

Location Error of the Dens in a Two-Dimensional Set-up Verification During Head and Neck Radiotherapy (뇌.두경부 방사선치료 시 전자조사문영상장치를 이용한 세트업 오차 확인에서 제2경추 치상돌기 위치의 임상적 의의)

  • Kim, Dong-Hyun;Kim, Won-Taek;Ki, Yong-Gan;Nam, Ji-Ho;Lee, Mi-Ran;Jeon, Ho-Sang;Park, Dal;Kim, Dong-Won
    • Radiation Oncology Journal
    • /
    • v.29 no.2
    • /
    • pp.107-114
    • /
    • 2011
  • Purpose: To assess the degree and clinical impact of location error of the dens on the X-axis during radiotherapy to brain and head and neck tumors. Materials and Methods: Twenty-one patients with brain tumors or head and neck tumors who received three-dimensional conformal radiation therapy or intensity-modulated radiation therapy from January 2009 to June 2010 were included in this study. In comparison two-dimensional verification portal images with initial simulation images, location error of the nasal septum and the dens on the X-axis was measured. The effect of set-up errors of the dens was simulated in the planning system and analyzed with physical dose parameters. Results: A total of 402 portal images were reviewed. The mean location error at the nasal septum was 0.16 mm and at the dens was 0.33 mm (absolute value). Location errors of more than 3 mm were recorded in 43 cases (10.7%) at the nasal septum, compared to 133 cases (33.1%) at the dens. There was no case with a location error more than 5 mm at the nasal septum, compared to 11 cases (2.7%) at the dens. In a dosimetric simulation, a location error more than 5 mm at the dens could induce a reduction in the clinical target volume 1 coverage (V95: 100%${\rightarrow}$87.2%) and overdosing to a critical normal organ (Spinal cord V45: <0.1%${\rightarrow}$12.6%). Conclusion: In both brain and head and neck radiotherapy, a relatively larger set-up error was detected at the dens than the nasal septum when using an electronic portal imaging device. Consideration of the location error of the dens is necessary at the time of the precise radiation beam delivery in two-dimensional verification systems.

Therapeutic Results of Radiotherapy in Rectal Carcinoma - Comparison of Sandwich Technique Radiotherapy with Postoperative Radiotherapy (직장암의 방사선 치료 결과 - Sandwich Technique 방사선 치료와 수술후 방사선 치료의 비교)

  • Huh Cil Cha;Suh Hyun Suk;Lee Hyuk Sang;Kim Re Hwe;Kim Chul Soo;Kim Hong Yong;Kim Sung Rok
    • Radiation Oncology Journal
    • /
    • v.14 no.1
    • /
    • pp.25-31
    • /
    • 1996
  • Purpose : To evaluate the potential advantage for 'sandwich' technique radiotherapy compared to Postoperative radiotherapy in resectable rectal cancer. Materials and Methods : Between January 1989 and Mar 1994, 60 patients with resectable rectal cancer were treated at Inje University Seoul and Sanggye Paik Hospital. Fifty one patients were available for analysis: 20 patients were treated with sandwich technique radiotherapy and 31 patients were treated with Postoperative radiotherapy. In sandwich technique radiotherapy(RT), Patients were treated with preoperative RT 1500 cGy/5fx, followed by immediate curative resection. Patients staged as Astler-Coiler B2, C were considered for postoperative RT with 2500-4500 cGy. in postoperative RT total radiation dose of 4500-6120 cGy, 180 cGy daily at 4-Sweets was delivered. Patients were followed for median period of 25 months. Results : The overall 5-year survival rates for sandwich RT group and postoperative RT group were $60\%$ and $71\%$, respectively(p>0.05). The 5-rear disease free survival rates for each group were $63\%$. There was no difference in local failure rate between two groups($11\%$ versus $7\%$) Incidence of distant metastasis was $11\%$(2/20) in the sandwich technique RT group and $20\%$(6/31) in the postoperative RT group(p>0.05). The frequencies of acute and chronic complications were comparable in both groups. Conclusion : The sandwich technique radiotherapy group shows local recurrence and survival similar to those of Postoperative RT alone group but reduced distant metastasis compared to Postoperative RT group. But long term follow-up and large number of patients is needed to make an any firm conclusion regarding the value of this sandwich technique RT.

  • PDF

Evaluation of Effective Dose in Dental Radiography (치과 방사선 검사에서 유효선량 평가)

  • Han, Su-Chul;Lee, Bo-Ram;Shin, Gwi-Soon;Choi, Jong-Hak;Park, Hyok;Park, Chang-Seo;Chang, Kye-Yong;Kim, Bo-Ram;Kim, You-Hyun
    • Journal of radiological science and technology
    • /
    • v.34 no.1
    • /
    • pp.27-33
    • /
    • 2011
  • Along with the developments of science technology, up-to-date medical radiation equipments are introduced. Those equipments has brought many progresses in diagnosing patients not only in the quantitative aspects but in the qualitative ones. Especially, in the case of dental radiography, patients can be exposed more than CT, cone beam computed tomography (CBCT). In this study, we used human phantom and TLD-100H to measure the organ dose in each dental radiography and computed the effective dose according to ICRP (International Committee for Radioactivity Prevention) 60, 103. We measured the effective dose to be 5.1 and $29.5{\mu}Sv$ in the panoramic radiography and 11.2 and $14.4{\mu}Sv$ in the cephalometric radiography respectively. We also executed the CBCT and CT test on the maxillaries and the mandibles and found the amounts of effective dose were 53.7, 209.6, 129, and $391.5{\mu}Sv$ respectively in the CBCT and $93.3{\mu}$, 139.5, 282.7 and $489.7{\mu}Sv$ in the CT test. Consequently, it was shown that the effective dose in the CBCT test was lower than one in the CT test, but was higher in both panoramic and cephalometric radiography.